973 resultados para Council on Environmental Quality (U.S.)


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: In Angola, malaria is an endemic disease having a major impact on the economy. The WHO recommends testing for all suspected malaria cases, to avoid the presumptive treatment of this disease. In malaria endemic regions laboratory technicians must be very comfortable with microscopy, the golden standard for malaria diagnosis, to avoid the incorrect diagnosis. The improper use of medication promotes drug resistance and undesirable side effects. The present study aims to assess the impact of a three-day refresher course on the knowledge of technicians, quality of blood smears preparation and accuracy of microscopy malaria diagnosis, using qPCR as reference method. Methods: This study was implemented in laboratories from three hospitals in different provinces of Angola: Bengo, Benguela and Luanda. In each laboratory samples were collected before and after the training course (slide with thin and thick blood smears, a dried blood spot and a form). The impact of the intervention was evaluated through a written test, the quality of slide preparation and the performance of microscopy. Results: It was found a significant increase on the written test median score, from 52.5% to 65.0%. A total of 973 slides were analysed to evaluate the quality of thick and thin blood smears. Considering all laboratories there was a significant increase in quality of thick and thin blood smears. To determine the performance of microscopy using qPCR as the reference method we used 1,028 samples. Benguela presented the highest values for specificity, 92.9% and 98.8% pre and post-course, respectively and for sensitivity the best pre-course was Benguela (75.9%) and post-course Luanda (75.0%). However, no significant increase in sensitivity and specificity after the training course was registered in any laboratory analysed. Discussion: The findings of this study support the need of continuous refresher training for microscopists and other laboratory staff. The laboratories should have a quality control programme to supervise the diagnosis and also to assess the periodicity of new training. However, other variables needed to be considered to have a correct malaria diagnosis, such as adequate equipment and reagents for staining and visualization, good working conditions, motivated and qualified personnel.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Computed tomography (CT) is one of the most used modalities for diagnostics in paediatric populations, which is a concern as it also delivers a high patient dose. Research has focused on developing computer algorithms that provide better image quality at lower dose. The iterative reconstruction algorithm Sinogram-Affirmed Iterative Reconstruction (SAFIRE) was introduced as a new technique that reduces noise to increase image quality. Purpose: The aim of this study is to compare SAFIRE with the current gold standard, Filtered Back Projection (FBP), and assess whether SAFIRE alone permits a reduction in dose while maintaining image quality in paediatric head CT. Methods: Images were collected using a paediatric head phantom using a SIEMENS SOMATOM PERSPECTIVE 128 modulated acquisition. 54 images were reconstructed using FBP and 5 different strengths of SAFIRE. Objective measures of image quality were determined by measuring SNR and CNR. Visual measures of image quality were determined by 17 observers with different radiographic experiences. Images were randomized and displayed using 2AFC; observers scored the images answering 5 questions using a Likert scale. Results: At different dose levels, SAFIRE significantly increased SNR (up to 54%) in the acquired images compared to FBP at 80kVp (5.2-8.4), 110kVp (8.2-12.3), 130kVp (8.8-13.1). Visual image quality was higher with increasing SAFIRE strength. The highest image quality was scored with SAFIRE level 3 and higher. Conclusion: The SAFIRE algorithm is suitable for image noise reduction in paediatric head CT. Our data demonstrates that SAFIRE enhances SNR while reducing noise with a possible reduction of dose of 68%.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: This study aims to investigate the influence of tube potential (kVp) variation in relation to perceptual image quality and effective dose for pelvis using automatic exposure control (AEC) and non-AEC in a computed radiography (CR) system. Methods and Materials: To determine the effects of using AEC and non-AEC by applying the 10 kVp rule in two experiments using an anthropomorphic pelvis phantom. Images were acquired using 10 kVp increments (60-120 kVp) for both experiments. The first experiment, based on seven AEC combinations, produced 49 images. The mean mAs from each kVp increment were used as a baseline for the second experiment producing 35 images. A total of 84 images were produced and a panel of 5 experienced observers participated for the image scoring using the 2 AFC visual grading software. PCXMC software was used to estimate the effective dose. Results: A decrease in perceptual image quality as the kVp increases was observed both in non-AEC and AEC experiments, however no significant statistical differences (p> 0.05) were found. Image quality scores from all observers at 10 kVp increments for all mAs values using non-AEC mode demonstrates a better score up to 90 kVp. Effective dose results show a statistical significant decrease (p=0.000) on the 75th quartile from 0.3 mSv at 60 kVp to 0.1 mSv at 120 kVp when applying the 10 kVp rule in non-AEC mode. Conclusion: No significant reduction in perceptual image quality is observed when increasing kVp whilst a marked and significant effective dose reduction is observed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Dissertação apresentada como requisito parcial para obtenção do grau de Mestre em Estatística e Gestão de Informação

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Dissertação para obtenção do Grau de Mestre em Engenharia do Ambiente Perfil Gestão de Sistemas Ambientais

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A Work Project, presented as part of the requirements for the Award of a Masters Degree in Management from the NOVA – School of Business and Economics

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A Work Project, presented as part of the requirements for the Award of a Masters Degree in Finance from the NOVA – School of Business and Economics and Maastricht University School of Business and Economics

Relevância:

100.00% 100.00%

Publicador:

Resumo:

ABSTRACT: In order to evaluate the one-year evolution of web-based information on alcohol dependence, we re-assessed alcohol-related sites in July 2007 with the same evaluating tool that had been used to assess these sites in June 2006. Websites were assessed with a standardized form designed to rate sites on the basis of accountability, presentation, interactivity, readability, and content quality. The DISCERN scale was also used, which aimed to assist persons without content expertise in assessing the quality of written health publications. Scores were highly stable for all components of the form one year later (r = .77 to .95, p < .01). Analysis of variance for repeated measures showed no time effect, no interaction between time and scale, no interaction between time and group (affiliation categories), and no interaction between time, group, and scale. The study highlights lack of change of alcohol-dependence-related web pages across one year.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This Communication Strategy has been developed by representatives of the statutory sector and Non-Governmental Organisations (NGOs) from the voluntary and community sectors from both Northern Ireland and the Republic of Ireland

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The effect of copper (Cu) filtration on image quality and dose in different digital X-ray systems was investigated. Two computed radiography systems and one digital radiography detector were used. Three different polymethylmethacrylate blocks simulated the pediatric body. The effect of Cu filters of 0.1, 0.2, and 0.3 mm thickness on the entrance surface dose (ESD) and the corresponding effective doses (EDs) were measured at tube voltages of 60, 66, and 73 kV. Image quality was evaluated in a contrast-detail phantom with an automated analyzer software. Cu filters of 0.1, 0.2, and 0.3 mm thickness decreased the ESD by 25-32%, 32-39%, and 40-44%, respectively, the ranges depending on the respective tube voltages. There was no consistent decline in image quality due to increasing Cu filtration. The estimated ED of anterior-posterior (AP) chest projections was reduced by up to 23%. No relevant reduction in the ED was noted in AP radiographs of the abdomen and pelvis or in posterior-anterior radiographs of the chest. Cu filtration reduces the ESD, but generally does not reduce the effective dose. Cu filters can help protect radiosensitive superficial organs, such as the mammary glands in AP chest projections.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

National Council on Ageing and Older People – Annual Report 2008 2008 was a year of change for the National Council on Ageing and Older People. In January the Government announced the establishment of the Office for Older People at the Department of Health and Children and that the Office would have a key role in progressing the Governmentâ?Ts agenda for older people. The decision provided that Council staff would be transferred to the Office and that the Council would be replaced by an Advisory Council. Although a sad day for the Council itself, we regard this as a significant step forward in bringing older peopleâ?Ts issues right to the centre of Government policy-making. Click here to download PDF 333kb