998 resultados para SPECTROPHOTOMETRIC DETERMINATION
Resumo:
A compiled set of in situ data is important to evaluate the quality of ocean-colour satellite-data records. Here we describe the data compiled for the validation of the ocean-colour products from the ESA Ocean Colour Climate Change Initiative (OC-CCI). The data were acquired from several sources (MOBY, BOUSSOLE, AERONET-OC, SeaBASS, NOMAD, MERMAID, AMT, ICES, HOT, GeP&CO), span between 1997 and 2012, and have a global distribution. Observations of the following variables were compiled: spectral remote-sensing reflectances, concentrations of chlorophyll a, spectral inherent optical properties and spectral diffuse attenuation coefficients. The data were from multi-project archives acquired via the open internet services or from individual projects, acquired directly from data providers. Methodologies were implemented for homogenisation, quality control and merging of all data. No changes were made to the original data, other than averaging of observations that were close in time and space, elimination of some points after quality control and conversion to a standard format. The final result is a merged table designed for validation of satellite-derived ocean-colour products and available in text format. Metadata of each in situ measurement (original source, cruise or experiment, principal investigator) were preserved throughout the work and made available in the final table. Using all the data in a validation exercise increases the number of matchups and enhances the representativeness of different marine regimes. By making available the metadata, it is also possible to analyse each set of data separately.
Resumo:
Este trabalho propõe o desenvolvimento de métodos de preparo de amostra empregando a microextração líquido-líquido dispersiva (DLLME) para a extração e pré- concentração de Fe e Cu em vinho, seguido da determinação espectrofotométrica na região do ultravioleta-visível (UV-Vis). Nas extrações por DLLME, a complexação de Fe e Cu foi feita com pirrolidina ditiocarbamato de amônio (APDC) e dietilditiocarbamato de sódio (DDTC), respectivamente. Para a DLLME, foi usada uma mistura apropriada de pequenos volumes de dois solventes, um extrator e outro dispersor, a qual foi rapidamente injetada na amostra aquosa, ocorrendo à formação de uma dispersão e a extração praticamente instantânea dos analitos. Na otimização da DLLME para extração de Fe foram avaliados alguns parâmetros como, tipo de solvente extrator (C2Cl4, 80 µL) e dispersor (acetonitrila, 1300 µL) e seus volumes, pH (3,0), concentração do APDC (1%, m/v), adição de NaCl (0,02 mol L -1 ) e tempo de extração. Para extração de Cu foi aplicado um planejamento fatorial completo 25 para avaliar a influência de cinco variáveis independentes: volume dos solventes dispersor (acetonitrila, 1600 µL) e extrator (CCl4, 60 µL), concentração de DDTC (2%, m/v), pH (3,0) e concentração de NaCl. Após a otimização das condições para Fe, a curva de calibração com adição de analito foi linear entre 0,2 e 2,5 mg L-1 para vinho branco (R2 = 0,9985) e para vinho tinto (R2 = 0,9988). Para Cu, a curva de calibração com adição de analito foi linear entre 0,05 e 1,0 mg L-1 para vinho branco (R2 = 0,9995) e para vinho tinto (R2 = 0,9986). Os limites de quantificação foram de 0,75 e 0,37 mg L-1 para Fe e Cu, respectivamente. A exatidão foi avaliada utilizando ensaio de recuperação, as quais variaram entre 96% e 112%, com desvio padrão relativo inferior a 8%. Os métodos foram aplicados para 5 amostras de vinho branco e 5 amostras de vinho tinto, obtendo-se concentrações entre 1,3 e 5,3 e entre 2,5 e 4,4 mg L-1 para Fe e entre 0,4 e 1,5 e entre 0,9 e 2,5 mg L-1 para Cu, respectivamente. Os métodos desenvolvidos para a extração e pré-concentração de Fe e Cu em vinhos por DLLME e quantificação por UV-Vis mostraram-se adequados, em termos de linearidade, exatidão e precisão.
Resumo:
Neste trabalho foi desenvolvido e validado um método analítico para a determinação de Fe total em amostras de água com diferentes salinidades empregando a microextração líquido-líquido dispersiva (DLLME), seguido de determinação espectrofotométrica na região do ultravioleta-visível. Nas extrações por DLLME, o Fe foi complexado com pirrolidina ditiocarbamato de amônio (APDC) e extraído após a injeção de uma mistura composta de 1,2-diclorobenzeno (solvente extrator) e etanol (solvente dispersor). Os fatores que influenciam a eficiência de extração (tipo e volume de solvente extrator e dispersor, concentração de APDC e tempo de extração) e subsequente determinação espectrofotométrica foram otimizados. Após otimização das condições, a curva de calibração foi linear entre 0,02 e 2,0 mg L-1 (r 2 = 0,9998) e os limites de detecção e quantificação do método foram de 6,1 e 18,3 µg L-1 , respectivamente. O fator de pré-concentração foi de 3,3. A exatidão foi avaliada em termos de recuperação, com variação entre 90 e 102% e desvio padrão relativo (RSD) inferiores a 12%. A exatidão do método também foi avaliada utilizando um material de referência certificado (SRM 1643e, Elementos Traço em Água), o qual apresentou concordância de 104% e RSD de 5%. O método foi aplicado para amostras de água com diferentes salinidades, como água mineral, estuarina e de alto mar. Além disso, o método proposto apresentou concordância da ordem de 95%, quando comparado com o método 1,10-fenantrolina para a determinação de Fe total.
Resumo:
A stability-indicating high-performance liquid chromatographic (HPLC) and a second-order derivative spectrophotometric (UVDS) analytical methods were validated and compared for determination of simvastatin in tablets. The HPLC method was performed with isocratic elution using a C18 column and a mobile phase composed of methanol:acetonitrile:water (60:20:20, v/v/v) at a flow rate of 1.0 ml/min. The detection was made at 239 nm. In UVDS method, methanol and water were used in first dilution and distilled water was used in consecutive dilutions and as background. The second-order derivative signal measurement was taken at 255 nm. Analytical curves showed correlation coefficients > 0.999 for both methods. The quantitation limits (QL) were 2.41 mu g/ml for HPLC and 0.45 mu g/ml for UVDS, respectively. Intra and inter-day relative standard deviations were < 2.0 %. Statistical analysis with t- and F-tests are not exceeding their critical values demonstrating that there is no significant difference between the two methods at 95 % confidence level.
Resumo:
High performance liquid chromatographic (HPLC) and UV derivative spectrophotometric (UVDS) methods were developed and validated for the quantitative determination of sotalol hydrochloride in tablets. The HPLC method was performed on a C18 column with fluorescence detection. The excitation and emission wavelengths were 235 and 310nm, respectively. The mobile phase was composed of acetonitrile-water containing 0.1% trietylamine (7:93v/v) and pH adjusted to 4.6 with formic acid. The UVDS method was performed taking a signal at 239.1nm in the first derivative. The correlation coefficients (r) obtained were 0.9998 and 0.9997 for HPLC and UVDS methods, respectively. The proposed methods are simple and adaptable to routine analysis.
Resumo:
UV-VIS-Spectrophotometric and spectrofluorimetric methods have been developed and validated allowing the quantification of chloroaluminum phthalocyanine (CIAIPc) in nanocarriers. In order to validate the methods, the linearity, limit of detection (LOD), limit of quantification (LOQ), precision, accuracy, and selectivity were examined according to USP 30 and ICH guidelines. Linearities range were found between 0.50-3.00 mu g.mL(-1) (Y=0.3829 X [CIAIPc, mu g.mL(-1)] + 0.0126; r=0.9992) for spectrophotometry, and 0.05-1.00 mu g.mL(-1) (Y=2.24 x 10(6) X [CIAIPc, mu g.L(-1)] + 9.74 x 10(4); r=0.9978) for spectrofluorimetry. In addition, ANOVA and Lack-of-fit tests demonstrated that the regression equations were statistically significant (p<0.05), and the resulting linear model is fully adequate for both analytical methods. The LOD values were 0.09 and 0.01 mu g.mL(-1), while the LOCI were 0.27 and 0.04 mu g.mL(-1) for spectrophotometric and spectrofluorimetric methods, respectively. Repeatability and intermediate precision for proposed methods showed relative standard deviation (RSD) between 0.58% to 4.80%. The percent recovery ranged from 98.9% to 102.7% for spectrophotometric analyses and from 94.2% to 101.2% for spectrofluorimetry. No interferences from common excipients were detected and both methods were considered specific. Therefore, the methods are accurate, precise, specific, and reproducible and hence can be applied for quantification of CIAIPc in nanoemulsions (NE) and nanocapsules (NC).
Resumo:
A simple, fast and sensitive spectrophotometric method for the determination of cefaclor in pharmaceutical raw and dosage forms based on reaction with ninhydrin is developed, optimized and validated. The purple color (Ruhemenn's purple) that resulted from the reaction was stabilized and measured at 560 nm. Beer's law is obeyed in the concentration range of 4-80 µg mL-1 with molar absorptivity of 1.42 × 10(5) L mole-1 cm-1. All variables including the reagent concentration, heating time, reaction temperature, color stability period, and cefaclor/ninhydrin ratio were studied in order to optimize the reaction conditions. No interference was observed from common pharmaceutical adjuvant. The developed method is easy to use, accurate and highly cost-effective for routine studies relative to HPLC and other techniques.
Resumo:
The objective of this research was to develop and validate an alternative analytical method for quantitative determination of levofloxacin in tablets and injection preparations. The calibration curves were linear over a concentration range from 3.0 to 8.0 μg mL-1. The relative standard deviation was below 1.0% for both formulations and average recovery was 101.42 ± 0.45% and 100.34 ± 0.85% for tablets and injection formulations, respectively. The limit of detection and limit of quantitation were 0.08 and 0.25 μg mL-1, respectively. It was concluded that the developed method is suitable for the quality control of levofloxacin in pharmaceuticals formulations.
Resumo:
A derivative UV spectrophotometric method for determination of estradiol valerate in tablets was validated. The parameters specificity, linearity, precision, accuracy, limit of detection and limit of quantitation were studied according to validation guidelines. The first-order derivative spectra were obtained at N = 5, Δλ = 4.0 nm, and determinations were made at 270 nm. The method showed specificity and linearity in the concentration range of 0.20 to 0.40 mg mL-1. The intra and interday precision data demonstrated the method has good reproducibility. Accuracy was also evaluated and results were satisfactory. The proposed method was successfully applied to a pharmaceutical formulation.
Resumo:
For determination of aliskiren in commercial samples, an analytical UV spectrophotometric method was developed and validate according to ICH guideline. The method was linear in the range between 40 and 100 μg mL-1 (r² = 0.9997, n = 7) and exhibited suitable specificity, accuracy, precision, and robustness. It is simple, it has low cost, and it has low use polluting reagents. Therefore, the proposed method was successfully applied for the assay and dissolution studies of aliskiren in tablet dosage forms, and the results were compared to a validated RP-LC method, showing non-significant difference (P > 0.05).
Resumo:
Nitrate is quantitatively retained with 2,6-bis(4-methoxyphenyl)-4-phenyl pyrylium perchlorate (PPP) on microcrystalline naphthalene in the pH range of 6.5-9.0 from a large volume of aqueous solutions of various samples. The method was based on the complexation between PPP and nitrate and then, extraction of the resulted complex from aqueous solution by microcrystalline naphthalene. The solid mass consisting of the nitrate complex and naphthalene was then dissolved in dimethyl formamide (DMF) and absorption of the resulted solution was obtained at 328 nm. The linear calibration range for the determination of nitrate was 15-135 μg L-1 with the detection limit of 10 μg L-1.
Resumo:
Sensitive and selective spectrophotometric and spectrofluorimetric methods have been developed for determination of some drugs such as Pramipexole, Nebivolol, Carvedilol, and Eletriptan, which commonly contain secondary amino group. The subject methods were developed via derivatization of the secondary amino groups with 7-Chloro-4-Nitrobenzofurazon in borate buffer where a yellow colored reaction product was obtained and measured spectrophotometrically or spectrofluorimetrically. Concentration ranges were found as 2.0 to 250 μg mL-1 and 0.1 to 3.0 μg mL-1, for spectrophotometric and spectrofluorimetric study, respectively. The described methods can be easily applied by the quality control laboratories in routine analyses of these drugs in pharmaceutical preparations.