Impedance parameters and the state-of charge. I. Nickel-cadmium battery


Autoria(s): Sathyanarayana, S; Venugopalan, S; Gopikanth, ML
Data(s)

1979

Resumo

The problem of nondestructive determination of the state-of-charge of nickel-cadmium batteries has been examined experimentally as well as theoretically from the viewpoint of internal impedance. It is shown that the modulus of the impedance is mainly controlled by diffusion at all states of charge. Even so, a prediction of the state of charge is possible if the equivalent series/parallel capacitance or the alternating current phase shift is measured at a sufficiently low a.c. test frequency (5–30 Hz) which also avoids inductive effects. These results are explained on the basis of a uniform transmission-line analog equivalent circuit for the battery electrodes.

Formato

application/pdf

Identificador

http://eprints.iisc.ernet.in/34525/1/Impedence.pdf

Sathyanarayana, S and Venugopalan, S and Gopikanth, ML (1979) Impedance parameters and the state-of charge. I. Nickel-cadmium battery. In: Journal of Applied Electrochemistry, 9 (1). pp. 125-139.

Publicador

Springer

Relação

http://www.springerlink.com/content/g132263685724k47/

http://eprints.iisc.ernet.in/34525/

Palavras-Chave #Inorganic & Physical Chemistry
Tipo

Journal Article

PeerReviewed