895 resultados para Low voltage systems
Resumo:
Nanostructures are highly attractive for future electrical energy storage devices because they enable large surface area and short ion transport time through thin electrode layers for high power devices. Significant enhancement in power density of batteries has been achieved by nano-engineered structures, particularly anode and cathode nanostructures spatially separated far apart by a porous membrane and/or a defined electrolyte region. A self-aligned nanostructured battery fully confined within a single nanopore presents a powerful platform to determine the rate performance and cyclability limits of nanostructured storage devices. Atomic layer deposition (ALD) has enabled us to create and evaluate such structures, comprised of nanotubular electrodes and electrolyte confined within anodic aluminum oxide (AAO) nanopores. The V2O5- V2O5 symmetric nanopore battery displays exceptional power-energy performance and cyclability when tested as a massively parallel device (~2billion/cm2), each with ~1m3 volume (~1fL). Cycled between 0.2V and 1.8V, this full cell has capacity retention of 95% at 5C rate and 46% at 150C, with more than 1000 charge/discharge cycles. These results demonstrate the promise of ultrasmall, self-aligned/regular, densely packed nanobattery structures as a testbed to study ionics and electrodics at the nanoscale with various geometrical modifications and as a building block for high performance energy storage systems[1, 2]. Further increase of full cell output potential is also demonstrated in asymmetric full cell configurations with various low voltage anode materials. The asymmetric full cell nanopore batteries, comprised of V2O5 as cathode and prelithiated SnO2 or anatase phase TiO2 as anode, with integrated nanotubular metal current collectors underneath each nanotubular storage electrode, also enabled by ALD. By controlling the amount of lithium ion prelithiated into SnO2 anode, we can tune full cell output voltage in the range of 0.3V and 3V. This asymmetric nanopore battery array displays exceptional rate performance and cyclability. When cycled between 1V and 3V, it has capacity retention of approximately 73% at 200C rate compared to 1C, with only 2% capacity loss after more than 500 charge/discharge cycles. With increased full cell output potential, the asymmetric V2O5-SnO2 nanopore battery shows significantly improved energy and power density. This configuration presents a more realistic test - through its asymmetric (vs symmetric) configuration – of performance and cyclability in nanoconfined environment. This dissertation covers (1) Ultra small electrochemical storage platform design and fabrication, (2) Electron and ion transport in nanostructured electrodes inside a half cell configuration, (3) Ion transport between anode and cathode in confined nanochannels in symmetric full cells, (4) Scale up energy and power density with geometry optimization and low voltage anode materials in asymmetric full cell configurations. As a supplement, selective growth of ALD to improve graphene conductance will also be discussed[3]. References: 1. Liu, C., et al., (Invited) A Rational Design for Batteries at Nanoscale by Atomic Layer Deposition. ECS Transactions, 2015. 69(7): p. 23-30. 2. Liu, C.Y., et al., An all-in-one nanopore battery array. Nature Nanotechnology, 2014. 9(12): p. 1031-1039. 3. Liu, C., et al., Improving Graphene Conductivity through Selective Atomic Layer Deposition. ECS Transactions, 2015. 69(7): p. 133-138.
Resumo:
The concept of microgrid (μGrid) has been emerging as a way to integrate microgeneration (μG) in low-voltage (LV) networks and simultaneously improve its potential benefits. Technical requirements to connect μgrids to LV networks have been studied in order to make this concept technologically feasible and safe to operate. However, the regulatory framework for economic integration of μG and μGrids on distribution systems, despite being crucial, is still an open issue. The main purpose of this paper is to contribute for the development of an appropriate economic regulation framework that removes the barriers to μG and μGrid development. To do so, the relevant costs and benefits resulting from the establishment of μG and μGrid are identified and a methodology for sharing those costs and benefits among the involved economic agents is presented. The only pre-requisite of such a methodology is the existence of a net benefit to all economic agents.
Resumo:
In recent years, the 380V DC and 48V DC distribution systems have been extensively studied for the latest data centers. It is widely believed that the 380V DC system is a very promising candidate because of its lower cable cost compared to the 48V DC system. However, previous studies have not adequately addressed the low reliability issue with the 380V DC systems due to large amount of series connected batteries. In this thesis, a quantitative comparison for the two systems has been presented in terms of efficiency, reliability and cost. A new multi-port DC UPS with both high voltage output and low voltage output is proposed. When utility ac is available, it delivers power to the load through its high voltage output and charges the battery through its low voltage output. When utility ac is off, it boosts the low battery voltage and delivers power to the load form the battery. Thus, the advantages of both systems are combined and the disadvantages of them are avoided. High efficiency is also achieved as only one converter is working in either situation. Details about the design and analysis of the new UPS are presented. For the main AC-DC part of the new UPS, a novel bridgeless three-level single-stage AC-DC converter is proposed. It eliminates the auxiliary circuit for balancing the capacitor voltages and the two bridge rectifier diodes in previous topology. Zero voltage switching, high power factor, and low component stresses are achieved with this topology. Compared to previous topologies, the proposed converter has a lower cost, higher reliability, and higher efficiency. The steady state operation of the converter is analyzed and a decoupled model is proposed for the converter. For the battery side converter as a part of the new UPS, a ZVS bidirectional DC-DC converter based on self-sustained oscillation control is proposed. Frequency control is used to ensure the ZVS operation of all four switches and phase shift control is employed to regulate the converter output power. Detailed analysis of the steady state operation and design of the converter are presented. Theoretical, simulation, and experimental results are presented to verify the effectiveness of the proposed concepts.
Resumo:
Este trabalho tem como objetivo identificar a influência atmosférica em escala sinótica sobre o oceano, para eventos extremos de maré meteorológica na costa sudeste brasileira. Para isso foram utilizados dados de elevação do nível do mar do Porto de Santos-SP, campos de vento e pressão em superfície das reanálises do modelo do NCEP abrangendo o Atlântico Sul, no período de 1951 a 1990. Foi possível identificar a variabilidade sazonal e o padrão de evolução dos sistemas atmosféricos associados aos eventos extremos, de grande relevância para aplicações em prognósticos e alertas a autoridades. O outono e inverno apresentaram a maior ocorrência de extremos positivos (40,2 % e 30,8 % respectivamente), enquanto a primavera e o inverno foram as estações com maior número de extremos negativos (47,2 % e 32,3 % respectivamente). Os resultados mostram que os casos mais importantes de sobre-elevação do nível do mar ocorrem com a evolução e persistência de sistemas de baixa pressão sobre o oceano, com ventos de sudoeste acima de 8 m/s, juntamente com o anticiclone da retaguarda posicionado sobre o continente.
Resumo:
Bounds on the exchange-correlation energy of many-electron systems are derived and tested. By using universal scaling properties of the electron-electron interaction, we obtain the exponent of the bounds in three, two, one, and quasione dimensions. From the properties of the electron gas in the dilute regime, the tightest estimate to date is given for the numerical prefactor of the bound, which is crucial in practical applications. Numerical tests on various low-dimensional systems are in line with the bounds obtained and give evidence of an interesting dimensional crossover between two and one dimensions.
Resumo:
We review recent developments in manifold components and the introduction of light-emitting-diode technology in spectroscopic detection in order to evaluate the tremendous possibilities offered by multi-commutation for infield and in-situ measurements, based on the use of multi-pumping and low-voltage, portable batteries, which make possible a dramatic reduction in size, weight and power requirements of spectrometric devices. (C) 2009 Elsevier Ltd. All rights reserved.
Resumo:
In this work the performance of graded-channel (CC) SOI MOSFETs operating as source-follower buffers is presented. The experimental analysis is performed by comparing the gain and linearity of buffers implemented with CC and standard SOI MOS devices considering the same mask dimensions. It is shown that by using CC devices, buffer gain very close to the theoretical limit can be achieved, with improved linearity, while for standard devices the gain departs from the theoretical value depending on the inversion level imposed by the bias current and input voltage. Two-dimensional numerical simulations were performed in order to confirm some hypotheses proposed to explain the gain behavior observed in the experimental data. By using numerical simulations the channel length has been varied, showing that the gain of buffers implemented with CC devices remains close to the theoretical limit even when short-channel devices are adopted. It has also been shown that the length of a source-follower buffer using CC devices can be reduced by a factor of 5, in comparison with a standard Sol MOSFET, without gain loss or linearity degradation. (C) 2008 Elsevier Ltd. All rights reserved.
Resumo:
In this work we present an analysis of harmonic distortion (HD) in graded-channel (GC) gate-all-a round (GAA) devices operating in saturation region for analog applications. The study has been performed through device characterization and two-dimensional process and device simulations. The overall study has been done on the total and third order HDs. When applied in the saturation regime as an amplifier, the GC outperforms conventional GAA transistors presenting simultaneously higher transconductance, lower drain output conductance and more than 15 dB improved linearity. The influence of channel length reduction on the H D is also analyzed. Although slight linearity degradation is observed in both the conventional and the GC devices when reducing the channel length, the HD presented by the GC transistor is significantly lower than the one showed by conventional device for any Studied channel length. This allows AC input signal amplitude up to 20 times higher than the conventional GAA for a same specified distortion level. (C) 2008 Elsevier Ltd. All rights reserved.
Resumo:
This study aims to review the experience, at an institution, with patients who suffered electrical burns and study the peculiar characteristics of this type of burn as well as its complications and epidemiological aspects. The study includes medical records of patients with electrical burns who were admitted to the Burn Unit of Hospital das Clinicas in Sao Paulo, Brazil, from November 2001 to October 2006. They were classified into four categories: high voltage (>= 1000 V), low voltage (<1000 V), `flash burn` (in which there is no electrical current flow through the body of the patient) and burns caused by lightning. The complications were more severe and common in the high-voltage group, while longer hospital stays and more complex surgical procedures due to the greater depth of burns were also observed in this group. High-voltage burns are mainly labour-/occupation-related. The majority of the patients were young men at the beginning of their professional lives. This factor generates an important socio-economic impact due to the high incidence of sequelae, resulting in amputations, rendering them unable to maintain their occupations. (C) 2009 Elsevier Ltd and ISBI. All rights reserved.
Resumo:
Backtrack simulation analysis indicates that wind-blown mosquitoes could have traveled from New Guinea to Australia, potentially introducing Japanese encephalitis virus. Large incursions of the virus in 1995 and 1998 were linked with low-pressure systems that sustained strong northerly winds from New Guinea to the Cape York Peninsula.
Resumo:
Associado à escassez dos combustíveis fósseis e ao desejado controlo de emissões nocivas para a atmosfera, assistimos no mundo ao desenvolvimento do um novo paradigma — a mobilidade eléctrica. Apesar das variações de maior ou menor arbítrio político dos governos, do excelente ou débil desenvolvimento tecnológico, relacionados com os veículos eléctricos, estamos perante um caminho, no que diz respeito à mobilidade eléctrica, que já não deve ser encarado como uma moda mas como uma orientação para o futuro da mobilidade. Portugal tendo dado mostras que pretende estar na dianteira deste desafio, necessita equacionar e compreender em que condições existirá uma infra-estrutura nacional capaz de fazer o veículo eléctrico vingar. Assim, neste trabalho, analisa-se o impacto da mobilidade eléctrica em algumas dessas infra-estruturas, nomeadamente nos edifícios multi-habitacionais e redes de distribuição em baixa tensão. São criados neste âmbito, quatro perfis de carregamento dos EVs nomeadamente: nas horas de chegada a casa; nas horas de vazio com início programado pelo condutor; nas horas de vazio controlado por operador de rede (“Smart Grid”); e um cenário que contempla a utilização do V2G. Com a obrigação legal de nos novos edifícios serem instaladas tomadas para veículos eléctricos, é estudado, com os cenários anteriores a possibilidade de continuar a conceber as instalações eléctricas, sem alterar algumas das disposições legais, ao abrigo dos regulamentos existentes. É também estudado, com os cenários criados e com a previsão da venda de veículos eléctricos até 2020, o impacto deste novo consumo no diagrama de carga do Sistema Eléctrico Nacional. Mostra-se assim que a introdução de sistemas inteligentes de distribuição de energia [Smartgrid e vehicle to grid” (V2G)] deverá ser encarada como a solução que por excelência contribuirá para um aproveitamento das infra-estruturas existentes e simultaneamente um uso acessível para os veículos eléctricos.
Resumo:
As tecnologias de rádio sobre fibra associam as comunicações rádio com as comunicações ópticas, sendo estas os dois tipos de comunicações com maior desenvolvimento nos últimos anos, ao permitirem débitos e larguras de banda elevadas e simultaneamente uma elevada mobilidade. Neste sentido, no mercado das telecomunicações têm sido desenvolvidos sistemas com alta performance, tentando reduzir o quanto possível os custos associados aos sistemas, tendo assim uma especial relevância os designados sistemas de baixo custo. Nesta dissertação de Mestrado estuda-se a propagação de sinais rádio sobre fibra, variando o tipo de modulação óptica utilizada e tendo como base os sistemas de baixo custo. Estes sistemas de baixo custo são sistemas que utilizam apenas uma fonte óptica para o sentido descendente, remodulando a portadora na estação remota com o sinal do sentido ascendente. Começa-se por fazer um estudo sobre o estado da arte da tecnologia rádio sobre fibra e tecnologias envolvidas. De seguida, é apresentado um estudo teórico sobre o sistema rádio sobre fibra, desde a sua arquitectura, figuras de mérito e seus componentes. Posteriormente, são apresentadas as modulações ópticas utilizadas em sistemas rádio sobre fibra. A avaliação dos sistemas e apresentação de resultados é efectuada recorrendo a simulações. De acordo com os resultados obtidos pode verificar-se que a utilização de modulação de fase no sentido descendente e modulação de intensidade no sentido ascendente é a solução que melhores resultados apresenta como sistema de baixo custo. No entanto, caso se pretenda uma melhor performance em detrimento da redução de custos, deve-se optar por um sistema convencional com duas fontes ópticas, uma para cada sentido.
Resumo:
In smart grids context, the distributed generation units based in renewable resources, play an important rule. The photovoltaic solar units are a technology in evolution and their prices decrease significantly in recent years due to the high penetration of this technology in the low voltage and medium voltage networks supported by governmental policies and incentives. This paper proposes a methodology to determine the maximum penetration of photovoltaic units in a distribution network. The paper presents a case study, with four different scenarios, that considers a 32-bus medium voltage distribution network and the inclusion storage units.
Resumo:
Dissertação de Mestrado, Ciências Económicas e Empresariais, 16 de Janeiro 2014, Universidade dos Açores.
Resumo:
Mestrado em Engenharia Electrotécnica e de Computadores