Chromatographic techniques for the determination of free phenol in foundry resins


Autoria(s): Oliva-Teles, Maria Teresa; Delerue-Matos, Cristina; Nouws, Henri P. A.; Alvim-Ferraz, Maria da Conceição M.
Data(s)

27/11/2013

27/11/2013

2011

Resumo

Phenol is a toxic compound present in a wide variety of foundry resins. Its quantification is important for the characterization of the resins as well as for the evaluation of free contaminants present in foundry wastes. Two chromatographic methods, liquid chromatography with ultraviolet detection (LC-UV) and gas chromatography with flame ionization detection (GC-FID), for the analysis of free phenol in several foundry resins, after a simple extraction procedure (30 min), were developed. Both chromatographic methods were suitable for the determination of phenol in the studied furanic and phenolic resins, showing good selectivity, accuracy (recovery 99–100%; relative deviations <5%), and precision (coefficients of variation <6%). The used ASTM reference method was only found to be useful in the analysis of phenolic resins, while the LC and GC methods were applicable for all the studied resins. The developed methods reduce the time of analysis from 3.5 hours to about 30 min and can readily be used in routine quality control laboratories.

Identificador

DOI: 10.1080/00032719.2010.520383

0003-2719

1532-236X

http://hdl.handle.net/10400.22/3009

Idioma(s)

eng

Publicador

Taylor & Francis

Relação

Analytical Letters; Vol. 44, Issue 8

http://www.tandfonline.com/doi/abs/10.1080/00032719.2010.520383#.UpYgCydqyZR

Direitos

openAccess

Palavras-Chave #Foundry resin #Gas chromatography #Liquid chromatography #Phenol