1000 resultados para RADIOLOGIA


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The assessment of patient dose has gained increased attention, still being an issue of concern that arises from the use of digital systems. The development of digital technology offers the possibility for a reduction of radiation dose around 50% without loss in image quality when compared to a conventional screen–film system. Digital systems give an equivalent or superior diagnostic performance and also several other advantages, but the risk of overexposure with no adverse effect on image quality could be present. This chapter refers to the management of patient dose and provides an explanation of dose-related concepts. In this chapter, exposure influence in dose and image representation and the effects of radiation exposure are also discussed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This chapter provides a theoretical background about image quality in diagnostic radiology. Digital image representation and also image quality evaluation methods are here discussed. An overview of methods for quality evaluation of diagnostic imaging procedures is provided. Digital image representation and primary physical image quality parameters are also discussed, including objective image quality measurements and observer performance methods.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Digital radiography detectors—based on different technological solutions—are currently available for clinical applications and widespread in clinical practice. Computed radiography (CR) and digital radiology systems have been available for clinical applications and the trend over the last few years has become digital. Radiology departments have been changing from traditional screen–film technology to digital technology. This chapter is intended to give the reader a practical understanding about the key aspects concerning digital systems, related to the performance of different technologies, image quality, and dose and patient safety/protection. The discussion around an optimization framework for digital systems is provided.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Once in a digital form, a radiographic image may be processed in several ways in order to turn the visualization an act of improved diagnostic value. Practitioners should be aware that, depending on each clinical context, digital image processing techniques are available to help to unveil visual information that is, in fact, carried by the bare digital radiograph and may be otherwise neglected. The range of visual enhancement procedures includes simple techniques that deal with the usual brightness and contrast manipulation up to much more elaborate multi-scale processing that provides customized control over the emphasis given to the relevant finer anatomical details. This chapter is intended to give the reader a practical understanding of image enhancement techniques that might be helpful to improve the visual quality of the digital radiographs and thus to contribute to a more reliable and assertive reporting.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Plain radiography still accounts for the vast majority of imaging studies that are performed at multiple clinical instances. Digital detectors are now prominent in many imaging facilities and they are the main driving force towards filmless environments. There has been a working paradigm shift due to the functional separation of acquisition, visualization, and storage with deep impact in the imaging workflows. Moreover with direct digital detectors images are made available almost immediately. Digital radiology is now completely integrated in Picture Archiving and Communication System (PACS) environments governed by the Digital Imaging and Communications in Medicine (DICOM) standard. In this chapter a brief overview of PACS architectures and components is presented together with a necessarily brief account of the DICOM standard. Special focus is given to the DICOM digital radiology objects and how specific attributes may now be used to improve and increase the metadata repository associated with image data. Regular scrutiny of the metadata repository may serve as a valuable tool for improved, cost-effective, and multidimensional quality control procedures.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Portugal atravessa uma crise económico-financeira. A austeridade económica é prioritária, e a área de saúde não é exceção. Nesta conjuntura justifica-se de todo a realização de análises económicas na saúde. Este estudo é uma análise custo - mínimo ao Projeto de Internalização do RX do Centro Diagnóstico Pneumológico (CDP) do Porto com o objetivo de rentabilizar o equipamento radiológico instalado no CDP do Porto, pretende-se usar a capacidade máxima instalada e permitida pelo equipamento para produção de radiografias a utentes provenientes dos Agrupamentos de Centros de Saúde (ACES) do Porto. O Projeto de Internalização do RX do CDP do Porto é um projeto da Administração Regional de Saúde (ARS) do Norte, que pretende encaminhar os utentes dos ACES do Porto para realização de exames radiográficos no RX do CDP do Porto. Para proceder à análise económica foram identificados os custos e os benefícios relevantes do RX do CDP do Porto e elaboradas 3 estimativas: 1. Realização dos exames radiográficos do CDP do Porto a utentes do CDP do Porto e realização de exames radiográficos a utentes dos ACES do Porto nos gabinetes de radiologia convencionados pela ARSNorte; 2. Projeto de Internalização do RX do CDP do Porto com realização dos exames radiográficos até esgotar a capacidade máxima instalada do equipamento radiológico com recurso a utentes dos ACES do Porto; 3. Realização dos exames radiográficos nos ACES do Porto e dos exames do CDP do Porto nos gabinetes de radiologia convencionados. Os resultados da análise levaram à conclusão que a implementação do Projeto de Internalização do RX do Porto é rentável, ou seja, o projeto permitirá ganhos financeiros para a ARSNorte se for implementado na sua plenitude.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Claustrophobia causes a huge discomfort to those who need to perform Magnetic Resonance examinations mainly due to the physical design of most equipment. This study aimed to maximize the success rate of Magnetic Resonance Imaging (MRI) clinical studies in claustrophobic patients by the identification of facilitative strategies.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

O cancro colo - rectal (CCR) é um problema de saúde mundial, estando associadas elevadas taxas de mortalidade e morbilidade. A maioria de CCR deriva de pólipos adenomatosos.. Um estudo retrospectivo, efectuado no serviço de Radiologia, dos achados imagiológicos típicos e atípicos, entre Janeiro de 2008 e Junho 2010. A Colonoscopia Virtual, apresenta uma sensibilidade elevada na detecção de lesões, com dimensão superior a 10mm, permitindo um diagnóstico precoce, é um exame rápido, pouco invasivo, não há necessidade de sedação e é efectuada em ambulatório.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Mestrado em Radiações Aplicadas às Tecnologias da Saúde. Área de especialização: Imagem Digital.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Mestrado em Radiações Aplicadas às Tecnologias da Saúde. Área de especialização: Imagem Digital com Radiação X.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Mestrado em Radiações Aplicadas às Tecnologias da Saúde. Área de especialização: Proteção contra Radiações.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Mestrado em Radiações Aplicadas às Tecnologias da Saúde. Área de especialização: Imagem Digital com Radiação X.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objetivo: Este estudo visou avaliar a adequação da Ressonância Magnética (RM) na determinação de indicadores de instabilidade femoro-patelar em exames de RM do joelho. Material e métodos: A amostra foi constituída por 200 imagens adquiridas a partir de 50 RM(s) do joelho e sobre as quais incidiram os procedimentos de medida. Apenas 4 pacientes vinham referidos por alterações do aparelho extensor ou da cartilagem rotuliana. Foram calculados os valores do Índice Insall & Salvatti (ISI), ângulo do sulco troclear, ângulo de inclinação da rótula e o deslocamento da rótula por dois observadores em condições de independência. Nos procedimentos de medida utilizaram-se imagens das ponderações WFS T2*TRS e DP SAG. Resultados: Os valores obtidos de ISI em 49 dos casos sugeriram ser normais para a posição da rótula (<1,3cm). Os valores do ângulo de inclinação externa da rótula indicarem haver fatores predisponentes para a displasia troclear em 17 dos 50 casos com ângulos de abertura interna e inclinação (>11º). O ângulo do sulco troclear apresentou-se displásico em 24% da amostra com valores (>150º). Para o deslocamento externo da rótula, verificou-se que em 39% dos casos a distância assumiu valores negativos (deslocamento externo) superiores a -20mm. Conclusões: Pensa-se ser possível, sem custos acrescidos, desenvolver um algoritmo que determine os valores de referência e métodos standardizados aplicáveis ao despiste de instabilidade da rótula, sempre que é solicitado um exame RM do joelho, mesmo que a referenciação clínica admita diferente causa. Os equipamentos de campo aberto ou de configuração cilíndrica podem contribuir como um recurso eficaz no rastreio desta patologia.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Considering that ionizing radiation effects are cumulative and the gonads are particularly sensitive to these effects, and also the clinical importance of pelvic radiographs in children, the excess of radiation exposure to the gonads must be avoided. The purpose of this study is to demonstrate the relevance of the correct use of gonad protection shields and to evaluate their use on the hip radiographs performed in a reference clinical institution, through the retrospective analysis of pelvic radiographic images performed in children. According the image quality assessment, 20 (40%) patients were unprotected and gonads shields were incorrectly placed in 24 (80%) patients.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

RESUMO: Objetivos – Determinar a sensibilidade e especificidade das ponderações Difusão (DWI) e T2 Fluid-Attenuated Inversion Recovery (FLAIR) na avaliação de lesões da substância branca (SB) e verificar em que medida se complementam, por forma a criar um conjunto de boas práticas na RM cranioencefálica de rotina. Metodologia – Recorrendo-se a uma metodologia quantitativa, efetuou-se uma análise retrospetiva da qual foram selecionados 30 pacientes, 10 sem patologia e 20 com patologia (2 com EM, 7 com Leucoencefalopatia, 6 com doença microangiopática e 5 com patologia da substância branca indefinida). Obteve-se uma amostra de 60 imagens, nomeadamente: 30 imagens ponderadas em DWI e 30 em T2 FLAIR. Recorrendo ao programa Viewdex®, três observadores avaliaram um conjunto de imagens segundo sete critérios: visibilidade, deteção, homogeneidade, localização, margens e dimensões da lesão e capacidade de diagnóstico. Com os resultados obtidos recorreu-se ao cálculo de sensibilidade e especificidade pelas Curvas ROC, bem como à análise estatística, nomeadamente, Teste-T, Índice de Concordância Kappa e coeficiente de correlação de Pearson entre as variáveis em estudo. Resultados – Os resultados de sensibilidade e de especificidade obtidos para a ponderação T2 FLAIR foram superiores (0,915 e 0,038, respetivamente) aos da ponderação DWI (0,08 e 0,100, respetivamente). Não se verificaram variâncias populacionais significativas. Obteve-se uma elevada correlação linear entre as variáveis com um valor r situado entre 0,8 e 0,99. Verificou-se também uma variabilidade considerável entre os observadores. Conclusões – Dados os baixos valores de sensibilidade e especificidade obtidos para a DWI, sugere-se que esta deva ser incluída no protocolo de rotina de crânio como auxiliar no diagnóstico diferencial com outras patologias.