Water excitation MPRAGE: An alternative sequence for postcontrast imaging of the abdomen in noncooperative patients at 1.5 Tesla and 3.0 Tesla MRI


Autoria(s): ALTUN, Ersan; SEMELKA, Richard C.; DALE, Brian M.; ELIAS JR., Jorge
Contribuinte(s)

UNIVERSIDADE DE SÃO PAULO

Data(s)

19/10/2012

19/10/2012

2008

Resumo

Purpose: To evaluate the diagnostic image quality of post-gadolinium water excitation-magnetization-prepared rapid gradient-echo (WE-MPRAGE) sequence in abdominal examinations of noncooperative patients at 1.5 Tesla (T) and 3.0T MRI. Materials and Methods: Eighty-nine consecutive patients (48 males and 41 females; mean age +/- standard deviation, 54.6 +/- 16.6 years) who had MRI examinations including postgadolinium WE-MPRAGE were included in the study. Of 89 patients, 33 underwent noncooperative protocol at 1.5T. 10 under-went noncooperative protocol at 3.0T, and 46 underwent cooperative protocol at 3.0T. Postgadolinium WE-MPRAGE, MPRAGE, and three-dimensional gradient-echo sequences of these three different groups were qualitatively evaluated for image quality, extent of artifacts, lesion conspicuity, and homogeneity of fat-attenuation by two reviewers retrospectively, independently, and blindly. The results were compared using Wilcoxon signed rank and Mann-Whitney U tests. Kappa statistics were used to measure the extent of agreement between the reviewers. Results: The average scores indicated that the images were diagnostic for WE-MPRAGE at 1.5T and 3.0T in noncooperative patients. WE-MPRAGE achieved homogenous fat-attenuation in 31/33 (94%) of noncooperative patients at 1.5T and 10/10 (100%) of noncooperative patients at 3.0T. WE-MPRAGE at 3.0T had better results for image quality, extent of artifacts, lesion conspicuity and homogeneity of fat-attenuation compared with WE-MPRAGE at 1.5T. in noncooperative patients (P = 0.0008, 0.0006, 0.0024, and 0.0042: respectively). Kappa statistics varied between 0.76 and 1.00, representing good to excellent agreement. Conclusion: WE-MPRAGE may be used as a T1-weighted postgadolinium fat-attenuated sequence in noncooperative patients, particularly at 3.0T MRI.

Identificador

JOURNAL OF MAGNETIC RESONANCE IMAGING, v.27, n.5, p.1146-1154, 2008

1053-1807

http://producao.usp.br/handle/BDPI/24053

10.1002/jmri.21346

http://dx.doi.org/10.1002/jmri.21346

Idioma(s)

eng

Publicador

JOHN WILEY & SONS INC

Relação

Journal of Magnetic Resonance Imaging

Direitos

restrictedAccess

Copyright JOHN WILEY & SONS INC

Palavras-Chave #abdominal imaging #water excitation #MPRAGE #noncooperative patients #MR #3.0 T #RAPID FAT-SUPPRESSION #LESION DETECTION #BREATH #LIVER #ACQUISITION #LOCALIZATION #PULSES #CT #Radiology, Nuclear Medicine & Medical Imaging