999 resultados para MOLDAGEM ODONTOLÓGICA
Resumo:
The aim of this study was to compare two methods of surface roughness analysis, perfilometry and spectrophotometry, applied to the surface of ionomeric materials (Chelon Fil, Vitremer and Dyract), submitted to different surface finishing treatments. For the perfilometric analysis, sixty specimens of each material were made and randomly separated into three experimental groups. The average surface roughness (Ra, mm) was measured on each specimen by a surface perfilometer (Mitutoyo Surftest 211). The spectrophotometric analysis consisted in quantifying the dye impregnated in the samples. The dyes used were 0.5% fuchsin and 0.5% erythrosin. Data were submitted to variance analysis (ANOVA) and t-Student test at a 0.05 significance level. There was no linear correlation between average roughness and superficial deposition of dye. Perfilometric analysis revealed that 12- and 30-bladed carbide burs caused the roughest surface of Chelon Fil, followed by Sof-Lex discs and mylar band. There were no significant differences between the specimens submitted to finishing and polishing with Sof-Lex discs and the control group (mylar band) for Vitremer, nevertheless, the highest Ra values were obtained when 12- and 30-bladed burs were used. For Dyract, there was no significant difference between the three treatments. The mean values of superficial deposition of dye for Chelon Fil, Vitremer and Dyract were: 1.7261, 1.4759, 1.3318, respectively. There were no significant differences between the restorative materials when different finishing and polishing systems were used.
Resumo:
The aim of this study was to determine the effectiveness and reliability of laser fluorescence measurements in relation to occlusal caries diagnosis. DIAGNOdent 2095 (Kavo, Biberach, Germany), which has been developed especially for caries diagnosis, was utilized. Five (5) teeth were examined in the pilot test; after that, ten (10) teeth were examined in order to calibrate both examiners. Data were obtained from 66 teeth (36 molars and 30 premolars), totalizing 144 sites identified through photographs of the occlusal surfaces. Reproducibility was evaluated in 10 teeth. The interexaminer Spearman correlation (r) was 0.89 and the intra-examiner, 0.93 and 0.97 (examiner A and B, respectively). Validation was carried out by histological examination (stereomicroscope). For the two examiners the sensitivity of the device was relatively high, varying from 0.81 to 1.00, while specificity varied according to which validation criterion was used (0.77 - 0.86: enamel lesion / 0.52 - 0.59: dentin lesion). It was concluded that DIAGNodent presented good capacity of identifying any alteration of the dental surface, nevertheless it presents the disadvantage of accomplishing many false-positive diagnosis when the validation criterion is dentin lesion.
Estudo comparativo dos métodos de estimativa da idade óssea de Greulich & Pyle e Tanner & Whitehouse
Resumo:
The purpose of this study was to verify whether the Greulich & Pyle (GP), Greulich & Pyle Visual (GPV) and Tanner & Whitehouse (TW) methods for estimating skeletal age could be applied in the Brazilian population, and which of these three methods could be considered more reliable when compared with the chronological age of the individuals. This study was based on one hundred and sixty volunteers (80 females and 80 males) with ages between 6 years and 10 months and 14 years and 9 months. The results showed that for the GP method, the correlations with chronological age were 0.95 for males and 0.97 for females. For the GPV method, the correlations were 0.96 and 0.97, respectively and for TW, 0.96 and 0.97. The results showed that the Greulich & Pyle, Greulich & Pyle Visual and Tanner & Whitehouse methods presented high correlation values when compared with the chronological age of the individuals. Corrective factors were established to make these methods applicable to the Brazilian population.
Resumo:
The present work evaluated the effect of low doses of X-irradiation on the repairing process of sutured and nonsutured skin wounds in rats. For that, rats underwent a surgical proceedure, in which a 20 x 5-millimeter rectangular wound approximately 2-millimeter-deep was made in the dorsal region of each animal, and were divided in four groups: nonirradiated nonsutured; irradiated nonsutured ; nonirradiated sutured and irradiated sutured. The animals under irradiation were protected, during exposure, with a 2-millimeter-thick lead apron in such a way that only the incision was irradiated. Each animal was submitted to 18 seconds of exposure, undergoing a total of 7.4 rads. The evaluation of the effects of X-rays on the repairing process was carried out through microscopic observation by means of hematoxylin-eosin staining for morphological evaluation, and silver impregnation under polarized light for the observation of collagen synthesis. The results have shown that X-irradiation has caused delay in the repairing process, but it did not stop its development. The irradiated nonsutured group was considered to show the greater delay when compared with the other groups.
Resumo:
O consentimento do paciente antes do início de qualquer procedimento é uma condição a ser respeitada pelos profissionais da odontologia, sem nenhuma exceção. É necessário que o paciente esteja ciente de seu status de saúde, de suas necessidades específicas, do propósito de cada tratamento, conheça os planejamentos alternativos (incluindo o não tratamento), saiba do seu prognóstico, riscos, consequências, limitações e se conscientize das suas responsabilidades e as do seu cirurgião-dentista, proporcionando o sucesso do tratamento. O termo de consentimento livre e esclarecido (TCLE) visa fortalecer e esclarecer a posição do paciente, estabelecendo os direitos e deveres de ambas as partes paciente e profissional. O conhecimento integral do tratamento diminuirá a ansiedade do paciente e as complicações de tratamento, promoverá maior qualidade dos serviços odontológicos e maior satisfação do dentista e do paciente. Entretanto, no Brasil, poucos artigos são encontrados e existem alguns problemas éticos envolvendo as clínicas odontológicas, no que diz respeito a este documento de esclarecimento para o paciente. Diante disso, este trabalho tem por objetivo realizar uma revisão crítica sobre o tema abordado, demonstrando a importância do TCLE na clínica odontológica brasileira e na vida profissional dos cirurgiões-dentistas.
Resumo:
The aim of this study was to comparatively assess dental arch width, in the canine and molar regions, by means of direct measurements from plaster models, photocopies and digitized images of the models. The sample consisted of 130 pairs of plaster models, photocopies and digitized images of the models of white patients (n = 65), both genders, with Class I and Class II Division 1 malocclusions, treated by standard Edgewise mechanics and extraction of the four first premolars. Maxillary and mandibular intercanine and intermolar widths were measured by a calibrated examiner, prior to and after orthodontic treatment, using the three modes of reproduction of the dental arches. Dispersion of the data relative to pre- and posttreatment intra-arch linear measurements (mm) was represented as box plots. The three measuring methods were compared by one-way ANOVA for repeated measurements (α = 0.05). Initial / final mean values varied as follows: 33.94 to 34.29 mm / 34.49 to 34.66 mm (maxillary intercanine width); 26.23 to 26.26 mm / 26.77 to 26.84 mm (mandibular intercanine width); 49.55 to 49.66 mm / 47.28 to 47.45 mm (maxillary intermolar width) and 43.28 to 43.41 mm / 40.29 to 40.46 mm (mandibular intermolar width). There were no statistically significant differences between mean dental arch widths estimated by the three studied methods, prior to and after orthodontic treatment. It may be concluded that photocopies and digitized images of the plaster models provided reliable reproductions of the dental arches for obtaining transversal intra-arch measurements.
Resumo:
This study evaluated the superficial microhardness of enamel in teeth at different posteruptive ages (before eruption in the oral cavity, 2-3 years after eruption, 4-10 years after eruption and more than 10 years after eruption). The study sample was composed of 134 specimens of human enamel. One fragment of each tooth was obtained from the flattest central portion of the crown to produce specimens with 3 x 3 mm. The enamel blocks were minimally flattened out and polished in order to obtain a flat surface parallel to the base, which is fundamental for microhardness testing. Microhardness was measured with a microhardness tester and a Knoop diamond indenter, under a static load of 25 g applied for 5 seconds. Comparison between the superficial microhardness obtained for the different groups was performed by analysis of Student's t test. The results demonstrated that superficial microhardness values have a tendency to increase over the years, with statistically significant difference only between unerupted enamel and that with more than 10 years after eruption. According to the present conditions and methodology, it was concluded that there were differences between the superficial micro-hardness of specimens at different eruptive ages, revealing an increasing mineralization. However, this difference was significant only between unerupted specimens and those with more than 10 years after eruption.
Resumo:
This in situ study investigated, using scanning electron microscopy, the effect of stimulated saliva on the enamel surface of bovine and human substrates submitted to erosion followed by brushing abrasion immediately or after one hour. During 2 experimental 7-day crossover phases, 9 previously selected volunteers wore intraoral palatal devices, with 12 enamel specimens (6 human and 6 bovine). In the first phase, the volunteers immersed the device for 5 minutes in 150 ml of a cola drink, 4 times a day (8h00, 12h00, 16h00 and 20h00). Immediately after the immersions, no treatment was performed in 4 specimens (ERO), 4 other specimens were immediately brushed (0 min) using a fluoride dentifrice and the device was replaced into the mouth. After 60 min, the other 4 specimens were brushed. In the second phase, the procedures were repeated but, after the immersions, the volunteers stimulated the salivary flow rate by chewing a sugar-free gum for 30 min. Enamel superficial alterations of all specimens were then evaluated using a scanning electron microscope. Enamel prism core dissolution was seen on the surfaces submitted to erosion, while on those submitted to erosion and to abrasion (both at 0 and 60 min) a more homogeneous enamel surface was observed, probably due to the removal of the altered superficial prism layer. For all the other variables - enamel substrate and salivary stimulation -, the microscopic pattern of the enamel specimens was similar.
Resumo:
The objective of this study was to assess the salivary residual effect of fluoride dentifrice on human enamel subjected to an erosive challenge. This crossover in situ study was performed in two phases (A and B), involving ten volunteers. In each phase, they wore acrylic palatal appliances, each containing 3 human enamel blocks, during 7 days. The blocks were subjected to erosion by immersion of the appliances in a cola drink for 5 minutes, 4 times a day. Dentifrice was used to brush the volunteers’ teeth, 4 times a day, during 1 minute, before the appliance was replaced into the mouth. In phases A and B the dentifrices used had the same formulation, except for the absence (PD) or presence (FD) of fluoride, respectively. Enamel alterations were determined using profilometry, microhardness (%SMHC), acid- and alkali-soluble F analysis. The data were tested using ANOVA (p < 0.05). The concentrations (mean ± SD) of alkali- and acid-soluble F (µgF/cm²) were, respectively, PD: 1.27ª ± 0.70/2.24A ± 0.36 and FD: 1.49ª ± 0.44/2.24A ± 0.67 (p > 0.05). The mean wear values (± SD, µm) were PD: 3.63ª ± 1.54 and FD: 3.54ª ± 0.90 (p > 0.05). The mean %SMHC values (± SD) were PD: 89.63ª ± 4.73 and FD: 87.28ª ± 4.01 (p > 0.05). Thus, we concluded that the residual fluoride from the fluoride-containing dentifrice did not protect enamel against erosion.
Resumo:
The present study aimed to compare the fluoride (F-) release pattern of a nanofilled resin-modified glass ionomer cement (GIC) (Ketac N100 - KN) with available GICs used in dental practice (resin-modified GIC - Vitremer - V; conventional GIC - Ketac Molar - KM) and a nanofilled resin composite (Filtek Supreme - RC). Discs of each material (n=6) were placed into 4 mL of deionized water in sealed polyethylene vials and shaken, for 15 days. F- release (μg F-/cm²) was measured each day using a fluoride-ion specific electrode. Cumulative F- release means were statistically analyzed by linear regression analysis. In order to analyze the differences among materials and the influence of time in the daily F- release, 2-way ANOVA test was performed (α=0.05). The linear fits between the cumulative F- release profiles of RC and KM and time were weak. KN and V presented a strong relationship between cumulative F- release and time. There were significant differences between the daily F- release overtime up to the third day only for GICs materials. The daily F- release means for RC were similar overtime. The results indicate that the F- release profile of the nanofilled resin-modified GIC is comparable to the resin-modified GIC.
Resumo:
Dental impression is an important step in the preparation of prostheses since it provides the reproduction of anatomic and surface details of teeth and adjacent structures. The objective of this study was to evaluate the linear dimensional alterations in gypsum dies obtained with different elastomeric materials, using a resin coping impression technique with individual shells. A master cast made of stainless steel with fixed prosthesis characteristics with two prepared abutment teeth was used to obtain the impressions. References points (A, B, C, D, E and F) were recorded on the occlusal and buccal surfaces of abutments to register the distances. The impressions were obtained using the following materials: polyether, mercaptan-polysulfide, addition silicone, and condensation silicone. The transfer impressions were made with custom trays and an irreversible hydrocolloid material and were poured with type IV gypsum. The distances between identified points in gypsum dies were measured using an optical microscope and the results were statistically analyzed by ANOVA (p < 0.05) and Tukey's test. The mean of the distances were registered as follows: addition silicone (AB = 13.6 µm, CD=15.0 µm, EF = 14.6 µm, GH=15.2 µm), mercaptan-polysulfide (AB = 36.0 µm, CD = 36.0 µm, EF = 39.6 µm, GH = 40.6 µm), polyether (AB = 35.2 µm, CD = 35.6 µm, EF = 39.4 µm, GH = 41.4 µm) and condensation silicone (AB = 69.2 µm, CD = 71.0 µm, EF = 80.6 µm, GH = 81.2 µm). All of the measurements found in gypsum dies were compared to those of a master cast. The results demonstrated that the addition silicone provides the best stability of the compounds tested, followed by polyether, polysulfide and condensation silicone. No statistical differences were obtained between polyether and mercaptan-polysulfide materials.
Resumo:
This study investigated the effects of the cement type and the water storage time on the push-out bond strength of a glass fiber post. Glass fiber posts (Fibrekor, Jeneric Pentron) were luted to post spaces using a self-cured resin cement (C&B Cement [CB]), a glass ionomer cement (Ketac Cem [KC]) or a resin-modified glass ionomer cement (GC FujiCEM [FC]) according to the manufacturers’ instructions. For each luting agent, the specimens were exposed to one of the following water storage times (n=5): 1 day (T1), 7 days (T7), 90 days (T90) and 180 days (T180). Push-out tests were performed after the storage times. Control specimens were not exposed to water storage, but subjected to the push-out test 10 min after post cementation. Data (in MPa) were analyzed by Kruskal-Wallis and Dunn`s test (α=0.05). Cement type and water storage time had a significant effect (p<0.05) on the push-out bond strength. CB showed significantly higher values of retention (p<0.05) than KC and FC, irrespective of the water storage time. Water storage increased significantly the push-out bond strength in T7 and T90, regardless of the cement type (p<0.05). The results showed that fiber posts luted to post spaces with the self-cured resin cement exhibited the best bonding performance throughout the 180-day water storage period. All cements exhibited a tendency to increase the bond strength after 7 and 90 days of water storage, decreasing thereafter.
Resumo:
The aim of this study was to investigate the fracture strength of endodontically treated teeth restored with different posts and variable ferrule heights. Sixty freshly extracted human canines were treated endodontically and randomly assigned to 6 groups (n=10), being restored with custom-made cast post-and-core (CP0 and CP3 groups), prefabricated post and composite resin core (PF0 and PF3 groups), and composite resin (CR0 and CR3 groups). The CP0, PF0 and CR0 groups presented no ferrule and the CP3, PF3 and CR3 presented 3 mm of coronal structure. All teeth were restored with full metal crowns. The fracture strength was measured in a universal testing machine at 45o to the long axis of the tooth until failure. Data were analyzed statistically by 2-way ANOVA and Tukey's test (?=0.05). When the mean fracture strength values were compared (CP0 group - 820.20 N, CP3 group - 1179.12 N; PF0 group - 561.05 N; PF3 group - 906.79 N; CR0 group - 297.84 N; and CR3 group - 1135.15 N) there was statistically significant among the groups (p<0.05), except for the three groups with 3 mm of coronal remaining, which were similar to each other. The results of this study showed that the ferrule in crowns promoted significantly higher fracture strength in the endodontically treated teeth.
Resumo:
This study evaluated the fracture resistance of weakened roots restored with glass fiber posts, composite resin cores and complete metal crowns. Thirty maxillary canines were randomly divided into 3 groups of 10 teeth each: teeth without weakened roots (control); teeth with partially weakened roots (PWR) and teeth with and largely weakened roots (LWR). The control group was restored with glass fiber posts and a composite resin core. Teeth in the PWR and LWR groups were flared internally to standardized dimensions in order to simulate root weakness. Thereafter, the roots were partially filled with composite resin and restored in the same way as in the control group. The specimens were exposed to 250,000 cycles in a controlled chewing simulator. All intact specimens were subjected to a static load (N) in a universal testing machine at 45 degrees to the long axis of the tooth until failure. Data were analyzed by one-way ANOVA and Dunnett's test for multiple comparisons (p=0.05). There were statistically significant difference differences (p<0.01) among the groups (control group = 566.73 N; PWR = 409.64 N; and LWR = 410.91 N), with significantly higher fracture strength for the control group. There was no statistically significant difference (p>0.05) between the weakened groups. The results of this study showed that thicker root dentin walls significantly increase the fracture resistance of endodontically treated teeth.
Resumo:
Among the different properties that influence bone apposition around implants, the chemical or biochemical composition of implant surface may interfere on its acceptance by the surrounding bone. The aim of this study was to investigate if a biofunctionalization of implant surface influences the bone apposition in a dog model and to compare it with other surfaces, such as a microstructured created by the grit-blasting/acid-etching process. Eight young adult male mongrel dogs had the bilateral mandibular premolars extracted and each one received 6 implants after 12 weeks, totaling 48 implants in the experiment. Four groups of implants were formed with the same microrough topography with or without some kind of biofunctionalization treatment. After histomorphometric analysis, it was observed that the modified microstructured surface with a "low concentration of the bioactive peptide" provided a higher adjacent bone density (54.6%) when compared to the other groups (microstructured + HA coating = 46.0%, microstructured only = 45.3% and microstructured + "high concentration of the bioactive peptide" = 40.7%), but this difference was not statistically significant. In conclusion, biofunctionalization of the implant surface might interfere in the bone apposition around implants, especially in terms of bone density. Different concentrations of bioactive peptide lead to different results.