444 resultados para Multichannel perimetry


Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper describes some aspects of multichannel spectrophotometry, principles of photodiode arrays and their applications in Analytical Chemistry.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This thesis is focused on process intensification. Several significant problems and applications of this theme are covered. Process intensification is nowadays one of the most popular trends in chemical engineering and attempts have been made to develop a general, systematic methodology for intensification. This seems, however, to be very difficult, because intensified processes are often based on creativity and novel ideas. Monolith reactors and microreactors are successful examples of process intensification. They are usually multichannel devices in which a proper feed technique is important for creating even fluid distribution into the channels. Two different feed techniques were tested for monoliths. In the first technique a shower method was implemented by means of perforated plates. The second technique was a dispersion method using static mixers. Both techniques offered stable operation and uniform fluid distribution. The dispersion method enabled a wider operational range in terms of liquid superficial velocity. Using dispersion method, a volumetric gas-liquid mass transfer coefficient of 2 s-1 was reached. Flow patterns play a significant role in terms of the mixing performance of micromixers. Although the geometry of a T-mixer is simple, channel configurations and dimensions had a clear effect on mixing efficiency. The flow in the microchannel was laminar, but the formation of vortices promoted mixing in micro T-mixers. The generation of vortices was dependent on the channel dimensions, configurations and flow rate. Microreactors offer a high ratio of surface area to volume. Surface forces and interactions between fluids and surfaces are, therefore, often dominant factors. In certain cases, the interactions can be effectively utilised. Different wetting properties of solid materials (PTFE and stainless steel) were applied in the separation of immiscible liquid phases. A micro-scale plate coalescer with hydrophilic and hydrophobic surfaces was used for the continuous separation of organic and aqueous phases. Complete phase separation occurred in less than 20 seconds, whereas the separation time by settling exceeded 30 min. Fluid flows can be also intensified in suitable conditions. By adding certain additives into turbulent fluid flow, it was possible to reduce friction (drag) by 40 %. Drag reduction decreases frictional pressure drop in pipelines which leads to remarkable energy savings and decreases the size or number of pumping facilities required, e.g., in oil transport pipes. Process intensification enables operation often under more optimal conditions. The consequent cost savings from reduced use of raw materials and reduced waste lead to greater economic benefits in processing.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Using event-related brain potentials, the time course of error detection and correction was studied in healthy human subjects. A feedforward model of error correction was used to predict the timing properties of the error and corrective movements. Analysis of the multichannel recordings focused on (1) the error-related negativity (ERN) seen immediately after errors in response- and stimulus-locked averages and (2) on the lateralized readiness potential (LRP) reflecting motor preparation. Comparison of the onset and time course of the ERN and LRP components showed that the signs of corrective activity preceded the ERN. Thus, error correction was implemented before or at least in parallel with the appearance of the ERN component. Also, the amplitude of the ERN component was increased for errors, followed by fast corrective movements. The results are compatible with recent views considering the ERN component as the output of an evaluative system engaged in monitoring motor conflict.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

An important component for the automation of flow injection analysis (FIA) systems is the sample injection valve. A simple and inexpensive commutator with 16 pinch valves (8 normally open and 8 closed) was developed and configured as a multichannel injection valve. It is activated by a single solenoid of 3 Kgf, powered by a pulsed driver circuit, controlled by a microcomputer or a switch. FIA with spectrophometric detection of potassium dichromate solution was used for the evaluation of the new injection valve and its comparison with other valves, for sample loops of 50, 100, 200, 300 and 500 muL. The repeatability was favorable (RSD 1.0% for 15 injections at each loop volume) compared to a manual injector, an electropneumatic injector and an injector configured with three mini solenoid valves (RSD 1.1, 1.3 and 1.0%, respectively, for15 injections at each loop volume).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Spatiotemporal pattern formation in reaction-transport systems takes place spontaneously when the system is kept far from thermodynamic equilibrium. Targets, reaction fronts, waves, spirals, spots and stripes are some typical examples of selforganized structuring. In electrochemical systems, monitoring spatiotemporal patterns of potential in the solid/liquid interface can be done by the use of equally distributed microprobes located close to the working electrode. However, the physical size of each probe can limit the spatial resolution and alter mass transport properties. In contrast, the direct measurement of discrete electrodes does not suffer from this limitation and allows the accurate manipulation of the spatial coupling through changes in resistors connected to the electric circuit. In this paper, the development of an electrochemical setup for multichannel data acquisition with spatiotemporal resolution is described, especially to monitor low levels of currents usually observed in the electro-oxidation of small organic molecules.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Brazilian surgeons deal routinely with esophageal motility disorders, because achalasia is highly prevalent in Brazil due to Chagas' disease. In the last years new technologies for the evaluation of esophageal motility became available. High resolution manometry and the combination of barometric parameters and intraluminal impedance are the new frontiers on this topic. The authors reviewed current, national and international, literature about achalasia with multichannel intraluminal impedance and high resolution manometry studies. The new technologies described are promising, however few studies have been published and further studies are still expected for achalasia patients.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To identify the predictive factors for voiding dysfunction after transobturator slings. METHODS: We retrospectively reviewed the records of all patients who underwent a transobturator sling between March 2003 and December 2008. A total of 514 women had available data with at least a six-week follow-up. Patients' demographics, preoperative symptoms, urodynamic testing including multichannel voiding studies and surgical variables were tabulated. Voiding dysfunction was defined by a catheterized or ultrasonographic postvoid residual greater than 100 cc (≥six weeks after the procedure) associated with any complaints of abnormal voiding. Univariate logistic regression analysis was performed with respect to postoperative voiding dysfunction. RESULTS: The patient population had a mean age of 58.5±12.9 years. Thirty-three out of 514 patients (6.4%) had postoperative voiding dysfunction according to our definition, and 4 (0.78%) required sling transection. No differences were observed between normal and dysfunctional voiders in age, associated prolapse surgery, preoperative postvoid residual, preoperative urinary flow rate, prior pelvic surgery, and menopausal status. Valsalva efforts during the preoperative pressure flow study was the only predictive factor for postoperative voiding dysfunction, 72.4% dysfunctional versus 27.6% normal (p<0.001). CONCLUSION: Preoperative Valsalva maneuver during the micturition could identify those at risk for voiding dysfunction after transobturator sling, and it should be noted during preoperative counseling.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The birth of Internet technologies, the developments of fast fashion and multiple retailing channels have created a need for a new, more integrated way for doing retailing. Agility in fast fashion retailing could be seen as a significant way of responding to these changes and furthermore, as a way to respond to consumers’ altering demands. The purpose of this study was to explore the ways in which agile supply chains and integrated multichannel retailing influence the international fast fashion retailing. A framework for agility in retail was developed based on available theoretical considerations in distribution and communication channels. Qualitative research methods and qualitative content analysis were used. Four expert interviews were carried out to gain new perspectives to the objectives. The rest of the data was collected from an industry specific document, expert video and two expert lectures. Following the data collection, the research material was analyzed with qualitative content analysis. The empirical findings on agility in retail were presented based on a coding frame. It was found that agility in retail has multiple parts, which are overlapping and affecting one another. Furthermore, instead of viewing the agile supply chain and integrated multichannel retailing separately of each other as usual, it was found that they should be integrated, and the term “agility” was proposed to denote this approach. Also, it was found that the most common drivers and constrains of integrated multichannel retailing were the new Internet technologies and customer demand. Brick-and-mortar store, online store, mobile devices and social media were found to be the most common retailing channels. Furthermore, in-store technology, click-and-collect approach, NFC-buying, RFID-technology as well as 3D- digital simulations on fabrics and patterns will enhance agility even more in the future. In addition, environmental issues, customer experiences and communication will be important factors. This study has provided new practical insights for the future retailing. Furthermore, it has contributed to the academic research by discussing the traditional approaches of agility in fast fashion retail and bringing in new insights.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A fast changing dynamic business environment is becoming a norm today in different areas, including retailing. The aims of this study are to explore existing store formats of branded sportswear retailing and their characteristics, and to identify the trends which might shape their future. The ultimate goal, however, is to create and analyze images of the future of branded sportswear retailing in Germany 2030 by applying the methods of futures studies. As theoretical background, the cyclical theories of retail evolution have been used. Empirical material is obtained by conducting a Disaggregative Policy Delphi method based study, the aim of which is to obtain well–argued qualitative and quantitative information from experts about store format development in order to create future images based on cluster analysis. Flagship stores, Concept stores, Factory Outlets, Pop-up stores, E-commerce and M-commerce represent the diversity of store formats existing in Germany today. They have different aims, roles, and advantages which retailers try to leverage. However such trends as multichannel integration, technological enhancements, growing popularity of online channels, switching customer behaviors, customization and personalization, and economic turbulence might shape the future of sportswear retailing. Four future images constructed: “Multichannel Integration”, “Smart and Personal”, “Consumer Diversification”, and “Always Online” – describe alternative futures of German branded sportswear store formats in 2030 based on different trends, assumptions, hopes and fears. They also point out uncertainties in retailing such as cannibalization of channels, the growing power and expectations of consumers, the complexity of multichannel synergies, and the switching customer behavior. Constructed future images, thus, provide readers with an opportunity to imagine and explore alternative states of the future of branded sportswear store formats in Germany 2030. They could serve well as a tool to communicate the results to decision–makers, compare them, and to analyze to inspire and direct actions for a better future tomorrow.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Customer knowledge management (CKM) practices enable organizations to create customer competence with systematic use of customer information that is integrated throughout the organization. Nonetheless, organizations are not able to fully exploit the vast amount of data available. Previous research on use of customer information is limited especially in a multichannel environment. The aim of this study was to identify the main obstacles for utilizing customer information efficiently across multiple sales channels. The study was conducted as a single case study in order to gain deeper understanding of the research problem. The empirical findings indicate that lack of CKM practices and a common goal are major challenges obstructing effective utilization of customer information. Furthermore, decentralized organizational structure and insufficient analytical skills create obstacles for information sharing and capabilities to process information and create new knowledge. The implications of the study suggest that in order to create customer competence organizations should shift their focus from technology to the organizational factors affecting use of information and implement CKM practices throughout the organization.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Tämän tapaustutkimuksen tavoitteena oli selvittää esimerkkiyrityksen kilpailuetu ympäristössä, jossa kilpailu kansainvälistyy ja monikanavaistuu. Tutkittava yritys on rautakauppa-alan johtava brändi Suomessa. Yritys on tutkimuksen tekemisen aikana ostettu osaksi toimialan Pohjoismaiden suurinta verkkokauppakonsernia. Kvalitatiivinen tutkimus suoritettiin tapaustutkimuksena, johon kuului osana kvantitatiivinen asiakaskysely. Tutkittavalla yrityksellä on verkkokaupan lisäksi kaksi showroom-tyyppistä myymälää, joten asiakaskysely suoritettiin kahdessa osassa erikseen myymälän ja verkkokaupan osalta. Tutkimuksen teoriaosuudessa käsiteltiin tärkeimmät kilpailustrategian teoriat alkaen M.E.Porterin kilpailuetuteoriasta päätyen Kimin ja Mauborgnen Sinisen meren strategiaan. Tutkimuksen tuloksena selvisi, että yrityksellä ei ole selkeätä kilpailuetua. Uuden omistajan myötä on mahdollisuus rakentaa kestävä kilpailuetu. Tutkimustuloksena muodostui myös näkemys, miten yrityksen strategista suunnittelua pitäisi kehittää sekä muodostui ehdotus jatkotutkimukselle. Tutkimuksen pohjalta rakentui malli monikanavaisen DIY- kaupan arvoketjusta ja kehitysehdotus esimerkkiyrityksen arvoketjun kehittämisestä.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A method is presented for determining the composition of thin films containing the elements Bi, Sr, Br, Cu, and Ca. Quantitative x-ray fluorescence (XRF) consisting of radioactive sources (secondary foil excitor 241Am-Mo source and 55Pe source), a Si(Li) detector, and a multichannel analyzer were employed. The XRF system was calibrated by using sol gel thin films of known element composition and also by sputtered thin films analyzed by the conventional Rutherford Back Scattering (RBS). The XRF system has been used to assist and optimize the sputter target composition required to produce high-Tc BiSrCaCuO films with the desired metal composition.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Sommaire L’oxygène fait partie intégrante de l’environnement et ceci jusqu’au fonctionnement même des structures cellulaires qui composent le corps humain. Deux systèmes sont intimement liés à la distribution de l’oxygène, ce sont les systèmes cardiovasculaire et respiratoire. La transparence du système optique de l’œil peut être exploitée afin de mesurer de façon non invasive la concentration en oxyhémoglobine du sang qui alimente le système nerveux central. L’oxygénation capillaire de l’œil a été mesurée par spectro-réflectométrie dans deux régions de l’œil: d’une part les capillaires de la zone du nerf optique qui représentent principalement la circulation rétinienne; d’autre part, les capillaires du limbe cornéen. Cinq sujets volontaires, non fumeurs, sains, âgés de 20 à 45 ans et cinq sujets volontaires, fumeurs, sains, âgés de 20 à 40 ans ont participé à cette étude. Tous ces sujets ont été exposés à des conditions d’hyper et d’hypo oxygénation. Une séance d’expérimentations était composée d’un enregistrement continu de 360 secondes. Durant la première étape de 60 secondes, le sujet respirait de l’air ambiant. Durant une deuxième étape de 180 secondes, le sujet était exposé soit à une condition d’hyper (60% O2) soit, à une condition d’hypo oxygénation (15% O2), tandis que les 120 dernières secondes de la séance de mesure permettait d’exposer le sujet, une fois de plus à l’air ambiant. Le rythme cardiaque et les changements d’oxygénation artérielle au niveau du doigt étaient mesurés pendant ce temps vec le sphygmo-oxymètre. Les variations du taux d’oxyhémoglobine du sang au niveau capillaire de l’œil (nerf optique ou sclérotique) étaient toujours en corrélation directe avec les variations du taux d’oxyhémoglobine artériel. Toutefois, les capillaires du nerf optique offrent plus de précision pour les mesures d’oxygénation, relativement aux mesures d’oxygénation du sang contenu dans les capillaires de la sclérotique. La précision de la mesure de la concentration d’oxyhémoglobine obtenue dans cette étude par spectro-réflectométrie de l’œil, en fait un instrument utile au diagnostic d’une grande partie des pathologies pulmonaires ou oculaires.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Le glaucome représente la première cause de cécité irréversible à l’échelle mondiale. C’est une maladie neuro-dégénérative caractérisée traditionnellement par une pression intraoculaire (PIO) élevée, un dommage du nerf optique et un défaut du champ visuel correspondant. En fait, la PIO élevée constitue le facteur de risque central associé au développement du glaucome. Cependant, en dépit d’un contrôle adéquat de la PIO, la maladie continue à progresser chez certains patients. Cela montre qu’il existe d’autres facteurs impliqués dans la pathogenèse du glaucome. Des études récentes indiquent qu’un dérèglement de l’oxygène est associé à son développement. En utilisant une nouvelle technologie multi-spectrale capable de mesurer la saturation en oxygène (SaO2) dans les structures capillaires de la rétine, cette étude tentera de déterminer si un état d’oxygénation anormal pourrait se retrouver à la papille optique des patients souffrant de glaucome. Une meilleure compréhension du rôle de l’oxygène pourrait aider à améliorer le pronostic du glaucome. Les résultats de l’étude indiquent que le facteur de position (supérieure, temporale et inférieure de la papille optique) n’a aucun effet sur la mesure SaO2 ainsi que sa variabilité chez les patients normaux. La comparaison de la SaO2 entre les sujets normaux et glaucomateux ne montre pas de différence statistiquement significative. En conclusion, la SaO2 «normale» mesurée dans les yeux glaucomateux n'exclut pas nécessairement que l'hypoxie ne soit pas impliquée dans la pathogenèse. Au moment de l’étude, la PIO était bien contrôlée par des médicaments topiques, ce qui pourrait influencer l’oxygénation à la papille optique.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

L’examen de la rétine par des moyens non invasifs et in vivo a été un objectif de recherche pendant plusieurs années. Pour l’œil comme pour tous les organes du corps humain, un apport soutenu en oxygène est nécessaire pour le maintien de l’homéostasie. La concentration en oxygène du sang des vaisseaux rétiniens peut être déterminée principalement à partir des mesures du spectre de réflexion du fond de l’œil. En envoyant une lumière, à différentes longueurs d’onde, sur la rétine et en analysant la nature de la lumière réfléchie par la rétine, il est possible d’obtenir des informations quantitatives sur le niveau d'oxygène dans les vaisseaux sanguins de la rétine ou sur le flux sanguin. Cependant, la modélisation est compliquée due aux différentes interactions et aux chemins que la lumière prend à travers les tissus oculaires avant de quitter l’œil. L’objectif de cette thèse a été de développer et de valider un modèle mathématique afin de calculer les dérivées d’hémoglobine à partir de mesures spectrales de réflectométrie sur les vaisseaux sanguins de la rétine. L’instrument utilisé pour mesurer la fonction spectrale de réflectométrie a été un spectroréflectomètre multi-canal, une technologie capable de mesurer in vivo et en continu 800 spectres simultanément. L'équation mathématique qui décrit la fonction spectrale de réflectométrie dans la zone spectrale de 480 nm à 650 nm a été exprimée comme la combinaison linéaire de plusieurs termes représentant les signatures spectrales de l'hémoglobine SHb, de l'oxyhémoglobine SOHB, l’absorption et la diffusion des milieux oculaires et une famille de fonctions multigaussiennes utilisées pour compenser l’incompatibilité du modèle et les données expérimentales dans la zone rouge du spectre. Les résultats du modèle révèlent que le signal spectral obtenu à partir de mesures de réflectométrie dans l’œil est complexe, contenant la lumière absorbée, réfléchie et diffusée, mais chacun avec une certaine prédominance spécifique en fonction de la zone spectrale. La fonction spectrale d’absorption du sang est dominante dans la zone spectrale 520 à 580 nm, tandis que dans la zone spectrale de longueurs d’ondes plus grandes que 590 nm, la diffusion sur les cellules rouges du sang est dominante. Le modèle a été utilisé afin de mesurer la concentration d’oxygène dans les capillaires de la tête du nerf optique suite à un effort physique dynamique. L’effort physique a entraîné une réduction de la concentration d’oxygène dans les capillaires, ainsi qu’une réduction de la pression intraoculaire, tandis que la saturation sanguine en oxygène, mesurée au niveau du doigt, restait constante. Le modèle mathématique développé dans ce projet a ainsi permis, avec la technique novatrice de spectroréflectométrie multicanal, de déterminer in vivo et d’une manière non invasive l’oxygénation sanguine des vaisseaux rétiniens.