845 resultados para Ocular prostheses
Resumo:
BACKGROUND: Cranial nerve schwannomas are radiologically characterized by nodular cranial nerve enhancement on magnetic resonance imaging (MRI). Schwannomas typically present with gradually progressive symptoms, but isolated reports have suggested that schwannomas may cause fluctuating symptoms as well. METHODS: This is a report of ten cases of presumed cranial nerve schwannoma that presented with transient or recurring ocular motor nerve deficits. RESULTS: Schwannomas of the third, fourth, and fifth nerves resulted in fluctuating deficits of all 3 ocular motor nerves. Persistent nodular cranial nerve enhancement was present on sequential MRI studies. Several episodes of transient oculomotor (III) deficts were associated with headaches, mimicking ophthalmoplegic migraine. CONCLUSIONS: Cranial nerve schwannomas may result in relapsing and remitting cranial nerve symptoms.
Resumo:
BACKGROUND: Digoxin intoxication results in predominantly digestive, cardiac and neurological symptoms. This case is outstanding in that the intoxication occurred in a nonagenarian and induced severe, extensively documented visual symptoms as well as dysphagia and proprioceptive illusions. Moreover, it went undiagnosed for a whole month despite close medical follow-up, illustrating the difficulty in recognizing drug-induced effects in a polymorbid patient. CASE PRESENTATION: Digoxin 0.25 mg qd for atrial fibrillation was prescribed to a 91-year-old woman with an estimated creatinine clearance of 18 ml/min. Over the following 2-3 weeks she developed nausea, vomiting and dysphagia, snowy and blurry vision, photopsia, dyschromatopsia, aggravated pre-existing formed visual hallucinations and proprioceptive illusions. She saw her family doctor twice and visited the eye clinic once until, 1 month after starting digoxin, she was admitted to the emergency room. Intoxication was confirmed by a serum digoxin level of 5.7 ng/ml (reference range 0.8-2 ng/ml). After stopping digoxin, general symptoms resolved in a few days, but visual complaints persisted. Examination by the ophthalmologist revealed decreased visual acuity in both eyes, 4/10 in the right eye (OD) and 5/10 in the left eye (OS), decreased color vision as demonstrated by a score of 1/13 in both eyes (OU) on Ishihara pseudoisochromatic plates, OS cataract, and dry age-related macular degeneration (ARMD). Computerized static perimetry showed non-specific diffuse alterations suggestive of either bilateral retinopathy or optic neuropathy. Full-field electroretinography (ERG) disclosed moderate diffuse rod and cone dysfunction and multifocal ERG revealed central loss of function OU. Visual symptoms progressively improved over the next 2 months, but multifocal ERG did not. The patient was finally discharged home after a 5 week hospital stay. CONCLUSION: This case is a reminder of a complication of digoxin treatment to be considered by any treating physician. If digoxin is prescribed in a vulnerable patient, close monitoring is mandatory. In general, when facing a new health problem in a polymorbid patient, it is crucial to elicit a complete history, with all recent drug changes and detailed complaints, and to include a drug adverse reaction in the differential diagnosis.
Resumo:
Thèse numérisée par la Division de la gestion de documents et des archives de l'Université de Montréal.
Resumo:
Resumen tomado del autor. Contiene fotograf??as y tablas de las diferentes situaciones experimentales
Resumo:
Se estimó la sensibilidad y especificidad de la citología de impresión como prueba diagnóstica en lesiones conjuntivales clínicamente sospechosas de neoplasia usando como patrón de oro la patología. Se estudiaron 60 pacientes, que ingresaron al azar a la Fundación Oftalmológica Nacional, con diagnóstico clínico de neoplasia de superficie ocular o lesión sospechosa de neoplasia, quienes fueron sometidos a citología de impresión y posterior resección quirúrgica completa, más estudio patológico de la lesión. Se realizó un análisis descriptivo, analizando la sensibilidad y la especificidad con el método clásico y análisis bayesiano.
Resumo:
Introducción: En la literatura, han aparecido reportes de neoplasia escamosa de superficie ocular (NESO) asociado con pterigio en un mismo paciente. Sin embargo, Colombia no cuenta con una estadística para ninguna de estas patologías. Objetivos: Determinar la frecuencia de NESO en pterigios resecados, en la Fundación Oftalmológica Nacional. Identificar factores de riesgo y características clínicas que predispongan a su aparición. Metodología: Estudio descriptivo de corte transversal. Se realizó una clasificación prequirúrgica y estudio histopatológico de los pterigios resecados en 93 pacientes, para confirmar su coexistencia con NESO. Se efectuó un análisis de frecuencias para datos demográficos y factores de riesgo asociados su aparición. Resultados: La frecuencia de NESO asociado a pterigio fue 7,07%. De estos, 28,5% identificados como sospechosos en la evaluación preoperatoria. La mayoría se presentaron en mujeres (71,4%), las ocupaciones con mayor frecuencia: labores domésticas (42,8%) y el comercio (28.5%). La exposición a derivados del petróleo y tabaquismo fue del 14,28%. No se presentaron casos asociados a infección por VIH. No hubo diferencias estadísticamente significativas sobre la presencia de NESO al comparar los casos en edad (p=0,8), procedencia (p=0,6) tabaquismo (p=0,4), leucoplaquia (p=1,0), queratinización (p=0,137), o vasos amputados (p=0,137). Conclusiones: De los pacientes con diagnóstico histopatológico de NESO, un porcentaje mínimo es sospechado clínicamente. Además se encontró este diagnóstico en pacientes más jóvenes que lo reportado en la literatura. Se recomienda realizar estudios con mayor número de pacientes para una mejor identificación de factores de riesgo. Palabras clave:
Resumo:
Monográfico con el título: 'Visión y deporte'. Resumen tomado de la publicación
Resumo:
Monográfico con el título: 'Visión y deporte'. Resumen tomado de la publicación
Resumo:
The primary objective of this research study is to determine if various body positions for ocular vestibular evoked myogenic potential (oVEMP) testing demonstrate differentiation of the saccule and utricle through threshold responses.
Resumo:
Background/aims: Scant consideration has been given to the variation in structure of the human amniotic membrane (AM) at source or to the significance such differences might have on its clinical transparency. Therefore, we applied our experience of quantifying corneal transparency to AM. Methods: Following elective caesarean, AM from areas of the fetal sac distal and proximal (ie, adjacent) to the placenta was compared with freeze-dried AM. The transmission of light through the AM samples was quantified spectrophotometrically; also, tissue thickness was measured by light microscopy and refractive index by refractometry. Results: Freeze-dried and freeze-thawed AM samples distal and proximal to the placenta differed significantly in thickness, percentage transmission of visible light and refractive index. The thinnest tissue (freeze-dried AM) had the highest transmission spectra. The thickest tissue (freeze-thawed AM proximal to the placenta) had the highest refractive index. Using the direct summation of fields method to predict transparency from an equivalent thickness of corneal tissue, AM was found to be up to 85% as transparent as human cornea. Conclusion: When preparing AM for ocular surface reconstruction within the visual field, consideration should be given to its original location from within the fetal sac and its method of preservation, as either can influence corneal transparency.
Resumo:
We have investigated the use of a laminin coated compressed collagen gel containing corneal fibroblasts (keratocytes) as a novel scaffold to support the growth of corneal limbal epithelial stem cells. The growth of limbal epithelial cells was compared between compressed collagen gel and a clinically proven conventional substrate, denuded amniotic membrane. Following compression of the collagen gel, encapsulated keratocytes remained viable and scanning electron microscopy showed that fibres within the compressed gel were dense, homogeneous and similar in structure to those within denuded amniotic membrane. Limbal epithelial cells were successfully expanded upon the compressed collagen resulting in stratified layers of cells containing desmosome and hemidesmosome structures. The resulting corneal constructs of both the groups shared a high degree of transparency, cell morphology and cell stratification. Similar protein expression profiles for cytokeratin 3 and cytokeratin 14 and no significant difference in cytokeratin 12 mRNA expression levels by real time PCR were also observed. This study provides the first line of evidence that a laminin coated compressed collagen gel containing keratocytes can adequately support limbal epithelial cell expansion, stratification and differentiation to a degree that is comparable to the leading conventional scaffold, denuded amniotic membrane.
Resumo:
Purpose: To assess the effect of hyaluronidase on eye and eyelid movements when used as an adjunct in sub-Tenon's anaesthesia. Methods: A total of 60 patients who had sub-Tenon's anaesthesia prior to phacoemulsification surgery were divided into two equal groups in a double-masked randomised controlled fashion. Of these, Group A had 4 ml lignocaine 2%, while Group B had 4ml lignocaine 2% with the addition of sodium hyaluronidase 75 IU/ml. Ocular motility, levator, and orbicularis oculi function were measured in all patients at 5 and 8 min. Levator function was scored from 0 (no function) to 3 (complete function) while orbicularis function was scored from 0 to 2. The score for ocular motility was the sum in four positions of gaze, each position scoring from 0 to 2. Results were compared using a nonparametric test. Results Group B achieved significantly better ocular and lid akinesia than Group A both at 5 and 8 min with P < 0.01. The median scores for levator function at 5 and 8 min were 2 for Group A and 0 for Group B. For orbicularis function, the median scores at both time intervals were 2 for Group A and 1 for Group B. For ocular motility, the median score for Group A at 5 min was 3 and at 8 min was 2.5; for Group B at 5 min was 0.5 and at 8 min was 0. Conclusions: The addition of hyaluronidase in sub-Tenon's anaesthesia has a significant effect in improving ocular and lid (levator and orbicularis) akinesia.
Resumo:
Historically, commercial hand prosthesis have adopted a low level of innovation mainly due to the strict conditions such a system must undergo. The difficult feedback to the prosthesis user has limited the functional range of commercial systems. Nevertheless, the use of advanced sensors in combination with performing hand mechanisms and microcontrollers could lead to more natural and functional prototypes. The Oxford and Manus intelligent hand prostheses are examples of innovative approaches. This paper compares and contrasts the technological solutions implemented in both systems to address the design conditions.
Resumo:
We compare the use of plastically compressed collagen gels to conventional collagen gels as scaffolds onto which corneal limbal epithelial cells (LECs) are seeded to construct an artificial corneal epithelium. LECs were isolated from bovine corneas (limbus) and seeded onto either conventional uncompressed or novel compressed collagen gels and grown in culture. Scanning electron microscopy (SEM) results showed that fibers within the uncompressed gel were loose and irregularly ordered, whereas the fibers within the compressed gel were densely packed and more evenly arranged. Quantitative analysis of LECs expansion across the surface of the two gels showed similar growth rates (p > 0.05). Under SEM, the LECs, expanded on uncompressed gels, showed a rough and heterogeneous morphology, whereas on the compressed gel, the cells displayed a smooth and homogeneous morphology. Transmission electron microscopy (TEM) results showed the compressed scaffold to contain collagen fibers of regular diameter and similar orientation resembling collagen fibers within the normal cornea. TEM and light microscopy also showed that cell–cell and cell–matrix attachment, stratification, and cell density were superior in LECs expanded upon compressed collagen gels. This study demonstrated that the compressed collagen gel was an excellent biomaterial scaffold highly suited to the construction of an artificial corneal epithelium and a significant improvement upon conventional collagen gels.