979 resultados para flow-volume curve


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Blood flow in human aorta is an unsteady and complex phenomenon. The complex patterns are related to the geometrical features like curvature, bends, and branching and pulsatile nature of flow from left ventricle of heart. The aim of this work was to understand the effect of aorta geometry on the flow dynamics. To achieve this, 3D realistic and idealized models of descending aorta were reconstructed from Computed Tomography (CT) images of a female patient. The geometries were reconstructed using medical image processing code. The blood flow in aorta was assumed to be laminar and incompressible and the blood was assumed to be Newtonian fluid. A time dependent pulsatile and parabolic boundary condition was deployed at inlet. Steady and unsteady blood flow simulations were performed in real and idealized geometries of descending aorta using a Finite Volume Method (FVM) code. Analysis of Wall Shear Stress (WSS) distribution, pressure distribution, and axial velocity profiles were carried out in both geometries at steady and unsteady state conditions. The results obtained in thesis work reveal that the idealization of geometry underestimates the values of WSS especially near the region with sudden change of diameter. However, the resultant pressure and velocity in idealized geometry are close to those in real geometry

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A spectrophotometric flow injection method for the determination of paracetamol in pharmaceutical formulations is proposed. The procedure was based on the oxidation of paracetamol by sodium hypochloride and the determination of the excess of this oxidant using o-tolidine dichloride as chromogenic reagent at 430 nm. The analytical curve was linear in the paracetamol concentration range from 8.50 x 10-6 to 2.51 x 10-4 mol L-1 with a detection limit of 5.0 x 10-6 mol L-1. The relative standard deviation was smaller than 1.2% for 1.20 x 10-4 mol L-1 paracetamol solution (n = 10). The results obtained for paracetamol in pharmaceutical formulations using the proposed flow injection method and those obtained using a USP Pharmacopoeia method are in agreement at the 95% confidence level.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A spectrophotometric flow injection method for the determination of Zn(II) in ophthalmic formulations was developed. In this work, Zn(II) ion was complexed with Alizarin red S in borate buffer solution (pH 9.0) and the chromophore produced was monitored at 520 nm. The analytical curve was linear in the Zn(II) concentration range from 6.05 x 10-6 to 1.50 x 10-4 mol L-1 with a detection limit of 3.60 x 10-6 mol L-1. Recoveries ranged from 96.3 to 105 % and a relative standard deviation of 1.2 % (n = 10) for 5.5x10-5 mol L-1 Zn(II) reference solution were obtained. The sampling rate was 60 h-1 and the results obtained of Zn(II) in ophthalmic products using this procedure are in close agreement with those obtained using a comparative spectrophotometric procedure at 95 % confidence level.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of the thesis is to analyze traffic flows and its development from North European companies` point of view to China and Russia using data from logistics questionnaire. Selected North European companies are large Finnish and Swedish companies. The questionnaire was sent via email to the target group. The study is based on the answers got from respondent companies from years 2006, 2009 and 2010. In the thesis Finnish Talouselämä newspaper and Swedish Affärsdata are used as a database to find the target companies for the survey. Respondents were most often logistics managers in companies. In the beginning of the thesis concepts of transportation logistics is presented, including container types, trade terms, axel loads in roads and in railways. Also there is information about warehousing types and terminals. After that, general information of Chinese and Russian transportation logistics is presented. Chinese and Russian issues are discussed in two sections. In both of them it is analyzed economic development, freight transport and trade balance. Some practical examples of factory inaugurations in China and Russia are presented that Finnish and Swedish companies have completed. In freight transport section different transportation modes, logistics outsourcing and problems of transportation logistics is discussed. The results of the thesis show that transportation flows between Europe and China is changing. Freight traffic from China to European countries will strengthen even more from the current base. When it comes to Russia and Europe, traffic flows seem to be changing from eastbound traffic to westbound traffic. It means that in the future it is expected more freight traffic from Russia to Europe. Some probable reasons for that are recent factory establishments in Russia and company interviews support also this observation. Effects of the economic recession are mainly seen in the lower transportation amounts in 2009.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this study was to simulate blood flow in thoracic human aorta and understand the role of flow dynamics in the initialization and localization of atherosclerotic plaque in human thoracic aorta. The blood flow dynamics in idealized and realistic models of human thoracic aorta were numerically simulated in three idealized and two realistic thoracic aorta models. The idealized models of thoracic aorta were reconstructed with measurements available from literature, and the realistic models of thoracic aorta were constructed by image processing Computed Tomographic (CT) images. The CT images were made available by South Karelia Central Hospital in Lappeenranta. The reconstruction of thoracic aorta consisted of operations, such as contrast adjustment, image segmentations, and 3D surface rendering. Additional design operations were performed to make the aorta model compatible for the numerical method based computer code. The image processing and design operations were performed with specialized medical image processing software. Pulsatile pressure and velocity boundary conditions were deployed as inlet boundary conditions. The blood flow was assumed homogeneous and incompressible. The blood was assumed to be a Newtonian fluid. The simulations with idealized models of thoracic aorta were carried out with Finite Element Method based computer code, while the simulations with realistic models of thoracic aorta were carried out with Finite Volume Method based computer code. Simulations were carried out for four cardiac cycles. The distribution of flow, pressure and Wall Shear Stress (WSS) observed during the fourth cardiac cycle were extensively analyzed. The aim of carrying out the simulations with idealized model was to get an estimate of flow dynamics in a realistic aorta model. The motive behind the choice of three aorta models with distinct features was to understand the dependence of flow dynamics on aorta anatomy. Highly disturbed and nonuniform distribution of velocity and WSS was observed in aortic arch, near brachiocephalic, left common artery, and left subclavian artery. On the other hand, the WSS profiles at the roots of branches show significant differences with geometry variation of aorta and branches. The comparison of instantaneous WSS profiles revealed that the model with straight branching arteries had relatively lower WSS compared to that in the aorta model with curved branches. In addition to this, significant differences were observed in the spatial and temporal profiles of WSS, flow, and pressure. The study with idealized model was extended to study blood flow in thoracic aorta under the effects of hypertension and hypotension. One of the idealized aorta models was modified along with the boundary conditions to mimic the thoracic aorta under the effects of hypertension and hypotension. The results of simulations with realistic models extracted from CT scans demonstrated more realistic flow dynamics than that in the idealized models. During systole, the velocity in ascending aorta was skewed towards the outer wall of aortic arch. The flow develops secondary flow patterns as it moves downstream towards aortic arch. Unlike idealized models, the distribution of flow was nonplanar and heavily guided by the artery anatomy. Flow cavitation was observed in the aorta model which was imaged giving longer branches. This could not be properly observed in the model with imaging containing a shorter length for aortic branches. The flow circulation was also observed in the inner wall of the aortic arch. However, during the diastole, the flow profiles were almost flat and regular due the acceleration of flow at the inlet. The flow profiles were weakly turbulent during the flow reversal. The complex flow patterns caused a non-uniform distribution of WSS. High WSS was distributed at the junction of branches and aortic arch. Low WSS was distributed at the proximal part of the junction, while intermedium WSS was distributed in the distal part of the junction. The pulsatile nature of the inflow caused oscillating WSS at the branch entry region and inner curvature of aortic arch. Based on the WSS distribution in the realistic model, one of the aorta models was altered to induce artificial atherosclerotic plaque at the branch entry region and inner curvature of aortic arch. Atherosclerotic plaque causing 50% blockage of lumen was introduced in brachiocephalic artery, common carotid artery, left subclavian artery, and aortic arch. The aim of this part of the study was first to study the effect of stenosis on flow and WSS distribution, understand the effect of shape of atherosclerotic plaque on flow and WSS distribution, and finally to investigate the effect of lumen blockage severity on flow and WSS distributions. The results revealed that the distribution of WSS is significantly affected by plaque with mere 50% stenosis. The asymmetric shape of stenosis causes higher WSS in branching arteries than in the cases with symmetric plaque. The flow dynamics within thoracic aorta models has been extensively studied and reported here. The effects of pressure and arterial anatomy on the flow dynamic were investigated. The distribution of complex flow and WSS is correlated with the localization of atherosclerosis. With the available results we can conclude that the thoracic aorta, with complex anatomy is the most vulnerable artery for the localization and development of atherosclerosis. The flow dynamics and arterial anatomy play a role in the localization of atherosclerosis. The patient specific image based models can be used to diagnose the locations in the aorta vulnerable to the development of arterial diseases such as atherosclerosis.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The study aimed to determine an optimum angle for the nozzles axial-flow sprayers a deposition for better vertical distribution focused on cashew. In laboratory tests were conducted adjusting the angle of the nozzle axial-flow sprayers. The experimental design was randomized blocks in a 2x3 factorial with four replications. The treatment for this test were two settings (with and without the adjustment of the angles of the nozzles ) and tree application volumes 273, 699 and 954 L ha-¹.The study was conducted in an orchard of dwarf cashew, with eight years of age. It was concluded that the volumetric distribution profile showed better vertical distribution uniformity when the angles of the nozzles were regulated for the canopy, the adjustment of the angles of the nozzles for the canopy provided greater deposition of droplets, the increased volume of application resulted in higher depositions in the leaves of the crop.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

An unstructured grid Euler solver for reactive compressible flow applications is presented. The method is implemented in a cell centered, finite volume context for unstructured triangular grids. Three different schemes for spatial discretization are implemented and analyzed. Time march is implemented in a time-split fashion with independent integrators for the flow and chemistry equations. The capability implemented is tested for inert flows in a hypersonic inlet and for inert and reactive supersonic flows over a 2-D wedge. The results of the different schemes are compared with each other and with independent calculations using a structured grid code. The strengths and the possible weaknesses of the proposed methods are discussed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The work considers the modeling of turbulent flow in radial diffuser with axial feeding. Due to its claimed capability to predict flow including features such as separation, curvature and adverse pressure gradient, the RNG k-epsilon model of Orzag et al. (1993) is applied in the present analysis. The governing equations are numerically solved using the finite volume methodology. Experiments were conducted to assess the turbulence model. Numerical results of pressure distribution on the front disk surface for different flow conditions when compared to the experimental data indicated that the RNG k-epsilon model is adequate to predict this class of flow.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Mixed convection on the flow past a heated length and past a porous cavity located in a horizontal wall bounding a saturated porous medium is numerically simulated. The cavity is heated from below. The steady-state regime is studied for several intensities of the buoyancy effects due to temperature variations. The influences of Péclet and Rayleigh numbers on the flow pattern and the temperature distributions are examined. Local and global Nusselt numbers are reported for the heated surface. The convective-diffusive fluxes at the volume boundaries are represented using the UNIFAES, Unified Finite Approach Exponential-type Scheme, with the Power-Law approximation to reduce the computing time. The conditions established by Rivas for the quadratic order of accuracy of the central differencing to be maintained in irregular grids are shown to be extensible to other quadratic schemes, including UNIFAES, so that accuracy estimates could be obtained.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Systemic blood flow (Q) was measured by echodopplercardiography in 5 normal young adult males during apnea, eupnea and tachypnea. Measurements were made in a recumbent posture at 3-min intervals. Tachypnea was attained by doubling the respiratory frequency at eupnea at a constant tidal volume. An open glottis was maintained during apnea at the resting respiratory level. The Q values were positively correlated with the respiratory frequency, decreasing from eupnea to apnea and increasing from eupnea to tachypnea (P<0.05). These data demonstrate that echodopplercardiography, a better qualified tool for this purpose, confirms the positive and progressive effects of ventilation on systemic blood flow, as suggested by previous studies based on diverse technical approaches

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We have observed that acute blood volume expansion increases the gastroduodenal resistance to the flow of liquid in anesthetized dogs, while retraction decreases it (Santos et al. (1991) Acta Physiologica Scandinavica, 143: 261-269). This study evaluates the effect of blood volume expansion and retraction on the gastric emptying of liquid in awake rats using a modification of the technique of Scarpignato (1980) (Archives Internationales de Pharmacodynamie et de Therapie, 246: 286-294). Male Wistar rats (180-200 g) were fasted for 16 h with water ad libitum and 1.5 ml of the test meal (0.5 mg/ml phenol red solution in 5% glucose) was delivered to the stomach immediately after random submission to one of the following protocols: 1) normovolemic control (N = 22), 2) expansion (N = 72) by intravenous infusion (1 ml/min) of Ringer-bicarbonate solution, volumes of 1, 2, 3 or 5% body weight, or 3) retraction (N = 22) by controlled bleeding (1.5 ml/100 g). Gastric emptying of liquid was inhibited by 19-51.2% (P<0.05) after blood volume expansion (volumes of 1, 2, 3 or 5% body weight). Blood volume expansion produced a sustained increase in central venous pressure while mean arterial pressure was transiently increased during expansion (P<0.05). Blood volume retraction increased gastric emptying by 28.5-49.9% (P<0.05) and decreased central venous pressure and mean arterial pressure (P<0.05). Infusion of the shed blood 10 min after bleeding reversed the effect of retraction on gastric emptying. These findings suggest that gastric emptying of liquid is subject to modulation by the blood volume.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A pulsatile pressure-flow model was developed for in vitro quantitative color Doppler flow mapping studies of valvular regurgitation. The flow through the system was generated by a piston which was driven by stepper motors controlled by a computer. The piston was connected to acrylic chambers designed to simulate "ventricular" and "atrial" heart chambers. Inside the "ventricular" chamber, a prosthetic heart valve was placed at the inflow connection with the "atrial" chamber while another prosthetic valve was positioned at the outflow connection with flexible tubes, elastic balloons and a reservoir arranged to mimic the peripheral circulation. The flow model was filled with a 0.25% corn starch/water suspension to improve Doppler imaging. A continuous flow pump transferred the liquid from the peripheral reservoir to another one connected to the "atrial" chamber. The dimensions of the flow model were designed to permit adequate imaging by Doppler echocardiography. Acoustic windows allowed placement of transducers distal and perpendicular to the valves, so that the ultrasound beam could be positioned parallel to the valvular flow. Strain-gauge and electromagnetic transducers were used for measurements of pressure and flow in different segments of the system. The flow model was also designed to fit different sizes and types of prosthetic valves. This pulsatile flow model was able to generate pressure and flow in the physiological human range, with independent adjustment of pulse duration and rate as well as of stroke volume. This model mimics flow profiles observed in patients with regurgitant prosthetic valves.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The objective of this master’s thesis was to design and simulate a wind powered hydraulic heating system that can operate independently in remote places where the use of electricity is not possible. Components for the system were to be selected in such a way that the conditions for manufacture, use and economic viability are the as good as possible. Savonius rotor was chosen for wind turbine, due to its low cut in speed and robust design. Savonius rotor produces kinetic energy in wide wind speed range and it can withstand high wind gusts. Radial piston pump was chosen for the flow source of the hydraulic heater. Pump type was selected due to its characteristics in low rotation speeds and high efficiency. Volume flow from the pump is passed through the throttle orifice. Pressure drop over the orifice causes the hydraulic oil to heat up and, thus, creating thermal energy. Thermal energy in the oil is led to radiator where it conducts heat to the environment. The hydraulic heating system was simulated. For this purpose a mathematical models of chosen components were created. In simulation wind data gathered by Finnish meteorological institute for 167 hours was used as input. The highest produced power was achieved by changing the orifice diameter so that the rotor tip speed ratio follows the power curve. This is not possible to achieve without using electricity. Thus, for the orifice diameter only one, the optimal value was defined. Results from the simulation were compared with investment calculations. Different parameters effecting the investment profitability were altered in sensitivity analyses in order to define the points of investment profitability. Investment was found to be profitable only with high average wind speeds.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

During cardiopulmonary exercise testing (CPET), stroke volume can be indirectly assessed by O2 pulse profile. However, for a valid interpretation, the stability of this variable over time should be known. The objective was to analyze the stability of the O2 pulse curve relative to body mass in elite athletes. VO2, heart rate (HR), and relative O2 pulse were compared at every 10% of the running time in two maximal CPETs, from 2005 to 2010, of 49 soccer players. Maximal values of VO2 (63.4 ± 0.9 vs 63.5 ± 0.9 mL O2•kg-1•min-1), HR (190 ± 1 vs188 ± 1 bpm) and relative O2 pulse (32.9 ± 0.6 vs 32.6 ± 0.6 mL O2•beat-1•kg-1) were similar for the two CPETs (P > 0.05), while the final treadmill velocity increased from 18.5 ± 0.9 to 18.9 ± 1.0 km/h (P < 0.01). Relative O2 pulse increased linearly and similarly in both evaluations (r² = 0.64 and 0.63) up to 90% of the running time. Between 90 and 100% of the running time, the values were less stable, with up to 50% of the players showing a tendency to a plateau in the relative O2 pulse. In young healthy men in good to excellent aerobic condition, the morphology of the relative O2 pulse curve is consistent up to close to the peak effort for a CPET repeated within a 1-year period. No increase in relative O2pulse at peak effort could represent a physiologic stroke volume limitation in these athletes.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Polymyositis (PM) is an autoimmune disease characterized by chronic inflammation in skeletal muscle. Mean platelet volume (MPV), a marker in the assessment of systemic inflammation, is easily measured by automatic blood count equipment. However, to our knowledge, there are no data in the literature with respect to MPV levels in PM patients. Therefore, in this study we aimed to investigate MPV levels in patients with PM. This study included 92 newly diagnosed PM patients and 100 healthy individuals. MPV levels were found to be significantly lower compared with healthy controls (10.3±1.23 vs 11.5±0.74 fL, P<0.001). Interestingly, MPV was found to be positively correlated with manual muscle test (MMT) score and negatively correlated with erythrocyte sedimentation rate (ESR) in patients with PM (r=0.239, P=0.022; r=−0.268, P=0.010, respectively). In addition, MPV was significantly lower in active PM patients compared with inactive PM patients (9.9±1.39 vs 10.6±0.92 fL, P=0.010). MPV was independently associated with PM in multivariate regression analyses, when controlling for hemoglobin and ESR (OR=0.312, P=0.031, 95%CI=0.108 to 0.899). The ROC curve analysis for MPV in estimating PM patients resulted in an area under the curve of 0.800, with sensitivity of 75.0% and specificity of 67.4%. Our results suggest that MPV is inversely correlated with disease activity in patients with PM. MPV might be a useful tool for rapid assessment of disease severity in PM patients.