915 resultados para standard error


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Visual search and oculomotor behaviour are believed to be very relevant for athlete performance, especially for sports requiring refined visuo-motor coordination skills. Modern coaches believe that a correct visuo-motor strategy may be part of advanced training programs. In this thesis two experiments are reported in which gaze behaviour of expert and novice athletes were investigated while they were doing a real sport specific task. The experiments concern two different sports: judo and soccer. In each experiment, number of fixations, fixation locations and mean fixation duration (ms) were considered. An observational analysis was done at the end of the paper to see perceptual differences between near and far space. Purpose: The aim of the judo study was to delineate differences in gaze behaviour characteristics between a population of athletes and one of non athletes. Aspects specifically investigated were: search rate, search order and viewing time across different conditions in a real-world task. The second study was aimed at identifying gaze behaviour in varsity soccer goalkeepers while facing a penalty kick executed with instep and inside foot. Then an attempt has been done to compare the gaze strategies of expert judoka and soccer goalkeepers in order to delineate possible differences related to the different conditions of reacting to events occurring in near (peripersonal) or far (extrapersonal) space. Judo Methods: A sample of 9 judoka (black belt) and 11 near judoka (white belt) were studied. Eye movements were recorded at 500Hz using a video based eye tracker (EyeLink II). Each subject participated in 40 sessions for about 40 minutes. Gaze behaviour was considered as average number of locations fixated per trial, the average number of fixations per trial, and mean fixation duration. Soccer Methods: Seven (n = 7) intermediate level male volunteered for the experiment. The kickers and goalkeepers, had at least varsity level soccer experience. The vision-in-action (VIA) system (Vickers 1996; Vickers 2007) was used to collect the coupled gaze and motor behaviours of the goalkeepers. This system integrated input from a mobile eye tracking system (Applied Sciences Laboratories) with an external video of the goalkeeper’s saving actions. The goalkeepers took 30 penalty kicks on a synthetic pitch in accordance with FIFA (2008) laws. Judo Results: Results indicate that experts group differed significantly from near expert for fixations duration, and number of fixations per trial. The expert judokas used a less exhaustive search strategy involving fewer fixations of longer duration than their novice counterparts and focused on central regions of the body. The results showed that in defence and attack situation expert group did a greater number of transitions with respect to their novice counterpart. Soccer Results: We found significant main effect for the number of locations fixated across outcome (goal/save) but not for foot contact (instep/inside). Participants spent more time fixating the areas in instep than inside kick and in goal than in save situation. Mean and standard error in search strategy as a result of foot contact and outcome indicate that the most gaze behaviour start and finish on ball interest areas. Conclusions: Expert goalkeepers tend to spend more time in inside-save than instep-save penalty, differences that was opposite in scored penalty kick. Judo results show that differences in visual behaviour related to the level of expertise appear mainly when the test presentation is continuous, last for a relatively long period of time and present a high level of uncertainty with regard to the chronology and the nature of events. Expert judoist performers “anchor” the fovea on central regions of the scene (lapel and face) while using peripheral vision to monitor opponents’ limb movements. The differences between judo and soccer gaze strategies are discussed on the light of physiological and neuropsychological differences between near and far space perception.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In this work we develop and analyze an adaptive numerical scheme for simulating a class of macroscopic semiconductor models. At first the numerical modelling of semiconductors is reviewed in order to classify the Energy-Transport models for semiconductors that are later simulated in 2D. In this class of models the flow of charged particles, that are negatively charged electrons and so-called holes, which are quasi-particles of positive charge, as well as their energy distributions are described by a coupled system of nonlinear partial differential equations. A considerable difficulty in simulating these convection-dominated equations is posed by the nonlinear coupling as well as due to the fact that the local phenomena such as "hot electron effects" are only partially assessable through the given data. The primary variables that are used in the simulations are the particle density and the particle energy density. The user of these simulations is mostly interested in the current flow through parts of the domain boundary - the contacts. The numerical method considered here utilizes mixed finite-elements as trial functions for the discrete solution. The continuous discretization of the normal fluxes is the most important property of this discretization from the users perspective. It will be proven that under certain assumptions on the triangulation the particle density remains positive in the iterative solution algorithm. Connected to this result an a priori error estimate for the discrete solution of linear convection-diffusion equations is derived. The local charge transport phenomena will be resolved by an adaptive algorithm, which is based on a posteriori error estimators. At that stage a comparison of different estimations is performed. Additionally a method to effectively estimate the error in local quantities derived from the solution, so-called "functional outputs", is developed by transferring the dual weighted residual method to mixed finite elements. For a model problem we present how this method can deliver promising results even when standard error estimator fail completely to reduce the error in an iterative mesh refinement process.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Die Verifikation numerischer Modelle ist für die Verbesserung der Quantitativen Niederschlagsvorhersage (QNV) unverzichtbar. Ziel der vorliegenden Arbeit ist die Entwicklung von neuen Methoden zur Verifikation der Niederschlagsvorhersagen aus dem regionalen Modell der MeteoSchweiz (COSMO-aLMo) und des Globalmodells des Europäischen Zentrums für Mittelfristvorhersage (engl.: ECMWF). Zu diesem Zweck wurde ein neuartiger Beobachtungsdatensatz für Deutschland mit stündlicher Auflösung erzeugt und angewandt. Für die Bewertung der Modellvorhersagen wurde das neue Qualitätsmaß „SAL“ entwickelt. Der neuartige, zeitlich und räumlich hoch-aufgelöste Beobachtungsdatensatz für Deutschland wird mit der während MAP (engl.: Mesoscale Alpine Program) entwickelten Disaggregierungsmethode erstellt. Die Idee dabei ist, die zeitlich hohe Auflösung der Radardaten (stündlich) mit der Genauigkeit der Niederschlagsmenge aus Stationsmessungen (im Rahmen der Messfehler) zu kombinieren. Dieser disaggregierte Datensatz bietet neue Möglichkeiten für die quantitative Verifikation der Niederschlagsvorhersage. Erstmalig wurde eine flächendeckende Analyse des Tagesgangs des Niederschlags durchgeführt. Dabei zeigte sich, dass im Winter kein Tagesgang existiert und dies vom COSMO-aLMo gut wiedergegeben wird. Im Sommer dagegen findet sich sowohl im disaggregierten Datensatz als auch im COSMO-aLMo ein deutlicher Tagesgang, wobei der maximale Niederschlag im COSMO-aLMo zu früh zwischen 11-14 UTC im Vergleich zu 15-20 UTC in den Beobachtungen einsetzt und deutlich um das 1.5-fache überschätzt wird. Ein neues Qualitätsmaß wurde entwickelt, da herkömmliche, gitterpunkt-basierte Fehlermaße nicht mehr der Modellentwicklung Rechnung tragen. SAL besteht aus drei unabhängigen Komponenten und basiert auf der Identifikation von Niederschlagsobjekten (schwellwertabhängig) innerhalb eines Gebietes (z.B. eines Flusseinzugsgebietes). Berechnet werden Unterschiede der Niederschlagsfelder zwischen Modell und Beobachtungen hinsichtlich Struktur (S), Amplitude (A) und Ort (L) im Gebiet. SAL wurde anhand idealisierter und realer Beispiele ausführlich getestet. SAL erkennt und bestätigt bekannte Modelldefizite wie das Tagesgang-Problem oder die Simulation zu vieler relativ schwacher Niederschlagsereignisse. Es bietet zusätzlichen Einblick in die Charakteristiken der Fehler, z.B. ob es sich mehr um Fehler in der Amplitude, der Verschiebung eines Niederschlagsfeldes oder der Struktur (z.B. stratiform oder kleinskalig konvektiv) handelt. Mit SAL wurden Tages- und Stundensummen des COSMO-aLMo und des ECMWF-Modells verifiziert. SAL zeigt im statistischen Sinne speziell für stärkere (und damit für die Gesellschaft relevante Niederschlagsereignisse) eine im Vergleich zu schwachen Niederschlägen gute Qualität der Vorhersagen des COSMO-aLMo. Im Vergleich der beiden Modelle konnte gezeigt werden, dass im Globalmodell flächigere Niederschläge und damit größere Objekte vorhergesagt werden. Das COSMO-aLMo zeigt deutlich realistischere Niederschlagsstrukturen. Diese Tatsache ist aufgrund der Auflösung der Modelle nicht überraschend, konnte allerdings nicht mit herkömmlichen Fehlermaßen gezeigt werden. Die im Rahmen dieser Arbeit entwickelten Methoden sind sehr nützlich für die Verifikation der QNV zeitlich und räumlich hoch-aufgelöster Modelle. Die Verwendung des disaggregierten Datensatzes aus Beobachtungen sowie SAL als Qualitätsmaß liefern neue Einblicke in die QNV und lassen angemessenere Aussagen über die Qualität von Niederschlagsvorhersagen zu. Zukünftige Anwendungsmöglichkeiten für SAL gibt es hinsichtlich der Verifikation der neuen Generation von numerischen Wettervorhersagemodellen, die den Lebenszyklus hochreichender konvektiver Zellen explizit simulieren.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

PURPOSE: To determine the reproducibility and validity of video screen measurement (VSM) of sagittal plane joint angles during gait. METHODS: 17 children with spastic cerebral palsy walked on a 10m walkway. Videos were recorded and 3d-instrumented gait analysis was performed. Two investigators measured six sagittal joint/segment angles (shank, ankle, knee, hip, pelvis, and trunk) using a custom-made software package. The intra- and interrater reproducibility were expressed by the intraclass correlation coefficient (ICC), standard error of measurements (SEM) and smallest detectable difference (SDD). The agreement between VSM and 3d joint angles was illustrated by Bland-Altman plots and limits of agreement (LoA). RESULTS: Regarding the intrarater reproducibility of VSM, the ICC ranged from 0.99 (shank) to 0.58 (trunk), the SEM from 0.81 degrees (shank) to 5.97 degrees (trunk) and the SDD from 1.80 degrees (shank) to 16.55 degrees (trunk). Regarding the interrater reproducibility, the ICC ranged from 0.99 (shank) to 0.48 (trunk), the SEM from 0.70 degrees (shank) to 6.78 degrees (trunk) and the SDD from 1.95 degrees (shank) to 18.8 degrees (trunk). The LoA between VSM and 3d data ranged from 0.4+/-13.4 degrees (knee extension stance) to 12.0+/-14.6 degrees (ankle dorsiflexion swing). CONCLUSION: When performed by the same observer, VSM mostly allows the detection of relevant changes after an intervention. However, VSM angles differ from 3d-IGA and do not reflect the real sagittal joint position, probably due to the additional movements in the other planes.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

There are clear signs that the agro-pastoralists in the Himalayan and Hindu-Kush mountain ranges will have less cropping opportunities due to reduced possibilities for irrigated agriculture as a result of climate change. The importance of extensive livestock production based on well adapted livestock species may once again increase. This calls for a better documentation and understanding of the adaptation capabilities of indigenous breeds considering a changing environment. The current study investigates the adaptive traits of the Azikheli buffalo to mountain environments through calculating mean, standard error and percentages for different variables. Results from this study suggest that the brown coat color, the small body size and the high fertility are adaptive traits of the Azikheli buffalo that may well suit harsh mountainous environment conditions with greater climate variability. Local farmers find it hard to sustain the Azikheli buffalo’s key adaptive traits because of a low bull to buffalo ratio, possibility of insemination with semen from imported breeds and a lack of institutional support to conserve the Azikheli breed. The breed is crucial for sustaining custodian communities in these mountains and thus needs to be conserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In addition to particle size and surface chemistry, the shape of particles plays an important role in their wetting and displacement by the surfactant film in the lung. The role of particle shape was the subject of our investigations using a model system consisting of a modified Langmuir-Wilhelmy surface balance. We measured the influence of sharp edges (lines) and other highly curved surfaces, including sharp corners or spikes, of different particles on the spreading of a dipalmitoylphosphatidyl (DPPC) film. The edges of cylindrical sapphire plates (circular curved edges, 1.65 mm radius) were wetted at a surface tension of 10.7 mJ/m2 (standard error (SE) = 0.45, n = 20) compared with that of 13.8 mJ/m2 (SE = 0.20, n = 20) for cubic sapphire plates (straight linear edges, edge length 3 mm) (p < 0.05). The top surfaces of the sapphire plates (cubic and cylindrical) were wetted at 8.4 mJ/m2 (SE = 0.54, n = 20) and 9.1 mJ/m2 (SE = 0.50, n = 20), respectively, but the difference was not significant (p > 0.05). The surfaces of the plates showed significantly higher resistance to spreading compared to that of the edges, as substantially lower surface tensions were required to initiate wetting (p < 0.05). Similar results were found for talc particles, were the edges of macro- and microcrystalline particles were wetted at 7.2 mJ/m2 (SE = 0.52, n = 20) and 8.2 mJ/m2 (SE = 0.30, n = 20) (p > 0.05), respectively, whereas the surfaces were wetted at 3.8 mJ/m2 (SE = 0.89, n = 20) and 5.8 mJ/m2 (SE = 0.52, n = 20) (p < 0.05), respectively. Further experiments with pollen of malvaceae and maize (spiky and fine knobbly surfaces) were wetted at 10.0 mJ/m2 (SE = 0.52, n = 10) and 22.75 mJ/m2 (SE = 0.81, n = 10), respectively (p < 0.05). These results show that resistance to spreading of a DPPC film on various surfaces is dependent on the extent these surfaces are curved. This is seen with cubic sapphire plates which have at their corners a radius of curvature of about 0.75 microm, spiky malvaceae pollen with an even smaller radius on top of their spikes, or talc with various highly curved surfaces. These highly curved surfaces resisted wetting by the DPPC film to a higher degree than more moderately curved surfaces such as those of cylindrical sapphire plates, maize pollens, or polystyrene spheres, which have a surface free energy similar to that of talc but a smooth surface. The macroscopic plane surfaces of the particles demonstrated the greatest resistance to spreading. This was explained by the extremely fine grooves in the nanometer range, as revealed by electron microscopy. In summary, to understand the effects of airborne particles retained on the surfaces of the respiratory tract, and ultimately their pathological potential, not only the particle size and surface chemistry but also the particle shape should be taken in consideration.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

OBJECTIVES: Biologic effects of high homeopathic potencies can be studied in cell cultures using cell lines or primary cells. We hypothesized that primary cells would be more apt to respond to high potencies than cell lines, especially cancer cell lines. We set out to investigate the effects of low doses and high homeopathic potencies of cadmium chloride, respectively, in an intoxication model with human primary lymphocytes compared to a human leukemia cell line (Jurkat). DESIGN: Cells were pretreated with either low concentrations (nM-microM) or high potencies (pool 15-20c) of cadmium for 120 hours, following which they were exposed to a toxic treatment with a range of cadmium concentrations (8-80 microM) during 24 hours. Cell viability was eventually assessed by use of the MTS/PES assay. Controls included a vehicle (NaCl 0.9%) for the low concentrations of cadmium or water 15-20c for cadmium 15-20c. A total of 34 experiments were conducted, 23 with low concentrations and 11 with high potencies of cadmium. Data were analyzed by analysis of variance. RESULTS: Pretreatment with low concentrations or high potencies of cadmium significantly increased cell viability in primary lymphocytes after toxic challenge, compared to control cells (mean effect +/- standard error = 19% +/- 0.9% for low concentrations respectively 8% +/- 0.6% for high potencies of cadmium; p < 0.001 in both cases). The pretreatment effect of low doses was significant also in cancerous lymphocytes (4% +/- 0.5%; p < 0.001), albeit weaker than in normal lymphocytes. However, high homeopathic potencies had no effect on cancerous lymphocytes (1% +/- 1.9%; p = 0.45). CONCLUSIONS: High homeopathic potencies exhibit a biologic effect on cell cultures of normal primary lymphocytes. Cancerous lymphocytes (Jurkat), having lost the ability to respond to regulatory signals, seem to be fairly unresponsive to high homeopathic potencies.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Publication bias and related bias in meta-analysis is often examined by visually checking for asymmetry in funnel plots of treatment effect against its standard error. Formal statistical tests of funnel plot asymmetry have been proposed, but when applied to binary outcome data these can give false-positive rates that are higher than the nominal level in some situations (large treatment effects, or few events per trial, or all trials of similar sizes). We develop a modified linear regression test for funnel plot asymmetry based on the efficient score and its variance, Fisher's information. The performance of this test is compared to the other proposed tests in simulation analyses based on the characteristics of published controlled trials. When there is little or no between-trial heterogeneity, this modified test has a false-positive rate close to the nominal level while maintaining similar power to the original linear regression test ('Egger' test). When the degree of between-trial heterogeneity is large, none of the tests that have been proposed has uniformly good properties.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

OBJECTIVE: To investigate whether orally administered misoprostol during the third stage of labor is efficient in reducing postpartum blood loss. METHODS: In a double-masked trial, during vaginal delivery women were randomly assigned to receive a single oral dose of misoprostol (600 microg) or placebo in third stage of labor, immediately after cord clamping. The third stage of labor was managed routinely by early cord clamping and controlled cord traction; oxytocin was administered only if blood loss seemed more than usual. Blood loss was estimated by the delivering physician and differences in hematocrit were measured before and after delivery. RESULTS: Mean (+/- standard error of the mean) estimated blood loss (345 +/- 19.5 mL versus 417 +/- 25.9 mL, P = .031) and hematocrit difference (4.5 +/- 0.9% versus 7.9 +/- 1.2%, P = .014) were significantly lower in women who received misoprostol than those who received placebo. Fewer women in the misoprostol group had postpartum hemorrhage (blood loss of at least 500 mL), but that difference was not statistically significant (7% versus 15%, P = .43). Additional oxytocin before or after placental separation was used less often in the misoprostol group (16% versus 38%, P = .047). There were no differences in the length of third stage of labor (8 +/- 0.9 minutes versus 9 +/- 1 minutes, P = .947). There were no differences in pain during third stage of labor, postpartum fever, or diarrhea, but shivering was more frequent in the misoprostol group. CONCLUSION: Oral misoprostol administered in the third stage of labor reduced postpartum blood loss and might be effective in reducing incidence of postpartum hemorrhage.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In normal dogs and dogs with subaortic stenosis, it is known that the subcostal transducer site provides higher left ventricular ejection velocities than does the left apical site. We hypothesized that aortic flow velocities could also be obtained from the right parasternal long-axis view, optimized for the placement of the Doppler cursor as parallel as possible into the aortic root. In 15 healthy dogs and 13 healthy cats, high-pulsed repetition frequency Doppler flow velocity measurements in the proximal aorta were performed using two-dimensional echocardiographic guidance. The mean [ +/- standard error of the mean (SEM)] peak aortic flow velocities in healthy dogs were as follows: subcostal site 1.46 +/- 0.05 m/s; apical site 1.12 +/- 0.06 m/s; right parasternal long-axis site 1.09 +/- 0.05 m/s. In healthy cats, the following peak aortic flow velocities were observed: apical site 0.87 +/- 0.03m/s; right parasternal long-axis site 0.87 +/- 0.03 m/s. Aortic flow velocities obtained from the subcostal site were significantly higher in healthy dogs than those obtained from the left apical and right parasternal long-axis site (P< 0.001). There was no statistical difference between the peak aortic flow velocities obtained from right parasternal long-axis and left apical transducer position in all groups. We conclude therefore that right parasternal long-axis and left apical-derived aortic flow velocities are similar and may be used interchangeably in healthy dogs and cats.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Nitrous oxide fluxes were measured at the Lägeren CarboEurope IP flux site over the multi-species mixed forest dominated by European beech and Norway spruce. Measurements were carried out during a four-week period in October–November 2005 during leaf senescence. Fluxes were measured with a standard ultrasonic anemometer in combination with a quantum cascade laser absorption spectrometer that measured N2O, CO2, and H2O mixing ratios simultaneously at 5 Hz time resolution. To distinguish insignificant fluxes from significant ones it is proposed to use a new approach based on the significance of the correlation coefficient between vertical wind speed and mixing ratio fluctuations. This procedure eliminated roughly 56% of our half-hourly fluxes. Based on the remaining, quality checked N2O fluxes we quantified the mean efflux at 0.8±0.4 μmol m−2 h−1 (mean ± standard error). Most of the contribution to the N2O flux occurred during a 6.5-h period starting 4.5 h before each precipitation event. No relation with precipitation amount could be found. Visibility data representing fog density and duration at the site indicate that wetting of the canopy may have as strong an effect on N2O effluxes as does below-ground microbial activity. It is speculated that above-ground N2O production from the senescing leaves at high moisture (fog, drizzle, onset of precipitation event) may be responsible for part of the measured flux.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Magnetic resonance imaging of inhaled fluorinated inert gases ((19)F-MRI) such as sulfur hexafluoride (SF(6)) allows for analysis of ventilated air spaces. In this study, the possibility of using this technique to image lung function was assessed. For this, (19)F-MRI of inhaled SF(6) was compared with respiratory gas analysis, which is a global but reliable measure of alveolar gas fraction. Five anesthetized pigs underwent multiple-breath wash-in procedures with a gas mixture of 70% SF(6) and 30% oxygen. Two-dimensional (19)F-MRI and end-expiratory gas fraction analysis were performed after 4 to 24 inhaled breaths. Signal intensity of (19)F-MRI and end-expiratory SF(6) fraction were evaluated with respect to linear correlation and reproducibility. Time constants were estimated by both MRI and respiratory gas analysis data and compared for agreement. A good linear correlation between signal intensity and end-expiratory gas fraction was found (correlation coefficient 0.99+/-0.01). The data were reproducible (standard error of signal intensity 8% vs. that of gas fraction 5%) and the comparison of time constants yielded a sufficient agreement. According to the good linear correlation and the acceptable reproducibility, we suggest the (19)F-MRI to be a valuable tool for quantification of intrapulmonary SF(6) and hence lung function.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

AIMS: To assess the impact of different implant systems on the clinical conditions and the microbiota at implants, and whether the presence of bacteria at tooth sites was predictive of the presence at implant sites. MATERIALS AND METHODS: Subjects with either AstraTech or Brånemark in function for 7 years were enrolled. Sub-gingival bacterial samples at tooth and implant sites were collected with sterile endodontic paper points, and analyzed by the checkerboard DNA-DNA hybridization method (40 species). RESULTS: Fifty-four subjects, 27 supplied with AstraTech (n=132 implants) and 27 with Brånemark (n=102) implants, were studied. Test tooth sites had significantly less evidence of bleeding on probing (P<0.001) and presence of plaque (P<0.001) than implant test sites. Implant sites presented with deeper probing pocket depth than tooth sites (mean difference: 1.1 mm, standard error of differences: 0.08, 95% confidence intervals (CI): 0.9-1.3, P<0.001). Tannerella forsythia (P<0.05), Capnocytophaga sputigena (P<0.05), Actinomyces israelii (P<0.05) and Lactobacillus acidophilus (P<0.05) were found at higher levels at tooth surfaces. No differences in bacterial load for any species were found between the two implant systems. The odds of being present/absent at tooth and implants sites were only significant for Staphylococcus aureus [odds ratio (OR): 5.2 : 1, 95% CI: 1.4-18.9, P<0.01]. CONCLUSIONS: After 7 years in function, implants presented with deeper probing depths than teeth. S. aureus was commonly present at both teeth and implants sites. S. aureus at tooth sites was predictive of also being present at implant sites.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Physical fitness can be evaluated in competitive and school sports with different field tests under different conditions and goals. To produce valid results, a field test must be practical and reach high standards of test criteria (objectivity, reliability, validity). The purpose of this study was to investigate the test criteria and the practicability of a group of field tests called «SUISSE Sport Test Konzept Basis Feldtestbatterie». For 20-m sprint, ventral trunk muscle test, standing long jump, 2-kg medicine ball shot, obstacle course and cooper-test, test quality and practicability were evaluated. 221 children and adolescents from competitive sports and different school levels took part in the study. According to school level, they were divided into 3 groups (P: 7–11.5 y, S1: 11.6–15.5 y, S2: 15.6–21.8 y). Objectivity was tested for time or distance measurement in all tests as well as for error rating in obstacle test. For reliability measurement, 162 subjects performed the field tests twice within a few weeks. For validity results of standing long jump were compared with counter movement jump performance on a force plate. Correlation analysis was performed and level of significance was set for p < 0.05. For accuracy standard error was calculated. All tests achieved sufficient to excellent objectiv - ity with correlation-coefficient (r) lying between 0.85 and 0.99. Reliability was very good (r = 0.84–0.97). In cooper- and trunk test, reliability was higher for athletes than for pupils (trunk test: r = 0.95 vs. r = 0.62, cooper-test: r = 0.90 vs. r = 0.78). In those tests the reliability decreases with increasing age (cooper-test: P: r = 0.84, S1: r = 0.69, S2: r = 0.52; trunk-test: P: r = 0.69, S1: r = 0.71; S2: r = 0.39). Validity for standing long jump was good (r = 0.75–0.86). The standard error of the mean was between 4–8%, with the exception for cooper-test (athletes: 6%, pupils: 11%) and trunk test (athletes: 14%, pupils: 46%). The results show that the evaluated group of field tests is a practicable, objective and reliable tool to determine physical skills in young athletes as well as in a scholar setting over a broad age range. Most of the tests achieved the test criteria with the grades good to excellent. The lower coefficient of reliability for cooper- and trunk test by the pupils could be explained by motivational problems in this setting. For up to 20 subjects, a tester can accomplish the tests within 3 h. Finally, age-dependent grades were elaborated

Relevância:

60.00% 60.00%

Publicador:

Resumo:

OBJECTIVE: To assess whether stress further increases hypercoagulation in older individuals. We investigated whether acute stress-induced changes in coagulation parameters differ with age. It is known that hypercoagulation occurs in response to acute stress and that a shift in hemostasis toward a hypercoagulability state occurs with age. However, it is not yet known whether acute stress further increases hypercoagulation in older individuals, and thus may increase their risk for cardiovascular disease (CVD). METHODS: A total of 63 medication-free nonsmoking men, aged between 20 and 65 years (mean +/- standard error of the mean = 36.7 +/- 1.7 years), underwent an acute standardized psychosocial stress task combining public speaking and mental arithmetic in front of an audience. We measured plasma clotting factor VII activity (FVII:C), fibrinogen, and D-dimer at rest, immediately, and 20 minutes after stress. RESULTS: Increased age predicted greater increases in fibrinogen (beta = 0.26, p = 0.041; DeltaR(2) = 0.05), FVII:C (beta = 0.40, p = .006; DeltaR(2) = 0.11), and D-dimer (beta = 0.51, p < .001; DeltaR(2) = 0.18) from rest to 20 minutes after stress independent of body mass index and mean arterial blood pressure. General linear models revealed significant effects of age and stress on fibrinogen, FVII:C, and D-dimer (main effects: p < .04), and greater D-dimer stress reactivity with older age (interaction age-by-stress: F(1.5/90.4) = 4.36, p = .024; f = 0.33). CONCLUSIONS: Our results suggest that acute stress might increase vulnerability in the elderly for hypercoagulability and subsequent hemostasis-associated diseases like CVD.