984 resultados para PRESSURE ULCER


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to determine whether age influences the concordance between different methods of blood pressure (BP) measurement and ambulatory BP monitoring (ABPM) in hypertensive subjects. We studied two groups: I, individuals younger than 50 years (n = 57), and II, individuals aged 60 years or older (n = 55). They were submitted to the performance of one ABPM, office BP measurements, home BP monitoring (HBPM), and BP measurements at a public health center (PHCBP). Student`s t-test, Fisher`s test and Lin coefficient were calculated. For Group II, systolic and diastolic pressures measured by HBPM were higher than by day ABPM (p < 0.01). The concordance between day ABPM and the other methods was lower for Group II than for Group I. There was a good concordance between systolic day ABPM and office BP, and between systolic ABPM and PHCBP only for Group I (Lin coefficient = 0.71 and 0.73). Group II reported better sleep quality after ABPM (p < 0.05). Considering 24-h ABPM, 52.6% of Group I and 29% of Group II were controlled (p < 0.01). Concluding, there was worse concordance between different methods of BP measurements and day ABPM in the older group, which had lower hypertension control rate and better tolerance of ABPM. (C) 2009 Elsevier Ireland Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work provides experimental phase diagram of mitotane, a drug used in the chemotherapy treatment of adrenocortical carcinoma, in compressed and/or supercritical CO(2). The synthetic-static method in a high-pressure variable-volume view cell coupled with a transmitted-light intensity probe was used to measure the solid-fluid (SF) equilibrium data. The phase equilibrium experiments were determined in temperature ranging from (298.2 to 333.1) K and pressure up to 22 MPa. Peng-Robinson equation of state (PR-EoS) with classical mixing rule was used to correlate the experimental data. Excellent agreement was found between experimental and calculated values. (C) 2009 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Microalbuminuria and hypertension have long been associated with a guarded prognosis in human patients with a variety of diseases. In veterinary medicine, tests for microalbuminuria have been used for detecting early kidney damage, but there is little information regarding its association with high blood pressure in dogs with chronic kidney disease (CKD). Objective The objective of this study was to evaluate albuminuria and its association with arterial hypertension in dogs with CKD. Methods Urinary albumin:creatinine (UAC) ratio, urinary protein:creatinine (UPC) ratio, and systolic blood pressure were determined in 39 clinically healthy dogs and 40 dogs with CKD. Results UAC in dogs with CKD (range, 0.002-7.99; median, 0.38) was statistically different from that of control dogs (range, 0.0005-0.01; median, 0.002). Microalbuminuria (UAC 0.03-0.3) and macroalbuminuria (UAC > 0.3) were detected in 32.5% and 50% of dogs with CKD, respectively. Sixty percent (24/40) of dogs with CKD had systolic pressure >= 180 mmHg; in these dogs, UAC ratio (range, 0.006-7.99; median, 1.72) was significantly higher than in dogs with CKD and systolic pressure < 180 mmHg (range, 0.002-4.83; median, 0.10). Of hypertensive dogs with CKD, those with UPC > 1.0 usually had macroalbuminuria, those with UPC 0.5-1.0 usually had microalbuminuria, and those with UPC < 0.5 usually lacked albuminuria. Conclusions UAC ratio was higher in hypertensive than in normotensive dogs with CKD. Tests designed to detect microalbuminuria may be useful for hypertensive dogs with CKD and a UPC < 1.0 to detect the onset and magnitude of albuminuria. Once macroalbuminuria is overt, the UPC ratio itself can be used for the same purpose.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to evaluate the influence of stress and anxiety on the pressure pain threshold (PPT) of masticatory muscles and on the subjective pain report. Forty-five women, students, with mean age of 19.75 years, were divided into two groups: group 1:29 presenting with masticatory myofascial pain (MFP), according to the Research Diagnostic Criteria for Temporomandibular Disorders and group 2: 16 asymptomatic controls. An electronic algometer registered the pain thresholds on four different occasions throughout the academic year. To measure levels of stress, anxiety and pain, the Beck Anxiety Inventory, Lipp Stress Symptoms Inventory and Visual Analog Scale (VAS) were used. Three-way anova and Tukey`s tests were used to verify differences in PPT between groups, times and sites. Levels of anxiety and VAS were compared using Mann-Whitney test, while Friedman`s test was used for the within-groups comparison at different times (T1 to T4). The chi-squared and Cochran tests were performed to compare groups for the proportion of subjects with stress (alpha = 0.05). Differences in PPT recordings between time (P = 0.001) and sites (P < 0.001) were detected. Higher levels of anxiety and lower PPT figures were detected at T2 (academic examination) (P = 0.001). There was no difference between groups for anxiety and stress at any time (P > 0.05). The MFP group also has shown significant increase of VAS at the time of academic examination (P < 0.001). External stressors such as academic examinations have a potential impact on masticatory muscle tenderness, regardless of the presence of a previous condition such as masticatory myofascial pain.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective. The aim of this study was to investigate the influence of the menstrual cycle and oral contraceptive (OC) intake on the pressure pain threshold (PPT) of masticatory muscles in patients with masticatory myofascial pain (MFP). Study design. The sample was composed of 36 women, divided into 4 groups, according to the presence of MFP and the intake of OC (15 patients had MFP [7 taking OC] and 21 were pain-free controls [8 taking OC]). The algometer-based PPT of masseter and temporalis, and the record of subjective pain by visual analog scale (VAS) were determined during 2 consecutives menstrual cycles at 4 phases (menstrual, follicular, periovulatory, and luteal). A 3-way ANOVA for repeated measurements, Kruskal-Wallis, Friedman, and Dunn tests, with a 5% significant level analyzed the data. Results. PPT was significantly lower in MFP patients when compared with controls throughout the experiment (P < .001). The menstrual phases did not influence PPT (P > .05), while the intake of OC seems to raise PPT levels for the left temporalis (P = .01) and right masseter (P = .04). VAS was, in general, higher at the menstrual phase Conclusions. Different phases of the menstrual cycle have no influence on PPT values, regardless of the presence of a previous condition, as masticatory myofascial pain, while the intake of OC is associated with decreased levels of reported pain.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A significant loss in electron probe current can occur before the electron beam enters the specimen chamber of an environmental scanning electron microscope (ESEM). This loss results from electron scattering in a gaseous jet formed inside and downstream (above) the pressure-limiting aperture (PLA), which separates the high-pressure and high-vacuum regions of the microscope. The electron beam loss above the PLA has been calculated for three different ESEMs, each with a different PLA geometry: an ElectroScan E3, a Philips XL30 ESEM, and a prototype instrument. The mass thickness of gas above the PLA in each case has been determined by Monte Carlo simulation of the gas density variation in the gas jet. It has been found that the PLA configurations used in the commercial instruments produce considerable loss in the electron probe current that dramatically degrades their performance at high chamber pressure and low accelerating voltage. These detrimental effects are minimized in the prototype instrument, which has an optimized thin-foil PLA design.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

There are many methods for the analysis and design of embedded cantilever retaining walls. They involve various different simplifications of the pressure distribution to allow calculation of the limiting equilibrium retained height and the bending moment when the retained height is less than the limiting equilibrium value, i.e. the serviceability case. Recently, a new method for determining the serviceability earth pressure and bending moment has been proposed. This method makes an assumption defining the point of zero net pressure. This assumption implies that the passive pressure is not fully mobilised immediately below the excavation level. The finite element analyses presented in this paper examine the net pressure distribution on walls in which the retained height is less, than the limiting equilibrium value. The study shows that for all practical walls, the earth pressure distributions on the front and back of the wall are at their limit values, Kp and K-a respectively, when the lumped factor of safety F-r is less than or equal to2.0. A rectilinear net pressure distribution is proposed that is intuitively logical. It produces good predictions of the complete bending moment diagram for walls in the service configuration and the proposed method gives results that have excellent agreement with centrifuge model tests. The study shows that the method for determining the serviceability bending moment suggested by Padfield and Mair(1) in the CIRIA Report 104 gives excellent predictions of the maximum bending moment in practical cantilever walls. It provides the missing data that have been needed to verify and justify the CIRIA 104 method.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Palpation for tenderness forms an important part of the manual therapy assessment for musculoskeletal dysfunction, In conjunction with other testing procedures it assists in establishing the clinical diagnosis. Tenderness in the thoracic spine has been reported in the literature as a clinical feature in musculoskeletal conditions where pain and dysfunction are located primarily in the upper quadrant. This study aimed to establish whether pressure pain thresholds (PPTs) of the mid-thoracic region of asymptomatic subjects were naturally lower than those of the cervical and lumbar areas. A within-subject study design was used to examine PPT at four spinal levels C6, T4, T6, and L4 in 50 asymptomatic volunteers. Results showed significant (P < 0.001) regional differences. PPT values increased in a caudal direction. The cervical region had the lowest PPT scores, that is was the most tender. Values increased in the thoracic region and were highest in the lumbar region. This study contributes to the normative data on spinal PPT values and demonstrates that mid-thoracic tenderness relative to the cervical spine is not a normal finding in asymptomatic subjects. (C) 2001 Harcourt Publishers Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Expansion tubes operating at total flow enthalpies of 100 MJ kg(-1) or more have characteristical test times of 30-50 mus. Under these conditions, the response time of the Pitot pressure measuring device is critical when performing flow calibration studies. The conventional technique of using a commercial pressure transducer protected by shielding has not always proven to be effective, due to the relatively large (and variable) response time caused by the shielding. A device called the stress wave bar gauge has been designed and calibrated and shown to be an effective way to measure the Pitot pressure with a response time of only 2-3 mus.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper, we develop a theory for diffusion and flow of pure sub-critical adsorbates in microporous activated carbon over a wide range of pressure, ranging from very low to high pressure, where capillary condensation is occurring. This theory does not require any fitting parameter. The only information needed for the prediction is the complete pore size distribution of activated carbon. The various interesting behaviors of permeability versus loading are observed such as the maximum permeability at high loading (occurred at about 0.8-0.9 relative pressure). The theory is tested with diffusion and flow of benzene through a commercial activated carbon, and the agreement is found to be very good in the light that there is no fitting parameter in the model. (C) 2001 Elsevier Science B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

1. An elevation in blood pressure has been consistently observed 24 h after adrenocorticotropic hormone (ACTH) administration and is caused by increased ACTH-stimulated cortisol secretion, in association with increased cardiac output. The aim of the present study was to investigate the previously undefined time of onset of this increase in blood pressure in normal humans. 2. Ten normal healthy volunteers received 250 mug ACTH-[1-24], in 500 mL normal saline, infused at a constant rate over 8 h. Six subjects also received a placebo infusion (normal saline only). Blood pressure, heart rate and cortisol levels were determined hourly. Adrenocorticotropic hormone (ACTH-[1-24] plus native ACTH) was measured at 0, 1, 7 and 8 h. 3. Infusion of ACTH-[1-24] produced maximal secretion rates of cortisol, resulting in a mean peak plasma level of 985 +/- 46 nmol/L at 8 h. In response, blood pressure and heart rate rose significantly by 2 h and remained generally elevated for the duration of the infusion. 4. The early onset of haemodynamic responses is consistent with classical steroid receptor-mediated genomic mechanisms, but could be due non-genomic mechanisms. 5. The cardiovascular consequences of therapeutic use of ACTH are well recognized. This results of the present study suggest that even diagnostic administration of ACTH, delivered over a few hours, may raise blood pressure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In a prospective study 105 patients with symptoms of stress incontinence underwent video-urodynamic testing, including resting urethral pressure profilometry and translabial ultrasound. The urethral pressure profile (UPP) included maximum urethral closure pressure (MUCP), functional length (FL) and area under the curve (AUC). Ultrasound parameters included urethral thickness, urethral rotation and bladder neck descent, as well as funneling/opening of the internal urethral meatus on Valsalva maneuver. Levator contraction strength was assessed measuring the cranioventral displacement of the internal meatus. Negative correlations between UPP data and age, parity and previous surgery were observed which were consistent with literature data. There was a positive correlation :between the urethral AP diameter on ultrasound and the MUCP, which agrees with reports showing reduced sphincter thickness or volume in stress-incontinent women. Hypermobility on ultrasound did not correlate with UPP data. However, a lower MUCP correlated with extensive opening of the bladder neck. Finally, there was a trend towards poorer pelvic floor function with lower MUCP measurements.