972 resultados para Heavy ion beam


Relevância:

90.00% 90.00%

Publicador:

Resumo:

Background: Heavy-flavor production in p + p collisions is a good test of perturbative-quantum-chromodynamics (pQCD) calculations. Modification of heavy-flavor production in heavy-ion collisions relative to binary-collision scaling from p + p results, quantified with the nuclear-modification factor (R-AA), provides information on both cold-and hot-nuclear-matter effects. Midrapidity heavy-flavor R-AA measurements at the Relativistic Heavy Ion Collider have challenged parton-energy-loss models and resulted in upper limits on the viscosity-entropy ratio that are near the quantum lower bound. Such measurements have not been made in the forward-rapidity region. Purpose: Determine transverse-momentum (p(T)) spectra and the corresponding R-AA for muons from heavy-flavor meson decay in p + p and Cu + Cu collisions at root s(NN) = 200 GeV and y = 1.65. Method: Results are obtained using the semileptonic decay of heavy-flavor mesons into negative muons. The PHENIX muon-arm spectrometers measure the p(T) spectra of inclusive muon candidates. Backgrounds, primarily due to light hadrons, are determined with a Monte Carlo calculation using a set of input hadron distributions tuned to match measured-hadron distributions in the same detector and statistically subtracted. Results: The charm-production cross section in p + p collisions at root s = 200 GeV, integrated over p(T) and in the rapidity range 1.4 < y < 1.9, is found to be d(sigma e (e) over bar)/dy = 0.139 +/- 0.029 (stat)(-0.058)(+0.051) (syst) mb. This result is consistent with a perturbative fixed-order-plus-next-to-leading-log calculation within scale uncertainties and is also consistent with expectations based on the corresponding midrapidity charm-production cross section measured by PHENIX. The R-AA for heavy-flavor muons in Cu + Cu collisions is measured in three centrality bins for 1 < p(T) < 4 GeV/c. Suppression relative to binary-collision scaling (R-AA < 1) increases with centrality. Conclusions: Within experimental and theoretical uncertainties, the measured charm yield in p + p collisions is consistent with state-of-the-art pQCD calculations. Suppression in central Cu + Cu collisions suggests the presence of significant cold-nuclear-matter effects and final-state energy loss.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

A systematic study is presented for centrality, transverse momentum (p(T)), and pseudorapidity (eta) dependence of the inclusive charged hadron elliptic flow (v(2)) at midrapidity (vertical bar eta vertical bar < 1.0) in Au + Au collisions at root s(NN) = 7.7, 11.5, 19.6, 27, and 39 GeV. The results obtained with different methods, including correlations with the event plane reconstructed in a region separated by a large pseudorapidity gap and four-particle cumulants (v(2){4}), are presented to investigate nonflow correlations and v(2) fluctuations. We observe that the difference between v(2){2} and v(2){4} is smaller at the lower collision energies. Values of v(2), scaled by the initial coordinate space eccentricity, v(2)/epsilon, as a function of p(T) are larger in more central collisions, suggesting stronger collective flow develops in more central collisions, similar to the results at higher collision energies. These results are compared to measurements at higher energies at the Relativistic Heavy Ion Collider (root s(NN) = 62.4 and 200 GeV) and at the Large Hadron Collider (Pb + Pb collisions at root s(NN) = 2.76 TeV). The v(2)(pT) values for fixed pT rise with increasing collision energy within the pT range studied (<2 GeV/c). A comparison to viscous hydrodynamic simulations is made to potentially help understand the energy dependence of v(2)(pT). We also compare the v(2) results to UrQMD and AMPT transport model calculations, and physics implications on the dominance of partonic versus hadronic phases in the system created at beam energy scan energies are discussed.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The PHENIX experiment has measured electrons and positrons at midrapidity from the decays of hadrons containing charm and bottom quarks produced in d + Au and p + p collisions at root S-NN = 200 GeV in the transverse-momentum range 0.85 <= p(T)(e) <= 8.5 GeV/c. In central d + Au collisions, the nuclear modification factor R-dA at 1.5 < p(T) < 5 GeV/c displays evidence of enhancement of these electrons, relative to those produced in p + p collisions, and shows that the mass-dependent Cronin enhancement observed at the Relativistic Heavy Ion Collider extends to the heavy D meson family. A comparison with the neutral-pion data suggests that the difference in cold-nuclear-matter effects on light- and heavy-flavor mesons could contribute to the observed differences between the pi(0) and heavy-flavor-electron nuclear modification factors R-AA. DOI: 10.1103/PhysRevLett.109.242301

Relevância:

90.00% 90.00%

Publicador:

Resumo:

We describe an approach to ion implantation in which the plasma and its electronics are held at ground potential and the ion beam is formed and injected energetically into a space held at high negative potential. The technique allows considerable savings both economically and technologically, rendering feasible ion implantation applications that might otherwise not be possible for many researchers and laboratories. Here, we describe the device and the results of tests demonstrating Nb implantation at 90 keV ion energy and dose about 2 x 10(16) cm(-2). (C) 2012 American Institute of Physics. [http://dx.doi.org/10.1063/1.4768699]

Relevância:

90.00% 90.00%

Publicador:

Resumo:

We describe an approach to ion implantation in which the plasma and its electronics are held at ground potential and the ion beam is injected into a space held at high negative potential, allowing considerable savings both economically and technologically. We used an “inverted ion implanter” of this kind to carry out implantation of gold into alumina, with Au ion energy 40 keV and dose (3–9) × 1016 cm−2. Resistivity was measured in situ as a function of dose and compared with predictions of a model based on percolation theory, in which electron transport in the composite is explained by conduction through a random resistor network formed by Au nanoparticles. Excellent agreement is found between the experimental results and the theory.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Hadron therapy is a promising technique to treat deep-seated tumors. For an accurate treatment planning, the energy deposition in the soft and hard human tissue must be well known. Water has been usually employed as a phantom of soft tissues, but other biomaterials, such as hydroxyapatite (HAp), used as bone substitute, are also relevant as a phantom for hard tissues. The stopping power of HAp for H+ and He+ beams has been studied experimentally and theoretically. The measurements have been done using the Rutherford backscattering technique in an energy range of 450-2000 keV for H+ and of 400-5000 keV for He+ projectiles. The theoretical calculations are based in the dielectric formulation together with the MELF-GOS (Mermin Energy-Loss Function – Generalized Oscillator Strengths) method [1] to describe the target excitation spectrum. A quite good agreement between the experimental data and the theoretical results has been found. The depth dose profile of H+ and He+ ion beams in HAp has been simulated by the SEICS (Simulation of Energetic Ions and Clusters through Solids) code [2], which incorporates the electronic stopping force due to the energy loss by collisions with the target electrons, including fluctuations due to the energy-loss straggling, the multiple elastic scattering with the target nuclei, with their corresponding nuclear energy loss, and the dynamical charge-exchange processes in the projectile charge state. The energy deposition by H+ and He+ as a function of the depth are compared, at several projectile energies, for HAp and liquid water, showing important differences.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Atomic physics plays an important role in determining the evolution stages in a wide range of laboratory and cosmic plasmas. Therefore, the main contribution to our ability to model, infer and control plasma sources is the knowledge of underlying atomic processes. Of particular importance are reliable low temperature dielectronic recombination (DR) rate coefficients. This thesis provides systematically calculated DR rate coefficients of lithium-like beryllium and sodium ions via ∆n = 0 doubly excited resonant states. The calculations are based on complex-scaled relativistic many-body perturbation theory in an all-order formulation within the single- and double-excitation coupled-cluster scheme, including radiative corrections. Comparison of DR resonance parameters (energy levels, autoionization widths, radiative transition probabilities and strengths) between our theoretical predictions and the heavy-ion storage rings experiments (CRYRING-Stockholm and TSRHeidelberg) shows good agreement. The intruder state problem is a principal obstacle for general application of the coupled-cluster formalism on doubly excited states. Thus, we have developed a technique designed to avoid the intruder state problem. It is based on a convenient partitioning of the Hilbert space and reformulation of the conventional set of pairequations. The general aspects of this development are discussed, and the effectiveness of its numerical implementation (within the non-relativistic framework) is selectively illustrated on autoionizing doubly excited states of helium.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

An dem Schwerionenspeicherring TSR (MPI für Kernphysik, Heidelberg) wurde ein 7 Li +-Ionenstrahl geringer Dichte durch RF-Bunchen und Laserkühlung präpariert.Die Phasenraumverteilung in dem Strahl wurde durch Laser- spektroskopie an Ionen im metastabilen Zustand untersucht. Ein umlaufsynchrones, zeitaufgelöstes Meßverfahren für das Fluoreszenzlicht ermöglichte die Bestimmung der räumlichen Struktur mit dieser rein optischen Methode.Durch einen speziellen Präparationsschritt wurden die Ionen im Grundzustand aus dem Speicherring entfernt. Der sonst dominierende Heizeffekt der strahlinternen Streuung war dadurch vernachlässigbar und es konnte eine Temperatur von 160 mK erreicht werden.Der präparierte Ionenstrahl bietet besondere Eigenschaften im Hinblick auf Präzisionsexperimente, bei denen mit möglichst ungestörten Ionen gearbeitet werden soll. Es wird gezeigt, daß die Phasenraumverteilung der Ionen nicht mehr durch Ion-Ion-Wechselwirkungen bestimmt ist und daß der verbleibende Heizmechanismus durch die Streuung am Restgas erklärt werden kann.1993 wurde durch Laserspektroskopie an 7 Li + im TSR die spezielle Relativitätstheorie im Hinblick auf die relativistische Zeitdilatation experimentell getestet. In diesem Zusammenhang wird das zu erwartende Ergebnis eines Experimentes diskutiert, das, basierend auf den in dieser Arbeit vorgestellten Verfahren, einen erneuten Test der relativistischen Zeitdilatation mit verbesserter Genauigkeit durchführen könnte.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

REX-ISOLDE ist ein Pilotexperiment zur Nachbeschleunigung radioaktiver Ionenstrahlen am on-line Massenseparator ISOLDE am CERN. Ein wichtiges Teilprojekt war die Realisierung der effizienten Umwandlung des kontinuierlichen niederenergetischen Ionenstrahles in kurze Ionenpulse hoher Qualität. Zu diesem Zweck wurde im Rahmen dieser Arbeit REXTRAP, eine gasgefüllte Penningfalle entwickelt, in Betrieb genommen und systematisch untersucht.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The Plasma Focus is a device designed to generate a plasma sheet between two coaxial electrodes by means of a high voltage difference. The plasma is then driven to collapse into a “pinch”, where thermonuclear conditions prevail. During the “pinch phase” charged particles are emitted, with two main components: an ion beam peaked forward and an electron beam directed backward. The electron beam emitted backward by Plasma Focus devices is being investigated as a radiation source for medical applications, using it to produce x-rays by interaction with appropriate targets (through bremsstrahlung and characteristic emission). A dedicated Plasma Focus device, named PFMA-3 (Plasma Focus for Medical Applications number 3), has been designed, put in operation and tested by the research groups of the Universities of Bologna and Ferrara. The very high dose rate (several gray per discharge, in less than 1 µs) is a peculiarity of this device that has to be investigated, as it might modify the relative biological effectiveness (RBE). Aim of this Ph.D. project was to investigate the main physical properties of the low-energy x-ray beams produced by a Plasma Focus device and their potential medical applications to IORT treatments. It was necessary to develop the optimal geometrical configuration; to evaluate the x-rays produced and their dose deposited; to estimate the energy electron spectrum produced in the “pinch phase”; to study an optimal target for the conversion of the x-rays; to conduct simulations to study the physics involved; and in order to evaluate the radio-biological features of the beam, cell holders had to be developed for both irradiations and cell growth conditions.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The subject of the presented thesis is the accurate measurement of time dilation, aiming at a quantitative test of special relativity. By means of laser spectroscopy, the relativistic Doppler shifts of a clock transition in the metastable triplet spectrum of ^7Li^+ are simultaneously measured with and against the direction of motion of the ions. By employing saturation or optical double resonance spectroscopy, the Doppler broadening as caused by the ions' velocity distribution is eliminated. From these shifts both time dilation as well as the ion velocity can be extracted with high accuracy allowing for a test of the predictions of special relativity. A diode laser and a frequency-doubled titanium sapphire laser were set up for antiparallel and parallel excitation of the ions, respectively. To achieve a robust control of the laser frequencies required for the beam times, a redundant system of frequency standards consisting of a rubidium spectrometer, an iodine spectrometer, and a frequency comb was developed. At the experimental section of the ESR, an automated laser beam guiding system for exact control of polarisation, beam profile, and overlap with the ion beam, as well as a fluorescence detection system were built up. During the first experiments, the production, acceleration and lifetime of the metastable ions at the GSI heavy ion facility were investigated for the first time. The characterisation of the ion beam allowed for the first time to measure its velocity directly via the Doppler effect, which resulted in a new improved calibration of the electron cooler. In the following step the first sub-Doppler spectroscopy signals from an ion beam at 33.8 %c could be recorded. The unprecedented accuracy in such experiments allowed to derive a new upper bound for possible higher-order deviations from special relativity. Moreover future measurements with the experimental setup developed in this thesis have the potential to improve the sensitivity to low-order deviations by at least one order of magnitude compared to previous experiments; and will thus lead to a further contribution to the test of the standard model.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

This doctoral thesis describes the extension of the resonance ionization laser ion source RILIS at CERN/ISOLDE by the addition of an all-solid state tunable titanium:sapphire (Ti:Sa) laser system to complement the well-established system of dye lasers. Synchronous operation of the so called Dual RILIS system of Ti:Sa and dye lasers was investigated and the potential for increased ion beam intensity, reliability, and reduced setup time has been demonstrated. In-source resonance ionization spectroscopy was performed at ISOLDE/CERN and at ISAC/TRIUMF radioactive ion beam facilities to develop an efficient and selective three-colour ionization scheme for the purely radioactive element astatine. A LabVIEW based monitoring, control and measurement system was conceived which enabled, in conjunction with Dual RILIS operation, the spectroscopy of high lying Rydberg states, from which the ionization potential of the astatine atom was determined for the first time experimentally.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Während ausgedehnter Weltraumflüge zum Mond und Mars wäre die Besatzung eines Raumschiffs dicht ionisierender Schwerionenstrahlung, der sogenannten kosmischen Strahlung, ausgesetzt. Da bei vielen Krebspatienten die orale Mukositis als eine gravierende Nebenwirkung bei der herkömmlichen Strahlentherapie auftritt, könnte diese Erkrankung ein medizinisches Problem während ausgedehnter Weltraumflüge darstellen. Allerdings liegen bislang keine Untersuchungen über eine mögliche Mukositis-induzierte Wirkung von Schwerionenstrahlung vor. Um das Risiko strahlungsinduzierter oraler Mukositis durch kosmische Strahlung abzuschätzen, wurden dreidimensionale organotypische Mundschleimhaut-Modelle 12C Schwerionen- bzw. Röntgenstrahlung ausgesetzt und nach definierten Inkubationszeiten kryokonserviert. Aus dem Material wurden Kryoschnitte gefertigt, mit denen anschließend histologische und immunhistologische Fluoreszenzfärbungen zum Nachweis von zum Beispiel Kompaktheitsverlust, Doppelstrangbrüchen der DNA und NF-κB-Aktivierung durchgeführt wurden. Die Ausschüttung von Tumornekrosefaktor α, Interleukin 1β, Interleukin 6 und Interleukin 8 wurde in Probenüberständen mittels ELISA analysiert. Das Hauptaugenmerk dieser Studie lag dabei auf den frühen durch Strahlung verursachten Effekten. rnIm Rahmen dieser Dissertation wurde ein dreidimensionales Mundschleimhaut-Modell etabliert, das verglichen mit humaner Mundschleimhaut viele organotypische Differenzierungsmarker und in vivo-ähnliche Reaktionen auf bestimmte Reize zeigte. Nach einer Bestrahlung mit schweren Kohlenstoffionen bzw. mit Röntgenstrahlung wurden strahlungsinduzierte Effekte auf mehreren Ebenen detektiert. Bereits 1 h nach Bestrahlung konnten dosisabhängig vermehrte Doppelstrangbrüche in der DNA detektiert werden, wobei bei gleicher Dosis Schwerionenstrahlung im Durchschnitt doppelt so viele DSB verursachte wie Röntgenstrahlung. Das Mundschleimhaut-Modell reagierte auf beide Strahlungsarten mit einer Aktivierung des Transkriptionsfaktors NF-κB p50, wobei Röntgenstrahlung diese Aktivierung früher induzierte als Schwerionen. Eine strahlungsinduzierte Aktivierung von NF-κB p65 wurde in den organotypischen Kulturen zu den untersuchten Zeitpunkten nicht beobachtet. Im Vergleich zu nicht bestrahlten Kulturen waren die Konzentrationen von Interleukin 6 und Interleukin 8 unabhängig von der Strahlungsqualität nach Bestrahlung signifikant erhöht. Interleukin-1β dagegen wurde nur nach Röntgenbestrahlung signifikant vermehrt ausgeschüttet. In Schwerionen-bestrahlten Proben wurden zwar tendenziell höhere Konzentrationen beobachtet, statistische Signifikanzen ergaben sich aber nicht. Die Analysen zur TNF-α- und IFN-γ-Ausschüttung in bestrahlten organotypischen Kulturen ergaben innerhalb des gewählten Beobachtungszeitraums von 48 h keine strahlungsinduzierten Effekte. Bei den Untersuchungen der Proliferation in den Zellen der bestrahlten organotypischen Kulturen wurde bereits 24 h nach Röntgenstrahlung und 3 Tage nach Schwerionenstrahlung eine deutliche verminderte Proliferation beobachtet. Des Weiteren zeigte das Mundschleimhaut-Modell unabhängig von Strahlungsqualitäten einen eindeutigen Verlust in der Zellintegrität und daraus resultierenden Kompaktheitsverlust des Gewebes, was in der in vivo-Situation wahrscheinlich einer Gewebedegeneration entspricht. rnNach Bestrahlung mit sowohl Röntgenstrahlung als auch schweren Ionen wurden im gewählten Mukosa-Modell innerhalb von 48 h nach Behandlung strahlungsinduzierte proinflammatorische Marker eindeutig und reproduzierbar detektiert. Dies deutet darauf hin, dass während langer extraterrestrischer Expeditionen das Risiko der oralen Mukositis einkalkuliert und mit den daraus folgenden Konsequenzen gerechnet werden muss.rn

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The thermal release rate of nuclear reaction products was investigated in offline annealing experiments. This work was motivated by the search for a high melting catcher material for recoiling products from heavy ion induced nuclear fusion reactions. Polycrystalline refractory metal foils of Ni, Y, Zr, Nb, Mo, Hf, W, and Re were investigated as catcher metals. Diffusion data for various tracer/host combinations were deduced from the measured release rates. This work focuses on the diffusion and the release rate of volatile p-elements from row 5 and 6 of the periodic table as lighter homologues of the superheavy elements with Z ≥ 113 to be studied in future experiments. A massive radiation damage enhancement of the diffusion velocity was observed. Diffusion trends have been established along the groups and rows of the periodic table based on the dependence of diffusion velocity on atomic sizes.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The European Rosetta mission on its way to comet 67P/Churyumov-Gerasimenko will remain for more than a year in the close vicinity (1 km) of the comet. The two ROSINA mass spectrometers on board Rosetta are designed to analyze the neutral and ionized volatile components of the cometary coma. However, the relative velocity between the comet and the spacecraft will be minimal and also the velocity of the outgassing particles is below 1km∕s. This combination leads to very low ion energies in the surrounding plasma of the comet, typically below 20eV. Additionally, the spacecraft may charge up to a few volts in this environment. In order to simulate such plasma and to calibrate the mass spectrometers, a source for ions with very low energies had to be developed for the use in the laboratory together with the different gases expected at the comet. In this paper we present the design of this ion source and we discuss the physical parameters of the ion beam like sensitivity, energy distribution, and beam shape. Finally, we show the first ion measurements that have been performed together with one of the two mass spectrometers.