891 resultados para Fault Diagnostics


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Multi-agent systems (MAS) advocate an agent-based approach to software engineering based on decomposing problems in terms of decentralized, autonomous agents that can engage in flexible, high-level interactions. This chapter introduces scalable fault tolerant agent grooming environment (SAGE), a second-generation Foundation for Intelligent Physical Agents (FIPA)-compliant multi-agent system developed at NIIT-Comtec, which provides an environment for creating distributed, intelligent, and autonomous entities that are encapsulated as agents. The chapter focuses on the highlight of SAGE, which is its decentralized fault-tolerant architecture that can be used to develop applications in a number of areas such as e-health, e-government, and e-science. In addition, SAGE architecture provides tools for runtime agent management, directory facilitation, monitoring, and editing messages exchange between agents. SAGE also provides a built-in mechanism to program agent behavior and their capabilities with the help of its autonomous agent architecture, which is the other major highlight of this chapter. The authors believe that the market for agent-based applications is growing rapidly, and SAGE can play a crucial role for future intelligent applications development. © 2007, IGI Global.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Hypokinesia, rigidity, tremor, and postural instability are the cardinal symptoms of Parkinson s disease (PD). Since these symptoms are not specific to PD the diagnosis may be uncertain in early PD. Etiology and pathogenesis of PD remain unclear. There is no neuroprotective therapy. Genetic findings are expected to reveal metabolic routes in PD pathogenesis and thereby eventually lead to therapeutic innovations. In this thesis, we first aimed to study the usefulness and accuracy of 123I-b-CIT SPECT in the diagnosis of PD in a consecutive clinic-based material including various movement disorders. We subsequently a genetic project to identify genetic risk factors for sporadic PD using a candidate gene approach in a case-control setting including 147 sporadic PD patients and 137 spouse controls. Dopamine transporter imaging by 123I-b-CIT SPECT could distinguish PD from essential tremor, drug-induced parkinsonism, dystonia and psychogenic parkinsonism. However, b-CIT uptake in Parkinson plus syndromes (PSP and multiple system atrophy) and dementia with Lewy bodies was not significantly different from PD. 123I-b-CIT SPECT could not reliably differentiate PD from vascular parkinsonism. 123I-b-CIT SPECT was 100% sensitive and specific in the diagnosis of PD in patients younger than 55 years but less specific in older patients, due to differential distribution of the above conditions in the younger and older age groups. 123I-b-CIT SPECT correlated with symptoms and detected bilateral nigrostriatal defect in patients whose PD was still in unilateral stage. Thus, in addition to as a differential diagnostic aid, 123I-b-CIT SPECT may be used to detect PD early, even pre-symptomatically in at-risk individuals. 123I-b-CIT SPECT was used to aid in the collection of patients to the genetic studies. In the genetic part of this thesis we found an association between PD and a polymorphic CAG-repeat in POLG1 gene encoding the catalytic subunit of mitochondrial polymerase gamma. The CAG-repeat encodes a polyglutamine tract (polyQ), the two most common lengths of which are 10Q (86-90%) and 11Q. In our Finnish material, the rarer non-10Q or non-11Q length variants (6Q-9Q, 12Q-14Q, 4R+9Q) were more frequent in patients than in spouse controls (10% vs. 3.5 %, p=0.003), or population controls (p=0.001). Therefore, we performed a replication study in 652 North American PD patients and 292 controls. Non-10/11Q alleles were more common in the US PD patients compared to the controls but the difference did not reach statistical significance (p=0.07). This larger data suggested our original definition of variant length allele might need reconsideration. Most previous studies on phenotypic effects of POLG1 polyQ have defined 10Q as the only normal allele. Non-10Q alleles were significantly more common in patients compared to the controls (17.3% vs. 12.3 %, p= 0.005). This association between non-10Q length variants and PD remained significant when compared to a larger set of 1541 literature controls (p=0.00005). In conclusion, POLG1 polyQ alleles other than 10Q may predispose to PD. We did not find association between PD and parkin or DJ-1, genes underlying autosomal recessive parkinsonism. The functional Val158Met polymorphism, which affects the catalytic effect of COMT enzyme, and another coding polymorphism in COMT were not associated with PD in our patient material. The APOE e2/3/4 polymorphism modifies risk for Alzheimer s disease and prognosis of for example brain trauma. APOE promoter and enhancer polymorphisms 219G/T and +113G/C, and APOE e3 haplotypes, have also been shown to modify the risk of Alzheimer s disease but not reported in PD. No association was found between PD and APOE e2/3/4 polymorphism, the promoter or enhancer polymorphisms, or the e3 haplotypes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Childhood-onset mitochondrial diseases comprise a heterogeneous group of disorders, which may manifest with almost any symptom and affect any tissue or organ. Due to challenging diagnostics, most children still lack a specific aetiological diagnosis. The aim of this thesis was to find molecular causes for childhood-onset mitochondrial disorders in Finland. We identified the underlying cause for 25 children, and found three new diseases, which had not been diagnosed in Finland before. These diseases caused severe progressive infantile-onset encephalomyopathies, and were due to defects in mitochondrial DNA (mtDNA) maintenance. Furthermore, the thesis provides the molecular background of Finnish patients with ‘leukoencephalopathy with brain stem and spinal cord involvement and elevated brain lactate’ (LBSL). A new phenotype was identified to be due to mutations in Twinkle, resembling ‘infantile onset spinocerebellar ataxia’ (IOSCA). These mutations caused mtDNA depletion in the liver, thus confirming the essential role of Twinkle in mtDNA maintenance, and expanding the molecular background of mtDNA depletion syndromes. The major aetiology for infantile mitochondrial myopathy in Finland was discovered to be due to mutations in thymidine kinase 2 (TK2). A novel mutation with Finnish ancestry was identified, and a genotype-phenotype correlation with mutation-specific distribution of tissue involvement was found, thus proving that deficient TK2 may cause multi-tissue depletion and impair neuronal function. This work established the molecular diagnosis and advanced the knowledge of phenotypes among paediatric patients with polymerase gamma (POLG) mutations. The patients showed severe early-onset encephalopathy with intractable epilepsy. POLG mutations are not a prevalent cause of children’s ataxias, although ataxia is a major presenting symptom among adults. Our findings indicate that POLG mutations should be investigated even if typical MRI, histochemical or biochemical abnormalities are lacking. LBSL patients showed considerable variation in phenotype despite identical mutations. A common, most likely European, ancestry, and a relative high carrier frequency of these mutations in Finland were discovered; suggesting that LBSL may be a quite common leukoencephalopathy in other populations as well. The results suggest that MRI findings are so unique that the diagnosis of LBSL is possible to make without genetic studies. This thesis work has resulted in identification of new mitochondrial disorders in Finland, enhancing the understanding of the clinical variability and the importance of tissue-specificity of these disorders. In addition to providing specific diagnosis to the patients, these findings give light to the underlying pathogenetic mechanisms of childhood-onset mitochondrial disorders.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fatigue fracture is an overuse injury commonly encountered in military and sports medicine, and known to relate to intensive or recently intensified physical activity. Bone responds to increased stress by enhanced remodeling. If physical stress exceeds bone s capability to remodel, accumulation of microfractures can lead to bone fatigue and stress fracture. Clinical diagnosis of stress fractures is complex and based on patient s anamnesis and radiological imaging. Bone stress fractures are mostly low-risk injuries, healing well after non-operative management, yet, occurring in high-risk areas, stress fractures can progress to displacement, often necessitating surgical treatment and resulting in prolonged morbidity. In the current study, the role of vitamin D as a predisposing factor for fatigue fractures was assessed using serum 25OHD level as the index. The average serum 25OHD concentration was significantly lower in conscripts with fatigue fracture than in controls. Evaluating TRACP-5b bone resorption marker as indicator of fatigue fractures, patients with elevated serum TRACP-5b levels had eight times higher probability of sustaining a stress fracture than controls. Among the 154 patients with exercise induced anterior lower leg pain and no previous findings on plain radiography, MRI revealed a total of 143 bone stress injuries in 86 patients. In 99% of the cases, injuries were in the tibia, 57% in the distal third of the tibial shaft. In patients with injury, forty-nine (57%) patients exhibited bilateral stress injuries. In a 20-year follow-up, the incidence of femoral neck fatigue fractures prior to the Finnish Defence Forces new regimen in 1986 addressing prevention of these fractures was 20.8/100,000, but rose to 53.2/100,000 afterwards, a significant 2.6-fold increase. In nineteen subjects with displaced femoral neck fatigue fractures, ten early local complications (in first postoperative year) were evident, and after the first postoperative year, osteonecrosis of the femoral head in six and osteoarthritis of the hip in thirteen patients were found. It seems likely that low vitamin D levels are related to fatigue fractures, and that an increasing trend exists between TRACP-5b bone resorption marker elevation and fatigue fracture incidence. Though seldom detected by plain radiography, fatigue fractures often underlie unclear lower leg stress-related pain occurring in the distal parts of the tibia. Femoral neck fatigue fractures, when displaced, lead to long-term morbidity in a high percentage of patients, whereas, when non-displaced, they do not predispose patients to subsequent adverse complications. Importantly, an educational intervention can diminish the incidence of fracture displacement by enhancing awareness and providing instructions for earlier diagnosis of fatigue fractures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Technical or contaminated ethanol products are sometimes ingested either accidentally or on purpose. Typical misused products are black-market liquor and automotive products, e.g., windshield washer fluids. In addition to less toxic solvents, these liquids may contain the deadly methanol. Symptoms of even lethal solvent poisoning are often non-specific at the early stage. The present series of studies was carried out to develop a method for solvent intoxication breath diagnostics to speed up the diagnosis procedure conventionally based on blood tests. Especially in the case of methanol ingestion, the analysis method should be sufficiently sensitive and accurate to determine the presence of even small amounts of methanol from the mixture of ethanol and other less-toxic components. In addition to the studies on the FT-IR method, the Dräger 7110 evidential breath analyzer was examined to determine its ability to reveal a coexisting toxic solvent. An industrial Fourier transform infrared analyzer was modified for breath testing. The sample cell fittings were widened and the cell size reduced in order to get an alveolar sample directly from a single exhalation. The performance and the feasibility of the Gasmet FT-IR analyzer were tested in clinical settings and in the laboratory. Actual human breath screening studies were carried out with healthy volunteers, inebriated homeless men, emergency room patients and methanol-intoxicated patients. A number of the breath analysis results were compared to blood test results in order to approximate the blood-breath relationship. In the laboratory experiments, the analytical performance of the Gasmet FT-IR analyzer and Dräger 7110 evidential breath analyzer was evaluated by means of artificial samples resembling exhaled breath. The investigations demonstrated that a successful breath ethanol analysis by Dräger 7110 evidential breath analyzer could exclude any significant methanol intoxication. In contrast, the device did not detect very high levels of acetone, 1-propanol and 2-propanol in simulated breath. The Dräger 7110 evidential breath ethanol analyzer was not equipped to recognize the interfering component. According to the studies the Gasmet FT-IR analyzer was adequately sensitive, selective and accurate for solvent intoxication diagnostics. In addition to diagnostics, the fast breath solvent analysis proved feasible for controlling the ethanol and methanol concentration during haemodialysis treatment. Because of the simplicity of the sampling and analysis procedure, non-laboratory personnel, such as police officers or social workers, could also operate the analyzer for screening purposes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A low temperature polyol process, based on glycolaldehyde mediated partial reduction of FeCl3 center dot 6H(2)O at 120 degrees C in the presence of sodium acetate as an alkali source and 2,2'-(ethylenedioxy)-bis-(ethylamine) as an electrostatic stabilizer has been used for the gram-scale preparation of biocompatible, water-dispersible, amine functionalized magnetite nanoparticles (MNPs) with an average diameter of 6 +/- 0.75 nm. With a reasonably high magnetization (37.8 e.m.u.) and amine groups on the outer surface of the nanoparticles, we demonstrated the magnetic separation and concentration implications of these ultrasmall particles in immunoassay. MRI studies indicated that these nanoparticles had the desired relaxivity for T-2 contrast enhancement in vivo. In vitro biocompatibility, cell uptake and MR imaging studies established that these nanoparticles were safe in clinical dosages and by virtue of their ultrasmall sizes and positively charged surfaces could be easily internalized by cancer cells. All these positive attributes make these functional nanoparticles a promising platform for further in vitro and in vivo evaluations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Enhanced Scan design can significantly improve the fault coverage for two pattern delay tests at the cost of exorbitantly high area overhead. The redundant flip-flops introduced in the scan chains have traditionally only been used to launch the two-pattern delay test inputs, not to capture tests results. This paper presents a new, much lower cost partial Enhanced Scan methodology with both improved controllability and observability. Facilitating observation of some hard to observe internal nodes by capturing their response in the already available and underutilized redundant flip-flops improves delay fault coverage with minimal or almost negligible cost. Experimental results on ISCAS'89 benchmark circuits show significant improvement in TDF fault coverage for this new partial enhance scan methodology.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Automatic identification of software faults has enormous practical significance. This requires characterizing program execution behavior and the use of appropriate data mining techniques on the chosen representation. In this paper, we use the sequence of system calls to characterize program execution. The data mining tasks addressed are learning to map system call streams to fault labels and automatic identification of fault causes. Spectrum kernels and SVM are used for the former while latent semantic analysis is used for the latter The techniques are demonstrated for the intrusion dataset containing system call traces. The results show that kernel techniques are as accurate as the best available results but are faster by orders of magnitude. We also show that latent semantic indexing is capable of revealing fault-specific features.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

It is now realised (1,2,3) that a knowledge of stacking fault energy is fundamental for an understanding of the mechanical behaviour of metals. There are several processes in which the imperfect dislocations have to recombine locally to form an unextended dislocation . For intersection of two dislocations it is, for example, necessary to form 'constrictions'. Cross slip of extended dislocations also involves constriction. The onset of stage llI work hardening in a crystal with close-packed structure is attributed to cross slip and hence is controlled by the stacking fault energy (SPE). Methods of estimation of SFE are based on either the direct observation of stacking faults in an electron microscope or their effects on the deformation processes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a new approach to the location of fault in the high voltage power transmission system using Support Vector Machines (SVMs). A knowledge base is developed using transient stability studies for apparent impedance swing trajectory in the R-X plane. SVM technique is applied to identify the fault location in the system. Results are presented on sample 3-power station, a 9-bus system illustrate the implementation of the proposed method.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents an Artificial Neural Network (ANN) approach for locating faults in distribution systems. Different from the traditional Fault Section Estimation methods, the proposed approach uses only limited measurements. Faults are located according to the impedances of their path using a Feed Forward Neural Networks (FFNN). Various practical situations in distribution systems, such as protective devices placed only at the substation, limited measurements available, various types of faults viz., three-phase, line (a, b, c) to ground, line to line (a-b, b-c, c-a) and line to line to ground (a-b-g, b-c-g, c-a-g) faults and a wide range of varying short circuit levels at substation, are considered for studies. A typical IEEE 34 bus practical distribution system with unbalanced loads and with three- and single- phase laterals and a 69 node test feeder with different configurations are considered for studies. The results presented show that the proposed approach of fault location gives close to accurate results in terms of the estimated fault location.