986 resultados para root canal obturation


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Aim: A retrospective clinical audit was carried out on records of endodontic treatment performed by dental undergraduates. The audit was performed to evaluate the technical quality of root canal fillings performed by dental undergraduates and determine the associated factors. Methods: 140 records of patients who had received root canal treatment by dental undergraduates were evaluated through periapical radiographs by two examiners (κ =0.74). The root canal fillings had their quality evaluated according to extent, condensation and presence of procedural mishap. Possible factors associated with technical quality such as tooth type, canal curvature, student level and quality of record keeping were evaluated. Data were statistically analyzed using chi-square test (p<0.05). Results: Among the 140 root-filled teeth, acceptable extent, condensation and no-mishap were observed in 72.1%, 66.4% and 77.9% cases respectively. Overall, the technical quality of 68 (48.6%) root-filled teeth was considered acceptable. Overall, non-acceptable root canal fillings were significantly more likely to be observed in molars (69.2%), moderately and severely curved canals (71.4%) and junior students (61.5%). There was no association between acceptable root canal fillings and quality of record keeping. Conclusions: The technical quality of root canal fillings was acceptable in 48.6% cases and it was associated with tooth type, degree of canal curvature and student seniority.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Aim: To analyze the root canal organic tissue dissolution capacity promoted by irrigating solutions, with or without the use of different agitation techniques. Methods: Bovine pulp tissue fragments were initially weighed. The following irrigating solutions were tested: 2.5% sodium hypochlorite, 2% chlorhexidine digluconate solution, and distilled water. The irrigating protocols were: immersion, mechanical agitation with endodontic files, and ultrasonic or sonic systems (Endoactivactor® and Easy Clean®). At the end of the protocols, the pulps were weighed to determine their final weight. For comparison, the average percentage of tissue dissolution in relation to the groups was analyzed using the Kruskal-Wallis nonparametric test complemented by multiple comparisons test. The significance level was set at 5%. Results: Among the irrigation solutions, 2.5% sodium hypochlorite showed a higher dissolving power than 2% chlorhexidine digluconate and distilled water. Furthermore, ultrasonic and sonic systems were more effective irrigating protocols than immersion and mechanical agitation with endodontic files. Conclusions: The combination of sodium hypochlorite with an agitation system promotes a greater degree of tissue degradation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

O objetivo desse trabalho foi avaliar a biocompatibilidade de um material a base de guta-percha autoadesiva (Bio-Gutta) em tecido subcutâneo de camundongos. A guta-percha convencional foi utilizada como referência para comparação. Para isso, foram utilizados 30 camundongos, os quais foram distribuídos aleatoriamente em dois grupos (Bio-Gutta e guta-percha convencional). Os materiais avaliados foram implantados na região dorsal dos camundongos. Após 7, 21 e 63 dias, os animais foram sacrificados e 5 amostras por grupo por tempo experimental foram obtidas. As amostras histológicas foram seccionadas em 5 m de espessura e coradas convencionalmente com hematoxilina e eosina. Um escore de I-IV foi utilizado para graduar a reação inflamatória. O teste U de Mann-Whitney com correção de Bonferroni foi utilizado para análise estatística (p < 0,05). Os resultados mostraram que, após 7 dias, a Bio-Gutta induziu uma reação tecidual de leve a moderada (II) e a guta-percha convencional apresentou uma resposta inflamatória de moderada a intensa (III). Após 21 dias, a Bio-Gutta induziu uma leve reação tecidual (I), enquanto que a guta-percha convencional ainda apresentava uma resposta inflamatória moderada (III). Uma reação tecidual de leve a ausente (I) foi observada na Bio-Gutta após 63 dias, ao passo que na guta-percha convencional observou-se uma resposta inflamatória de leve a moderada (II). Houve diferença significativa na mediana do grau de inflamação entre os grupos em cada tempo experimental (p = 0,005, aos 7 dias; p = 0,011, aos 21 dias; e p = 0,003, aos 63 dias). Concluiu-se então que a Bio-Gutta foi mais biocompatível que a guta-percha convencional em tecido subcutâneo de camundongos apresentando uma boa resposta tecidual.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: To evaluate 2 techniques for the treatment of human primary molars with necrotic Pulp and bifurcation bone loss by means of radiographic examination for 48 months. Method and Materials: Fifty-one mandibular primary molars were evaluated in children ranging from 4.5 to 6.5 years of age. The teeth with necrotic pulp and bifurcation bone loss were diagnosed by radiographic examination. The teeth were divided into 2 groups: group 1 (28 teeth)-pulpotomy technique using formocresol as a temporary dressing between sessions and coronal chamber obturation with zinc oxide-eugenol cement; and group 2 (23 teeth)-pulpectomy technique with calcium hydroxide paste as a temporary dressing between sessions and root canal obturation with a dense Calcium hydroxide paste. Standardized radiographs were taken immediately after the fillings were completed and after 12, 24, 36, and 48 months. The radiographs were digitized and analyzed with software that outlined and measured the bifurcation radiolucency. Results: Bifurcation radiolucency reduced significantly or repaired completely for both treatnients in the first 12 months. Minor radiographic reduction of the lesion was observed from 12 to 24 months, and no significant reduction of the remaining radioulcent area was observed from 24 to 48 months after treatment. Conclusion: The 2 endodontic techniques evaluated showed similar results. The main effect of treatment on the lesion repair was obtained in the first year after treatment.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives: To compare the fracture resistance of bovine teeth after intracoronal bleaching with sodium percarbonate (SPC) or sodium perborate (SP) mixed with water or 20% hydrogen peroxide (HP). Materials and methods: Fifty extracted bovine teeth were divided into four experimental groups (G1G4) and one control (n = 10) after endodontic treatment. Following root canal obturation, a glass ionomer barrier was placed at the cementoenamel junction. After that, the pulp chambers were filled with: G1 SP with water; G2 SP with 20% HP; G3 SPC with water; and G4 SPC with 20% HP. No bleaching agent was used in the control group. Coronal access cavities were sealed with glass ionomer and specimens were immersed in artificial saliva. The bleaching agents were replaced after 7 days, and teeth were kept in artificial saliva for an additional 7 days, after which the pastes were removed and the coronal access cavities were restored with glass ionomer. Crowns were subjected to compressive load at a cross head speed of 0.5 mm min-1 applied at 135 degrees to the long axis of the root by an EMIC DL2000 testing machine, until coronal fracture. Data were statistically analysed by anova and Tukey test. Results: No differences in fracture resistance were observed between the experimental groups (P > 0.05). However, all experimental groups presented lower fracture resistance than the control group (P < 0.05). Conclusion: SPC and SP led to equal reduction on fracture resistance of dental crowns, regardless of being mixed with water or 20% HP.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: The aim of this in vitro study was to evaluate the bond strength of different root canal sealers to dentin. Material and Methods: Forty extracted single-rooted human teeth were examined and the coronal and middle thirds of the canals were prepared with a 1.50 mm post drill (FibreKor Post System, Pentron). The teeth were allocated in two experimental groups, irrigated with 2.5% NaOCl+17% EDTA or saline solution (control group) and instrumented using Race rotary files (FKG) to a size #40 at the working length. Then, the groups were divided into four subgroups and filled with Epiphany sealer (Group 1), EndoREZ (Group 2), AH26 (Group 3) and Grossman's Sealer (Group 4). After 2 weeks of storage in 100% humidity at 37 degrees C, all teeth were sectioned transversally into 2-mm-thick discs. Push-out tests were performed at a cross-head speed of 1 mm/min using a universal testing machine. The maximum load at failure was recorded and expressed in MPa. Results: Means (+/- SD) in root canals irrigated with 2.5% NaOCl and 17% EDTA were: G1 (21.6 +/- 6.0), G2 (15.2 +/- 3.7), G3 (14.6 +/- 4.5) and G4 (11.7 +/- 4.1). Two-way ANOVA and Tukey's test showed the highest bond strength for the Epiphany's group (p < 0.01) when compared to the other tested sealers. Saline solution decreased the values of bond-strength (p < 0.05) for all sealers. Conclusion: Epiphany sealer presented higher bond strength values to dentin in both irrigating protocols, and the use of 2.5% NaOCl and 17% EDTA increased the bond strength values for all sealers.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction: The aim of this study was to evaluate the ability of Resilon (Resilon Research, LLC, North Branford, CT) and 2 types of gutta-percha to fill simulated lateral canals when using the Obtura II system (Model 823-700; Obtura Spartan, Fenton, MO). Methods: Forty-five human single-rooted teeth were selected and subjected to root canal preparation. After that, simulated lateral canals were made at 2, 5, and 8 mm from the working length (WL). The specimens were divided into 3 groups (n = 15) according to the filling material used: Obtura Flow 150 gutta-percha (Obtura flow), Odous Endo Flow gutta-percha (Odous; Odous de Deus Ind e Corn. Ltda Belo Horizonte, MG, Brazil), and Resilon pellets (Resilon). Root canals were filled using the Obtura II system with the tip inserted to 3 mm from the WL. No sealer was used for root canal obturation. Specimens were subjected to a tooth decalcification and clearing method, and filling of the lateral canals was analyzed by digital radiography and photographs. The measurement of lateral canal filling was done using Image Tool software (UTHSCSA Image Tool for Windows version 3.0, San Antonio, TX). Data were statistically analyzed with the Kruskal-Wallis test at 5% significance. Results: All materials showed an ability to penetrate into the simulated lateral canals, with a minimum percentage of 73% in all thirds of the root canal. Conclusions: It was concluded that gutta-percha and Resilon are solid core materials with a lateral canal filling ability when used with the Obtura II system. (J Endod 2012;38:676-679)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Aim To analyse the thermoplasticity of several endodontic filling materials using the Obtura II System at different temperature settings.Methodology The following materials based on gutta-percha: Regular Obtura (OBT), Obtura Flow 150 (OBT F), Endo Flow (EDF), Odous (ODO) and the synthetic thermoplastic polymer material Resilon (RE) were heated using the Obtura II System at three temperature settings (140, 170 and 200 degrees C). Samples of the heated materials were placed on the sensor of a digital thermometer (THR-140; Instrutherm, São Paulo, Brazil) to determine their real temperature (RT) when the system was set at 140 degrees C (from 64.5 to 69 degrees C), 170 degrees C (from 73.8 to 77.5 degrees C) and 200 degrees C (from 83.6 degrees C for EDF and 100 degrees C for RE). Specimens (n = 30) were made by placing samples of each material in metallic ring moulds and compressing them between two glass slabs. After 24 h, specimens (n = 10) were heated at the different settings (RT) and submitted to compression under a 5-kg load. Plasticization was assessed by calculating the differences between the post-compression and initial diameters of each specimen. Data were submitted to ANOVA and Tukey's test at 5% significance.Results At 140 degrees C, Obtura Flow presented the highest thermoplasticity values and Regular Obtura, the lowest. At 170 degrees C, Obtura Flow and Resilon demonstrated greater plasticization. Resilon had the highest mean thermoplasticity values at 200 degrees C.Conclusions Thermoplasticity values were influenced both by the temperature settings on the Obtura II System and by the type of material analysed. Obtura Flow and Resilon had the highest mean thermoplasticity values.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: To assess the setting time (ST), flow (FL), radiopacity (RD), solubility (SB) and dimensional change following setting (DC) of different sealers (AH Plus (R), Polifil, Apexit Plus (R), Sealapex (R), Endomethasone (R) and Endofill (R)) according to American National Standards Institute/American Dental Association (ANSI/ADA) Specification 57. Material and methods: Five samples of each material were used for each test. For ST, cast rings were filled with sealers and tested with a Gillmore needle. For FL, the sealer was placed on a glass plate. After 180 s, another plate with 20 g and a load of 100 g were applied on the material, and the diameters of the discs formed were measured. In RD, circular molds were filled with the sealers, radiographed and analyzed using Digora software. For SB, circular molds were filled with the sealers, a nylon thread was placed inside the material and another glass plate was positioned on the set, pressed and stored at 37 degrees C. Samples were weighed, placed in water, dried and reweighed. The water used for SB was analyzed by atomic absorption spectrometry. For DC, circular molds were filled with the sealers, covered by glass plates and stored at 37 degrees C. Samples were measured and stored in water for 30 days. After this period, they were dryed and measured again. Results: Regarding ST, AH Plus (R), Apexit (R) and Endofil (R) sealers are in accordance with ANSI/ADA standards. Endomethasone's manufacturer did not mention the ST; Polifil is an experimental sealer and Sealapex (R) did not set. Considering RD, SB and DC, all sealers were in accordance with ANSI/ADA. The spectrometric analysis showed that a significant amount of K+ and Zn2(+) ions was released from Apexit Plus (R) and Endofill (R), respectively. Conclusion: Except for DC, all other physicochemical properties of the tested sealers conformed to ANSI/ADA requirements.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Este trabalho avaliou o selamento marginal apical de canais radiculares obturados com os cimentos endodônticos Sealapex, Apexit, Sealer 26 e Ketac Endo. Utilizaram-se 136 raízes, cujos canais radiculares, após o preparo biomecânico, foram obturados pela técnica da condensação lateral ativa com os cimentos em estudo. Metade das amostras, imediatamente após as obturações, foram imersas na solução de azul de metileno a 2% e a outra metade após 6 meses de armazenamento em plasma sangüíneo humano. Observou-se que os cimentos Sealapex e Sealer 26 apresentaram infiltrações médias estatisticamente iguais entre si e menores que as observadas para os demais cimentos (p < 0,05). Amostras imersas no corante imediatamente após a obturação dos canais apresentaram infiltração média menor (0,829 mm) do que aquelas mantidas por 6 meses em plasma sangüíneo humano (1,275 mm). Estas diferenças foram estatisticamente significantes (p < 0,05).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

O objetivo deste trabalho foi analisar a morfologia dos cimentos Sealapex, Apexit, Sealer 26 (cimentos a base de hidróxido de cálcio) e Ketac Endo (cimento de ionômero de vidro), através da microscopia de força atômica, verificando-se as características de suas partículas após a obturação dos canais radiculares e após um período de seis meses de contato com o plasma sanguíneo humano. Utilizaram-se 16 dentes unirradiculares humanos extraídos e incluídos em blocos de resina após o preparo biomecânico. As raízes foram divididas em quatro grupos de quatro raízes cada e os canais radiculares obturados pela técnica de condensação lateral passiva com os cimentos em estudo. Verificou-se que o cimento Apexit foi o que mais sofreu desintegração após seis meses de imersão em plasma sanguíneo humano, seguido pelo Ketac Endo e Sealapex. Dentre todos os cimentos estudados, o Sealer 26 mostrou-se o mais uniforme e com a menor desintegração.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A report of Garre's osteomyelitis of the mandible associated with a fistula is presented. Elimination of pulpal periapical infection through endodontic therapy was shown to be an effective treatment. The total bone healing was observed one year later.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: The aim of this study was to evaluate the thermoplasticity of three commercial brands of gutta-percha (Tanari, Dentsply 0.06, and Roeko), and of the TC system. Materials and Methods: Standardized specimens were fabricated from the materials to be evaluated. Specimens were placed in water at 70°C for 60 seconds. Following that, they were positioned between two glass slabs and each set was compressed by a 5kg weight. Images of the specimens before and after compression were digitized and analyzed by the Image Tool software. The flow capacity of each material was confirmed by the difference between the initial and final areas of each sample. Results: The resulting data were analyzed by ANOVA. The TC system presented the greatest thermoplasticity values (p<0.05). Among the gutta-percha cones, the Roeko brand showed higher thermoplasticity than the others (p<0.05). Conclusion: The gutta-percha from TC system present good thermoplasticity capacity.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purpose of this in vitro study was to evaluate the effect of neodymium:yttrium-aluminum-garnet (Nd:YAG) laser irradiation on intracanal dentin surface by SEM analysis and its interference in the apical seal of filled canals. After endodontic treatment procedures, 34 maxillary human incisors were randomly assigned to 2 groups. In the negative control group (n=17), no additional treatment was performed and teeth were filled with vertically condensed gutta-percha; in the laser-treated group (n=17), the root canals were irradiated with Nd:YAG laser (1.5 W, 100 mJ, 15 Hz) before filling as described for the control group. Two specimens of each group were prepared for SEM analysis to evaluate the presence and extent of morphological changes and removal of debris; the other specimens were immersed in 0.5% methylene blue dye (pH 7.2) for 24 h for evaluation of the linear dye leakage at the apical third. SEM analysis of the laser-treated group showed dentin fusion and resolidification without smear layer or debris. The Student's t-test showed that the laser-treated group had significantly less leakage in apical third than the control group. Within the limitations of this study, it may be concluded that the morphological changes on the apical intraradicular dentin surface caused by Nd:YAG laser resulted in less linear dye apical leakage.