889 resultados para liquid chromatographic


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Purpose: To investigate the antioxidant and anticancer activities of phenolics from the leaf extract of Toona sinensis (TS). Methods: Acetone leaf extract of TS was screened for total phenolic and flavanoid contents, and the flanonoids were subjected to high performance liquid chromatographic (HPLC) analysis. Antioxidant properties were assessed via oxygen radical absorbance capacity (ORAC), peroxyl radical scavenging capacity (PSC) and cellular antioxidant activity (CAA), while anti-proliferative activity ins HepG2 cell line was assessed using methylene blue assay. Results: The extract contained 36.02 ± 0.24 mg of gallic acid equiv/g dry weight (DW) and 20.24 ± 1.73 mg of catechin equiv/g DW of total phenolic and total flavonoid, respectively. The levels of rutin and quercitrin were 0.51 and 19.55 mg/g, respectively. Epicatechin, gallic acid, quercitin, isoquercetin were not detected. The extract showed significant antioxidant potential and high anti-proliferation capacity with low cytotoxicity against HepG2 cell in vitro. The underlying mechanism of anti-proliferative effect was induction of apoptosis. Conclusion: TS leaf extract possesses significant in vitro antioxidant properties and anti-proliferative effect against HepG2 cells, which make it a potential anticancer drug source.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

We performed a comprehensive study to assess the fit for purpose of four chromatographic conditions for the determination of six groups of marine lipophilic toxins (okadaic acid and dinophysistoxins, pectenotoxins, azaspiracids, yessotoxins, gymnodimine and spirolides) by LC-MS/MS to select the most suitable conditions as stated by the European Union Reference Laboratory for Marine Biotoxins (EURLMB). For every case, the elution gradient has been optimized to achieve a total run-time cycle of 12 min. We performed a single-laboratory validation for the analysis of three relevant matrices for the seafood aquaculture industry (mussels, pacific oysters and clams), and for sea urchins for which no data about lipophilic toxins have been reported before. Moreover, we have compared the method performance under alkaline conditions using two quantification strategies: the external standard calibration (EXS) and the matrix-matched standard calibration (MMS). Alkaline conditions were the only scenario that allowed detection windows with polarity switching in a 3200 QTrap mass spectrometer, thus the analysis of all toxins can be accomplished in a single run, increasing sample throughput. The limits of quantification under alkaline conditions met the validation requirements established by the EURLMB for all toxins and matrices, while the remaining conditions failed in some cases. The accuracy of the method and the matrix effects where generally dependent on the mobile phases and the seafood species. The MMS had a moderate positive impact on method accuracy for crude extracts, but it showed poor trueness for seafood species other than mussels when analyzing hydrolyzed extracts. Alkaline conditions with EXS and recovery correction for OA were selected as the most proper conditions in the context of our laboratory. This comparative study can help other laboratories to choose the best conditions for the implementation of LC-MS/MS according to their own necessities.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A method using Liquid Phase Microextraction for simultaneous detection of citalopram (CIT), paroxetine (PAR) and fluoxetine (FLU), using venlafaxine as internal standard, in plasma by high performance liquid chromatography with fluorescence detection was developed. The linearity was evaluated between 5.0 and 500 ng mL-1 (r > 0.99) and the limit of quantification was 2.0, 3.0 and 5.0 ng mL-1 for CIT, PAR and FLU, respectively. Therefore, it can be applied to therapeutic drug monitoring, pharmacokinetics or bioavailability studies and its advantages are that it necessary relatively inexpensive equipment and sample preparation techniques.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A method using HPTLC for quantitation of nifedipine in serum was developed and validated. It includes a liquid-liquid extraction, and carbamazepine as internal standard. Chloroform: ethyl acetate: cyclohexane (19:2:2, v/v/v) was the mobile phase. The method showed good relationship (r = 0.996) (2.00 to 25.00 ng/band, corresponding to 0.02 and 0.25 ng/µL in serum). The % RSD of intra-assay and inter-assay, were between 0.57 and 3.56 and 1.16 to 3.60, respectively. LOD and LOQ were 0.72 and 0.86 ng/band, respectively. The recovery values were between 93 and 102%. Rf for nifedipine and carbamazepine were 0.31 and 0.10, respectively.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A method using Liquid Phase Microextraction for simultaneous detection of citalopram (CIT), paroxetine (PAR) and fluoxetine (FLU), using venlafaxine as internal standard, in plasma by high performance liquid chromatography with fluorescence detection was developed. The linearity was evaluated between 5.0 and 500 ng mL(-1) (r > 0.99) and the limit of quantification was 2.0, 3.0 and 5.0 ng mL-1 for CIT. PAR and FLU, respectively. Therefore, it can be applied to therapeutic drug monitoring, pharmacokinetics or bioavailability studies and its advantages are that it necessary relatively inexpensive equipment and sample preparation techniques.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A method using Liquid Phase Microextraction for simultaneous detection of citalopram (CIT), paroxetine (PAR) and fluoxetine (FLU), using venlafaxine as internal standard, in plasma by high performance liquid chromatography with fluorescence detection was developed. The linearity was evaluated between 5.0 and 500 ng mL-1 (r > 0.99) and the limit of quantification was 2.0, 3.0 and 5.0 ng mL-1 for CIT, PAR and FLU, respectively. Therefore, it can be applied to therapeutic drug monitoring, pharmacokinetics or bioavailability studies and its advantages are that it necessary relatively inexpensive equipment and sample preparation techniques.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A rapid, sensitive and specific method for quantifying propylthiouracil in human plasma using methylthiouracil as the internal standard (IS) is described. The analyte and the IS were extracted from plasma by liquid-liquid extraction using an organic solvent (ethyl acetate). The extracts were analyzed by high performance liquid chromatography coupled with electrospray tandem mass spectrometry (HPLC-MS/MS) in negative mode (ES-). Chromatography was performed using a Phenomenex Gemini C18 5μm analytical column (4.6mm×150mm i.d.) and a mobile phase consisting of methanol/water/acetonitrile (40/40/20, v/v/v)+0.1% of formic acid. For propylthiouracil and I.S., the optimized parameters of the declustering potential, collision energy and collision exit potential were -60 (V), -26 (eV) and -5 (V), respectively. The method had a chromatographic run time of 2.5min and a linear calibration curve over the range 20-5000ng/mL. The limit of quantification was 20ng/mL. The stability tests indicated no significant degradation. This HPLC-MS/MS procedure was used to assess the bioequivalence of two propylthiouracil 100mg tablet formulations in healthy volunteers of both sexes in fasted and fed state. The geometric mean and 90% confidence interval CI of Test/Reference percent ratios were, without and with food, respectively: 109.28% (103.63-115.25%) and 115.60% (109.03-122.58%) for Cmax, 103.31% (100.74-105.96%) and 103.40% (101.03-105.84) for AUClast. This method offers advantages over those previously reported, in terms of both a simple liquid-liquid extraction without clean-up procedures, as well as a faster run time (2.5min). The LOQ of 20ng/mL is well suited for pharmacokinetic studies. The assay performance results indicate that the method is precise and accurate enough for the routine determination of the propylthiouracil in human plasma. The test formulation with and without food was bioequivalent to reference formulation. Food administration increased the Tmax and decreased the bioavailability (Cmax and AUC).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Obesity and endogenous hyperadrenocorticism (HAC) are common clinical conditions in veterinary practice, and both conditions have clinical and laboratory similarities, Such as weight gain and dyslipidemia. The objective of the present study was to characterize and compare the lipid profiles and plasma lipoprotein fractions in healthy dogs (n = 10), in obese dogs (n = 10), and in dogs with HAC (n = 6). All of the dogs were client owned. The lipoproteins were separated by fast protein liquid chromatography, and the plasma concentrations of total cholesterol and total triacylglycerol (TAG) were determined by enzymatic methods. When compared with the healthy and obese groups, dogs with HAC had a significant increase (P < 0.01) in the total concentrations of TAGs and cholesterol (CHOL), with higher distribution in the very low-density lipoprotein (VLDL)-CHOL fractions. In addition, the distributions of the high-density lipoprotein (HDL)-CHOL and HDL-TAG fractions were significantly lower (P < 0.01) in dogs with HAC than in healthy dogs. Considering the animals in this study, it was determined that the dogs with HAC differed significantly from the healthy and obese dogs regarding the metabolism of CHOL and TAG, as well as their VLDL and HDL fractions. Similar laboratory findings could allow veterinarians to distinguish obese dogs from those with HAC. In addition, dogs with HAC may be at higher risk for developing metabolic and atherosclerotic complications.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

An analytical procedure for multiple standard additions of arsenic species using sequential injection analysis (SIA) is proposed for their quantification in seafood extracts. SIA presented flexibility for generating multiple specie standards at the ng mL(-1) concentration level by adding different volumes of As(III), As(V), monomethylarsonic (MMA) and dimethylarsinic (DMA) to the sample. The mixed sample plus standard solutions were delivered from SIA to fill the HPLC injection loop. Subsequently, As species were separated by HPLC and analyzed by atomic fluorescence spectrometry (AFS). The proposed system comprised two independently controlled modules, with the HPLC loop acting as the intermediary device. The analytical frequency was enhanced by combining the actions of both modules. While the added sample was flowing through the chromatographic column towards the detection system, the SIA program started performing the standard additions to another sample. The proposed method was applied to spoiled seafood extracts. Detection limits based on 3 sigma for As(III), As(V), MMA and DMA were 0.023, 0.39, 0.45 and 1.0 ng mL(-1), respectively. (C) 2011 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Liquid-liquid microextraction without phase segmentation was implemented in a multicommuted flow system for determination of the anti-hypertensive diltiazem. The procedure was based on ion pair formation between the drug and the dye bromothymol blue at pH 3.5. The detection was performed without phase separation in a glass tube coupled to a fiber-optics spectrophotometer. The total volume of chloroform was reduced to 50 mu L in comparison with 10 mL consumed in batch. A linear response was observed between 9 and 120 mu mol L(-1), with a detection limit of 0.9 mu mol L(-1) (99.7% confidence level). The coefficient of variation (n = 10), sampling rate and extraction efficiency were estimated as 0.6%, 78 determinations per hour and 61%, respectively. About 30 mu g of bromothymol blue was consumed and the waste volume was 380 mu L per determination. The results for pharmaceutical samples agreed with those obtained by the reference procedure at the 95% confidence level. (C) 2011 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Anatoxin-a(s) is a potent irreversible inhibitor of the enzyme acetylcholinesterase with a unique N-hydroxyguanidine methylphosphate ester chemical structure. Determination of this toxin in environmental samples is hampered by the lack of specific methods for its detection. Using the toxic strain of Anabaena lemmermani PH-160 B as positive control, the fragmentation characteristics of anatoxin-a(s) under collision-induced dissociation conditions have been investigated and new LC-MS/MS methods proposed. Recommended ion transitions for correct detection of this toxin are 253 > 58, 253 > 159, 235 > 98 and 235 > 96. Chromatographic separation is better achieved under HILIC conditions employing a ZIC-HILIC column. This method was used to confirm for the first time the production of anatoxin-a(s) by strains of Anabaena oumiana ITEP-025 and ITEP-026. Considering no standard solutions are commercially available, our results will be of significant use for the correct identification of this toxin by LC-MS/MS. (C) 2009 Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study describes an accurate, sensitive, and specific chromatographic method for the simultaneous quantitative determination of lamivudine and zidovudine in human blood plasma, using stavudine as an internal standard. The chromatographic separation was performed using a C8 column (150 x 4.6 mm, 5 mu m), and ultraviolet absorbency detection at 270 nm with gradient elution. Two mobile phases were used. Phase A contained 10 mM potassium phosphate and 3% acetonitrile, whereas Phase B contained methanol. A linear gradient was used with a variability of A-B phase proportion from 98-2% to 72-28%, respectively. The drug extraction was performed with two 4 mL aliquots of ethyl acetate.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A selective method using three-phase liquid-phase microextraction (LPME) in conjunction with LC-MS-MS was devised for the enantioselective determination of chloroquine and its n-dealkylated metabolites in plasma samples. After alkalinization of the samples, the analytes were extracted into n-octanol immobilized in the pores of a polypropylene hollow fiber membrane and back extracted into the acidic acceptor phase (0.1 M TFA) filled into the lumen of the hollow fiber. Following LPME, the analytes were resolved on a Chirobiotic V column using methanol/ACN/glacial aceti acid/diethylamine (90:10:0.5:0.5 by volume) as the mobile phase. The MS detection was carried out using multiple reaction monitoring with ESI in the positive ion mode. The optimized LPME method yielded extraction recoveries ranging from 28 to 66%. The method was linear over 5 - 500 ng/mL and precision (RSD) and accuracy (relative error) values were below 15% for all analytes. The developed method was applied to the determination of the analytes in rat plasma samples after oral administration of the racemic drug.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A three-phase liquid-phase microextraction (LPME) method using porous polypropylene hollow fibre membrane with a sealed end was developed for the extraction of mirtazapine (MRT) and its two major metabolites, 8-hydroxymirtazapine (8-OHM) and demethylmirtazapine (DMR), from human plasma. The analytes were extracted from 1.0 mL of plasma, previously diluted and alkalinized with 3.0 mL 0.5 mol L-1 pH 8 phosphate buffer solution and supplemented with 15% sodium chloride (NaCl), using n-hexyl ether as organic solvent and 0.01 moL L-1 acetic acid solution as the acceptor phase. Haloperidol was used as internal standard. The chromatographic analyses were carried out on a chiral column, using acetonitrile-methanol-ethanol (98:1:1, v/v/v) plus 0.2% diethylamine as mobile phase, at a flow rate of 1.0 mL min(-1). Multi-reaction monitoring (MRM) detection was performed by mass spectrometry (MS-MS) using a triple-stage quadrupole and electrospray ionization interface operating in the positive ion mode. The mean recoveries were in 18.3-45.5% range with linear responses over the 1.25-125 ng mL(-1) concentration range for all enantiomers evaluated. The quantification limit (LOQ) was 1.25 ng mL(-1). Within-day and between-day assay precision and accuracy (2.5, 50 and 100 ng mL(-1)) showed relative standard deviation and the relative error lower than 11.9% for all enantiomers evaluated. Finally, the method was successfully used for the determination of mirtazapine and its metabolite enantiomers in plasma samples obtained after single drug administration of mirtazapine to a healthy volunteer. (c) 2007 Elsevier B.V. All rights reserved.