990 resultados para Measuring parameters
Resumo:
Background Accurate diagnosis of portal vein (PV) stenosis by real-time and color Doppler US (CD-US) after segmental liver transplantation in children can decrease morbidity by avoiding unnecessary biopsy, PV hypertension, thrombosis and loss of the graft. Objective To evaluate CD-US parameters for the prediction of PV stenosis after segmental liver transplantation in children. Materials and methods We retrospectively reviewed 61 CD-US examinations measuring the diameter at the PV anastomosis, velocities at the anastomosis (PV1) and in the segment proximal to the anastomosis (PV2), and the PV1/PV2 velocity ratio. The study group comprised patients with stenosis confirmed by angiography and the control group comprised patients with a good clinical outcome. Results PV stenosis was seen in 12 CD-US examinations. The mean PV diameter was smaller in the study group (2.6 mm versus 5.7 mm) and a PV diameter of < 3.5 mm was highly predictive of stenosis (sensitivity 100%, specificity 91.8%). Conclusion A PV diameter of < 3.5 mm is a highly predictive CD-US parameter for the detection of hemodynamically significant stenosis on angiography.
Resumo:
We have previously shown that H-1 pulsed-field-gradient (PFG) NMR spectroscopy provides a facile method for monitoring protein self-association and can be used, albeit with some caveats, to measure the apparent molecular mass of the diffusant [Dingley et al. (1995) J. Biomol. NMR, 6, 321-328]. In this paper we show that, for N-15-labelled proteins, selection of H-1-N-15 multiple-quantum (MQ) coherences in PFG diffusion experiments provides several advantages over monitoring H-1 single-quantum (SQ) magnetization. First, the use of a gradient-selected MQ filter provides a convenient means of suppressing resonances from both the solvent and unlabelled solutes. Second, H-1-N-15 zero-quantum coherence dephases more rapidly than H-1 SQ coherence under the influence of a PFG. This allows the diffusion coefficients of larger proteins to be measured more readily. Alternatively, the gradient length and/or the diffusion delay may be decreased, thereby reducing signal losses from relaxation. In order to extend the size of macromolecules to which these experiments can be applied, we have developed a new MQ PFG diffusion experiment in which the magnetization is stored as longitudinal two-spin order for most of the diffusion period, thus minimizing sensitivity losses due to transverse relaxation and J-coupling evolution.
Resumo:
For a pair of non-Hermitian Hamiltonian H and its Hermitian adjoint H(dagger), there are situations in which their eigenfunctions form a biorthogonal system. We illustrate such a situation by means of a one-particle system with a one-dimensional point interaction in the form of the Fermi pseudo-potential. The interaction consists of three terms with three strength parameters g(i) (i = 1, 2 and 3), which are all complex. This complex point interaction is neither Hermitian nor PT-invariant in general. The S-matrix for the transmission reflection problem constructed with H (or with H(dagger)) in the usual manner is not unitary, but it conforms to the pseudo-unitarity that we define. The pseudounitarity is closely related to the biorthogonality of the eigenfunctions. The eigenvalue spectrum of H with the complex interaction is generally complex but there are cases where the spectrum is real. In such a case H and H(dagger) form a pseudo-Hermitian pair.
Resumo:
Particulate matter, especially PM2.5, is associated with increased morbidity and mortality from respiratory diseases. Studies that focus on the chemical composition of the material are frequent in the literature, but those that characterize the biological fraction are rare. The objectives of this study were to characterize samples collected in Sao Paulo, Brazil on the quantity of fungi and endotoxins associated with PM2.5, correlating with the mass of particulate matter, chemical composition and meteorological parameters. We did that by Principal Component Analysis (PCA) and multiple linear regressions. The results have shown that fungi and endotoxins represent significant portion of PM2.5, reaching average concentrations of 772.23 spores mu g(-1) of PM2.5 (SD: 400.37) and 5.52 EU mg(-1) of PM2.5 (SD: 4.51 EU mg(-1)), respectively. Hyaline basidiospores, Cladosporium and total spore counts were correlated to factor Ba/Ca/Fe/Zn/K/Si of PM2.5 (p < 0.05). Genera Pen/Asp were correlated to the total mass of PM2.5 (p < 0.05) and colorless ascospores were correlated to humidity (p < 0.05). Endotoxin was positively correlated with the atmospheric temperature (p < 0.05). This study has shown that bioaerosol is present in considerable amounts in PM2.5 in the atmosphere of Sao Paulo, Brazil. Some fungi were correlated with soil particle resuspension and mass of particulate matter. Therefore, the relative contribution of bioaerosol in PM2.5 should be considered in future studies aimed at evaluating the clinical impact of exposure to air pollution. (C) 2010 Elsevier Ltd. All rights reserved.
Resumo:
Photodynamic therapy requires a photosensitizer, oxygen, and activating light. For acne, pilosebaceous units are ""target"" structures. Porphyrins are synthesized in vivo from 5-aminolevulinic acid (ALA), particularly in pilosebaceous units. Different photosensitizers and drug delivery methods have been reported for acne treatment. There are a variety of porphyrin precursors with different pharmacokinetic properties. Among them, ALA and methyl-ester of ALA (MAT.) are available for possible off-label treatment of acne vulgaris. In addition, various light sources, light dosimetry, drug incubation time, and pre- and posttreatment care also change efficacy and side effects. None of these variables has been optimized for acne treatment, but a number of clinical trials provide helpful guidance. In this paper, we critically analyze clinical trials, case reports, and series of cases published through 2009. (J Am Acad Dermatol 2010;63:195-211.)
Resumo:
To evaluate the effects of heat acclimation on sweat rate redistribution and thermodynamic parameters, 9 tropical native volunteers were submitted to 11 days of exercise-heat exposures (40 +/- 0 degrees C and 45.1 +/- 0.2% relative humidity). Sudomotor function was evaluated by measuring total and local (forehead, chest, arm, forearm, and thigh) sweat rates, local sweat sodium concentration, and mean skin and rectal temperatures. We also calculated heat production (H), heat storage (S), heat exchange by radiation (R) and by convection (C), evaporated sweat (E(sw)), sweating efficiency (eta(sw)), skin wettedness (w(sk)), and the ratio between the heat storage and the sum of heat production and heat gains by radiation and convection (S/(H+R+C)). The heat acclimation increased the whole-body sweat rate and reduced the mean skin temperature. There were changes in the local sweat rate patterns: on the arm, forearm, and thigh it increased significantly from day 1 to day 11 (all p<0.05) and the sweat rates from the forehead and the chest showed a small nonsignificant increase (p=0.34 and 0.17, respectively). The relative increase of local sweat rates on day 11 was not different among the sites; however, when comparing the limbs (arm, forearm, and thigh) with the trunk (forehead and chest), there was a significant higher increase in the limbs (32 +/- 5%) in comparison to the trunk (11 +/- 2%, p=0.001). After the heat acclimation period we observed higher w(sk) and E(sw) and reduced S/(H+R+C), meaning greater thermoregulatory efficiency. The increase in the limb sweat rate, but not the increase in the trunk sweat rate, correlated with the increased w(sk), E(sw), and reduced S/(H+R+C) (p<0.05 to all). Altogether, it can be concluded that heat acclimation increased the limbs` sweat rates in tropical natives and that this increase led to increased loss of heat through evaporation of sweat and this higher sweat evaporation was related to higher thermoregulatory efficiency. J Physiol Anthropol 29(1): 1-12, 2010 http://www.jstage.jst.go.jp/browse/jpa2 [DOI: 10.2114/jpa2.29.1]
Resumo:
Aims We conducted a meta-analysis to evaluate the accuracy of quantitative stress myocardial contrast echocardiography (MCE) in coronary artery disease (CAD). Methods and results Database search was performed through January 2008. We included studies evaluating accuracy of quantitative stress MCE for detection of CAD compared with coronary angiography or single-photon emission computed tomography (SPECT) and measuring reserve parameters of A, beta, and A beta. Data from studies were verified and supplemented by the authors of each study. Using random effects meta-analysis, we estimated weighted mean difference (WMD), likelihood ratios (LRs), diagnostic odds ratios (DORs), and summary area under curve (AUC), all with 95% confidence interval (0). Of 1443 studies, 13 including 627 patients (age range, 38-75 years) and comparing MCE with angiography (n = 10), SPECT (n = 1), or both (n = 2) were eligible. WMD (95% CI) were significantly less in CAD group than no-CAD group: 0.12 (0.06-0.18) (P < 0.001), 1.38 (1.28-1.52) (P < 0.001), and 1.47 (1.18-1.76) (P < 0.001) for A, beta, and A beta reserves, respectively. Pooled LRs for positive test were 1.33 (1.13-1.57), 3.76 (2.43-5.80), and 3.64 (2.87-4.78) and LRs for negative test were 0.68 (0.55-0.83), 0.30 (0.24-0.38), and 0.27 (0.22-0.34) for A, beta, and A beta reserves, respectively. Pooled DORs were 2.09 (1.42-3.07), 15.11 (7.90-28.91), and 14.73 (9.61-22.57) and AUCs were 0.637 (0.594-0.677), 0.851 (0.828-0.872), and 0.859 (0.842-0.750) for A, beta, and A beta reserves, respectively. Conclusion Evidence supports the use of quantitative MCE as a non-invasive test for detection of CAD. Standardizing MCE quantification analysis and adherence to reporting standards for diagnostic tests could enhance the quality of evidence in this field.
Resumo:
BACKGROUND: The most common laparoscopic complications are associated with trocar insertion. The purpose of this study was to develop an objective method of evaluating the safety profile of various access devices used in laparoscopic surgery. STUDY DESIGN: In 20 swine, 6 bladed and 2 needle access devices were evaluated. A force profile was determined by measuring the force required to drive the trocar or needle through the fascia and into the peritoneum, at 0 and 10 mmHg. The amount Of tissue deformation, the length of blade exposed, and the duration of exposure were measured using a high-speed digital imaging system. RESULTS: The needle system without the sheath required the least driving force and had the most favorable force profile. In contrast, the bladed, nonretractable trocar system required a higher driving force and a rapid loss of resistance. Insertion under a pneumoperitoneum did not significantly alter the force profile of the various access devices except for the amount of tissue deformation. With the bladed system, the blade itself was exposed for an average of 0.5 to 1.0 seconds for a distance of 4.5 to 5.0 cm. In comparison, the needle system was exposed for 0.2 seconds for a distance of 1.8 cm. CONCLUSIONS: We developed a reproducible method of measuring the forces required to place the access systems, their pattern of resistance loss, and the characteristics of the blade exposure. These parameters may provide an adjunctive and objective measurement of safety, allowing for more direct comparison between various trocar designs. (J Am Coll Surg 2009;209:222-232. (C) 2009 by the American College of Surgeons)
Resumo:
Background and objective The influence of ventilatory settings on static and functional haemodynamic parameters during mechanical ventilation is not completely known. The purpose of this study was to evaluate the effect of positive end-expiratory pressure, tidal volume and inspiratory to expiratory time ratio variations on haemodynamic parameters during haemorrhage and after transfusion of shed blood. Methods Ten anaesthetized pigs were instrumented and mechanically ventilated with a tidal volume of 8 ml kg(-1), a positive end-expiratory pressure of 5 cmH(2)O and an inspiratory to expiratory ratio of 1 : 2. Then, they were submitted in a random order to different ventilatory settings (tidal volume 16 ml kg(-1), positive end-expiratory pressure 15 cmH(2)O or inspiratory to expiratory time ratio 2: 1). Functional and static haemodynamic parameters (central venous pressure, pulmonary artery occlusion pressure, right ventricular end-diastolic volume and pulse pressure variation) were evaluated at baseline, during hypovolaemia (withdrawal of 20% of estimated blood volume) and after an infusion of withdrawn blood (posttransfusion). Results During baseline, a positive end-expiratory pressure of 15cmH(2)O significantly increased pulmonary artery occlusion pressure from 14.6 +/- 1.6 mmHg to 17.4 +/- 1.7 mmHg (P<0.001) and pulse pressure variation from 15.8 +/- 8.5% to 25.3 +/- 9.5% (P<0.001). High tidal volume increased pulse pressure variation from 15.8 8.5% to 31.6 +/- 10.4% (P<0.001), and an inspiratory to expiratory time ratio of 2: 1 significantly increased only central venous pressure. During hypovolaemia, high positive end-expiratory pressure influenced all studied variables, and high tidal volume strongly increased pulse pressure variation (40.5 +/- 12.4% pre vs. 84.2 +/- 19.1 % post, P<0.001). The inversion of the inspiratory to expiratory time ratio only slightly increased filling pressures during hypovolaemia, without without affecting pulse pressure variation or right ventricle end-diastolic volume. Conclusion We concluded that pulse pressure variation measurement is influenced by cyclic variations in intrathoracic pressure, such as those caused by augmentations in tidal volume. The increase in mean airway pressure caused by positive end-expiratory pressure affects cardiac filling pressures and also pulse pressure variation, although to a lesser extent. Inversion of the inspiratory to expiratory time ratio does not induce significant changes in static and functional haemodynamic parameters. Eur J Anaesthesiol 26:66-72 (c) 2009 European Society of Anaesthesiology.
Resumo:
Background Facial motor evoked potential (FMEP) amplitude ratio reduction at the end of the surgery has been identified as a good predictor for postoperative facial nerve outcome. We sought to investigate variations in FMEP amplitude and waveform morphology during vestibular schwannoma (VS) resection and to correlate these measures with postoperative facial function immediately after surgery and at the last follow-up. Methods Intraoperative orbicularis oculi and oris muscles FMEP data from 35 patients undergoing surgery for VS resection were collected, then analysed by surgical stage: initial, dural opening, tumour dissection (TuDis), tumour resection (TuRes) and final. Findings Immediately after surgery, postoperative facial function correlated significantly with the FMEP amplitude ratio during TuDis, TuRes and final stages in both the orbicularis oculi (p = 0.003, 0.055 and 0.028, respectively) and oris muscles (p = 0.002, 0.104 and 0.014, respectively). At the last follow-up, however, facial function correlated significantly with the FMEP amplitude ratio only during the TuDis (p = 0.005) and final (p = 0.102) stages for the orbicularis oris muscle. At both time points, postoperative facial paresis correlated significantly with FMEP waveform deterioration in orbicularis oculi during the final stage (immediate, p = 0.023; follow-up, p = 0.116) and in orbicularis oris during the TuDis, TuRes and final stages (immediate, p = 0.071, 0.000 and 0.001, respectively; follow-up, p = 0.015, 0.001 and 0.01, respectively). Conclusions FMEP amplitude ratio and waveform morphology during VS resection seem to represent independent quantitative parameters that can be used to predict postoperative facial function. Event-to-baseline FMEP monitoring is quite useful to dictate when intraoperative changes in surgical strategy are warranted to reduce the chances of facial nerve injury.
Resumo:
In order to qualify and quantify nerve fiber lesion following an acute crush injury, a morphologic and morphometric study was carried out in 25 Wistar rats divided into live groups of five animals each according to the crushing load applied, i.e., 500,1000, 5000, 10 000, and 15 000 g. The injury was produced under general anesthesia on a 5 mm-long intermediate segment of the right sciatic nerve for 10 min using a dead-weight machine. The animals were killed with an excessive dose of anesthetics 72 h later and submitted to perfusion with a fixing solution through the abdominal aorta immediately after death. Both the right and left sciatic nerves were removed and prepared for histologic and morphometric examinations: 5 mu m-thick sections stained with 1% Toluidine blue were examined under a light microscope equipped with a video camera linked to a computer loaded with a graphic program (KS 400). The morphometric studies included measuring total number of fibers, fiber density, fiber diameter, myelin fiber area, axon diameter, axon area and G ratio. The results showed that damage to the nerve fibers began to appear as early as with the 500g load and was similar in all groups despite the load applied, increasing with the 10000 and 15000g loads, although the external supporting tissues and small diameter fibers were preserved. The predominant type of lesion produced was axonotmesis. (c) 2008 Elsevier B.V. All rights reserved.