867 resultados para Fire departments


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fire resistance rating of light gauge steel frame (LSF) wall systems is obtained from fire tests based on the standard fire time-temperature curve. However, fire severity has increased in modern buildings due to higher fuel loads as a result of modern furniture and light weight constructions that make use of thermoplastics materials, synthetic foams and fabrics. Some of these materials are high in calorific values and increase both the spread of fire growth and heat release rate, thus increasing the fire severity beyond that of the standard fire curve. Further, the standard fire curve does not include a decay phase that is present in natural fires. Despite the increasing usage of LSF walls, their behaviour in real building fires is not fully understood. This paper presents the details of a research study aimed at developing realistic design fire curves for use in the fire tests of LSF walls. It includes a review of the characteristics of building fires, previously developed fire time-temperature curves, computer models and available parametric equations. The paper highlights that real building fire time-temperature curves depend on the fuel load representing the combustible building contents, ventilation openings and thermal properties of wall lining materials, and provides suitable values of many required parameters including fuel loads in residential buildings. Finally, realistic design fire time-temperature curves simulating the fire conditions in modern residential buildings are proposed for the testing of LSF walls.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Recent literature acknowledges the need for new career development models to support the way that careers evolve in the 21st century workplace (Bloch 2005). This is particularly so within temporary organisation forms, and for those pursuing a career in project management (Hölzle 2010). Our research, explores how project managers working on projects and within temporary organisation forms and those working on project-linked contracts access the development opportunities they require to remain employable in an era of project-by-project employment. Set in Australia where a project-based economy (Crawford, French and Lloyd-Walker 2013) and contract work have led to casualisation of the workforce (Connell & Burgess, 2006; McKeown & Hanley (2009) the results suggest new approaches to career development may be required.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dr Ian Weir appears on ABC Televisions WA Statewide program to discuss the H House (featured) and the cost savings associated with taking an integrated approach to building in bushfire prone areas.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An updated analysis of the previous analysis available here: http://eprints.qut.edu.au/76230/

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We describe the development and parameterization of a grid-based model of African savanna vegetation processes. The model was developed with the objective of exploring elephant effects on the diversity of savanna species and structure, and in this formulation concentrates on the relative cover of grass and woody plants, the vertical structure of the woody plant community, and the distribution of these over space. Grid cells are linked by seed dispersal and fire, and environmental variability is included in the form of stochastic rainfall and fire events. The model was parameterized from an extensive review of the African savanna literature; when available, parameter values varied widely. The most plausible set of parameters produced long-term coexistence between woody plants and grass, with the tree-grass balance being more sensitive to changes in parameters influencing demographic processes and drought incidence and response, while less sensitive to fire regime. There was considerable diversity in the woody structure of savanna systems within the range of uncertainty in tree growth rate parameters. Thus, given the paucity of height growth data regarding woody plant species in southern African savannas, managers of natural areas should be cognizant of different tree species growth and damage response attributes when considering whether to act on perceived elephant threats to vegetation. © 2007 Springer Science+Business Media B.V.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

There is a concern that high densities of elephants in southern Africa could lead to the overall reduction of other forms of biodiversity. We present a grid-based model of elephant-savanna dynamics, which differs from previous elephant-vegetation models by accounting for woody plant demographics, tree-grass interactions, stochastic environmental variables (fire and rainfall), and spatial contagion of fire and tree recruitment. The model projects changes in height structure and spatial pattern of trees over periods of centuries. The vegetation component of the model produces long-term tree-grass coexistence, and the emergent fire frequencies match those reported for southern African savannas. Including elephants in the savanna model had the expected effect of reducing woody plant cover, mainly via increased adult tree mortality, although at an elephant density of 1.0 elephant/km2, woody plants still persisted for over a century. We tested three different scenarios in addition to our default assumptions. (1) Reducing mortality of adult trees after elephant use, mimicking a more browsing-tolerant tree species, mitigated the detrimental effect of elephants on the woody population. (2) Coupling germination success (increased seedling recruitment) to elephant browsing further increased tree persistence, and (3) a faster growing woody component allowed some woody plant persistence for at least a century at a density of 3 elephants/km2. Quantitative models of the kind presented here provide a valuable tool for exploring the consequences of management decisions involving the manipulation of elephant population densities. © 2005 by the Ecological Society of America.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fire safety design of buildings is essential to safeguard lives and minimize the loss of damage to properties. Light-weight cold-formed steel channel sections along with fire resistive plasterboards are used to construct light gauge steel frame floor systems to provide the required fire resistance rating. However, simply adding more plasterboard layers is not an efficient method to increase FRR. Hence this research focuses on using joists with improved joist section profiles such as hollow flange sections to increase the structural capacity of floor systems under fire conditions and thus their FRR. In this research, the structural and thermal behaviour of LSF floor systems made of LiteSteel Beams with different plasterboard and insulation configurations was investigated using four full scale tests under standard fires. Based on the ultimate failure load of the floor joist at ambient temperature, transient state fire tests were conducted for different Load Ratios. These fire tests showed that the new LSF floor system has improved the FRR well above that of those made of lipped channel sections. The joist failure was predominantly due to local buckling of LSB compression flanges near mid-span with severe yielding of tension flanges. Fire tests have provided valuable structural and thermal performance data of tested floor systems that included time-temperature profiles, and failure times and temperatures. Average failure temperatures of LSB joists and reduced yield strengths were used to predict their ultimate moment capacities, which were compared with corresponding test capacities. This allowed an assessment in relation to the accuracy of current design rules for steel joists at elevated temperatures. This paper presents the details of full scale fire tests of LSF floor systems made of LSB joists with different plasterboard and insulation configurations and their results along with some important findings.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives The objective of this study was to develop process quality indicators (PQIs) to support the improvement of care services for older people with cognitive impairment in emergency departments (ED). Methods A structured research approach was taken for the development of PQIs for the care of older people with cognitive impairment in EDs, including combining available evidence with expert opinion (phase 1), a field study (phase 2), and formal voting (phase 3). A systematic review of the literature identified ED processes targeting the specific care needs of older people with cognitive impairment. Existing relevant PQIs were also included. By integrating the scientific evidence and clinical expertise, new PQIs were drafted and, along with the existing PQIs, extensively discussed by an advisory panel. These indicators were field tested in eight hospitals using a cohort of older persons aged 70 years and older. After analysis of the field study data (indicator prevalence, variability across sites), in a second meeting, the advisory panel further defined the PQIs. The advisory panel formally voted for selection of those PQIs that were most appropriate for care evaluation. Results In addition to seven previously published PQIs relevant to the care of older persons, 15 new indicators were created. These 22 PQIs were then field tested. PQIs designed specifically for the older ED population with cognitive impairment were only scored for patients with identified cognitive impairment. Following formal voting, a total of 11 PQIs were included in the set. These PQIs targeted cognitive screening, delirium screening, delirium risk assessment, evaluation of acute change in mental status, delirium etiology, proxy notification, collateral history, involvement of a nominated support person, pain assessment, postdischarge follow-up, and ED length of stay. Conclusions This article presents a set of PQIs for the evaluation of the care for older people with cognitive impairment in EDs. The variation in indicator triggering across different ED sites suggests that there are opportunities for quality improvement in care for this vulnerable group. Applied PQIs will identify an emergency services' implementation of care strategies for cognitively impaired older ED patients. Awareness of the PQI triggers at an ED level enables implementation of targeted interventions to improve any suboptimal processes of care. Further validation and utility of the indicators in a wider population is now indicated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives The purpose of this study was to identify the structural quality of care domains and to establish a set of structural quality indicators (SQIs) for the assessment of care of older people with cognitive impairment in emergency departments (EDs). Methods A structured approach to SQI development was undertaken including: 1) a comprehensive search of peer-reviewed and gray literature focusing on identification of evidence-based interventions targeting structure of care of older patients with cognitive impairment and existing SQIs; 2) a consultative process engaging experts in the care of older people and epidemiologic methods (i.e., advisory panel) leading to development of a draft set of SQIs; 3) field testing of drafted SQIs in eight EDs, leading to refinement of the SQI set, and; 4) an independent voting process among the panelists for SQI inclusion in a final set, using preestablished inclusion and exclusion criteria. Results At the conclusion of the process, five SQIs targeting the management of older ED patients with cognitive impairment were developed: 1) the ED has a policy outlining the management of older people with cognitive impairment during the ED episode of care; 2) the ED has a policy outlining issues relevant to carers of older people with cognitive impairment, encompassing the need to include the (family) carer in the ED episode of care; 3) the ED has a policy outlining the assessment and management of behavioral symptoms, with specific reference to older people with cognitive impairment; 4) the ED has a policy outlining delirium prevention strategies, including the assessment of patients' delirium risk factors, and; 5) the ED has a policy outlining pain assessment and management for older people with cognitive impairment. Conclusions This article presents a set of SQIs for the evaluation of performance in caring for older people with cognitive impairment in EDs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Today, an Australian parliamentary committee grilled the IT titans - Apple, Adobe, and Microsoft - on price discrimination against Australian consumers. The IT companies were evasive under questioning.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives To inform demand management strategies aimed at reducing congestion in EDs by: (i) identifying public use of EDs, decision-making and reasons; and (ii) measuring acceptance of alternative care models. Methods A cross-sectional telephone survey of a random sample of Queensland population aged 18 years or older residing in a dwelling unit in Queensland that could be contacted on a land-based telephone service was conducted. One person per household was selected according to a predetermined algorithm to ensure sex and regional balance were interviewed. The main outcome measures were: ED use, attitudes towards ED staff and services, and alternative models of care. Results The final sample included a total of 1256 respondents (response rate = 40.3%). Twenty-one per cent attended EDs in the preceding 12 months. The decision to attend was made by patients (51%), health and medical professionals (31%), and others (18%). The main reasons included perceived severity of the illness (47%), unavailability of alternative services (26%) and better care (11%). Most respondents agreed with more flexible care models of service delivery including incentives for general practitioners (90%), private health insurance coverage for ED use (89%), and enhanced roles for paramedics and nurses. Conclusions Main reason for attending ED is perceived severity of illness, followed by lack of alternative care. The majority of both consumers and the public are in favour of more flexible care models. However, further research is necessary to detail those alternatives and to test and validate their effectiveness.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Light gauge Steel Frame (LSF) walls are extensively used in the building industry due to the many advantages they provide over other wall systems. Although LSF walls have been used widely, fire design of LSF walls is based on approximate prescriptive methods based on limited fire tests. Also these fire tests were conducted using the standard fire curve [1] and the applicability of available design rules to realistic design fire curves has not been verified. This paper investigates the accuracy of existing fire design rules in the current cold-formed steel standards and the modifications proposed by previous researchers. Of these the recently developed design rules by Gunalan and Mahendran [2] based on Eurocode 3 Part 1.3 [3] and AS/NZS 4600 [4] for standard fire exposure [1] were investigated in detail to determine their applicability to predict the axial compression strengths and fire resistance ratings of LSF walls exposed to realistic design fire curves. This paper also presents the fire performance results of LSF walls exposed to a range of realistic fire curves obtained using a finite element analysis based parametric study. The results from the parametric study were used to develop a simplified design method based on the critical hot flange temperature to predict the fire resistance ratings of LSF walls exposed to realistic fire curves. Finally, the stud failure times (fire resistance rating) obtained from the fire design rules and the simplified design method were compared with parametric study results for LSF walls lined with single and double plasterboards, and externally insulated with rock fibres under realistic fire curves.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Structural fire safety has become one of the key considerations in the design and maintenance of the built infrastructure. Conventionally the fire resistance rating of load bearing Light gauge Steel Frame (LSF) walls is determined based on the standard time-temperature curve given in ISO 834. Recent research has shown that the true fire resistance of building elements exposed to building fires can be less than their fire resistance ratings determined based on standard fire tests. It is questionable whether the standard time-temperature curve truly represents the fuel loads in modern buildings. Therefore an equivalent fire severity approach has been used in the past to obtain fire resistance rating. This is based on the performance of a structural member exposed to a realistic design fire curve in comparison to that of standard fire time-temperature curve. This paper presents the details of research undertaken to develop an energy based time equivalent approach to obtain the fire resistance ratings of LSF walls exposed to realistic design fire curves with respect to standard fire exposure. This approach relates to the amount of energy transferred to the member. The proposed method was used to predict the fire resistance ratings of single and double layer plasterboard lined and externally insulated LSF walls. The predicted fire ratings were compared with the results from finite element analyses and fire design rules for three different wall configurations exposed to both rapid and prolonged fires. The comparison shows that the proposed energy method can be used to obtain the fire resistance ratings of LSF walls in the case of prolonged fires.