957 resultados para mechanical stress


Relevância:

60.00% 60.00%

Publicador:

Resumo:

The magnetic behaviour of most commercial ferromagnetic steels is usually anisotropic presenting a magnetic easy axis. Changes in the direction of this axis can be related to mechanical changes and anomalies that occur in the fabrication process. The present work describes a method that uses a device with permanent magnets to create a precise rotational magnetic field. The device measures continuous Magnetic Barkhausen Noise signals related to the angle of magnetization, in order to determine the direction of the macroscopic magnetic easy axis. It also offers the possibility of obtaining real time parameters that quantify the magnetic anisotropy of the sample. (C) 2011 Elsevier Ltd. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Sepsis and septic shock are associated with cardiac depression. Cardiovascular instability is a major cause of death in patients with sepsis. Focal adhesion kinase (FAK) is a potential mediator of cardiomyocyte responses to oxidative and mechanical stress. Myocardial collagen deposition can affect cardiac compliance and contractility. The aim of the present study was to determine whether the silencing of FAK is protective against endotoxemia-induced alterations of cardiac structure and function. In male Wistar rats, endotoxemia was induced by intraperitoneal injection of lipopolysaccharide (10 mg/kg). Cardiac morphometry and function were studied in vivo by left ventricular catheterization and histology. Intravenous injection of small interfering RNA targeting FAK was used to silence myocardial expression of the kinase. The hearts of lipopolysaccharide-injected rats showed collagen deposition, increased matrix metalloproteinase 2 activity, and myocyte hypertrophy, as well as reduced 24-h +dP/dt and -dP/dt, together with hypotension, increased left ventricular end-diastolic pressure, and elevated levels of FAK (phosphorylated and unphosphorylated). Focal adhesion kinase silencing reduced the expression and activation of the kinase in cardiac tissue, as well as protecting against the increased collagen deposition, greater matrix metalloproteinase 2 activity, and reduced cardiac contractility that occur during endotoxemia. In conclusion, FAK is activated in endotoxemia, playing a role in cardiac remodeling and in the impairment of cardiac function. This kinase represents a potential therapeutic target for the protection of cardiac function in patients with sepsis.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Aim: This study compared the resistance to fracture of endodontically treated teeth restored with different intraradicular posts with different lengths and full coverage metallic crowns. Methods: Sixty extracted human canine teeth were randomly divided into 6 groups. Groups CP5, CP75 and CP10 were restored using custom cast post and core (CP) and groups PF5, PF75 and PF10 were restored with provisional pre-fabricated tin post (PF) and composite resin core at 5 mm, 7.5 mm and 10 mm of intraradicular length, respectively. The specimens were submitted to dynamic cyclic loading and those that resisted to this load were submitted to load compression using a universal testing machine. Compressive load was applied at a 45-degree angle to the long axis of the tooth until failure. Results: Kruskal-Wallis one-way analysis of variance by ranks showed statistically significant differences among the groups (p<0.0001). However, when the means were compared using the Tukey’s test, significant differences were noted between groups CP5 and CP10 and between groups CP10 and PF5. All groups presented root fractures and post displacements during mechanical cycling. All teeth in groups CP5 and PF5 failed the dynamic cycling test. Conclusions: This study showed that increasing intraradicular post length also increases resistance to fracture of endodontically treated teeth. On the other hand, most endodontically treated teeth restored with pre-fabricated tin posts (provisional posts) failed in the dynamic cycling test

Relevância:

60.00% 60.00%

Publicador:

Resumo:

New concepts on porosity appraisal in ancient and modern construction materials. The role of Fractal Geometry on porosity characterization and transport phenomena. This work studied the potential of Fractal Geometry to the characterization of porous materials. Besides the descriptive aspects of the pore size distribution, the fractal dimensions have led to the development of rational relations for the prediction of permeability coefficients to fluid and heat transfer. The research considered natural materials used in historical buildings (rock and earth) as well as currently employed materials as hydraulic cement and technologically advanced materials such as silicon carbide or YSZ ceramics. The experimental results of porosity derived from the techniques of mercury intrusion and from the image analysis. Data elaboration was carried out according to established procedures of Fractal Geometry. It was found that certain classes of materials are clearly fractal and respond to simple patterns such as Sierpinski and Menger models. In several cases, however, the fractal character is not recognised because the microstructure of the material is based on different phases at different dimensional scales, and in consequence the “fractal dimensions” calculated from porosimetric data do not come within the standard range (less than 3). Using different type and numbers of fractal units is possible, however, to obtain “virtual” microstructures that have the fraction of voids and pore size distribution equivalent with the experimental ones for almost any material. Thus it was possible to take the expressions for the permeability and the thermal conduction which does not require empirical “constants”, these expressions have also provided values that are generally in agreement with the experimental available data. More problematic has been the fractal discussion of the geometry of the rupture of the material subjected to mechanical stress both external and internal applied. The results achieved on these issues are qualitative and prone to future studies. Keywords: Materials, Microstructure, Porosity, Fractal Geometry, Permeability, Thermal conduction, Mechanical strength.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Entheses (skeletal attachment sites of muscles and ligaments) and their pathologic modifications (enthesopathies) have long been used as skeletal markers of activity in bioarchaeological (reconstruction of past populations lifestyle) and forensic (personal identification) contexts. However, a functional interpretation of these markers have to deal critically with the multifactorial etiology of the same. Factors such as sex, age, genetic factors, mechanical stress, metabolic conditions, etc.. can compete to produce the observed morphological variability at each attachment site. The aim of this thesis has drawn on the ongoing debate about the informativeness of entheseal modifications as skeletal markers of activity and represent a deepening of the actual knowledge about the relationship between these characters and sex, age and physical activity. For this purpose, the whole "Frassetto” identified skeletal collection of Sassari (Sardinia, Italy) was analyzed. The collection includes the skeletal remains of about 600 individuals died in the late 19th and early 20th century for whom information regarding sex, age at death and, in many cases the occupation are known The results obtained highlight the great age importance on the entheseal modifications. The differences observed between sexes may reflect differences in the level or type of activity performed in life, but could also be related to a different bone tissue response to mechanical stress due to hormonal factors and different growth rates. The role of biomechanical stress related to professional activities remains doubtful. This is probably partly attributable to the analyzed sample characteristics (preponderance of farmers compared with other professions, different mean age of the considered professional subsamples), which has hampered the analysis of samples homogenous with regard to age, which is very influential on the entheses and enthesopathies expression.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

To continuously improve the performance of metal-oxide-semiconductor field-effect-transistors (MOSFETs), innovative device architectures, gate stack engineering and mobility enhancement techniques are under investigation. In this framework, new physics-based models for Technology Computer-Aided-Design (TCAD) simulation tools are needed to accurately predict the performance of upcoming nanoscale devices and to provide guidelines for their optimization. In this thesis, advanced physically-based mobility models for ultrathin body (UTB) devices with either planar or vertical architectures such as single-gate silicon-on-insulator (SOI) field-effect transistors (FETs), double-gate FETs, FinFETs and silicon nanowire FETs, integrating strain technology and high-κ gate stacks are presented. The effective mobility of the two-dimensional electron/hole gas in a UTB FETs channel is calculated taking into account its tensorial nature and the quantization effects. All the scattering events relevant for thin silicon films and for high-κ dielectrics and metal gates have been addressed and modeled for UTB FETs on differently oriented substrates. The effects of mechanical stress on (100) and (110) silicon band structures have been modeled for a generic stress configuration. Performance will also derive from heterogeneity, coming from the increasing diversity of functions integrated on complementary metal-oxide-semiconductor (CMOS) platforms. For example, new architectural concepts are of interest not only to extend the FET scaling process, but also to develop innovative sensor applications. Benefiting from properties like large surface-to-volume ratio and extreme sensitivity to surface modifications, silicon-nanowire-based sensors are gaining special attention in research. In this thesis, a comprehensive analysis of the physical effects playing a role in the detection of gas molecules is carried out by TCAD simulations combined with interface characterization techniques. The complex interaction of charge transport in silicon nanowires of different dimensions with interface trap states and remote charges is addressed to correctly reproduce experimental results of recently fabricated gas nanosensors.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Die Analyse der Einflussfaktoren Kapselmaterial, Trägerlaktose, Additiv-Anteil, Mischreihenfolge und mechanische Belastung ergibt verschiedene Haupteinflussfaktoren und kombinierte Wechselwirkungen, die einen deutlichen Effekt auf die aerodynamischen Eigenschaften (ausgebrachte Dosis und Verteilung des aerodynamischen Feinanteils) haben. Sowohl das Kapselmaterial als auch die Trägerlaktose werden als primäre Einflussfaktoren identifiziert: Mit „inerten” PE-Kapseln lassen sich höhere Resultate erzielen als mit „adhäsiven” Gelatine-Kapseln, während „feines” Trägermaterial die Ausbringung stärker fördert, als „grobes“ Trägermaterial. Alles Faktoren, die sich in gleicher Weise auf die Verteilung des aerodynamischen Feinanteils auswirken. Der zur binären Mischung zugefügte Additiv-Anteil führt neben einem ausgeprägten kapselmaterialabhängigen Effekt auf die Höhe der ausgebrachten Dosis auch zu einer Steigerung in der Verteilung des aerodynamischen Feinanteils („Umhüllungseffekt”), was durch die Variation der Mischreihenfolge anschaulich nachgewiesen wird. Die anschließende detaillierte Charakterisierung der beobachteten Effekte auf Basis von Partikelmorphologie und Oberflächenstruktur der Kapseln führt zu einer Differenzierung in Partikel-Partikel-Wechselwirkungen (z.B. „Umhüllungseffekt”, „Multiplets“) und Partikel-Kapsel- Wechselwirkungen (z.B. „Auspudereffekt”). Durch Entwicklung von analytischen Verfahren wird eine Quantifizierung der Trägerlaktose möglich, was für den Nachweis einer positiven Korrelation zwischen den aerodynamischen Eigenschaften von Wirkstoff und Trägerlaktose notwendig ist. Sowohl für die ausgebrachte Dosis als auch für die Verteilung des aerodynamischen Feinanteils zeigt sich ein parallel verlaufender Anstieg der Ergebnisse.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The nervous system is the most complex organ in animals and the ordered interconnection of neurons is an essential prerequisite for normal behaviour. Neuronal connectivity requires controlled neuronal growth and differentiation. Neuronal growth essentially depends on the actin and microtubule cytoskeleton, and it has become increasingly clear, that crosslinking of these cytoskeletal fractions is a crucial regulatory process. The Drosophila Spectraplakin family member Short stop (Shot) is such a crosslinker and is crucial for several aspects of neuronal growth. Shot comprises various domains: An actin binding domain, a plakin-like domain, a rod domain, calcium responsive EF-hand motifs, a microtubule binding Gas2 domain, a GSR motif and a C-terminal EB1aff domain. Amongst other phenotypes, shot mutant animals exhibit severely reduced dendrites and neuromuscular junctions, the subcellular compartmentalisation of the transmembrane protein Fasciclin2 is affected, but it is also crucially required in other tissues, for example for the integrity of tendon cells, specialised epidermal cells which anchor muscles to the body wall. Despite these striking phenotypes, Shot function is little understood, and especially we do not understand how it can carry out functions as diverse as those described above. To bridge this gap, I capitalised on the genetic possibilities of the model system Drosophila melanogaster and carried out a structure-function analysis in different neurodevelopmental contexts and in tendon cells. To this end, I used targeted gene expression of existing and newly generated Shot deletion constructs in Drosophila embryos and larvae, analyses of different shot mutant alleles, and transfection of Shot constructs into S2 cells or cultured fibroblasts. My analyses reveal that a part of the Shot C-terminus is not essential in the nervous system but in tendon cells where it stabilises microtubules. The precise molecular mechanism underlying this activity is not yet elucidated but, based on the findings presented here, I have developed three alternative testable hypothesis. Thus, either binding of the microtubule plus-end tracking molecule EB1 through an EB1aff domain, microtubulebundling through a GSR rich motif or a combination of both may explain a context-specific requirement of the Shot C-terminus for tendon cell integrity. Furthermore, I find that the calcium binding EF-hand motif in Shot is exclusively required for a subset of neuronal functions of Shot but not in the epidermal tendon cells. These findings pave the way for complementary studies studying the impact of [Ca2+] on Shot function. Besides these differential requirements of Shot domains I find, that most Shot domains are required in the nervous system and tendon cells alike. Thus the microtubule Gas2 domain shows no context specific requirements and is equally essential in all analysed cellular contexts. Furthermore, I could demonstrate a partial requirement of the large spectrin-repeat rod domain of Shot in neuronal and epidermal contexts. I demonstrate that this domain is partially required in processes involving growth and/or tissue stability but dispensable for cellular processes where no mechanical stress resistance is required. In addition, I demonstrate that the CH1 domain a part of the N-terminal actin binding domain of Shot is only partially required for all analysed contexts. Thus, I conclude that Shot domains are functioning different in various cellular environments. In addition my study lays the base for future projects, such as the elucidation of Shot function in growth cones. Given the high degree of conservation between Shot and its mammalian orthologues MACF1/ACF7 and BPAG1, I believe that the findings presented in this study will contribute to the general understanding of spectraplakins across species borders.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

La dermoscopia, metodica non invasiva, di pratico utilizzo e a basso costo si è affermata negli ultimi anni come valido strumento per la diagnosi e il follow up delle lesioni cutanee pigmentate e non pigmentate. La presente ricerca è stata incentrata sullo studio dermoscopico dei nevi melanocitici a localizzazione palmo-plantare, acquisiti e congeniti, in età pediatrica: a questo scopo sono state analizzate le immagini dei nevi melanocitici acrali nei pazienti visitati c/o l’ambulatorio di Dermatologia Pediatrica del Policlinico Sant’Orsola Malpighi dal 2004 al 2011 per definire i principali pattern dermoscopici rilevati ed i cambiamenti osservati durante il follow up videodermatoscopico. Nella nostra casistica di immagini dermoscopiche pediatriche abbiamo notato un cambiamento rilevante (inteso come ogni modificazione rilevata tra il pattern demoscopico osservato al baseline e i successivi follow up) nell’88,6% dei pazienti ed in particolare abbiamo osservato come in un’alta percentuale di pazienti (80%), si sia verificato un vero e proprio impallidimento del nevo melanocitico e in un paziente è stata evidenziata totale regressione dopo un periodo di tempo di 36 mesi. E’ stato interessante notare come l’impallidimento della lesione melanocitaria si sia verificata per lo più in sedi sottoposte ad una sollecitazione meccanica cronica, come la pianta del piede e le dita (di mani e piedi), facendoci ipotizzare un ruolo del traumatismo cronico nelle modificazioni che avvengono nelle neoformazioni melanocitarie dei bambini in questa sede.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Solid oral dosage form disintegration in the human stomach is a highly complex process dependent on physicochemical properties of the stomach contents as well as on physical variables such as hydrodynamics and mechanical stress. Understanding the role of hydrodynamics and forces in disintegration of oral solid dosage forms can help to improve in vitro disintegration testing and the predictive power of the in vitro test. The aim of this work was to obtain a deep understanding of the influence of changing hydrodynamic conditions on solid oral dosage form performance. Therefore, the hydrodynamic conditions and forces present in the compendial PhEur/USP disintegration test device were characterized using a computational fluid dynamics (CFD) approach. Furthermore, a modified device was developed and the hydrodynamic conditions present were simulated using CFD. This modified device was applied in two case studies comprising immediate release (IR) tablets and gastroretentive drug delivery systems (GRDDS). Due to the description of movement provided in the PhEur, the movement velocity of the basket-rack assembly follows a sinusoidal profile. Therefore, hydrodynamic conditions are changing continually throughout the movement cycle. CFD simulations revealed that the dosage form is exposed to a wide range of fluid velocities and shear forces during the test. The hydrodynamic conditions in the compendial device are highly variable and cannot be controlled. A new, modified disintegration test device based on computerized numerical control (CNC) technique was developed. The modified device can be moved in all three dimensions and radial movement is also possible. Simple and complex moving profiles can be developed and the influence of the hydrodynamic conditions on oral solid dosage form performance can be evaluated. Furthermore, a modified basket was designed that allows two-sided fluid flow. CFD simulations of the hydrodynamics and forces in the modified device revealed significant differences in the fluid flow field and forces when compared to the compendial device. Due to the CNC technique moving velocity and direction are arbitrary and hydrodynamics become controllable. The modified disintegration test device was utilized to examine the influence of moving velocity on disintegration times of IR tablets. Insights into the influence of moving speed, medium viscosity and basket design on disintegration times were obtained. An exponential relationship between moving velocity of the modified basket and disintegration times was established in simulated gastric fluid. The same relationship was found between the disintegration times and the CFD predicted average shear stress on the tablet surface. Furthermore, a GRDDS was developed based on the approach of an in situ polyelectrolyte complex (PEC). Different complexes composed of different grades of chitosan and carrageenan and different ratios of those were investigated for their swelling behavior, mechanical stability, and in vitro drug release. With an optimized formulation the influence of changing hydrodynamic conditions on the swelling behavior and the drug release profile was demonstrated using the modified disintegration test device. Both, swelling behavior and drug release, were largely dependent on the hydrodynamic conditions. Concluding, it has been shown within this thesis that the application of the modified disintegration test device allows for detailed insights into the influence of hydrodynamic conditions on solid oral dosage form disintegration and dissolution. By the application of appropriate test conditions, the predictive power of in vitro disintegration testing can be improved using the modified disintegration test device. Furthermore, CFD has proven a powerful tool to examine the hydrodynamics and forces in the compendial as well as in the modified disintegration test device. rn

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Mechanical stress controls a broad range of cellular functions. The cytoskeleton is physically connected to the extracellular matrix via integrin receptors, and to the nuclear lamina by the LINC complex that spans both nuclear membranes. We asked here how disruption of this direct link from the cytoskeleton to nuclear chromatin affects mechanotransduction. Fibroblasts grown on flexible silicone membranes reacted to cyclic stretch by nuclear rotation. This rotation was abolished by inhibition of actomyosin contraction as well as by overexpression of dominant-negative versions of nesprin or sun proteins that form the LINC complex. In an in vitro model of muscle differentiation, cyclic strain inhibits differentiation and induces proliferation of C2C12 myoblasts. Interference with the LINC complex in these cells abrogated their stretch-induced proliferation, while stretch increased p38 MAPK and NFkappaB phosphorylation and the transcript levels of myogenic transcription factors MyoD and myogenin. We found that the physical link from the cytoskeleton to the nuclear lamina is crucial for correct mechanotransduction, and that disruption of the LINC complex perturbs the mechanical control of cell differentiation.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Plasmalemmal injury is a frequent event in the life of a cell. Physical disruption of the plasma membrane is common in cells that operate under conditions of mechanical stress. The permeability barrier can also be breached by chemical means: pathogens gain access to host cells by secreting pore-forming toxins and phospholipases, and the host's own immune system employs pore-forming proteins to eliminate both pathogens and the pathogen-invaded cells. In all cases, the influx of extracellular Ca(2+) is being sensed and interpreted as an "immediate danger" signal. Various Ca(2+)-dependent mechanisms are employed to enable plasma membrane repair. Extensively damaged regions of the plasma membrane can be patched with internal membranes delivered to the cell surface by exocytosis. Nucleated cells are capable of resealing their injured plasmalemma by endocytosis of the permeabilized site. Likewise, the shedding of membrane microparticles is thought to be involved in the physical elimination of pores. Membrane blebbing is a further damage-control mechanism, which is triggered after initial attempts at plasmalemmal resealing have failed. The members of the annexin protein family are ubiquitously expressed and function as intracellular Ca(2+) sensors. Most cells contain multiple annexins, which interact with distinct plasma membrane regions promoting membrane segregation, membrane fusion and--in combination with their individual Ca(2+)-sensitivity--allow spatially confined, graded responses to membrane injury.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This study investigates the mechanical implications of shell shape differences between males and females of two North American turtle species: Chrysemys picta and Glyptemys insculpta. These species show patterns of sexual dimorphism that are common to many species of turtle. Females have wider and more highly domed shells, whereas males tend to have flatter, more streamlined shells. In addition, the males of many terrestrial species have concave plastra, most likely to accommodate the domed shells of the females while mating. The purpose of this study was to determine whether the known morphological differences in male and female turtle shells are also associated with differences in shell strength. Landmark coordinate data were collected from the shells of males and females of both species. These data were used to create digital models of each shell for finite-element (FE) analysis. FE models were generated by transforming a single base model of a turtle shell to match the shapes of each specimen examined in this study. All models were assigned the same material properties and restraints. Twelve load cases, each representing a predator’s bite at a different location on the carapace, were applied separately to the models. Subsequently, Von Mises stresses were extracted for each element of each model. Overall, the shells of females of both species exhibited significantly lower maximum and average stresses for a given load than those of their male counterparts. Male G. insculpta exhibited significant increases in stresses because of the concave shape of their plastra. We suggest that the mechanical implications of shell shape differences between males and females may have a large impact on many aspects of the biology of these turtle species.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Low-intensity concentric (CET) and eccentric (EET) endurance-type training induce specific structural adaptations in skeletal muscle. We evaluated to which extent steady-state adaptations in transcript levels are involved in the compensatory alterations of muscle mitochondria and myofibrils with CET versus EET at a matched metabolic exercise intensity of medicated, stable coronary patients (CAD). Biopsies were obtained from vastus lateralis muscle before and after 8 weeks of CET (n=6) or EET (n=6). Transcript levels for factors involved in mitochondrial biogenesis (PGC-1alpha, Tfam), mitochondrial function (COX-1, COX-4), control of contractile phenotype (MyHC I, IIa, IIx) as well as mechanical stress marker (IGF-I) were quantified using an reverse-transcriptase polymerase chain reaction approach. After 8 weeks of EET, a reduction of the COX-4 mRNA level by 41% and a tendency for a drop in Tfam transcript concentration (-33%, P=0.06) was noted. This down-regulation corresponded to a drop in total mitochondrial volume density. MyHC-IIa transcript levels were specifically decreased after EET, and MyHC-I mRNA showed a trend towards a reduction (P=0.08). Total fiber cross-sectional area was not altered. After CET and EET, the IGF-I mRNA level was significantly increased. The PGC-1alpha significantly correlated with Tfam, and both PGC-1alpha and Tfam significantly correlated with COX-1 and COX-4 mRNAs. Post-hoc analysis identified significant interactions between the concurrent medication and muscular transcript levels as well as fiber size. Our findings support the concept that specific transcriptional adaptations mediate the divergent mitochondrial response of muscle cells to endurance training under different load condition and indicate a mismatch of processes related to muscle hypertrophy in medicated CAD patients.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The occurrence of degenerative spinal disease subsequent to dystonic movement disorders has been neglected and has received more attention only recently. Spinal surgery is challenging with regard to continuous mechanical stress when treatment of the underlying movement disorder is insufficient. To characterize better the particular features of degenerative spinal disease in patients with dystonia and to analyze operative strategies, we reviewed the available published data. Epidemiologic studies reveal that degenerative spinal disorders in patients with dystonia and choreoathetosis occur much earlier than in the physiological aging process. Dystonic movement disorders more often affect the spine at higher cervical levels (C(2-5)), in contrast to spinal degeneration with age which manifests more frequently at the middle and lower cervical spine (C(5-7)). Degenerative changes of the cervical spine are more likely to occur on the side where the chin is rotated or tilted to. Various operative approaches for treatment of spinal pathologies have been advocated in patients with dystonic movement disorders. The available data do not allow making firm statements regarding the superiority of one approach over the other. Posterior approaches were first used for decompression, but additional anterior fusion became necessary in many instances. Anterior approaches with or without instrumented fusion yielded more favorable results, but drawbacks are pseudarthrosis and adjacent-level disease. Parallel to the development of posterior fusion techniques, circumferential surgery was suggested to provide a maximum degree of cord decompression and a higher fusion rate. Perioperative local injections of botulinum toxin were used initially to enhance patient comfort with halo immobilization, but they are also applied in patients without external fixation nowadays. Treatment algorithms directed at the underlying movement disorder itself, taking advantage of new techniques of functional neurosurgery, combined with spinal surgery have recently been introduced and show promising results.