988 resultados para label-free quantification


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Tramadol is a well tolerated and effective analgesic used to treat moderate to severe pain. Several generic formulations of tramadol are available in Brazil; however, published information regarding their bioequivalence in the Brazilian population is not available. A study was designed for Brazilian regulatory authorities to allow marketing of a generic formulation. Objective: The purpose of this study was to compare the bioequivalence of 2 commercial tablet preparations containing tramadol 100 mg marketed for use in Brazil. Methods: A randomized, open-label, 2 x 2 crossover study was performed in healthy Brazilian volunteers under fasting conditions with a washout period of 12 days. Two tablet formulations of tramadol 100 mg (test and reference formulations) were administered as a single oral dose, and blood samples were collected over 24 hours. Tramadol plasma concentrations were quantified using a validated HPLC method. A plasma concentration time profile was generated for each volunteer and then mean values were determined, from which C(max), T(max), AUC(0-t), AUC(0-infinity), k(e), and t(1/2) were calculated using a noncompartmental model. Bioequivalence between the products was determined by calculating 90% CIs for the ratios of C(max), AUC(0-t), and AUC(0-infinity) values for the test and reference products using log-transformed data. Tolerability was assessed by monitoring vital signs (temperature, blood pressure, heart rate), laboratory tests (hematology, blood biochemistry, hepatic function, urinalysis), and interviews with the volunteers before medication administration and every 2 hours during the study. Results: Twenty-six healthy volunteers (13 men, 13 women) were enrolled in and completed the study. Mean (SD) age was 30 (6.8) years (range, 21-44 years), mean weight was 64 (8.3) kg (range, 53-79 kg), and mean height was 166 (6.4) cm (range, 155-178 cm). The 90% CIs for the ratios of C(max) (1.01-1.17), AUC(0-t) (1.00-1.13), and AUC(0-infinity) (1.00-1.14) values for the test and reference products fell within the interval of 0.80 to 1.25 proposed by most regulatory agencies, including the Brazilian regulatory body. No clinically important adverse effects were reported; only mild somnolence was reported by 4 volunteers and mild headaches by 5 volunteers, and there was no need to use medication to treat these symptoms. Conclusion: Pharmacokinetic analysis in these healthy Brazilian volunteers suggested that the test and reference formulations of tramadol 100-mg tablets met the regulatory requirements to assume bio-equivalence based on the Brazilian regulatory definition. (Clin Ther 2010;32:758-765) (C) 2010 Excerpta Medica Inc.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Color Doppler myocardial imaging (CDMI) allows the calculation of local longitudinal or radial strain rate (SR) and strain (epsilon). The aims of this study were to determine the feasibility and reproducibility of longitudinal and radial SR and epsilon in neonates during the first hours of life and to establish reference values. Methods: Data were obtained from 55 healthy neonates (29 male; mean age, 20 +/- 14 hours; mean birth weight, 3,174 +/- 374 g). Apical and parasternal views quantified regional longitudinal and radial SR and epsilon in differing ventricular wall segments. Values at peak systole, early diastole, and late diastole were calculated from the extracted curves. CDMI data acquired at 300 +/- 50 frames/s were analyzed offline. Three consecutive cardiac cycles were measured during normal respiration. The timing of specific systolic or diastolic regional events was determined. Multiple comparisons between walls and segments were made. Results: Left ventricular (LV) longitudinal deformation showed basal differences compared with apical segments within one specific wall. Right ventricular (RV) longitudinal deformation was not homogeneous, with significant differences between basal and apical segments. Longitudinal 3 values were higher in the RV free basal and middle wall segments compared with the left ventricle. In the RV free wall apical segment, longitudinal SR and 3 were maximal. LV systolic SR and epsilon values were higher radially compared with longitudinally (radial peak systolic SR midportion, 2.9 +/- 0.6 s(-1); radial peak systolic epsilon 53.8 +/- 19%; longitudinal peak systolic SR midportion, -1.8 +/- 0.5 s(-1); longitudinal peak systolic epsilon, -24.8 +/- 3%; P < .01). Longitudinal systolic epsilon and SR interobserver variability values were 1.2% and 0.7%, respectively. Conclusion: Ultrasound-based SR and 3 imaging is a practical and reproducible clinical technique in neonates, allowing the calculation of regional longitudinal and radial deformation in RV and LV segments. These regional SR and epsilon indices represent new, noninvasive parameters that can quantify normal neonate regional cardiac function. Independent from visual interpretation, they can be used as reference values for diagnosis in ill neonates. (J Am Soc Echocardiogr 2009;22:369-375.)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The main objective of this experiment is to determine the amount of nicotine in commercial brand cigarettes by means of a nonaqueous acid-base titration. A simple glass device simulating a smoker is proposed, which allows the determination of the volatilized, filter retained, and inhaled portions. Students will readily see that the amount of nicotine/cigarette stated on the label (similar to 0.5-1.0 mg) refers indeed to the inhaled portion only, rather than to the total amount/cigarette (usually more than 10 mg). Even so, values for inhaled nicotine may be significantly higher than those reported for several brands. Students will also be able to make a critical evaluation of the true content of nicotine in the inhaled portion and confront it with the reported value for a given brand. In addition, the theoretical approach, supported by HPLC data, provides an excellent experience on nonaqueous acid-base volumetric analysis.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Two chromatographic methods, gas chromatography with flow ionization detection (GC–FID) and liquid chromatography with ultraviolet detection (LC–UV), were used to determine furfuryl alcohol in several kinds of foundry resins, after application of an optimised extraction procedure. The GC method developed gave feasibility that did not depend on resin kind. Analysis by LC was suitable just for furanic resins. The presence of interference in the phenolic resins did not allow an appropriate quantification by LC. Both methods gave accurate and precise results. Recoveries were >94%; relative standard deviations were ≤7 and ≤0.3%, respectively for GC and LC methods. Good relative deviations between the two methods were found (≤3%).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Formaldehyde is a toxic component that is present in foundry resins. Its quantification is important to the characterisation of the resin (kind and degradation) as well as for the evaluation of free contaminants present in wastes generated by the foundry industry. The complexity of the matrices considered suggests the need for separative techniques. The method developed for the identification and quantification of formaldehyde in foundry resins is based on the determination of free carbonyl compounds by derivatization with 2,4-dinitrophenylhydrazine (DNPH), being adapted to the considered matrices using liquid chromatography (LC) with UV detection. Formaldehyde determinations in several foundry resins gave precise results. Mean recovery and R.S.D. were, respectively, >95 and 5%. Analyses by the hydroxylamine reference method gave comparable results. Results showed that hydroxylamine reference method is applicable just for a specific kind of resin, while the developed method has good performance for all studied resins.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Phenol is a toxic compound present in a wide variety of foundry resins. Its quantification is important for the characterization of the resins as well as for the evaluation of free contaminants present in foundry wastes. Two chromatographic methods, liquid chromatography with ultraviolet detection (LC-UV) and gas chromatography with flame ionization detection (GC-FID), for the analysis of free phenol in several foundry resins, after a simple extraction procedure (30 min), were developed. Both chromatographic methods were suitable for the determination of phenol in the studied furanic and phenolic resins, showing good selectivity, accuracy (recovery 99–100%; relative deviations <5%), and precision (coefficients of variation <6%). The used ASTM reference method was only found to be useful in the analysis of phenolic resins, while the LC and GC methods were applicable for all the studied resins. The developed methods reduce the time of analysis from 3.5 hours to about 30 min and can readily be used in routine quality control laboratories.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Amulti-residue methodology based on a solid phase extraction followed by gas chromatography–tandem mass spectrometry was developed for trace analysis of 32 compounds in water matrices, including estrogens and several pesticides from different chemical families, some of them with endocrine disrupting properties. Matrix standard calibration solutions were prepared by adding known amounts of the analytes to a residue-free sample to compensate matrix-induced chromatographic response enhancement observed for certain pesticides. Validation was done mainly according to the International Conference on Harmonisation recommendations, as well as some European and American validation guidelines with specifications for pesticides analysis and/or GC–MS methodology. As the assumption of homoscedasticity was not met for analytical data, weighted least squares linear regression procedure was applied as a simple and effective way to counteract the greater influence of the greater concentrations on the fitted regression line, improving accuracy at the lower end of the calibration curve. The method was considered validated for 31 compounds after consistent evaluation of the key analytical parameters: specificity, linearity, limit of detection and quantification, range, precision, accuracy, extraction efficiency, stability and robustness.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The number of physical activity measures and indexes used in the human literature is large and may result in some difficulty for the average investigator to choose the most appropriate measure. Accordingly, this review is intended to provide information on the utility and limitations of the various measures. Its primary focus is the objective assessment of free-living physical activity in humans based on physiological and biomechanical methods. The physical activity measures have been classified into three categories: Measures based on energy expenditure or oxygen uptake, such as activity energy expenditure, activity-related time equivalent, physical activity level, physical activity ratio, metabolic equivalent, and a new index of potential interest, daytime physical activity level. Measures based on heart rate monitoring, such as net heart rate, physical activity ratio heart rate, physical activity level heart rate, activity-related time equivalent, and daytime physical activity level heart rate. Measures based on whole-body accelerometry (counts/U time). Quantification of the velocity and duration of displacement in outdoor conditions by satellites using the Differential Global Positioning System may constitute a surrogate for physical activity, because walking is the primary activity of man in free-living conditions. A general outline of the measures and indexes described above is presented in tabular form, along with their respective definition, usual applications, advantages, and shortcomings. A practical example is given with typical values in obese and non-obese subjects. The various factors to be considered in the selection of physical activity methods include experimental goals, sample size, budget, cultural and social/environmental factors, physical burden for the subject, and statistical factors, such as accuracy and precision. It is concluded that no single current technique is able to quantify all aspects of physical activity under free-living conditions, requiring the use of complementary methods. In the future, physical activity sensors, which are of low-cost, small-sized, and convenient for subjects, investigators, and clinicians, are needed to reliably monitor, during extended periods in free-living situations, small changes in movements and grade as well as duration and intensity of typical physical activities.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVES: This study sought to establish an accurate and reproducible T(2)-mapping cardiac magnetic resonance (CMR) methodology at 3 T and to evaluate it in healthy volunteers and patients with myocardial infarct. BACKGROUND: Myocardial edema affects the T(2) relaxation time on CMR. Therefore, T(2)-mapping has been established to characterize edema at 1.5 T. A 3 T implementation designed for longitudinal studies and aimed at guiding and monitoring therapy remains to be implemented, thoroughly characterized, and evaluated in vivo. METHODS: A free-breathing navigator-gated radial CMR pulse sequence with an adiabatic T(2) preparation module and an empirical fitting equation for T(2) quantification was optimized using numerical simulations and was validated at 3 T in a phantom study. Its reproducibility for myocardial T(2) quantification was then ascertained in healthy volunteers and improved using an external reference phantom with known T(2). In a small cohort of patients with established myocardial infarction, the local T(2) value and extent of the edematous region were determined and compared with conventional T(2)-weighted CMR and x-ray coronary angiography, where available. RESULTS: The numerical simulations and phantom study demonstrated that the empirical fitting equation is significantly more accurate for T(2) quantification than that for the more conventional exponential decay. The volunteer study consistently demonstrated a reproducibility error as low as 2 ± 1% using the external reference phantom and an average myocardial T(2) of 38.5 ± 4.5 ms. Intraobserver and interobserver variability in the volunteers were -0.04 ± 0.89 ms (p = 0.86) and -0.23 ± 0.91 ms (p = 0.87), respectively. In the infarction patients, the T(2) in edema was 62.4 ± 9.2 ms and was consistent with the x-ray angiographic findings. Simultaneously, the extent of the edematous region by T(2)-mapping correlated well with that from the T(2)-weighted images (r = 0.91). CONCLUSIONS: The new, well-characterized 3 T methodology enables robust and accurate cardiac T(2)-mapping at 3 T with high spatial resolution, while the addition of a reference phantom improves reproducibility. This technique may be well suited for longitudinal studies in patients with suspected or established heart disease.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fecal incontinence (FI) is the involuntary loss of rectal contents through the anal canal. Reports of its prevalence vary from 1-21%. Studies, have demonstrated a positive effect on FI symptoms with injectable bulking agents. This study evaluated the safety and efficacy of NASHA/Dx gel in the treatment of FI. One hundred fifteen eligible patients suffering from FI received 4 injections of 1 mL NASHA/Dx gel. Primary efficacy was based on data from 86 patients that completed the study. This study demonstrated a ≥50% reduction from baseline in the number of FI episodes in 57.1% of patients at 6 months, and 64.0% at 12 months. Significant improvements (P < .001) were also noted in total number of both solid and loose FI episodes, FI free days, CCFIS, and FIQL scores in all 4 domains. The majority of the treatment related AEs (94.9%) were mild or moderate intensity, and (98.7%) of AEs resolved spontaneously, or following treatment, without sequelae. Results of this study indicate NASHA/Dx gel was efficacious in the treatment of FI. Treatment effect was significant both in reduction of number of FI episodes and disease specific quality of life at 6 months and lasted up to 12 months after treatment.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND Phase-IV, open-label, single-arm study (NCT01203917) to assess efficacy and safety/tolerability of first-line gefitinib in Caucasian patients with stage IIIA/B/IV, epidermal growth factor receptor (EGFR) mutation-positive non-small-cell lung cancer (NSCLC). METHODS Treatment: gefitinib 250 mg day(-1) until progression. Primary endpoint: objective response rate (ORR). Secondary endpoints: disease control rate (DCR), progression-free survival (PFS), overall survival (OS) and safety/tolerability. Pre-planned exploratory objective: EGFR mutation analysis in matched tumour and plasma samples. RESULTS Of 1060 screened patients with NSCLC (859 known mutation status; 118 positive, mutation frequency 14%), 106 with EGFR sensitising mutations were enrolled (female 70.8%; adenocarcinoma 97.2%; never-smoker 64.2%). At data cutoff: ORR 69.8% (95% confidence interval (CI) 60.5-77.7), DCR 90.6% (95% CI 83.5-94.8), median PFS 9.7 months (95% CI 8.5-11.0), median OS 19.2 months (95% CI 17.0-NC; 27% maturity). Most common adverse events (AEs; any grade): rash (44.9%), diarrhoea (30.8%); CTC (Common Toxicity Criteria) grade 3/4 AEs: 15%; SAEs: 19%. Baseline plasma 1 samples were available in 803 patients (784 known mutation status; 82 positive; mutation frequency 10%). Plasma 1 EGFR mutation test sensitivity: 65.7% (95% CI 55.8-74.7). CONCLUSION First-line gefitinib was effective and well tolerated in Caucasian patients with EGFR mutation-positive NSCLC. Plasma samples could be considered for mutation analysis if tumour tissue is unavailable.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Phase-IV, open-label, single-arm study (NCT01203917) to assess efficacy and safety/tolerability of first-line gefitinib in Caucasian patients with stage IIIA/B/IV, epidermal growth factor receptor (EGFR) mutation-positive non-small-cell lung cancer (NSCLC). METHODS: TREATMENT: gefitinib 250 mg day(-1) until progression. Primary endpoint: objective response rate (ORR). Secondary endpoints: disease control rate (DCR), progression-free survival (PFS), overall survival (OS) and safety/tolerability. Pre-planned exploratory objective: EGFR mutation analysis in matched tumour and plasma samples. RESULTS: Of 1060 screened patients with NSCLC (859 known mutation status; 118 positive, mutation frequency 14%), 106 with EGFR sensitising mutations were enrolled (female 70.8%; adenocarcinoma 97.2%; never-smoker 64.2%). At data cutoff: ORR 69.8% (95% confidence interval (CI) 60.5-77.7), DCR 90.6% (95% CI 83.5-94.8), median PFS 9.7 months (95% CI 8.5-11.0), median OS 19.2 months (95% CI 17.0-NC; 27% maturity). Most common adverse events (AEs; any grade): rash (44.9%), diarrhoea (30.8%); CTC (Common Toxicity Criteria) grade 3/4 AEs: 15%; SAEs: 19%. Baseline plasma 1 samples were available in 803 patients (784 known mutation status; 82 positive; mutation frequency 10%). Plasma 1 EGFR mutation test sensitivity: 65.7% (95% CI 55.8-74.7). CONCLUSION: First-line gefitinib was effective and well tolerated in Caucasian patients with EGFR mutation-positive NSCLC. Plasma samples could be considered for mutation analysis if tumour tissue is unavailable.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Rb-82cardiac PET has been used to non-invasively assess myocardial blood flow (MBF)and myocardial flow reserve (MFR). The impact of MBF and MFR for predictingmajor adverse cardiovascular events (MACE) has not been investigated in aprospective study, which was our aim. MATERIAL AND METHODS: In total, 280patients (65±10y, 36% women) with known or suspected CAD were prospectivelyenrolled. They all underwent both a rest and adenosine stress Rb-82 cardiacPET/CT. Dynamic acquisitions were processed with the FlowQuant 2.1.3 softwareand analyzed semi-quantitatively (SSS, SDS) and quantitatively (MBF, MFR) andreported using the 17-segment AHA model. Patients were stratified based on SDS,stress MBF and MFR and allocated into tertiles. For each group, annualizedevent rates were computed by dividing the number of annualized MACE (cardiacdeath, myocardial infarction, revascularisation or hospitalisation forcardiac-related event) by the sum of individual follow-up periods in years.Outcome were analysed for each group using Kaplan-Meier event-free survivalcurves and compared using the log-rank test. Multivariate analysis wasperformed in a stepwise fashion using Cox proportional hazards regressionmodels (p<0.05 for model inclusion). RESULTS: In a median follow-up of 256days (range 168-440d), 44 MACE were observed. Ischemia (SDS≥2) was observed in95 patients who had higher annualized MACE rate as compared to those without(55% vs. 9.8%, p<0.0001). The group with the lowest MFR tertile (MFR<1.76)had higher MACE rate than the two highest tertiles (51% vs. 9% and 14%,p<0.0001). Similarly, the group with the lowest stress MBF tertile(MBF<1.78mL/min/g) had the highest annualized MACE rate (41% vs. 26% and 6%,p=0.0002). On multivariate analysis, the addition of MFR or stress MBF to SDSsignificantly increased the global χ2 (from 56 to 60, p=0.04; and from56 to 63, p=0.01). The best prognostic power was obtained in a model combiningSDS (p<0.001) and stress MBF (p=0.01). Interestingly, the integration ofstress MBF enhanced risk stratification even in absence of ischemia.CONCLUSIONS: Quantification of MBF or MFR in Rb-82 cardiac PET/CT providesindependent and incremental prognostic information over semi-quantitativeassessment with SDS and is of value for risk stratification.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND & AIM: Brain metastases are frequent in patients with metastatic melanoma, indicating poor prognosis. We investigated the BRAF kinase inhibitor vemurafenib in patients with advanced melanoma with symptomatic brain metastases. METHODS: This open-label trial assessed vemurafenib (960mg twice a day) in patients with BRAF(V600) mutation-positive metastatic melanoma with non-resectable, previously treated brain metastases. The primary end-point was safety. Secondary end-points included best overall response rate, and progression-free and overall survival. RESULTS: Twenty-four patients received vemurafenib for a median treatment duration of 3.8 (0.1-11.3) months. The majority of discontinuations were due to disease progression (n=22). Twenty-three of 24 patients reported at least one adverse event (AE). Grade 3 AEs were reported in four (17%; 95% confidence interval [CI], 4.7-37.4%) patients and included cutaneous squamous cell carcinoma in four patients. Median progression-free survival was 3.9 (95% CI, 3.0-5.5) months, and median survival was 5.3 (95% CI, 3.9-6.6) months. An overall partial response (PR) at both intracranial and extracranial sites was achieved in 10 of 24 (42%; 95% CI, 22.1-63.4) evaluable patients, with stable disease in nine (38%; 95% CI, 18.8-59.4) patients. Of 19 patients with measurable intracranial disease, seven (37%) achieved >30% intracranial tumour regression, and three (16%; 95% CI, 3.4-39.6%) achieved a confirmed PR. Other signs of improvement included reduced need for corticosteroids and enhanced performance status. CONCLUSIONS: Vemurafenib can be safely used in patients with advanced symptomatic melanoma that has metastasised to the brain and can result in meaningful tumour regression.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The only currently available method to measure brain glycogen in vivo is 13C NMR spectroscopy. Incorporation of 13C-labeled glucose (Glc) is necessary to allow glycogen measurement, but might be affected by turnover changes. Our aim was to measure glycogen absolute concentration in the rat brain by eliminating label turnover as variable. The approach is based on establishing an increased, constant 13C isotopic enrichment (IE). 13C-Glc infusion is then performed at the IE of brain glycogen. As glycogen IE cannot be assessed in vivo, we validated that it can be inferred from that of N-acetyl-aspartate IE in vivo: After [1-13C]-Glc ingestion, glycogen IE was 2.2 +/- 0.1 fold that of N-acetyl-aspartate (n = 11, R(2) = 0.77). After subsequent Glc infusion, glycogen IE equaled brain Glc IE (n = 6, paired t-test, p = 0.37), implying isotopic steady-state achievement and complete turnover of the glycogen molecule. Glycogen concentration measured in vivo by 13C NMR (mean +/- SD: 5.8 +/- 0.7 micromol/g) was in excellent agreement with that in vitro (6.4 +/- 0.6 micromol/g, n = 5). When insulin was administered, the stability of glycogen concentration was analogous to previous biochemical measurements implying that glycogen turnover is activated by insulin. We conclude that the entire glycogen molecule is turned over and that insulin activates glycogen turnover.