861 resultados para compression force
Resumo:
The success of artificial prosthetic replacements depends on the fixation of the artificial prosthetic component after being implanted in the thighbone. The materials for fixation are subject to mechanical stresses, which originate permanent deformations, incipient cracks and even fatigue fractures. This work shows the possibility of monitoring the mechanical stress over time in prosthesis. In this way, highly sensitive silicon thin-film piezoresistive sensors were developed attached to prosthesis and their results compared with commercial strain gauge sensors. Mechanical stress-strain experiments were performed in compressive mode, during 10,000 cycles. Experimental data was acquired at mechanical vibration frequencies of 0.5 Hz, 1 Hz and 5 Hz, and sent to a computer by means of a wireless link. The results show that there is a decrease in sensitivity of the thin-film silicon piezoresistive sensors when they are attached to the prosthesis, but this decrease does not compromise its monitoring performance. The sensitivity, compared to that of commercial strain gauges, is much larger due to their higher gauge factors (-23.5), when compared to the GFs of commercial sensors (2).
Resumo:
Familial Amyloidotic Polyneuropathy FAP)- A neurodegenerative disease related with systemic deposition of amyloid fibers mainly at the level of the peripheral nervous system. Clinically, the disease is characterized by an autonomous sensitive-motor neuropathy, beginning nearly always in foot, and subsequently involving the hands. Purpose: Compare the levels of hand grip strength (peak force) in FAP patients with (FAPT) or without (FAPNT) liver transplant and in a healthy group (HG).
Resumo:
The Wyner-Ziv video coding (WZVC) rate distortion performance is highly dependent on the quality of the side information, an estimation of the original frame, created at the decoder. This paper, characterizes the WZVC efficiency when motion compensated frame interpolation (MCFI) techniques are used to generate the side information, a difficult problem in WZVC especially because the decoder only has available some reference decoded frames. The proposed WZVC compression efficiency rate model relates the power spectral of the estimation error to the accuracy of the MCFI motion field. Then, some interesting conclusions may be derived related to the impact of the motion field smoothness and the correlation to the true motion trajectories on the compression performance.
Resumo:
Lossless compression algorithms of the Lempel-Ziv (LZ) family are widely used nowadays. Regarding time and memory requirements, LZ encoding is much more demanding than decoding. In order to speed up the encoding process, efficient data structures, like suffix trees, have been used. In this paper, we explore the use of suffix arrays to hold the dictionary of the LZ encoder, and propose an algorithm to search over it. We show that the resulting encoder attains roughly the same compression ratios as those based on suffix trees. However, the amount of memory required by the suffix array is fixed, and much lower than the variable amount of memory used by encoders based on suffix trees (which depends on the text to encode). We conclude that suffix arrays, when compared to suffix trees in terms of the trade-off among time, memory, and compression ratio, may be preferable in scenarios (e.g., embedded systems) where memory is at a premium and high speed is not critical.
Resumo:
The effects of the Miocene through Present compression in the Tagus Abyssal Plain are mapped using the most up to date available to scientific community multi-channel seismic reflection and refraction data. Correlation of the rift basin fault pattern with the deep crustal structure is presented along seismic line IAM-5. Four structural domains were recognized. In the oceanic realm mild deformation concentrates in Domain I adjacent to the Tore-Madeira Rise. Domain 2 is characterized by the absence of shortening structures, except near the ocean-continent transition (OCT), implying that Miocene deformation did not propagate into the Abyssal Plain, In Domain 3 we distinguish three sub-domains: Sub-domain 3A which coincides with the OCT, Sub-domain 3B which is a highly deformed adjacent continental segment, and Sub-domain 3C. The Miocene tectonic inversion is mainly accommodated in Domain 3 by oceanwards directed thrusting at the ocean-continent transition and continentwards on the continental slope. Domain 4 corresponds to the non-rifted continental margin where only minor extensional and shortening deformation structures are observed. Finite element numerical models address the response of the various domains to the Miocene compression, emphasizing the long-wavelength differential vertical movements and the role of possible rheologic contrasts. The concentration of the Miocene deformation in the transitional zone (TC), which is the addition of Sub-domain 3A and part of 3B, is a result of two main factors: (1) focusing of compression in an already stressed region due to plate curvature and sediment loading; and (2) theological weakening. We estimate that the frictional strength in the TC is reduced in 30% relative to the surrounding regions. A model of compressive deformation propagation by means of horizontal impingement of the middle continental crust rift wedge and horizontal shearing on serpentinized mantle in the oceanic realm is presented. This model is consistent with both the geological interpretation of seismic data and the results of numerical modelling.
Resumo:
The dynamics of a cylinder rolling on a horizontal plane acted on by an external force applied at an arbitrary angle is studied with emphasis on the directions of the acceleration of the centre-of-mass and the angular acceleration of the body. If rolling occurs without slipping, there is a relationship between the directions of these accelerations. If the linear acceleration points to the right, then the angular acceleration is clockwise. On the other hand, if it points to the left, then the angular acceleration is counterclockwise. In contrast, if rolling and slipping occurs, the direction of the linear acceleration does not determine the direction of the angular acceleration. For example, the linear acceleration may point to the right and the angular acceleration clockwise or counterclockwise depending on the external force orientation and point of application.
Resumo:
O documento em anexo encontra-se na versão pre-print (versão inicial enviada para o editor).
Resumo:
O documento em anexo encontra-se na versão post-print (versão corrigida pelo editor).
Resumo:
Este trabalho descreve as actividades desenvolvidas no âmbito de uma task-force para revitalizar a função Sistemas de Informação de uma grande empresa nacional. Apresenta, em particular, o sistema de indicadores de gestão definido nesse contexto
Resumo:
Purpose: Evaluate the type of breast compression (gradual or no gradual) that provides less discomfort to the patient. Methods and Materials: The standard projections were simulated [craniocaudal/(CC) and mediolateral-oblique/(MLO)] with the two breast compressions in 90 volunteers women aged between 19 and 86. The women were organised in groups according to the breast density. The intensity of discomfort was evaluated using the scale that have represented several faces (0-10) proposed by Wong Baker in the end of each simulation. It was also applied an interview using focus group to debate the score that were attributed during pain evaluation and to identify the criteria that were considered to do the classification. Results: The women aged between 19-29y (with higher breast density) classified the pain during no gradual compression as 4 and the gradual compression as 2 for both projections. The MLO projection was considered the most uncomfortable. During the focus group interview applied to this group was highlighted that compression did not promoted pain but discomfort. They considered that the high expectations of pain did not correspond to the discomfort that they felt. Similar results were identified for the older women (30-50y; > 50y). Conclusion: The radiographers should considerer the technique for breast compression. The gradual compression was considered for the majority of the women as the most comfortable regardless of breast density. The MLO projection was considered as uncomfortable due to the positioning (axila and inclusion of pectoral muscle) and due to the higher breast compression compared to the CC projection.
Resumo:
Arguably, the most difficult task in text classification is to choose an appropriate set of features that allows machine learning algorithms to provide accurate classification. Most state-of-the-art techniques for this task involve careful feature engineering and a pre-processing stage, which may be too expensive in the emerging context of massive collections of electronic texts. In this paper, we propose efficient methods for text classification based on information-theoretic dissimilarity measures, which are used to define dissimilarity-based representations. These methods dispense with any feature design or engineering, by mapping texts into a feature space using universal dissimilarity measures; in this space, classical classifiers (e.g. nearest neighbor or support vector machines) can then be used. The reported experimental evaluation of the proposed methods, on sentiment polarity analysis and authorship attribution problems, reveals that it approximates, sometimes even outperforms previous state-of-the-art techniques, despite being much simpler, in the sense that they do not require any text pre-processing or feature engineering.
Resumo:
Após o enquadramento da canoagem, como modalidade Olímpica, verificou-se um aumento significativo de estudos e pesquisas acerca da biomecânica da modalidade, o que contribuiu para uma diminuição dos tempos na competição. Contudo poucos foram os que se focaram nas forças desenvolvidas e aplicadas ao caiaque através do finca-pés, criado assim oportunidade de desenvolvimento de dispositivos para a medição das mesmas. Assim, o objectivo primordial é desenvolver um sistema experimental capaz de quantificar as forças geradas em cada um dos lados do finca-pés (esquerdo e direito). Este, deverá não só ser passível de se utilizar em caiaque ergómetro como também num caiaque de pista, permitido avaliar as forças aplicadas durante o ciclo de pagaiada, tanto em compressão como em tracção. A sua concepção baseou-se num modelo de finca-pés já existente, tornando-o compatível com os caiaques de competição mais comercializados, e permitindo que no futuro se possa utilizar na água, bastando para isso apenas possuir um caiaque e embarcar o sistema de medição. Este sistema experimental foi testado em caiaque ergómetro por 7 (sete) sujeitos com níveis distintos: seis homens (um atleta olímpico medalhado e cinco de nível nacional) e uma mulher (de nível de selecção Portuguesa) que, entre outros, realizaram um plano definido por 60s a uma frequência de 75 pagaiadas por minuto, seguido de uma intensa mudança de ritmo e força (Sprint). Após análise dos dados obtidos em cada um dos diferentes sujeitos, conseguimos identificar algumas das suas características, tais como: esforço assimétrico dos membros inferiores; utilização de forma heterogénea da fita do finca-pés; diferença de forças máximas aplicadas entre atletas (Ex.: para um atleta olímpico as forças medidas (Min; Max): Pé Esquerdo (- 444; 1087) N e Pé Direito (- 476; 1068) N); etc. Os resultados não só são bastante promissores como também são motivantes e congruentes com estudos anteriores, nomeadamente Begon et al. 2008 e Sturm 2010 e 2012. Finalmente, consegue-se afirmar, com segurança, que foram alcançados os objectivos propostos com a concepção deste dispositivo de medição de forças. Este permite caracterizar os esforços desenvolvidos no finca-pés por cada membro inferior, com ou sem a fita de suporte, possibilitando aos treinadores e atletas uma visão, para muitos desconhecida, das forças transmitidas e das suas assimetrias. No final, este conhecimento permitirá aos atletas melhorar o seu desempenho desportivo bem como facilitar a gestão desportiva, com base nos principais princípios mecânicos inerentes ao movimento dos atletas desde desporto Olímpico.
Resumo:
The objective of the article is to evaluate the impact of the friction force mouse-pad in the contraction level of the forearm muscles M. extensor carpi ulnaris, M. extensor digitorum and M. extensor carpi radialis longus. A standard protocol of mouse movements was performed involving horizontal, vertical and diagonal mouse displacements drag-and-drop type. The operators were instructed to execute the protocol with their normal working speed. The movements protocol were performed by each subject (n=17) with three selected pairs mouse-pad, classified as low, medium and high friction force pairs. The mean time to execute the protocol with each mouse was ~138s. Mean values of ~13%MVE and ~17%MVE were found in the M. extensor carpi ulnaris and in the M. extensor digitorum respectively when performing the movements’ protocol. A 8.1% increase in %MVE was observed in the M. extensor digitorum and a 9.4% increase in %MVE was observed in the M. extensor carpi ulnaris when the high friction force pair was operated, relatively to the low friction force pair (p<0.05). The main preliminary conclusions of this study is that operating a high friction force mouse-pad may increase the risk to symptoms or disorders in the wrist due to an increase in the forearm muscles contraction levels, particularly during work with drawing application
Resumo:
Coarse Grained Reconfigurable Architectures (CGRAs) are emerging as enabling platforms to meet the high performance demanded by modern applications (e.g. 4G, CDMA, etc.). Recently proposed CGRAs offer time-multiplexing and dynamic applications parallelism to enhance device utilization and reduce energy consumption at the cost of additional memory (up to 50% area of the overall platform). To reduce the memory overheads, novel CGRAs employ either statistical compression, intermediate compact representation, or multicasting. Each compaction technique has different properties (i.e. compression ratio, decompression time and decompression energy) and is best suited for a particular class of applications. However, existing research only deals with these methods separately. Moreover, they only analyze the compaction ratio and do not evaluate the associated energy overheads. To tackle these issues, we propose a polymorphic compression architecture that interleaves these techniques in a unique platform. The proposed architecture allows each application to take advantage of a separate compression/decompression hierarchy (consisting of various types and implementations of hardware/software decoders) tailored to its needs. Simulation results, using different applications (FFT, Matrix multiplication, and WLAN), reveal that the choice of compression hierarchy has a significant impact on compression ratio (up to 52%), decompression energy (up to 4 orders of magnitude), and configuration time (from 33 n to 1.5 s) for the tested applications. Synthesis results reveal that introducing adaptivity incurs negligible additional overheads (1%) compared to the overall platform area.
Resumo:
Relatório de Estágio apresentado para cumprimento dos requisitos necessários à obtenção do grau de Mestre em Ciência Política e Relações Internacionais, na variante de Estudos Europeus