Resumo

The determination of the state-of-charge of the lead-acid battery has been examined from the viewpoint of internal impedance. It is shown that the impedance is controlled by charge transfer and to a smaller extent by diffusion processes in the frequency range 15–100 Hz. The equivalent series/parallel capacitance as well as the a.c. phase-shift show a parabolic dependence upon the state-of-charge, with a maximum or minimum at 50% charge. These results are explained on the basis of a uniform transmission-line analog equivalent circuit for the battery electrodes.

Formato

application/pdf

Identificador

http://eprints.iisc.ernet.in/34389/1/Lead_acid.pdf

Gopikanth, ML and Sathyanarayana, S (1979) Impedance parameters and the state-of-charge. II. Lead-acid battery. In: Journal of Applied Electrochemistry, 9 (3). pp. 369-379.

Publicador

Springer

Relação

http://www.springerlink.com/content/p1q5172516704wk1/

http://eprints.iisc.ernet.in/34389/

Palavras-Chave #Inorganic & Physical Chemistry
Tipo

Journal Article

PeerReviewed