923 resultados para PHYSICAL RADIATION EFFECTS


Relevância:

80.00% 80.00%

Publicador:

Resumo:

The radiation environment of space presents a significant threat to the reliability of nonvolatile memory technologies. Ionizing radiation disturbs the charge stored on floating gates, and cosmic rays can permanently damage thin oxides. A new memory technology based on the magnetic tunneling junction (MTJ) appears to offer superior resistance to radiation effects and virtually unlimited write endurance. A magnetic flip flop has a number of potential applications, such as the configuration memory in field-programmable logic devices. However, using MTJs in a flip flop requires radically different circuitry for storing and retrieving data. New techniques are needed to insure that magnetic flip flops are reliable in the radiation environment of space. We propose a new radiation-tolerant magnetic flip flop that uses the inherent resistance of the MTJ to increase its immunity to single event upset and employs a robust “Pac-man” magnetic element.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The Howard B. Hamilton, MD, papers, MS 66, includes material from 1945-1997 related to the Atomic Bomb Casualty Commission (ABCC) and the Radiation Effects Research Foundation (RERF). Hamilton was the Chief of Clinical Laboratories for the Atomic Bomb Casualty Commission from 1956 until its dissolution in 1975. He served in the same capacity for the Radiation Effects Research Foundation, which succeeded the ABCC, until 1984. This collection encompasses this period of time in Dr. Hamilton's career, as well as his related scholarly work after his retirement from RERF. Dr. Hamilton donated his collection of letters, reprints, newspaper articles, photographs, memos, and ephemera to the John P. McGovern Historical Collections and Research Center between 1985 and 2002. The collection is in good condition and consists of 3.75 cubic feet (10 boxes).

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Bioseguridad en un sentido amplio es definida como: vida libre de peligros. Medidas de bioseguridad son acciones que contribuyen para la seguridad de la vida, en el dia a dia de las personas (ej. Cinturon de seguridad, senda peatonal). Las normas de bioseguridad engloban todas las medidas que buscan evitar riesgos fisicos (radiacion o temperatura), ergonomicos (posturales), quimicos (sustancias toxicas), biologicos (agentes infecciosos) y psicologicos (como el estres). Cada tanto, cuando hay conflictos gremiales, aparecen en las noticias hospitales que tienen ratas o cucarachas, y recien ahi se toman algunas medidas correctivas, per0 la mayoria de las instalaciones de servicios de salud no cuentan con servicios de control de plagas, o si 10s tienen no son efectivos, mas por causas administrativas que tecnicas. Es inadmisible la presencia de invertebrados y vertebrados (no humanos) en hospitales y centros de salud. Se proponen algunas medidas para mejorar la bioseguridad en esas instalaciones.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

SRAM-based FPGAs are sensitive to radiation effects. Soft errors can appear and accumulate, potentially defeating mitigation strategies deployed at the Application Layer. Therefore, Configuration Memory scrubbing is required to improve radiation tolerance of such FPGAs in space applications. Virtex FPGAs allow runtime scrubbing by means of dynamic partial reconfiguration. Even with scrubbing, intra-FPGA TMR systems are subjected to common-mode errors affecting more than one design domain. This is solved in inter-FPGA TMR systems at the expense of a higher cost, power and mass. In this context, a self-reference scrubber for device-level TMR system based on Xilinx Virtex FPGAs is presented. This scrubber allows for a fast SEU/MBU detection and correction by peer frame comparison without needing to access a golden configuration memory

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Kinetic Monte Carlo (KMC) is a widely used technique to simulate the evolution of radiation damage inside solids. Despite de fact that this technique was developed several decades ago, there is not an established and easy to access simulating tool for researchers interested in this field, unlike in the case of molecular dynamics or density functional theory calculations. In fact, scientists must develop their own tools or use unmaintained ones in order to perform these types of simulations. To fulfil this need, we have developed MMonCa, the Modular Monte Carlo simulator. MMonCa has been developed using professional C++ programming techniques and has been built on top of an interpreted language to allow having a powerful yet flexible, robust but customizable and easy to access modern simulator. Both non lattice and Lattice KMC modules have been developed. We will present in this conference, for the first time, the MMonCa simulator. Along with other (more detailed) contributions in this meeting, the versatility of MMonCa to study a number of problems in different materials (particularly, Fe and W) subject to a wide range of conditions will be shown. Regarding KMC simulations, we have studied neutron-generated cascade evolution in Fe (as a model material). Starting with a Frenkel pair distribution we have followed the defect evolution up to 450 K. Comparison with previous simulations and experiments shows excellent agreement. Furthermore, we have studied a more complex system (He-irradiated W:C) using a previous parametrization [1]. He-irradiation at 4 K followed by isochronal annealing steps up to 500 K has been simulated with MMonCa. The He energy was 400 eV or 3 keV. In the first case, no damage is associated to the He implantation, whereas in the second one, a significant Frenkel pair concentration (evolving into complex clusters) is associated to the He ions. We have been able to explain He desorption both in the absence and in the presence of Frenkel pairs and we have also applied MMonCa to high He doses and fluxes at elevated temperatures. He migration and trapping dominate the kinetics of He desorption. These processes will be discussed and compared to experimental results. [1] C.S. Becquart et al. J. Nucl. Mater. 403 (2010) 75

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Helium retention in irradiated tungsten leads to swelling, pore formation, sample exfoliation and embrittlement with deleterious consequences in many applications. In particular, the use of tungsten in future nuclear fusion plants is proposed due to its good refractory properties. However, serious concerns about tungsten survivability stems from the fact that it must withstand severe irradiation conditions. In magnetic fusion as well as in inertial fusion (particularly with direct drive targets), tungsten components will be exposed to low and high energy ion (helium) irradiation, respectively. A common feature is that the most detrimental situations will take place in pulsed mode, i.e., high flux irradiation. There is increasing evidence on a correlation between a high helium flux and an enhancement of detrimental effects on tungsten. Nevertheless, the nature of these effects is not well understood due to the subtleties imposed by the exact temperature profile evolution, ion energy, pulse duration, existence of impurities and simultaneous irradiation with other species. Physically based Kinetic Monte Carlo is the technique of choice to simulate the evolution of radiation-induced damage inside solids in large temporal and space scales. We have used the recently developed code MMonCa (Modular Monte Carlo simulator), presented in this conference for the first time, to study He retention (and in general defect evolution) in tungsten samples irradiated with high intensity helium pulses. The code simulates the interactions among a large variety of defects and impurities (He and C) during the irradiation stage and the subsequent annealing steps. In addition, it allows us to vary the sample temperature to follow the severe thermo-mechanical effects of the pulses. In this work we will describe the helium kinetics for different irradiation conditions. A competition is established between fast helium cluster migration and trapping at large defects, being the temperature a determinant factor. In fact, high temperatures (induced by the pulses) are responsible for large vacancy cluster formation and subsequent additional trapping with respect to low flux irradiation.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Three separate scenarios of an electrodynamic tether mission at Jupiter following capture of a spacecraft (SC) into an equatorial, highly elliptical orbit around the planet, with perijove at about 1.5 times the Jovian radius, are discussed. Repeated application of Lorentz drag on the spinning tether, at the perijove vicinity, can progressively lower the apojove. One mission involves the tethered-SC rapidly and frequently visiting Galilean moons; elliptical orbits with apojove down at the Ganymede, Europa, and Io orbits are in 2:5, 4:9, and 1:2 resonances with the respective moons. About 20 slow flybys of Io would take place before the accumulated radiation dose exceeds 3 Mrad (Si) at 10 mm Al shield thickness, with a total duration of 5 months after capture (4 months for lowering the apojove to Io and one month for the flybys). The respective number of flybys for Ganymede would be 10 with a total duration of about 9 months. An alternative mission would have the SC acquire a low circular orbit around Jupiter, below the radiation belts, and manoeuvre to get an optimal altitude, with no major radiation effects, in less than 5 months after capture. In a third mission, repeated thrusting at the apojove vicinity, once down at the Io torus, would raise the perijove itself to the torus to acquire a low circular orbit around Io in about 4 months, for a total of 8 months after capture; this corresponds, however, to over 100 apojove passes with an accumulated dose, of about 8.5 Mrad (Si), that poses a critical issue.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

SRAM-based FPGAs are in-field reconfigurable an unlimited number of times. This characteristic, together with their high performance and high logic density, proves to be very convenient for a number of ground and space level applications. One drawback of this technology is that it is susceptible to ionizing radiation, and this sensitivity increases with technology scaling. This is a first order concern for applications in harsh radiation environments, and starts to be a concern for high reliability ground applications. Several techniques exist for coping with radiation effects at user application. In order to be effective they need to be complemented with configuration memory scrubbing, which allows error mitigation and prevents failures due to error accumulation. Depending on the radiation environment and on the system dependability requirements, the configuration scrubber design can become more or less complex. This paper classifies and presents current and novel design methodologies and architectures for SRAM-based FPGAs, and in particular for Xilinx Virtex-4QV/5QV, configuration memory scrubbers.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

For 50 years, the Atomic Bomb Casualty Commission (ABCC) and its successor, the Radiation Effects Research Foundation (RERF), have conducted epidemiological and genetic studies of the survivors of the atomic bombs and of their children. This research program has provided the primary basis for radiation health standards. Both ABCC (1947–1975) and RERF (1975 to date) have been a joint enterprise of the United States (through the National Academy of Sciences) and of Japan. ABCC began in devastated, occupied Japan. Its mission had to be defined and refined. Early research revealed the urgent need for long term study. In 1946, a Directive of President Truman enjoined the National Research Council of the National Academy of Sciences to develop the program. By 1950, ABCC staff exceeded 1,000, and clinical and genetic studies were underway. Budgetary difficulties and other problems almost forced closure in 1953. In 1955, the Francis Report led to a unified epidemiological study. Much progress was made in the next decade, but changing times required founding of a binational nonprofit organization (RERF) with equal participation by Japan and the United States. New programs have been developed and existing ones have been extended in what is the longest continuing health survey ever undertaken.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Integrity assurance of configuration data has a significant impact on microcontroller-based systems reliability. This is especially true when running applications driven by events which behavior is tightly coupled to this kind of data. This work proposes a new hybrid technique that combines hardware and software resources for detecting and recovering soft-errors in system configuration data. Our approach is based on the utilization of a common built-in microcontroller resource (timer) that works jointly with a software-based technique, which is responsible to periodically refresh the configuration data. The experiments demonstrate that non-destructive single event effects can be effectively mitigated with reduced overheads. Results show an important increase in fault coverage for SEUs and SETs, about one order of magnitude.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Mode of access: Internet.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Title from cover.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The superior properties of ferritic/martensitic steels in a radiation environment (low swelling, low activation under irradiation and good corrosion resistance) make them good candidates for structural parts in future reactors and spallation sources. While it cannot substitute for true reactor experiments, irradiation by charged particles from accelerators can reduce the number of reactor experiments and support fundamental research for a better understanding of radiation effects in materials. Based on the nature of low energy accelerator experiments, only a small volume of material can be uniformly irradiated. Micro and nanoscale post irradiation tests thus have to be performed. We show here that nanoindentation and micro-compression testing on T91 and HT-9 stainless steel before and after ion irradiation are useful methods to evaluate the radiation induced hardening.