948 resultados para Portable equipment


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: The Finometer (FMS, Finapres Measurement Systems, Amsterdam) records the beat-to-beat finger pulse contour and has been recommended for research studies assessing shortterm changes of blood pressure and its variability. Variability measured in the frequency domain using spectral analysis requires that the impact of breathing be restricted to high frequency spectra (> 0.15 Hz) so data from participants needs to be excluded when the breathing impact occurs in the low frequency spectra (0.04 - 0.15 Hz). This study tested whether breathing frequency can be estimated from standard Finometer recordings using either stroke volume oscillation frequency or spectral stroke volume variability maximum scores. Methods: 22 healthy volunteers were tested for 270s in the supine and upright positions. Finometer recorded the finger pulse contour and a respiratory transducer recorded breathing. Stoke volume oscillation frequency was calculated manually while the stroke volume spectral maximums were obtained using the software Cardiovascular Parameter Analysis (Nevrokard Kiauta, Izola, Slovenia). These estimates were compared to the breathing frequency using the Bland-Altman procedures. Results: Stroke volume oscillation frequency estimated breathing frequency to <±10% 95% levels of agreement in both supine (-7.7 to 7.0%) and upright (-6.7 to 5.4%) postures. Stroke volume variability maximum scores did not accurately estimate breathing frequency. Conclusions: Breathing frequency can be accurately derived from standard Finometer recordings using stroke volume oscillations for healthy individuals in both supine and upright postures. The Finometer can function as a standalone instrument in blood pressure variability studies and does not require support equipment to determine breathing frequency.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Certain environmental conditions in animal and plant production have been associated with increased frequency in respiratory illnesses, including asthma, chronic bronchitis, and hypersensitivity pneumonitis, in farmers occupationally exposed in swine production. The aim of this study was to characterize particulate matter (PM) contamination in seven Portuguese swine farms and determine the existence of clinical symptoms associated with asthma and other allergy diseases, utilizing the European Community Respiratory Health Survey questionnaire. Environmental assessments were performed with portable direct-reading equipment, and PM contamination including five different sizes (PM0.5, PM1.0, PM2.5, PM5.0, PM10) was determined. The distribution of particle size showed the same trend in all swine farms, with high concentrations of particles with PM5 and PM10. Results from the questionnaire indicated a trend such that subjects with diagnosis of asthma were exposed to higher concentrations of PM with larger size (PM2.5, PM5, and PM10) while subjects with sneezing, runny nose, or stuffy nose without a cold or flu were exposed to higher concentrations of PM with smaller size (PM0.5 and PM1). Data indicate that inhalation of PM in swine farm workers is associated with increased frequency of respiratory illnesses.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The presence of filamentous fungi was detected in wastewater and air collected at wastewater treatment plants (WWTP) from several European countries. The aim of the present study was to assess fungal contamination in two WWTP operating in Lisbon. In addition, particulate matter (PM) contamination data was analyzed. To apply conventional methods, air samples from the two plants were collected through impaction using an air sampler with a velocity air rate of 140 L/min. Surfaces samples were collected by swabbing the surfaces of the same indoor sites. All collected samples were incubated at 27°C for 5 to 7 d. After lab processing and incubation of collected samples, quantitative and qualitative results were obtained with identification of the isolated fungal species. For molecular methods, air samples of 250 L were also collected using the impinger method at 300 L/min airflow rate. Samples were collected into 10 ml sterile phosphate-buffered saline with 0.05% Triton X-100, and the collection liquid was subsequently used for DNA extraction. Molecular identification of Aspergillus fumigatus and Stachybotrys chartarum was achieved by real-time polymerase chain reaction (RT-PCR) using the Rotor-Gene 6000 qPCR Detection System (Corbett). Assessment of PM was also conducted with portable direct-reading equipment (Lighthouse, model 3016 IAQ). Particles concentration measurement was performed at five different sizes: PM0.5, PM1, PM2.5, PM5, and PM10. Sixteen different fungal species were detected in indoor air in a total of 5400 isolates in both plants. Penicillium sp. was the most frequently isolated fungal genus (58.9%), followed by Aspergillus sp. (21.2%) and Acremonium sp. (8.2%), in the total underground area. In a partially underground plant, Penicillium sp. (39.5%) was also the most frequently isolated, also followed by Aspergillus sp. (38.7%) and Acremonium sp. (9.7%). Using RT-PCR, only A. fumigatus was detected in air samples collected, and only from partial underground plant. Stachybotrys chartarum was not detected in any of the samples analyzed. The distribution of particle sizes showed the same tendency in both plants; however, the partially underground plant presented higher levels of contamination, except for PM2.5. Fungal contamination assessment is crucial to evaluating the potential health risks to exposed workers in these settings. In order to achieve an evaluation of potential health risks to exposed workers, it is essential to combine conventional and molecular methods for fungal detection. Protective measures to minimize worker exposure to fungi need to be adopted since wastewater is the predominant internal fungal source in this setting.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A Work Project, presented as part of the requirements for the Award of a Masters Degree in Management from the NOVA – School of Business and Economics

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Genetic algorithms regarding to life cycle management of electrotechnical equipment are considered. The concept of “techno-individual” is introduced.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Screening for obstructive sleep apnea (OSA) is recommended as part of the preoperative assessment of obese patients scheduled for bariatric surgery. The objective of this study was to compare the sensitivity of oximetry alone versus portable polygraphy in the preoperative screening for OSA. METHODS: Polygraphy (type III portable monitor) and oximetry data recorded as part of the preoperative assessment before bariatric surgery from 68 consecutive patients were reviewed. We compared the sensitivity of 3% or 4% desaturation index (oximetry alone) with the apnea-hypopnea index (AHI; polygraphy) to diagnose OSA and classify the patients as normal (<10 events per hour), mild to moderate (10-30 events per hour), or severe (>30 events per hour). RESULTS: Using AHI, the prevalence of OSA (AHI > 10 per hour) was 57.4%: 16.2% of the patients were classified as severe, 41.2% as mild to moderate, and 42.6% as normal. Using 3% desaturation index, 22.1% were classified as severe, 47.1% as mild to moderate, and 30.9% as normal. With 4% desaturation index, 17.6% were classified as severe, 32.4% as mild, and 50% as normal. Overall, 3% desaturation index compared to AHI yielded a 95% negative predictive value to rule out OSA (AHI > 10 per hour) and a 100% sensitivity (0.73 positive predictive value) to detect severe OSA (AHI > 30 per hour). CONCLUSIONS: Using oximetry with 3% desaturation index as a screening tool for OSA could allow us to rule out significant OSA in almost a third of the patients and to detect patients with severe OSA. This cheap and widely available technique could accelerate preoperative work-up of these patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A photograph negative of Donald Ziraldo working a machine.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Letter containing a handwritten list of prices for items such as tripods and sockets sent to Mr. S.D. Woodruff from Troughton and Simms of Fleet Street, London, England, Feb.23, 1846.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Letter of estimate sent to S.D. Woodruff for the total cost of construction and equipment of the extension of the line to Port Colborne [this is unsigned]. There is an envelope with this letter that suggests that it is from Mr. Shanly, Mar. 12, 1857.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mémoire numérisé par la Division de la gestion de documents et des archives de l'Université de Montréal

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Design of a compact microstrip-fed ultra-wideband antenna suitable for USB dongle and other such space constraint applications is presented. The structure consists of a pentagonal monopole element and a modified ground plane that gives an impedance bandwidth from 2.8 to 12 GHz. Radiation patterns are stable and omni-directional throughout the band with an average gain of 2.84 dBi. The antenna occupies only 11 × 30 mm2 on FR4 substrate with permittivity 4.4.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Short set of slides explaining the workflow from a university website to equipment.data.ac.uk

Relevância:

20.00% 20.00%

Publicador:

Resumo:

La ciencia en la escuela primaria resulta cada vez más solicitada, por ello los maestros deben aprender a elegir entre una gama de equipos cada vez más sofisticados. El objetivo es ayudar a los docentes en su tarea de garantizar que los niños accedan a un equipamiento científico adecuado,y que las escuelas desarrollen una política progresista en el suministro, uso y cuidado de estos aparatos.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Na fábrica da EPAL, em Vale da Pedra, o risco de queda em altura no acesso vertical a espaços confinados, foi avaliado como sendo aceitável mediante a adoção de medidas de controlo que não existiam, ou que não eram adequadas, ou ainda que não eram utilizadas. Para responder a este problema, foi concebido, desenvolvido e ensaiado um inovador dispositivo portátil anti-queda. Este previne a queda no acesso entre o pavimento e os primeiros degraus de aberturas verticais conducentes a espaços confinados. Além da função preventiva, também pode fazer parte da proteção anti-queda, como ponto de ancoragem dos equipamentos de proteção contra quedas. Os ensaios realizados revelaram que, em comparação com as alternativas pré-fabricadas disponíveis, esta solução é mais adequada para prevenir quedas, por se adaptar a múltiplas configurações de acesso, com um dispositivo relativamente leve, fácil de transportar e de aplicar, estável e resistente. / In EPAL factory in Vale da Pedra, the risk of falling from a height in the vertical access to confined spaces, was evaluated as being acceptable by the adoption of control measures that did not exist, or were not suitable, or were not used. To respond to this problem, an innovative portable anti-falling device was designed, developed and tested. This prevents falling in access between the ground and the first steps of vertical openings leading to confined spaces. In addition to the preventive function, it can also be part of the fall-arrest protection, as anchor point of fall protection equipment. The tests revealed that, in comparison with the prefabricated alternatives available, this solution is best suited to prevent falls, due to its adaptability to multiple access settings, with a relatively light device, easy to carry and to use, stable and resistant.