991 resultados para Radiology, nuclear medicine


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives To report the feasibility of early fetal cystoscopy for the prenatal diagnosis and therapy of severe first-trimester megacystis. Methods Between January 2008 and February 2010, early fetal cystoscopy at 16 weeks of gestation was offered to 15 patients whose fetuses presented with severe first-trimester megacystis. All infants were followed up for 6-12 months after birth. Autopsy was always performed whenever fetal or neonatal deaths occurred. Results Seven patients decided to undergo fetal therapy, and eight elected to continue with expectant observation. One fetus died before early fetal cystoscopy was performed. Therefore, six fetuses underwent early fetal cystoscopy. Urethral atresia was diagnosed in three fetuses during fetal cystoscopy and confirmed at autopsy following termination of pregnancy at 19-20 weeks in all cases. Posterior urethral valves were diagnosed and successfully fulgurated by laser during early cystoscopy in three fetuses, two of which survived with normal renal and bladder function after birth; the remaining fetus had a postnatal diagnosis of megacystis-microcolon intestinal hypoperistalsis syndrome and died neonatally. In the expectantly managed group, no survivals were observed, even among cases with `isolated` posterior urethral valves. Conclusions Percutaneous early fetal cystoscopy is feasible for prenatal diagnosis and therapy of severe megacystis. Copyright (C) 2011 ISUOG. Published by John Wiley & Sons, Ltd.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose. To build nomograms of fetal thyroid circumference (FTC), fetal thyroid area (FTA), and fetal thyroid transverse diameter (FTTD) throughout gestational age (GA). Method. Between January 2006 and July 2006, FTC, FTA, and FTTD were measured once in 196 normal fetuses examined at a GA of 22-35 weeks. Inclusion criteria were a healthy mother with normal maternal thyrotropin level during pregnancy, a singleton pregnancy with normal fetal morphology on sonography, and GA confirmed via first-trimester sonographic examination. Results. Mean FTC, FTA, and FTTD ranged from 3.21 cm, 0.58 cm(2), and 1.19 cm at 22 weeks to 5.11 cm, 1.69 cm(2), and 1.89 cm at 35 weeks, respectively. Linear regression analysis yielded the following formulas for FTC, FTA, and FTTD according to GA: FTC (cm) = 0.146 X GA (weeks); FTA (cm(2)) = -1.289 + 0.085 X GA (weeks); FTTD (cm) = 0.054 X GA (weeks). The following logarithmic formulas were obtained for the expected fetal thyroid measurements according to estimated fetal weight (FW): FTC (cm) = -4.791 + 1.265 X logN FW; FTA (cm(2)) = -1.676 + 0.455 X logN FW; and FTTD (cm) = 0.399 + 0.001 X logN FW. Conclusion. We describe new nomograms of fetal thyroid measurements throughout gestation that may be useful in case of thyroid dysfunction. (C) 2008 Wiley Periodicals, Inc.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: Intervertebral cervical disc herniation (CDH) is a relatively common disorder that can coexist with degenerative changes to worsen cervicogenic myelopathy. Despite the frequent disc abnormalities found in asymptomatic populations, magnetic resonance imaging (MRI) is considered excellent at detecting cervical spine myelopathy (CSM) associated with disc abnormality. The objective of this study was to investigate the intra- and inter-observer reliability of MRI detection of CSM in subjects who also had co-existing intervertebral disc abnormalities. Materials and methods: Seven experienced radiologists reviewed twice the MRI of 10 patients with clinically and/or imaging determined myelopathy. MRI assessment was performed individually, with and without operational guidelines. A Fleiss Kappa statistic was used to evaluate the intra- and inter-observer agreement. Results: The study found high intra-observer percent agreement but relatively low Kappa values on selected variables. Inter-observer reliability was also low and neither observation was improved with operational guidelines. We believe that those low values may be associated with the base rate problem of Kappa. Conclusion: In conclusion, this study demonstrated high intra-observer percent agreement in MR examination for intervertebral disc abnormalities in patients with underlying cervical myelopathy, but differing levels of intra- and inter-observer Kappa agreement among seven radiologists. (c) 2007 Elsevier Ireland Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose The purpose of the study was to examine the most adequate cut-off point for median nerve cross-sectional area and additional ultrasound features supporting the diagnosis of carpal tunnel syndrome (CTS). Material and methods Forty wrists from 31 CTS patients and 63 wrists from 37 asymptomatic volunteers were evaluated by ultrasound. All patients were women. The mean age was 49.1 years (range: 29-78) in the symptomatic and 45.1 years (range 24-82) in the asymptomatic group. Median nerve cross-sectional area was obtained using direct (DT) and indirect (IT) techniques. Median nerve echogenicity, mobility, flexor retinaculum measurement and the anteroposterior (AP) carpal tunnel distance were assessed. This study was IRB-approved and all patients gave informed consent prior to examination. Results In CTS the median nerve cross-sectional area was increased compared with the control group. Median nerve cross-sectional area of 10 mm(2) (DT) and 9 mm(2) (IT) had high sensitivity (85% and 88.5%, respectively), specificity (92.1% and 82.5%) and accuracy (89.3% and 82.5%) in the diagnosis of CTS. CTS patients had an increased carpal tunnel AP diameter, flexor retinaculum thickening, reduced median nerve mobility and decreased median nerve echogenicity. Conclusion Ultrasound assists in the diagnosis of CTS using the median nerve diameter cut-off point of 10 mm(2) (DT) and 9 mm(2) (IT) and several additional findings.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective. The purpose of this series was to determine the frequency of abductor mechanism avulsion by sonography after total hip arthroplasty with the Hardinge approach (J Bone Joint Surg Br 1982; 64:17-19) and its relationship to the presence of insufficiency of this musculature in the postoperative period. Methods. Thirty-four consecutive patients were prospectively accessed in the postoperative period of hip arthroplasty by the Trendelenburg test, hip sonography, and abductor muscle electromyography. In patients who were found to have clinical insufficiency of the abductor musculature, we also measured the femoral offset in the preoperative and postoperative radiographs. Hip sonography was performed by an experienced musculoskeletal radiologist blinded to the other tests, and the tendons of the gluteus medius and gluteus minimus were visualized on longitudinal and transverse sections with a 7- to 10-MHz linear transducer. Results. Eight patients presented clinical insufficiency of the abductor musculature as detected by the Trendelenburg test. Four of these 8 patients with abductor insufficiency presented tendinous avulsion detected by sonography. One of the 4 patients with abductor insufficiency and normal sonographic findings had a decrease in the femoral offset caused by the arthroplasty itself. Two patients presented electromyographic changes of the abductor musculature, with no tendinous avulsion detected by sonography and no abductor insufficiency. Conclusions. We concluded that in patients undergoing total hip arthroplasty by the Hardinge approach in whom insufficiency of the abductor musculature develops, sonography is an interesting method of investigation because it identified the cause of this problem in most of our patients.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The present study aimed to assess the reliability of intra and inter-examiner subacromial impingement index (SII) measures obtained from radiographs. Thirty-six individuals were enrolled and divided into two groups: control group, composed of 18 volunteers in good general health without shoulder problems, and a group of 18 patients with subacromial impingement syndrome (SIS). Radiographic images were taken with the dominant upper limb in neutral rotation, while the volunteers held their arm at 90A degrees of abduction in the frontal plane. The beam of radiation at 30A degrees craniocaudal inclination was used to provide an antero-posterior image view. Three blinded examiners each performed three measurements from the subacromial space (SS) and the anatomical neck of the humerus (NH). The SII was calculated as the ratio of the SS and the NH measures. The mean values of SII were compared using t-tests. The intra-class correlation coefficient (ICC) was used to assess intra- and inter-examiner reliability of the measures. The mean values of SII were greater for the control group (0.12) than for the SIS group (0.08; p = 0.0071). SII measurements showed excellent intra (0.96-0.99) and inter-examiner reliability (0.94) for both the control and SIS group. The results of this study show the potential use of the SII; a greater mean value for the control group compared to the SIS group and excellent reliability for intra- and inter-examiner measurement. Validation studies of the index should be conducted to correlate the index with clinical findings from subacromial impingement syndrome.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose We quantified variations of the lingual artery origin, measured the lingual artery origin distance from clinical relevant landmarks and compared the lingual artery diameters with normal and variable origin. Methods Forty-two formalin fixed male cadavers were bilaterally evaluated. Measurements were performed with the aid of an electronic digital caliper. Results The origin distances from the common carotid artery bifurcation was 1.05 +/- 0.11 and 1.02 +/- 0.11 cm for the right and left lingual arteries respectively with no differences compared to the lingual-facial trunks. The diameters of the lingual arteries were 0.25 +/- 0.01 and 0.26 +/- 0.01 cm for the right and left sides, respectively, while the lingual facial trunks showed diameters of 0.21 +/- 0.02 and 0.24 +/- 0.02 cm for the right and left sides, respectively. Conclusions The present study adds information on the lingual artery diameter and its anatomical relation to clinically useful landmarks.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: The purpose of our study was to compare signal characteristics and image qualities of MR imaging at 3.0 T and 1.5 T in patients with diffuse parenchymal liver disease. Materials and methods: 25 consecutive patients with diffuse parenchymal liver disease underwent abdominal MR imaging at both 3.0 T and 1.5 T within a 6-month interval. A retrospective study was conducted to obtain quantitative and qualitative data from both 3.0 T and 1.5 T MRI. Quantitative image analysis was performed by measuring the signal-to-noise ratios (SNRs) and the contrast-to-noise ratios (CNRs) by the Students t-test. Qualitative image analysis was assessed by grading each sequence on a 3- and 4-point scale, regarding the presence of artifacts and image quality, respectively. Statistical analysis consisted of the Wilcoxon signed-rank test. Results: the mean SNRs and CNRs of the liver parenchyma and the portal vein were significantly higher at 3.0 T than at 1.5 T on portal and equilibrium phases of volumetric interpolated breath-hold examination (VIBE) images (P < 0.05). The mean SNRs were significantly higher at 3.0 T than at 1.5 T on T1-weighted spoiled gradient echo (SGE) images (P < 0.05). However, there were no significantly differences on T2-weighted short-inversion-time inversion recovery (STIR) images. Overall image qualities of the 1.5 T noncontrast T1- and T2-weighted sequences were significantly better than 3.0 T (P < 0.01). In contrast, overall image quality of the 3.0 T post-gadolinium VIBE sequence was significantly better than 1.5 T (P< 0.01). Conclusions: MR imaging of post-gadolinium VIBE sequence at 3.0 T has quantitative and qualitative advantages of evaluating for diffuse parenchymal liver disease. (C) 2008 Elsevier Ireland Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective Intrasubstance meniscal signal changes not reaching the articular surface on fast spin echo (FSE) sequences are considered to represent mucoid degeneration on MRI. The aim of this study was to evaluate the association of prevalent intrasubstance signal changes with incident tears of the medial meniscus detected on 3.0 T MRI over a 1-year period. Materials and methods A total of 161 women aged a parts per thousand yen40 years participated in a longitudinal 1-year observational study of knee osteoarthritis. MRI (3.0 T) was performed at baseline and 12-month follow-up. The anterior horn, body, and posterior horn of the medial meniscus were scored by two experienced musculoskeletal radiologists using the Boston-Leeds Osteoarthritis Knee Score (BLOKS) system. Four grades were used to describe the meniscal morphology: grade 0 (normal), grade 1 (intrasubstance signal changes not reaching the articular surface), grade 2 (single tears), and grade 3 (complex tears and maceration). Fisher`s exact test and the Cochran-Armitage trend test were performed to evaluate whether baseline intrasubstance signal changes (grade 1) predict incident meniscal tears/maceration (grades 2 and/or 3) in the same subregion of the medial meniscus, when compared to subregions without pathology as the reference group (grade 0). Results Medial meniscal intrasubstance signal changes at baseline did not predict tears at follow-up when evaluating the anterior and posterior horns (left-sided p-values 0.06 and 0.59, respectively). No incident tears were detected in the body. Conclusion We could not demonstrate an association between prevalent medial meniscal intrasubstance signal changes with incident tears over a 1-year period.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective. The purpose of this study was to evaluate the diagnostic usefulness of ulnar nerve sonography in leprosy neuropathy with electrophysiologic correlation. Methods. Twenty-one consecutive patients with leprosy (12 men and 9 women; mean age +/- SD, 47.7 +/- 17.2 years) and 20 control participants (14 men and 6 women; mean age, 46.5 +/- 16.2 years) were evaluated with sonography. Leprosy diagnosis was established on the basis of clinical, bacteriologic, and histopathologic criteria. The reference standard for ulnar neuropathy in this study was clinical symptoms in patients with proven leprosy The sonographic cross-sectional areas (CSAs) of the ulnar nerve in 3 different regions were obtained. Statistical analyses included Student t tests and receiver operating characteristic curve analysis. Results. The CSAs of the ulnar nerve were significantly larger in the leprosy group than the control group for all regions (P < .01). Sonographic abnormalities in leprosy nerves included focal thickening (90.5%), hypoechoic areas (81%), loss of the fascicular pattern (33.3%), and focal hyperechoic areas (4.7%). Receiver operating characteristic curve analysis showed that a maximum CSA cutoff value of 9.8 mm(2) was the best discriminator (sensitivity, 0.91; specificity, 0.90). Three patients with normal electrophysiologic findings had abnormal sonographic findings. Two patients had normal sonographic findings, of which 1 had abnormal electrophysiologic findings, and the other refused electrophysiologic testing. Conclusions. Sonography and electrophysiology were complementary for identifying ulnar nerve neuropathy in patients with leprosy, with clinical symptoms as the reference standard. This reinforces the role of sonography in the investigation of leprosy ulnar neuropathy.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND AND PURPOSE: There are 2 main hypotheses concerning the cause of mirror movements (MM) in Kallmann syndrome (KS): abnormal development of the primary motor system, involving the ipsilateral corticospinal tract, and lack of contralateral motor cortex inhibitory mechanisms, mainly through the corpus callosum. The purpose of our study was to determine white and gray matter volume changes in a KS population by using optimized voxel-based morphometry (VBM) and to investigate the relationship between the abnormalities and the presence of MM, addressing the 2 mentioned hypotheses. MATERIALS AND METHODS: T1-weighted volumetric images from 21 patients with KS and 16 matched control subjects were analyzed with optimized VBM. Images were segmented and spatially normalized, and these deformation parameters were then applied to the original images before the second segmentation. Patients were divided into groups with and without MM, and a t test statistic was then applied on a voxel-by-voxel basis between the groups and controls to evaluate significant differences. RESULTS: When considering our hypothesis a priori, we found that 2 areas of increased gray matter volume, in the left primary motor and sensorimotor cortex, were demonstrated only in patients with MM, when compared with healthy controls. Regarding white matter alterations, no areas of altered volume involving the corpus callosum or the projection of the corticospinal tract were demonstrated. CONCLUSION: The VBM study did not show significant white matter changes in patients with KS but showed gray matter alterations in keeping with a hypertrophic response to a deficient pyramidal decussation in patients with MM. In addition, gray matter alterations were observed in patients without MM, which can represent more complex mechanisms determining the presence or absence of this symptom.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose To describe the ictal technetium-99 m-ECD SPECT findings in polymicrogyria syndromes (PMG) during epileptic seizures. Methods We investigated 17 patients with PMG syndromes during presurgical workup, which included long-term video-electroencephalographic (EEG) monitoring, neurological and psychiatry assessments, invasive EEG, and the subtraction of ictal-interictal SPECT coregistered to magnetic resonance imaging (MRI) (SISCOM). Results The analysis of the PMG cortex, using SISCOM, revealed intense hyperperfusion in the polymicrogyric lesion during epileptic seizures in all patients. Interestingly, other localizing investigations showed heterogeneous findings. Twelve patients underwent epilepsy surgery, three achieved seizure-freedom, five have worthwhile improvement, and four patients remained unchanged. Conclusions Our study strongly suggests the involvement of PMG in seizure generation or early propagation. Both conventional ictal single-photon emission computed tomography (SPECT) and SISCOM appeared as the single contributive exam to suggest the localization of the epileptogenic zone. Despite the limited number of resective epilepsy surgery in our study (n=9), we found a strong prognostic role of SISCOM in predicting surgical outcome. This result may be of great value on surgical decision-making of whether or not the whole or part of the PMG lesion should be surgically resected.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: To describe the use of 3.0-T magnetic resonance imaging (MRI) for the evaluation of chronic liver diseases. Materials and Methods: Two groups of patients who had chronic liver diseases and underwent 3.0-T MRI for evaluation of the liver were included in the study. The first group of patients included 66 consecutive patients (33 male, 33 female; mean age +/- standard deviation, 56 +/- 11). The second group of patients included 30 consecutive patients (18 males, 12 females; mean age +/- standard deviation, 53 +/- 10) in whom Variable-Rate Selective Excitation (VERSE) pulses and improved adjustments procedure were used during the acquisitions. Imaging findings of chronic liver diseases, predetermined artifacts and image quality of all individual sequences in the first group and predetermined artifacts and image quality of T2-weighted sequences in the second group were reviewed retrospectively and independently by two reviewers. chi-Square tests were used to compare the findings between two groups of patients and individual sequences. Kappa statistics were used to determine the extent of agreement between the reviewers. Results: Fifteen dysplastic nodules in 6 of 66 (9%) patients and 12 hepatocellular carcinomas in 11 of 66 (17%) patients were detected. Excluding motion artifacts, three-dimensional (313) T1-weighted gradient-echo (GE) sequence was the least affected sequence by the artifacts. Image quality of T1-weighted 3D-GE sequences was excellent in 43 of 66 (65%) patients. In-phase and out-of-phase T1-weighted spoiled GE (SGE) images were fair in 62 of 66 (94%) and 61 of 66 (92%) patients, respectively. The image quality of short tau inversion recovery (STIR) and half-Fourier rapid acquisition with relaxation enhancement (RARE) sequences were fair in 31 of 66 (47%) and 53 of 66 (80%) patients. STIR and half-Fourier RARE sequences in the second group demonstrated significantly better image quality (P=.03 and P<.0001). Conclusion: 3.0-T MRI allows the acquisition of very high quality postgadolinium 3D-GE sequence, which permitted the detection and characterization of lesions in the setting of chronic liver diseases. The use of VERSE pulses and improved adjustments procedure improved the image quality of T2-weighted sequences. In-phase/out-of-phase SGE sequences are at present of fair quality. (C) 2008 Elsevier Inc. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: To evaluate the diagnostic image quality of post-gadolinium water excitation-magnetization-prepared rapid gradient-echo (WE-MPRAGE) sequence in abdominal examinations of noncooperative patients at 1.5 Tesla (T) and 3.0T MRI. Materials and Methods: Eighty-nine consecutive patients (48 males and 41 females; mean age +/- standard deviation, 54.6 +/- 16.6 years) who had MRI examinations including postgadolinium WE-MPRAGE were included in the study. Of 89 patients, 33 underwent noncooperative protocol at 1.5T. 10 under-went noncooperative protocol at 3.0T, and 46 underwent cooperative protocol at 3.0T. Postgadolinium WE-MPRAGE, MPRAGE, and three-dimensional gradient-echo sequences of these three different groups were qualitatively evaluated for image quality, extent of artifacts, lesion conspicuity, and homogeneity of fat-attenuation by two reviewers retrospectively, independently, and blindly. The results were compared using Wilcoxon signed rank and Mann-Whitney U tests. Kappa statistics were used to measure the extent of agreement between the reviewers. Results: The average scores indicated that the images were diagnostic for WE-MPRAGE at 1.5T and 3.0T in noncooperative patients. WE-MPRAGE achieved homogenous fat-attenuation in 31/33 (94%) of noncooperative patients at 1.5T and 10/10 (100%) of noncooperative patients at 3.0T. WE-MPRAGE at 3.0T had better results for image quality, extent of artifacts, lesion conspicuity and homogeneity of fat-attenuation compared with WE-MPRAGE at 1.5T. in noncooperative patients (P = 0.0008, 0.0006, 0.0024, and 0.0042: respectively). Kappa statistics varied between 0.76 and 1.00, representing good to excellent agreement. Conclusion: WE-MPRAGE may be used as a T1-weighted postgadolinium fat-attenuated sequence in noncooperative patients, particularly at 3.0T MRI.