3 resultados para Crutch transducer

em CaltechTHESIS


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The major objective of the study has been to investigate in detail the rapidly-varying peak uplift pressure and the slowly-varying positive and negative uplift pressures that are known to be exerted by waves against the underside of a horizontal pier or platform located above the still water level, but not higher than the crests of the incident waves.

In a "two-dimensional" laboratory study conducted in a 100-ft long by 15-in.-wide by 2-ft-deep wave tank with a horizontal smooth bottom, individually generated solitary waves struck a rigid, fixed, horizontal platform extending the width of the tank. Pressure transducers were mounted flush with the smooth soffit, or underside, of the platform. The location of the transducers could be varied.

The problem of a d equate dynamic and spatial response of the transducers was investigated in detail. It was found that unless the radius of the sensitive area of a pressure transducer is smaller than about one-third of the characteristic width of the pressure distribution, the peak pressure and the rise-time will not be recorded accurately. A procedure was devised to correct peak pressures and rise-times for this transducer defect.

The hydrodynamics of the flow beneath the platform are described qualitatively by a si1nple analysis, which relates peak pressure and positive slowly-varying pressure to the celerity of the wave front propagating beneath the platform, and relates negative slowly-varying pressure to the process by which fluid recedes from the platform after the wave has passed. As the wave front propagates beneath the platform, its celerity increases to a maximum, then decreases. The peak pressure similarly increases with distance from the seaward edge of the platform, then decreases.

Measured peak pressure head, always found to be less than five times the incident wave height above still water level, is an order of magnitude less than reported shock pressures due to waves breaking against vertical walls; the product of peak pressure and rise-time, considered as peak impulse, is of the order of 20% of reported shock impulse due to waves breaking against vertical walls. The maximum measured slowly-varying uplift pressure head is approximately equal to the incident wave height less the soffit clearance above still water level. The normalized magnitude and duration of negative pressure appears to depend principally on the ratio of soffit clearance to still water depth and on the ratio of platform length to still water depth.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This thesis has two basic themes: the investigation of new experiments which can be used to test relativistic gravity, and the investigation of new technologies and new experimental techniques which can be applied to make gravitational wave astronomy a reality.

Advancing technology will soon make possible a new class of gravitation experiments: pure laboratory experiments with laboratory sources of non-Newtonian gravity and laboratory detectors. The key advance in techno1ogy is the development of resonant sensing systems with very low levels of dissipation. Chapter 1 considers three such systems (torque balances, dielectric monocrystals, and superconducting microwave resonators), and it proposes eight laboratory experiments which use these systems as detectors. For each experiment it describes the dominant sources of noise and the technology required.

The coupled electro-mechanical system consisting of a microwave cavity and its walls can serve as a gravitational radiation detector. A gravitational wave interacts with the walls, and the resulting motion induces transitions from a highly excited cavity mode to a nearly unexcited mode. Chapter 2 describes briefly a formalism for analyzing such a detector, and it proposes a particular design.

The monitoring of a quantum mechanical harmonic oscillator on which a classical force acts is important in a variety of high-precision experiments, such as the attempt to detect gravitational radiation. Chapter 3 reviews the standard techniques for monitoring the oscillator; and it introduces a new technique which, in principle, can determine the details of the force with arbitrary accuracy, despite the quantum properties of the oscillator.

The standard method for monitoring the oscillator is the "amplitude- and-phase" method (position or momentum transducer with output fed through a linear amplifier). The accuracy obtainable by this method is limited by the uncertainty principle. To do better requires a measurement of the type which Braginsky has called "quantum nondemolition." A well-known quantum nondemolition technique is "quantum counting," which can detect an arbitrarily weak force, but which cannot provide good accuracy in determining its precise time-dependence. Chapter 3 considers extensively a new type of quantum nondemolition measurement - a "back-action-evading" measurement of the real part X1 (or the imaginary part X2) of the oscillator's complex amplitude. In principle X1 can be measured arbitrarily quickly and arbitrarily accurately, and a sequence of such measurements can lead to an arbitrarily accurate monitoring of the classical force.

Chapter 3 describes explicit gedanken experiments which demonstrate that X1 can be measured arbitrarily quickly and arbitrarily accurately, it considers approximate back-action-evading measurements, and it develops a theory of quantum nondemolition measurement for arbitrary quantum mechanical systems.

In Rosen's "bimetric" theory of gravity the (local) speed of gravitational radiation vg is determined by the combined effects of cosmological boundary values and nearby concentrations of matter. It is possible for vg to be less than the speed of light. Chapter 4 shows that emission of gravitational radiation prevents particles of nonzero rest mass from exceeding the speed of gravitational radiation. Observations of relativistic particles place limits on vg and the cosmological boundary values today, and observations of synchrotron radiation from compact radio sources place limits on the cosmological boundary values in the past.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This thesis presents investigations of chemical reactions occurring at the liquid/vapor interface studied using novel sampling methodologies coupled with detection by mass spectrometry. Chapters 2 and 3 utilize the recently developed technique of field-induced droplet ionization mass spectrometry (FIDI-MS), in which the application of a strong electric field to a pendant microliter droplet results in the ejection of highly charged progeny droplets from the liquid surface. In Chapter 2, this method is employed to study the base-catalyzed dissociation of a surfactant molecule at the liquid/vapor interface upon uptake of ammonia from the gas phase. This process is observed to occur without significant modulation of the bulk solution pH, suggesting a transient increase in surface pH following the uptake of gaseous ammonia. Chapter 3 presents real-time studies of the oxidation of the model tropospheric organic compound glycolaldehyde by photodissociation of iron (III) oxalate complexes. The oxidation products of glycolaldehyde formed in this process are identified, and experiments in a deoxygenated environment identify the role of oxygen in the oxidation pathway and in the regeneration of iron (III) following photo-initiated reduction. Chapter 4 explores alternative methods for the study of heterogeneous reaction processes by mass spectrometric sampling from liquid surfaces. Bursting bubble ionization (BBI) and interfacial sampling with an acoustic transducer (ISAT) generate nanoliter droplets from a liquid surface that can be sampled via the atmospheric pressure interface of a mass spectrometer. Experiments on the oxidation of oleic acid by ozone using ISAT are also presented. Chapters 5 and 6 detail mechanistic studies and applications of free-radical-initiated peptide sequencing (FRIPS), a technique employing gas-phase free radical chemistry to the sequencing of peptides and proteins by mass spectrometry. Chapter 5 presents experimental and theoretical studies on the anomalous mechanism of dissociation observed in the presence of serine and threonine residues in peptides. Chapter 6 demonstrates the combination of FRIPS with ion mobility-mass spectrometry (IM-MS) for the separation of isomeric peptides.