652 resultados para Crutch transducer


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Dissertação para obtenção do grau de Mestre em Engenharia Eletrotécnica Ramo de Automação e eletrónica Industrial

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Human epidermal growth factor receptor 2 (HER2) is a breast cancer biomarker that plays a major role in promoting breast cancer cell proliferation and malignant growth. The extracellular domain (ECD) of HER2 can be shed into the blood stream and its concentration is measurable in the serum fraction of blood. In this work an electrochemical immunosensor for the analysis of HER2 ECD in human serum samples was developed. To achieve this goal a screen-printed carbon electrode, modified with gold nanoparticles, was used as transducer surface. A sandwich immunoassay, using two monoclonal antibodies, was employed and the detection of the antibody–antigen interaction was performed through the analysis of an enzymatic reaction product by linear sweep voltammetry. Using the optimized experimental conditions the calibration curve (ip vs. log[HER2 ECD]) was established between 15 and 100 ng/mL and a limit of detection (LOD) of 4.4 ng/mL was achieved. These results indicate that the developed immunosensor could be a promising tool in breast cancer diagnostics, patient follow-up and monitoring of metastatic breast cancer since it allows quantification in a useful concentration range and has an LOD below the established cut-off value (15 ng/mL).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Nos últimos anos, o processo de ensino e aprendizagem tem sofrido significativas alterações graças ao aparecimento da Internet. Novas ferramentas para apoio ao ensino têm surgido, nas quais se destacam os laboratórios remotos. Atualmente, muitas instituições de ensino disponibilizam laboratórios remotos nos seus cursos, que permitem, a professores e alunos, a realização de experiências reais através da Internet. Estes são implementados por diferentes arquiteturas e infraestruturas, suportados por vários módulos de laboratório acessíveis remotamente (e.g. instrumentos de medição). No entanto, a sua inclusão no ensino é ainda deficitária, devido: i) à falta de meios e competências técnicas das instituições de ensino para os desenvolverem, ii) à dificuldade na partilha dos módulos de laboratório por diferentes infraestruturas e, iii) à reduzida capacidade de os reconfigurar com esses módulos. Para ultrapassar estas limitações, foi idealizado e desenvolvido no âmbito de um trabalho de doutoramento [1] um protótipo, cuja arquitetura é baseada na norma IEEE 1451.0 e na tecnologia de FPGAs. Para além de garantir o desenvolvimento e o acesso de forma normalizada a um laboratório remoto, este protótipo promove ainda a partilha de módulos de laboratório por diferentes infraestruturas. Nesse trabalho explorou-se a capacidade de reconfiguração de FPGAs para embutir na infraestrutura do laboratório vários módulos, todos descritos em ficheiros, utilizando linguagens de descrição de hardware estruturados de acordo com a norma IEEE 1451.0. A definição desses módulos obriga à criação de estruturas de dados binárias (Transducer Electronic Data Sheets, TEDSs), bem como de outros ficheiros que possibilitam a sua interligação com a infraestrutura do laboratório. No entanto, a criação destes ficheiros é bastante complexa, uma vez que exige a realização de vários cálculos e conversões. Tendo em consideração essa mesma complexidade, esta dissertação descreve o desenvolvimento de uma aplicação Web para leitura e escrita dos TEDSs. Para além de um estudo sobre os laboratórios remotos, é efetuada uma descrição da norma IEEE 1451.0, com particular atenção para a sua arquitetura e para a estrutura dos diferentes TEDSs. Com o objetivo de enquadrar a aplicação desenvolvida, efetua-se ainda uma breve apresentação de um protótipo de um laboratório remoto reconfigurável, cuja reconfiguração é apoiada por esta aplicação. Por fim, é descrita a verificação da aplicação Web, de forma a tirar conclusões sobre o seu contributo para a simplificação dessa reconfiguração.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Os osciloscópios digitais são utilizados em diversas áreas do conhecimento, assumindo-se no âmbito da engenharia electrónica, como instrumentos indispensáveis. Graças ao advento das Field Programmable Gate Arrays (FPGAs), os instrumentos de medição reconfiguráveis, dadas as suas vantagens, i.e., altos desempenhos, baixos custos e elevada flexibilidade, são cada vez mais uma alternativa aos instrumentos tradicionalmente usados nos laboratórios. Tendo como objectivo a normalização no acesso e no controlo deste tipo de instrumentos, esta tese descreve o projecto e implementação de um osciloscópio digital reconfigurável baseado na norma IEEE 1451.0. Definido de acordo com uma arquitectura baseada nesta norma, as características do osciloscópio são descritas numa estrutura de dados denominada Transducer Electronic Data Sheet (TEDS), e o seu controlo é efectuado utilizando um conjunto de comandos normalizados. O osciloscópio implementa um conjunto de características e funcionalidades básicas, todas verificadas experimentalmente. Destas, destaca-se uma largura de banda de 575kHz, um intervalo de medição de 0.4V a 2.9V, a possibilidade de se definir um conjunto de escalas horizontais, o nível e declive de sincronismo e o modo de acoplamento com o circuito sob análise. Arquitecturalmente, o osciloscópio é constituído por um módulo especificado com a linguagem de descrição de hardware (HDL, Hardware Description Language) Verilog e por uma interface desenvolvida na linguagem de programação Java®. O módulo é embutido numa FPGA, definindo todo o processamento do osciloscópio. A interface permite o seu controlo e a representação do sinal medido. Durante o projecto foi utilizado um conversor Analógico/Digital (A/D) com uma frequência máxima de amostragem de 1.5MHz e 14 bits de resolução que, devido às suas limitações, obrigaram à implementação de um sistema de interpolação multi-estágio com filtros digitais.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

O cancro é uma das principais causas de morte em todo o mundo. Entre as mulheres, o cancro da mama é o mais frequente. A deteção precoce do cancro é de extrema importância na medida em que pode aumentar as possibilidades de cura dos pacientes e contribuir para a diminuição da taxa de mortalidade desta doença. Um método que tem contribuído para a deteção precoce do cancro é a análise de biomarcadores. Biomarcadores associados ao cancro da mama, como o Recetor 2 do Fator de Crescimento Epidérmico Humano (HER2) e o Antigénio Carbohidratado 15-3 (CA 15-3), podem ser detetados através de dispositivos como os biossensores. Neste trabalho foram desenvolvidos dois imunossensores eletroquímicos para a análise de HER2 e CA 15-3. Para ambos os sensores foram utilizados, como transdutores, elétrodos serigrafados de carbono. A superfície destes transdutores foi nanoestruturada com nanopartículas de ouro. Foram realizados imunoensaios não-competitivos (do tipo sandwich) em ambos os imunossensores, cuja estratégia consistiu na (i) imobilização do respetivo anticorpo de captura na superfície nanoestruturada dos elétrodos, (ii) bloqueio da superfície com caseína, (iii) incubação com uma mistura do analito (HER2 ou CA 15-3) e o respetivo anticorpo de deteção biotinilado, (iv) adição de estreptavidina conjugada com fosfatase alcalina (S-AP; a AP foi utilizada como marcador enzimático), (v) adição de uma mistura do substrato enzimático (3-indoxil fosfato) e nitrato de prata, e (vi) deteção do sinal analítico através da redissolução anódica, por voltametria de varrimento linear, da prata depositada enzimaticamente. Com as condições experimentais otimizadas, foi estabelecida a curva de calibração para a análise de HER2 em soro, entre 15 e 100 ng/mL, obtendo-se um limite de deteção de 4,4 ng/mL. Para o CA 15-3 a curva de calibração (em solução aquosa) foi estabelecida entre 15 e 250 U/mL, obtendo-se um limite de deteção de 37,5 U/mL. Tendo em conta o valor limite (cutoff value) estabelecido para o HER2 (15 ng/mL) pode-se comprovar a possível utilidade do imunossensor desenvolvido para o diagnóstico precoce e descentralizado do cancro da mama. No caso do CA 15-3 serão necessários estudos adicionais para se poder avaliar a utilidade do imunossensor para o diagnóstico do cancro da mama.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Ammonia is an important gas in many power plants and industrial processes so its detection is of extreme importance in environmental monitoring and process control due to its high toxicity. Ammonia’s threshold limit is 25 ppm and the exposure time limit is 8 h, however exposure to 35 ppm is only secure for 10 min. In this work a brief introduction to ammonia aspects are presented, like its physical and chemical properties, the dangers in its manipulation, its ways of production and its sources. The application areas in which ammonia gas detection is important and needed are also referred: environmental gas analysis (e.g. intense farming), automotive-, chemical- and medical industries. In order to monitor ammonia gas in these different areas there are some requirements that must be attended. These requirements determine the choice of sensor and, therefore, several types of sensors with different characteristics were developed, like metal oxides, surface acoustic wave-, catalytic-, and optical sensors, indirect gas analyzers, and conducting polymers. All the sensors types are described, but more attention will be given to polyaniline (PANI), particularly to its characteristics, syntheses, chemical doping processes, deposition methods, transduction modes, and its adhesion to inorganic materials. Besides this, short descriptions of PANI nanostructures, the use of electrospinning in the formation of nanofibers/microfibers, and graphene and its characteristics are included. The created sensor is an instrument that tries to achieve a goal of the medical community in the control of the breath’s ammonia levels being an easy and non-invasive method for diagnostic of kidney malfunction and/or gastric ulcers. For that the device should be capable to detect different levels of ammonia gas concentrations. So, in the present work an ammonia gas sensor was developed using a conductive polymer composite which was immobilized on a carbon transducer surface. The experiments were targeted to ammonia measurements at ppb level. Ammonia gas measurements were carried out in the concentration range from 1 ppb to 500 ppb. A commercial substrate was used; screen-printed carbon electrodes. After adequate surface pre-treatment of the substrate, its electrodes were covered by a nanofibrous polymeric composite. The conducting polyaniline doped with sulfuric acid (H2SO4) was blended with reduced graphene oxide (RGO) obtained by wet chemical synthesis. This composite formed the basis for the formation of nanofibers by electrospinning. Nanofibers will increase the sensitivity of the sensing material. The electrospun PANI-RGO fibers were placed on the substrate and then dried at ambient temperature. Amperometric measurements were performed at different ammonia gas concentrations (1 to 500 ppb). The I-V characteristics were registered and some interfering gases were studied (NO2, ethanol, and acetone). The gas samples were prepared in a custom setup and were diluted with dry nitrogen gas. Electrospun nanofibers of PANI-RGO composite demonstrated an enhancement in NH3 gas detection when comparing with only electrospun PANI nanofibers. Was visible higher range of resistance at concentrations from 1 to 500 ppb. It was also observed that the sensor had stable, reproducible and recoverable properties. Moreover, it had better response and recovery times. The new sensing material of the developed sensor demonstrated to be a good candidate for ammonia gas determination.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Empreendimentos industriais requerem o acompanhamento completo e preciso de dados de máquinas em tempo real, integrando as atividades do chão de fábrica com a engenharia, suporte e negócios. É reconhecido que sistemas de monitorização são fundamentais para melhorar a qualidade do produto, reduzir os tempos e para a adaptação rápida às mudanças de produção. Os sensores de processos possuem custos altos, não são compactos e são de difícil implementação. Portanto, seria estratégico desenvolver sistemas de monitorização que usufruem ao máximo dos recursos já existentes nas máquinas e ferramentas e que não representem custos adicionais elevados e de difícil implementação. O uso de PLC nas indústrias é crescente. Estes mostram-se como ferramentas potenciais para atender a estas exigências. Os PLC possuem os recursos necessários para a aquisição de informações e controlo das máquinas, facilitando a interação com um sistema SCADA. O objetivo do presente trabalho é pesquisar soluções sobre sistemas de monitorização que possam substituir um sistema instalado antiquado e encontrar uma solução para o controlo de um processo de vazamento. Para tal, foram consideradas duas soluções: uma passaria por desenvolver um sistema de monitorização que controlasse o processo de vazamento, e outra que permitisse ser o PLC a fazer o controlo, adquirindo um HMI apenas para monitorização. Esta última solução revelou-se como a melhor, visto que um PLC tem mais durabilidade em relação a um PC, em termos de atualizações de hardware e software. Assim, foram criadas funções no PLC para fazer o controlo de vazamento e foi adquirido uma consola Beijer, e respetivo software de programação SCADA, para a criação do sistema de monitorização. Os resultados mostram que o PLC é capaz de executar o controlo, não sendo necessário investir em PC que são mais caros, bastando para isso adquirir sistemas SCADA simples e capazes.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A gold nanoparticle-coated screen-printed carbon electrode was used as the transducer in the development of an electrochemical immunosensor for Ara h 1 (a major peanut allergen) detection in food samples. Gold nanoparticles (average diameter=32 nm) were electrochemically generated on the surface of screen-printed carbon electrodes. Two monoclonal antibodies were used in a sandwich-type immunoassay and the antibody–antigen interaction was electrochemically detected through stripping analysis of enzymatically (using alkaline phosphatase) deposited silver. The total time of the optimized immunoassay was 3 h 50 min. The developed immunosensor allowed the quantification of Ara h 1 between 12.6 and 2000 ng/ml, with a limit of detection of 3.8 ng/ml, and provided precise (RSD <8.7%) and accurate (recovery >96.6%) results. The immunosensor was successfully applied to the analysis of complex food matrices (cookies and chocolate), being able to detect Ara h 1 in samples containing 0.1% of peanut.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this thesis a piezoelectric energy harvesting system, responsible for regulating the power output of a piezoelectric transducer subjected to ambient vibration, is designed to power an RF receiver with a 6 mW power consump-tion. The electrical characterisation of the chosen piezoelectric transducer is the starting point of the design, which subsequently presents a full-bridge cross-coupled rectifier that rectifies the AC output of the transducer and a low-dropout regulator responsible for delivering a constant voltage system output of 0.6 V, with low voltage ripple, which represents the receiver’s required sup-ply voltage. The circuit is designed using CMOS 130 nm UMC technology, and the system presents an inductorless architecture, with reduced area and cost. The electrical simulations run for the complete circuit lead to the conclusion that the proposed piezoelectric energy harvesting system is a plausible solution to power the RF receiver, provided that the chosen transducer is subjected to moderate levels of vibration.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In an underwater environment it is difficult to implement solutions for wireless communications. The existing technologies using electromagnetic waves or lasers are not very efficient due to the large attenuation in the aquatic environment. Ultrasound reveals a lower attenuation, and thus has been used in underwater long-distance communications. The much slower speed of acoustic propagation in water (about 1500 m/s) compared with that of electromagnetic and optical waves, is another limiting factor for efficient communication and networking. For high data-rates and real-time applications it is necessary to use frequencies in the MHz range, allowing communication distances of hundreds of meters with a delay of milliseconds. To achieve this goal, it is necessary to develop ultrasound transducers able to work at high frequencies and wideband, with suitable responses to digital modulations. This work shows how the acoustic impedance influences the performance of an ultrasonic emitter transducer when digital modulations are used and operating at frequencies between 100 kHz and 1 MHz. The study includes a Finite Element Method (FEM) and a MATLAB/Simulink simulation with an experimental validation to evaluate two types of piezoelectric materials: one based on ceramics (high acoustic impedance) with a resonance design and the other based in polymer (low acoustic impedance) designed to optimize the performance when digital modulations are used. The transducers performance for Binary Amplitude Shift Keying (BASK), On-Off Keying (OOK), Binary Phase Shift Keying (BPSK) and Binary Frequency Shift Keying (BFSK) modulations with a 1 MHz carrier at 125 kbps baud rate are compared.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Tese de Doutoramento (Programa Doutoral em Engenharia Biomédica)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate echocardiography accuracy in performing and obtaining images for dynamical three-dimensional (3D) reconstruction. METHODS: Three-dimensional (3D) image reconstruction was obtained in 20 consecutive patients who underwent transesophageal echocardiography. A multiplanar 5 MHz transducer was used for 3D reconstruction. RESULTS: Twenty patients were studied consecutively. The following cardiac diseases were present: valvar prostheses-6 (2 mitral, 2 aortic and 2 mitral and aortic); mitral valve prolapse- 3; mitral and aortic disease - 2; aortic valve disease- 5; congenital heart disease- 3 (2 atrial septal defect- ASD - and 1 transposition of the great arteries -TGA); arteriovenous fistula- 1. In 7 patients, color Doppler was also obtained and used for 3D flow reconstruction. Twenty five cardiac structures were acquired and 60 reconstructions generated (28 of mitral valves, 14 of aortic valves, 4 of mitral prostheses, 7 of aortic prostheses and 7 of the ASD). Fifty five of 60 (91.6%) reconstructions were considered of good quality by 2 independent observers. The 11 reconstructed mitral valves/prostheses and the 2 reconstructed ASDs provided more anatomical information than two dimensional echocardiography (2DE) alone. CONCLUSION: 3D echocardiography using a transesophageal transducer is a feasible technique, which improves detection of anatomical details of cardiac structures, particularly of the mitral valve and atrial septum.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Tese de Doutoramento em Ciência e Engenharia de Polímeros e Compósitos.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Report for the scientific sojourn at the Department of Micro and Nanotechnology of the Technical University of Denmark from August until December 2006. The research was focused on designing and carrying out a technological process for fabricating high frequency resonators with dielectric solid transducer gaps.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The pineal gland functions as a neuroendocrine transducer that coordinate the organism response to changing environmental stimuli such as light and temperature. The main and best known pineal neurohormone is melatonin that is synthesized and released in a circadian fashion with a peak during the night darkness hours. We have recently reported that melatonin exerts important immuno regulatory functions. Here we describe the astonishing property of exogenous melatonin which is able to counteract completely the depressive effect of anxiety-restraint stress and/or of corticosterone on thymus weight, andibody production and antiviral responses. This effect seems to be mediated by antigen-activated T cells via an opiatergic mechanism.