924 resultados para T-PARAMETERS


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Electric activity of the heart consists of repeated cardiomyocyte depolarizations and repolarizations. Abnormalities in repolarization predispose to ventricular arrhythmias. In body surface electrocardiogram, ventricular repolarization generates the T wave. Several electrocardiographic measures have been developed both for clinical and research purposes to detect repolarization abnormalities. The study aim was to investigate modifiers of ventricular repolarization with the focus on the relationship of the left ventricular mass, antihypertensive drugs, and common gene variants, to electrocardiographic repolarization parameters. The prognostic value of repolarization parameters was also assessed. The study subjects originated from a population of more than 200 middle-aged hypertensive men attending the GENRES hypertension study, and from an epidemiological survey, the Health 2000 Study, including more than 6000 participants. Ventricular repolarization was analysed from digital standard 12-lead resting electrocardiograms with two QT-interval based repolarization parameters (QT interval, T-wave peak to T-wave end interval) and with a set of four T-wave morphology parameters. The results showed that in hypertensive men, a linear change in repolarization parameters is present even in the normal range of left ventricular mass, and that even mild left ventricular hypertrophy is associated with potentially adverse electrocardiographic repolarization changes. In addition, treatments with losartan, bisoprolol, amlodipine, and hydrochlorothiazide have divergent short-term effects on repolarization parameters in hypertensive men. Analyses of the general population sample showed that single nucleotide polymorphisms in KCNH2, KCNE1, and NOS1AP genes are associated with changes in QT-interval based repolarization parameters but not consistently with T-wave morphology parameters. T-wave morphology parameters, but not QT interval or T-wave peak to T-wave end interval, provided independent prognostic information on mortality. The prognostic value was specifically related to cardiovascular mortality. The results indicate that, in hypertension, altered ventricular repolarization is already present in mild left ventricular mass increase, and that commonly used antihypertensive drugs may relatively rapidly and treatment-specifically modify electrocardiographic repolarization parameters. Common variants in cardiac ion channel genes and NOS1AP gene may also modify repolarization-related arrhythmia vulnerability. In the general population, T-wave morphology parameters may be useful in the risk assessment of cardiovascular mortality.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Shell model calculation of defect energies in alkali halides have been carried out using the ion-dependent, crystal-independent potential parameters of Sangster and Atwood (1978). Results indicate that appreciable differences exist between barrier heights for migration of cations and anions. While barrier heights for cations are generally lower than for anions in alkali halides of NaCl structure, the opposite is true in alkali halides of CsCl structure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new theoretical equation for interaction parameter in multicomponent metallic solutions is developed using the pseudopotential formalism coupled with the free energy of the hard sphere system. The approximate expression for the pseudopotential term is given in terms of the heat of solution at infinite dilution, to allow easy evaluation of the interaction parameter in various multicomponent systems. This theory has been applied to 23 non-ferrous alloys based on Pb, Sn, Bi and indium. Comparison with the results of previous theoretical calculations using only the hard sphere model suggests that the inclusion of the pseudopotential term yields a quantitatively more correct prediction of interaction parameters in multicomponent metallic solutions. Numerical calculations were also made for 320 Fe-base solutions relevant to steelmaking and the agreement between calculation and experimental data appears reasonable, with 90% reliability in predicting the correct sign.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The electrochemical properties of the film-covered anode/solution interface in the magnesium/ manganese dioxide dry cell have been evaluated. The most plausible electrical equivalent circuit description of the Mg/solution interface with the passive film intact, has been identified. These results are based on the analysis of ac impedance and voltage transient measurements made on the dry cell under conditions which cause no damage to the protective passive film on the anode. The study demonstrates the complementary character of impedance and transient measurements when widely different frequency ranges are sampled in each type of investigation. The values and temperature dependence of the anode-film resistance, film capacitance, double-layer capacitance and charge-transfer resistance of the film-covered magnesium/solution interface have been determined. The magnitude of these values and its implications in understanding the important performance aspects of the magnesium/manganese dioxide dry cell are discussed. The study may be extended, in principle, to Li, Al and Ca batteries.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The electrochemical properties of the film-covered anode/solution interface in the magnesium/ manganese dioxide dry cell have been evaluated. The most plausible electrical equivalent circuit description of the Mg/solution interface with the passive film intact, has been identified. These results are based on the analysis of ac impedance and voltage transient measurements made on the dry cell under conditions which cause no damage to the protective passive film on the anode. The study demonstrates the complementary character of impedance and transient measurements when widely different frequency ranges are sampled in each type of investigation. The values and temperature dependence of the anode-film resistance, film capacitance, double-layer capacitance and charge-transfer resistance of the film-covered magnesium/solution interface have been determined. The magnitude of these values and its implications in understanding the important performance aspects of the magnesium/manganese dioxide dry cell are discussed. The study may be extended, in principle, to Li, Al and Ca batteries.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Results are reported of comparative measurements made in 14 HV (high-voltage) laboratories in ten different countries. The theory of the proposed methods of characterizing the dynamic behavior is given, and the parameters to be used are discussed. Comparative measurements made using 95 systems based on 53 dividers are analyzed. This analysis shows that many of the system now in use, even though they fulfil the basic response requirements of the standards, do not meet the accuracy requirements. Because no transfer measurements were made between laboratories, there is no way to detect similar errors in both the system under test and the reference system. Hence, the situation may be worse than reported. This has led to the recommendation that comparative measurements should be the main route for quantifying industrial impulse measuring systems

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The problem of non-destructive determination of the state-of-charge of zinc- and magnesium-manganese dioxide dry batteries is examined experimentally from the viewpoint of internal impedance and open-circuit voltage at equilibrium. It is shown that the impedance is mainly charge-transfer controlled at relatively high states-of-charge and progressively changes over to diffusion control as the state-of-charge decreases in the case of zinc-manganese dioxide dry batteries. On the other hand, the impedance is mainly diffusion controlled for undischarged batteries but becomes charge-transfer controlled as soon as there is some discharge in the case of magnesium-manganese dioxide batteries. It is concluded that the determination of state-of-charge is not possible for both types of batteries by the measurement of impedance parameters due to film-induced fluctuations of these parameters. The measurement of open-circuit voltage at equilibrium can be used as a state-of-charge indicator for Zn-MnO2 batteries but not for Mg-MnO2 batteries.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The determination of the state-of-charge of the lead-acid battery has been examined from the viewpoint of internal impedance. It is shown that the impedance is controlled by charge transfer and to a smaller extent by diffusion processes in the frequency range 15–100 Hz. The equivalent series/parallel capacitance as well as the a.c. phase-shift show a parabolic dependence upon the state-of-charge, with a maximum or minimum at 50% charge. These results are explained on the basis of a uniform transmission-line analog equivalent circuit for the battery electrodes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The problem of nondestructive determination of the state-of-charge of nickel-cadmium batteries has been examined experimentally as well as theoretically from the viewpoint of internal impedance. It is shown that the modulus of the impedance is mainly controlled by diffusion at all states of charge. Even so, a prediction of the state of charge is possible if the equivalent series/parallel capacitance or the alternating current phase shift is measured at a sufficiently low a.c. test frequency (5–30 Hz) which also avoids inductive effects. These results are explained on the basis of a uniform transmission-line analog equivalent circuit for the battery electrodes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The small signal ac response is measured across the source-drain terminals of organic field-effect transistors (OFET) under dc bias to obtain the equivalent circuit parameters of poly(2,5-bis(3-tetradecylthiophen-2-yl)thieno[3,2-b]thiophene) (PBTTT) and poly(3-hexyl thiophene) (P3HT) based devices. The numerically simulated response based on these parameters is in good agreement with the experimental data for PBTTT-FET except at low frequencies, while the P3HT-FET data show significant deviations. This indicates that the interface with the metal electrode is rather complex for the latter, involving additional circuit elements arising from contact impedance or charge injection processes. Such an investigation can help in identifying the operational bottlenecks and to improve the performance of OFETs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

At an EMBO Workshop on DNA Curvature and Bending, held at Churchill College, Cambridge, on 10-15 September 1988, two sessions were scheduled on definitions of parameters used to describe the geometry of nucleic acid chains and helices, and a common nomenclature for these parameters. The most widely used library of helix analysis programs, HELIB (Fratini et al., 1982; Dickerson, 1985) suffers from the fact that the translations and rotations as defined are not fully independent and depend to a certain extent upon the choice of overall helix axis. Several research groups have been engaged independently in developing alternative programs for the geometrical analysis of polynucleotide chains, but with different definitions of quantities calculated and with widely different nomenclature even when the same parameter was involved.