976 resultados para Pressure method


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The main target here is to determine the orbit of an artificial satellite, using signals of the GPS constellation and least squares algorithms implemented through sequential Givens rotations as a method of estimation, with the aim of improving the performance of the orbit estimation process and, at the same time, minimizing the computational procedure cost. Geopotential perturbations up to high order and direct solar radiation pressure were taken into account. It was also considered the position of the GPS antenna on the satellite body that, lately, consists of the influence of the satellite attitude motion in the orbit determination process. An application has been done, using real data from the Topex/Poseidon satellite, whose ephemeris is available at Internet. The best accuracy obtained in position was smaller than 5 meters for short period (2 hours) and smaller than 28 meters for long period (24 hours) orbit determination. In both cases, the perturbations mentioned before were taken into consideration and the analysis occurred without selective availability on the signals measurements.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVETo evaluate the correlation between ultrasound-estimated bladder weight (UEBW) in patients with different degrees of bladder outlet obstruction (BOO).METHODSWe evaluated 50 consecutive non-neurogenic male patients with lower urinary tract symptoms (LUTS) referred to urodynamic study (UDS). All patients self-answered the International Prostate Score Symptoms (IPSS) questionnaire. After the UDS, the bladder was filled with 150 mL to determine UEBW.Patients with a bladder capacity under 150 mL, a previous history of prostate surgery or pelvic irradiation, an IPSS score <8, a bladder stone or urinary tract infection were excluded.After a pressure-flow study, the Schafer linear passive urethral resistance relation nomogram was plotted to determine the grade of obstruction: Grades I-II/VI were defined as mild obstruction, Grades III-IV/VI as moderate obstruction, and Grades V-VI/VI as severe obstruction.RESULTSThe UEBW was 51.7 +/- 26.9, 54.1 +/- 30.0 and 54.8 +/- 28.2 in patients with mild, moderate and severe BOO, respectively (P = 0.130). The UEBW allowed us to define four groups: (i) UEBW < 35 g; (ii) 35 g <= UEBW < 50 g; (iii) 50 g <= UEBW < 70 g; and (4) UEBW >= 70 g.We did not find any differences in age, prostate weight, IPSS, PVR, cystometric bladder capacity, presence of detrusor overactive and degree of obstruction in the aforementioned groups.CONCLUSIONDespite the fact that some studies have emphasized the value of UEBW as an efficient non-invasive method for evaluating lower urinary tract obstruction, our study suggests that UEBW does not present any individual correlation with LUTS or objective measurements of BOO.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study investigated the effect of an Argon-based atmospheric pressure plasma (APP) surface treatment operated chairside at atmospheric pressure conditions applied immediately prior to dental implant placement in a canine model. Surfaces investigated comprised: rough titanium surface (Ti) and rough titanium surface + Argon-based APP (Ti-Plasma). Surface energy was characterized by the Owens-Wendt-Rabel-Kaelble method and chemistry by X-ray photoelectron spectroscopy (XPS). Six adult beagles dogs received two plateau-root form implants (n = 1 each surface) in each radii, providing implants that remained 1 and 3 weeks in vivo. Histometric parameters assessed were bone-to-implant contact (BIC) and bone area fraction occupancy (BAFO). Statistical analysis was performed by Kruskall-Wallis (95% level of significance) and Dunn's post-hoc test. The XPS analysis showed peaks of Ti, C, and O for the Ti and Ti- Plasma surfaces. Both surfaces presented carbon primarily as hydrocarbon (C?C, C?H) with lower levels of oxidized carbon forms. The Ti-Plasma presented large increase in the Ti (+11%) and O (+16%) elements for the Ti- Plasma group along with a decrease of 23% in surface-adsorbed C content. At 1 week no difference was found in histometric parameters between groups. At 3 weeks significantly higher BIC (>300%) and mean BAFO (>30%) were observed for Ti-Plasma treated surfaces. From a morphologic standpoint, improved interaction between connective tissue was observed at 1 week, likely leading to more uniform and higher bone formation at 3 weeks for the Ti-Plasma treated implants was observed. (C) 2012 Wiley Periodicals, Inc. J Biomed Mater Res Part A 2012.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The usual design of field-emission displays (FEDs) often results in high vacuum pressure gradients inside the glass plates of the device, and this is the main limitation to the widespread availability of large area FEDs. In this paper, we perform theoretical calculations using the finite element method for determining the pressure distributions in several pumping configurations, including a new FED configuration known as porous FED or pFED. The approach here is capable of clarifying the design issues influencing the final pressure relevant to the field-emission display devices. (C) 2001 Elsevier B.V. B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A simple and easily implemented method is developed to keep the vertical velocity equal to zero at the bottom and top of hydrostatic incompressible numerical models. The pressure is computed at the top by correcting its value given in the previous time step so that the vertical integral of the horizontal divergence is zero at each column. Numerical experiments that exhibit small time variations of pressure at the top are able to simplify the algorithm and save computer time. Numerical simulations illustrate the method effectiveness for a horizontal deformation-induced frontogenesis.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The surface pressure-molecular area (pi-A) isotherms for Langmuir monolayers of four perylenetetracarboxylic (PTCD) derivatives, measured with varying subphase temperatures and compression speeds, are reported. The behavior of these PTCD derivatives at the water-air interface is modeled using the rigid docking method. This approach is the first attempt to model the molecular orientation of PTCD on the water surface to be compared with experimental Langmuir isotherms. Through this methodology, it would be possible to anticipate aggregation and determine if favorable spatial orientations of perylenes are generated on the water surface. The pi-A isotherm experiments show that these molecules can support high surface pressures, indicating strong packing on the water surface and that the isotherms are compression speed independent but temperature dependent. The molecular orientation and stacking was further examined in Langmuir-Blodgett (LB) monolayers deposited onto glass and glass coated with Ag island films using UV-visible absorption and surface-enhanced fluorescence (SEF) measurements.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This article presents a thermoeconomic analysis of cogeneration plants, applied as a rational technique to produce electric power and saturated steam. The aim of this new methodology is the minimum Exergetic Production Cost (EPC), based on the Second Law of Thermodynamics. The variables selected for the optimization are the pressure and the temperature of the steam leaving the boiler in the case of using steam turbine, and the pressure ratio, turbine exhaust temperature and mass flow in the case of using gas turbines. The equations for calculating the capital costs of the components and products are formulated as a function of these decision variables. An application of the method using real data of a multinational chemical industry located in São Paulo state is presented. The conditions which establish the minimum cost are presented as final output. (C) 2003 Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A pressure analgesiometric device was developed for unrestrained cats. Eleven cats were studied. Stimulation was via three rounded pins within a bracelet on the forearm. The pins were advanced by manual bladder inflation. Bladder pressure was measured using a strain gauge pressure transducer. The threshold was recorded at the behavioural end point. Thresholds were measured at 5 and 15 min intervals for 2-4 h, after removal/replacement of the cuff, for 120 min after SC butorphanol (0.4 mg/kg), and with mild skin inflammation at the testing site. Data were analysed using ANOVA. Pressure thresholds in untreated cats were around 150 mmHg. The minimum interval for testing was established as 15 min. Data were reproducible over 4 h and beyond 24 h. Thresholds in 5 cats increased (P < 0.05) above baseline for 45 min after butorphanol with a maximum increase of 270 +/- 182 mmHg at 10 min. Thresholds decreased with inflammation. The method appears suitable for feline analgesia investigations. (c) 2006 Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Some tendons wrap around joints and receive compressive forces besides transferring the tension forces from muscle to bone. These tendons develop a fibrocartilaginous structure which enables them to withstand pressure. This article describes the existence and distribution of microfibrils (or preelastic fibers) in the pressure-bearing tendons of rabbits and dogs by the application of histochemical assays and transmission electron microscopy. Rabbit and dog tendons possess no mature elastic fibers. The rabbit tendon exhibits some response to Weigert's method prior to oxidation which indicates the existence of the so-called elaunin fibers, especially in the pressure zone. Oxidation with peracetic acid or oxone discloses intricate aspects of the oxytalan fiber distribution in both tension and pressure zones of the dog and rabbit tendons. Bundles of 12 nm microfibrils were demonstrated in the rabbit tendon by electron microscopy after fixation in the presence of tannic acid. The existence of preelastic fibers in the pressure-bearing tendons has been neglected and they are assumed to have importance in the microarchitecture of the tissue and in the ability of the tendon to support tension and compression forces.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A competitive enzyme-linked immunosorbent assay (ELISA) method for carbaryl quantitation in crop extracts was validated by liquid chromatography (LC) with diode array detection (DAD). For this purpose, six crops (banana, carrot, green bean, orange, peach and potato) were chosen for recovery and reproducibility studies. The general sample preparation included extraction with methanol followed by liquid-liquid partitioning and clean-up on Celite-charcoal adsorbent column of the vegetable extracts. ELISA samples consisted of a diluted LC extract in assay phosphate buffer (pH 7.5). The potential effect of methanol in these samples was evaluated. It was observed that a maximum content of 10% methanol present in the assay buffer could be tolerated without expressive losses in the ELISA performance. Under these conditions, a IC50 similar to 1.48 mu g l(-1) was obtained. A minimum matrix effect with a 1:50 dilution of the methanolic extracts in assay buffer was noticed, except for green bean samples that inhibited completely the assay. For the vegetable extracts, the ELISA sensitivities varied from 3.9 to 5.7 mu g l(-1), and good recoveries (82-96%) with R.S.D.s ranging from 5.7 to 12.1% were found. An excellent correlation between the LC-DAD and ELISA techniques was obtained. The confirmation of the carbaryl in less concentrated samples was achieved by LC-mass spectrometry interfaced with atmospheric pressure chemical ionisation. The [M + H](+)= 202 and [M + H-57](+)=145 ions, equivalent to the protonated molecular and l-naphthol ions, respectively, were used to carbaryl identification in these samples. (C) 1998 Elsevier B.V. B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

An analytical method for the determination of aldicarb, and its two major metabolites, aldicarb sulfoxide and aldicarb sulfone in fruits and vegetables is described. Briefly the method consisted of the use of a methanolic extraction, liquid-liquid extraction followed by solid-phase extraction clean-up. Afterwards, the final extract is analyzed by liquid chromatography-atmospheric pressure chemical ionization mass spectrometry (LC-APCI-MS). The specific fragment ion corresponding to [M-74](+) and the protonated molecular [M+K](+) ion were used for the unequivocal determination of aldicarb and its two major metabolites. The analytical performance of the proposed method and the results achieved were compared with those obtained using the common analytical method involving LC with post-column fluorescence detection (FL). The limits of detection varied between 0.2 and 1.3 ng but under LC-FL were slightly lower than when using LC-APCI-MS. However both methods permitted one to achieve the desired sensitivity for analyzing aldicarb and its metabolites in vegetables. The method developed in this work was applied to the trace determination of aldicarb and its metabolites in crop and orange extracts. (C) 2000 Elsevier B.V. B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A 9.5/65/35 PLZT ceramic with a Pb-0.905 La-0.095 (Zr-0.65 Ti-0.35)(0.976) O-3 + 35 w% PbO formula was prepared using the Pechini method for powder preparation and two-step sintering in an oxygen atmosphere. Thr first step consisted of sintering at 1200 degrees C for 4 h with slow heating and cooling rates. The second step consisted of hot pressing at 1200 degrees C for 3 h, with slow heating and cooling rates and pressing pressures of 20 MPa (initial pressure) and 40 MPa (at sintering temperature). Investigations were made of the powder phase formation and powder morphology, i.e. The structure of sintered and hot-pressed PLZT ceramics. SEM microstructural analyses were carried out on the sintering and hot-pressing processes. (C) 2000 Elsevier B.V. Ltd and Techna S.r.l. All rights reserved.