979 resultados para Clinical consumption materials


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this study was to compare clinical and radiological outcome of lateral condyle fracture of the elbow in children treated with bioabsorbable or metallic material. From January 2008 to December 2009, 16 children with similar fractures and ages were grouped according to the fixation material used. Children were seen at 3, 6, and 12 months and more than 4 years (mean 51.8 months) postoperatively. The clinical results were compared using the Mayo Elbow Performance Score (MEPS). Radiographic studies of the fractured and opposite elbow were assessed at last follow-up control. Twelve children had a sufficient followup and could be included in the study. Seven could be included in the traditional group and 5 in the bioabsorbable group. At 12 months, the MEPS was 100 for every child in both groups. Asymptomatic bony radiolucent visible tracks and heterotopic ossifications were noted in both groups. There were no significant differences in terms of clinical and radiological outcome between the two groups. The use of bioabsorbable pins or screws is a reasonable alternative to the traditional use of metallic materials for the treatment of lateral condyle fracture of the elbow in children.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

INTRODUCTION: Eddy currents induced by switching of magnetic field gradients can lead to distortions in short echo-time spectroscopy or diffusion weighted imaging. In small bore magnets, such as human head-only systems, minimization of eddy current effects is more demanding because of the proximity of the gradient coil to conducting structures. METHODS: In the present study, the eddy current behavior achievable on a recently installed 7 tesla-68 cm bore head-only magnet was characterized. RESULTS: Residual effects after compensation were shown to be on the same order of magnitude as those measured on two whole body systems (3 and 4.7 T), while using two to three fold increased gradient slewrates.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: To evaluate whether the correlation between in vitro bond strength data and estimated clinical retention rates of cervical restorations after two years depends on pooled data obtained from multicenter studies or single-test data. Materials and Methods: Pooled mean data for six dentin adhesive systems (Adper Prompt L-Pop, Clearfil SE, OptiBond FL, Prime & Bond NT, Single Bond, and Scotchbond Multipurpose) and four laboratory methods (macroshear, microshear, macrotensile and microtensile bond strength test) (Scherrer et al, 2010) were correlated to estimated pooled two-year retention rates of Class V restorations using the same adhesive systems. For bond strength data from a single test institute, the literature search in SCOPUS revealed one study that tested all six adhesive systems (microtensile) and two that tested five of the six systems (microtensile, macroshear). The correlation was determined with a database designed to perform a meta-analysis on the clinical performance of cervical restorations (Heintze et al, 2010). The clinical data were pooled and adjusted in a linear mixed model, taking the study effect, dentin preparation, type of isolation and bevelling of enamel into account. A regression analysis was carried out to evaluate the correlation between clinical and laboratory findings. Results: The results of the regression analysis for the pooled data revealed that only the macrotensile (adjusted R2 = 0.86) and microtensile tests (adjusted R2 = 0.64), but not the shear and the microshear tests, correlated well with the clinical findings. As regards the data from a single-test institute, the correlation was not statistically significant. Conclusion: Macrotensile and microtensile bond strength tests showed an adequate correlation with the retention rate of cervical restorations after two years. Bond strength tests should be carried out by different operators and/or research institutes to determine the reliability and technique sensitivity of the material under investigation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

STATEMENT OF PROBLEM: Wear of methacrylate artificial teeth resulting in vertical loss is a problem for both dentists and patients. PURPOSE: The purpose of this study was to quantify wear of artificial teeth in vivo and to relate it to subject and tooth variables. MATERIAL AND METHODS: Twenty-eight subjects treated with complete dentures received 2 artificial tooth materials (polymethyl methacrylate (PMMA)/double-cross linked PMMA fillers; 35%/59% (SR Antaris DCL, SR Postaris DCL); experimental 48%/46%). At baseline and after 12 months, impressions of the dentures were poured with improved stone. After laser scanning, the casts were superimposed and matched. Maximal vertical loss (mm) and volumetric loss (mm(3)) were calculated for each tooth and log-transformed to reduce variability. Volumetric loss was related to the occlusally active surface area. Linear mixed models were used to study the influence of the factors jaw, tooth, and material on adjusted (residual) wear values (alpha=.05). RESULTS: Due to drop outs (n=5) and unmatchable casts (n=3), 69% of all teeth were analyzed. Volumetric loss had a strong linear relationship to surface area (P<.001); this was less pronounced for vertical loss (P=.004). The factor showing the highest influence was the subject. Wear was tooth dependent (increasing from incisors to molars). However, these differences diminished once the wear rates were adjusted for occlusal area, and only a few remained significant (anterior versus posterior maxillary teeth). Another influencing factor was the age of the subject. CONCLUSIONS: Clinical wear of artificial teeth is higher than previously measured or expected. The presented method of analyzing wear of artificial teeth using a laser-scanning device seemed suitable.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

ETHNOPHARMACOLOGICAL RELEVANCE: "Reverse pharmacology", also called "bedside-to-bench" or "field to pharmacy" approach, is a research process starting with documentation of clinical outcome as observed by patients with different therapeutic regimens. The treatment most significantly associated with cure is selected for future studies: first, clinical safety and efficacy; then in vivo and vitro studies. Some clinical data, i.e. details on patient status and progress, can be collected during ethnobotanical surveys; they will help clinical researchers and, once effectiveness and safety are established, will also help users of traditional medicine make safer and more effective choices. To gather clinical data successfully, ethnopharmacologists need to be backed by an appropriate team of specialists in medicine and epidemiology. Ethnopharmacologists can also gather important data on traditional medicine safety. MATERIALS AND METHODS: The first step is to create a consensus on the meaning of "clinical data", their interest and importance. An understanding of why "a cure is not a proof of effectiveness" is a starting point to avoid faulty interpretation of the clinical observations. RESULTS: Experience showed that, with the "bedside-to-bench" approach, a treatment derived from traditional recipe can be scientifically validated (in terms of safety and effectiveness) with a cost of less than a million euros, thus providing an end-product that is affordable, available and sustainable. CONCLUSIONS: With rigorous clinical study results, medicinal plant users gain the possibility to refine heath strategies. The field surveyor may gain a better relationship with the population, once she/he is seen as bringing information useful for the quality of care in the community.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introduction: We launched an investigator-initiated study (ISRCTN31181395) to evaluate the potential benefit of pharmacokinetic-guided dosage individualization of imatinib for leukaemiapatients followed in public and private sectors. Following approval by the research ethics committee (REC) of the coordinating centre, recruitment throughout Switzerland necessitatedto submit the protocol to 11 cantonal RECs.Materials and Methods: We analysed requirements and evaluation procedures of the 12 RECs with associated costs.Results: 1-18 copies of the dossier, in total 4300 printed pages, were required (printing/posting costs: ~300 CHF) to meet initial requirements. Meeting frequencies of RECs ranged between 2 weeks and 2 months, time from submission to fi rst feedback took 2-75 days. Study approval was obtained from a chairman, a subor the full committee, the evaluation work being invoiced by0-1000 CHF (median: 750 CHF, total: 9200 CHF). While 5 RECs gave immediate approval, the other 6 rose in total 38 queries before study release, mainly related to wording in the patient information, leading to 7 different fi nal versions approved. Submission tasks employed an investigator half-time over about 6 months.Conclusion: While the necessity of clinical research evaluation by independent RECs is undisputed, there is a need of further harmonization and cooperation in evaluation procedures. Current administrative burden is indeed complex, time-consuming and costly. A harmonized electronic application form, preferably compatible with other regulatory bodies and European countries, could increase transparency, improve communication, and encourage academic multi-centre clinical research in Switzerland.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: This study was performed to determine the impact of perfusion and diffusion magnetic resonance imaging (MRI) sequences on patients during treatment of newly diagnosed glioblastoma. Special emphasis has been given to these imaging technologies as tools to potentially anticipate disease progression, as progression-free survival is frequently used as a surrogate endpoint. METHODS AND MATERIALS: Forty-one patients from a phase II temolozomide clinical trial were included. During follow-up, images were integrated 21 to 28 days after radiochemotherapy and every 2 months thereafter. Assessment of scans included measurement of size of lesion on T1 contrast-enhanced, T2, diffusion, and perfusion images, as well as mass effect. Classical criteria on tumor size variation and clinical parameters were used to set disease progression date. RESULTS: A total of 311 MRI examinations were reviewed. At disease progression (32 patients), a multivariate Cox regression determined 2 significant survival parameters: T1 largest diameter (p < 0.02) and T2 size variation (p < 0.05), whereas perfusion and diffusion were not significant. CONCLUSION: Perfusion and diffusion techniques cannot be used to anticipate tumor progression. Decision making at disease progression is critical, and classical T1 and T2 imaging remain the gold standard. Specifically, a T1 contrast enhancement over 3 cm in largest diameter together with an increased T2 hypersignal is a marker of inferior prognosis.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: When we examined a previously published prospective multi-center clinical trial in which complete denture-wearers were followed over a period of 2 years, we found that about 30% of the variability in the clinical wear data of denture teeth was due to unknown characteristics of the subjects. In the second part of the study, we try to identify which patient- and therapy-related factors may explain some of this variability. METHODS: The clinical wear data of denture teeth at different recall times (6, 12, 18, 24 months) in 89 subjects (at baseline) were correlated with the following parameters, which may all have an influence on the wear of denture teeth: age, gender, bruxism as reported by the subjects, number of prostheses used so far, time since last extraction, smoking, fit of dentures as judged by the subject and the clinician, average denture wearing time and wearing of denture during the night. To evaluate the influence of the different patient- and therapy-related variables, both a univariate analysis (one extra factor to the model) and a multivariate analysis were carried out using linear mixed models with the variable Log mean as the outcome. RESULTS: None of the patient- and therapy-related parameters showed a statistically significant effect on the wear of denture teeth. There was, however, a trend for women to show less wear compared to men and a trend of decreasing wear with increasing age. SIGNIFICANCE: Further research is required to identify the factors which are responsible for the high variability observed between the subjects regarding clinical wear data.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introduction: Imatinib trough plasma concentrations (Cmin) have been correlated with treatment response in chronic myeloid leukemia (CML) patients. The use of Cmin monitoring for optimizing imatinib dosage (therapeutic drug monitoring [TDM]) is therefore proposed for patients with unsatisfying response or tolerance ("rescue TDM"). A cycle of "routine TDM" for dosage individualization could also be beneficial to prevent unfavorable events, yet its clinical usefulness has not been evaluated. We aimed to assess prospectively whether a "routine TDM" intervention targeting imatinib Cmin of 1000 ng/mL (tolerance, 750-1500 ng/mL) could improve efficacy, tolerance, and persistence on treatment compared with "rescue TDM" use only. Patients (or Materials) and Methods: The Swiss Imatinib COncentration Monitoring Evaluation (I-COME) study was a multicenter randomized controlled trial (ISRCTN31181395). Adult patients in chronic or accelerated phase CML receiving imatinib ≤5 years were eligible. Patients were randomly (1:1) allocated to receive "routine TDM" intervention or to serve as controls with access only to "rescue TDM". All had 1-year follow-up. The primary endpoint was a combined efficacy-safety outcome (failure- and toxicity-free survival without imatinib discontinuation), analyzed in intention-to-treat. Results: Among 56 CML recruited patients, 55 had their molecular and cytogenetic response measured. 14/27 of patients receiving "routine TDM" (52% [33%-71%]) remained event-free versus 16/28 of control patients with "rescue TDM" only (57% [39%-75%]; P=0.69). In the "routine TDM" group, dosage recommendations were adopted entirely in 50% of patients (median Cmin at study end, 895 ng/mL; CV = 33%). These patients had fewer unfavorable events (28% [5%-52%]) compared with patients not receiving the advised dosage (77% [54%-99%]; P = 0.03; median Cmin at study end, 648 ng/mL; CV = 38%). Conclusion: This first prospective target concentration intervention trial could not formally demonstrate a benefit of "routine TDM" of imatinib, especially due to a small patient number and limited prescriber's adherence to dosage recommendations. Nevertheless, the patients receiving the advised dosage more often met target concentrations and the combined outcome (efficacy, tolerance, and persistence). A cycle of routine TDM could thus be favorable, at least in patients eligible for dosage adjustment. Its usefulness should, however, be further confirmed in larger trials.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Antemortem demonstration of ischemia has proved elusive in head injury because regional CBF reductions may represent hypoperfusion appropriately coupled to hypometabolism. Fifteen patients underwent positron emission tomography within 24 hours of head injury to map cerebral blood flow (CBF), cerebral oxygen metabolism (CMRO2), and oxygen extraction fraction (OEF). We estimated the volume of ischemic brain (IBV) and used the standard deviation of the OEF distribution to estimate the efficiency of coupling between CBF and CMRO2. The IBV in patients was significantly higher than controls (67 +/- 69 vs. 2 +/- 3 mL; P < 0.01). The coexistence of relative ischemia and hyperemia in some patients implies mismatching of perfusion to oxygen use. Whereas the saturation of jugular bulb blood (SjO2) correlated with the IBV (r = 0.8, P < 0.01), SjO2 values of 50% were only achieved at an IBV of 170 +/- 63 mL (mean +/- 95% CI), which equates to 13 +/- 5% of the brain. Increases in IBV correlated with a poor Glasgow Outcome Score 6 months after injury (rho = -0.6, P < 0.05). These results suggest significant ischemia within the first day after head injury. The ischemic burden represented by this "traumatic penumbra" is poorly detected by bedside clinical monitors and has significant associations with outcome.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A partial review is proposed on the existing literature for the research performed in orthopedic implant used as drug delivery system. In the first part, an evaluation is given on the clinical need to deliver a drug in the surrounding of an implant. Secondly, a review of the clinical situation is developed for implants already used as drug delivery system. Experimental works performed for local delivery are reported. In particular, a description is given on the in vitro and in vivo studies where the implant is coated with different proteins or drugs. Finally, a conclusion is proposed on the next step in the development of orthopedic implant as drug delivery system mentioning also the industrial situation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVES: To review the published literature on the diagnosis and management of adenoid cystic carcinoma (ACC) of the breast.¦MATERIALS AND METHODS: Papers were identified by searching PubMed using the terms « adenoid cystic carcinoma » and « breast ». Additional papers were identified by reviewing references of relevant articles.¦RESULTS: ACC of the breast is a rare tumour comprising less than 0.1% of breast malignancies. Its cellular origin in the breast remains unclear. The histological characteristics of ACC in the breast are similar to those of ACC of the salivary glands. However the prognosis of ACC of the breast is better than that of other localizations with prolonged survival. Breast-conserving treatment including postoperative radiotherapy seems to be equivalent to mastectomy alone with respect to survival. The value of adjuvant systemic therapies is not established. Late relapses can occur, so long-term follow-up is mandatory for these patients.¦CONCLUSIONS: ACC of the breast has a favourable prognosis. An accurate diagnosis and appropriate treatment are therefore important.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: The purpose of the present study was to submit the same materials that were tested in the round robin wear test of 2002/2003 to the Alabama wear method. METHODS: Nine restorative materials, seven composites (belleGlass, Chromasit, Estenia, Heliomolar, SureFil, Targis, Tetric Ceram) an amalgam (Amalcap) and a ceramic (IPS Empress) have been submitted to the Alabama wear method for localized and generalized wear. The test centre did not know which brand they were testing. Both volumetric and vertical loss had been determined with an optical sensor. After completion of the wear test, the raw data were sent to IVOCLAR for further analysis. The statistical analysis of the data included logarithmic transformation of the data, the calculation of relative ranks of each material within each test centre, measures of agreement between methods, the discrimination power and coefficient of variation of each method as well as measures of the consistency and global performance for each material. RESULTS: Relative ranks of the materials varied tremendously between the test centres. When all materials were taken into account and the test methods compared with each other, only ACTA agreed reasonably well with two other methods, i.e. OHSU and ZURICH. On the other hand, MUNICH did not agree with the other methods at all. The ZURICH method showed the lowest discrimination power, ACTA, IVOCLAR and ALABAMA localized the highest. Material-wise, the best global performance was achieved by the leucite reinforced ceramic material Empress, which was clearly ahead of belleGlass, SureFil and Estenia. In contrast, Heliomolar, Tetric Ceram and especially Chromasit demonstrated a poor global performance. The best consistency was achieved by SureFil, Tetric Ceram and Chromasit, whereas the consistency of Amalcap and Heliomolar was poor. When comparing the laboratory data with clinical data, a significant agreement was found for the IVOCLAR and ALABAMA generalized wear method. SIGNIFICANCE: As the different wear simulator settings measure different wear mechanisms, it seems reasonable to combine at least two different wear settings to assess the wear resistance of a new material.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In Switzerland, 9.1% of the general population accept regular consumption of BZD. In 65-74 years age group, 2% of cases display a high-risk alcohol consumption. Moderate risk consumption is present in 5% of cases. For the BZD, the cognitive difficulties settle in an insidious way; for alcohol, the daily consumption of fairly high quantities may lead to cognitive deterioration. At early stages, alcohol abusers show preserved neuropsychological performances. Gradually, the deficits will affect the remaining cognitive functions and become irreversible. This review indicates that the chronic consumption of alcohol and BZD in old age is at the origin of major clinical difficulties that need ad hoc training both for psychiatrists and general practitioners.