976 resultados para system emission limit
Resumo:
This paper considers the congestion effects on emission and consumers' allocated cost. In order to consider some environmental and operational effects of congestion, an environmental constrained active-reactive optimal power flow (AROPF) considering capability curve is presented. On outage conditions, the total cost of the system will increase. On the other hand in power systems, the operating cost and system emission have conflicted objectives, then it may be concluded that the outage in the system may lead to a total emission decrease. In this paper the famous Aumann-Shapley method is used as a pricing methodology. Two case studies such as 14-bus and US-bus IEEE test systems are conducted. Results demonstrate that, although the line outage in power systems leads to increase the total cost, the amount of emission depending on the place where the outage occurs can be more than, less than or equal to the normal conditions' emission. Also results show that although from power sellers' standpoint the well-known Aumann-Shapley method is a precise pricing method to cover the incurred cost with an acceptable error that can show the real effect of congestion on consumers' cost, from consumers' standpoint it is not a good method for cost allocation, because some consumers will face with an increase in cost and the others will face with a decrease on their cost.
Resumo:
Trabalho Final de Mestrado para obtenção do grau de Mestre em Engenharia Civil na Área de Especialização de Hidráulica
Resumo:
The objective of this thesis is to compare and contrast environmental licensing systems, for the wood panel industry, in a number of countries in order to determine which system is the best from an environmental and economic point of view. The thesis also examines the impact which government can have on industry and the type of licensing system in operation in a country. Initially, the thesis investigates the origins of the various environmental licensing systems which are in operation in Ireland, Scotland, Wales, France, USA and Canada. It then examines the Environmental Agencies which control and supervise industry in these countries. The impact which the type of government (i.e. unitary or federal) in charge in any particular country has on industry and the Regulatory Agency in that country is then described. Most of the mills in the thesis make a product called OSB (Oriented Strand Board) and the manufacturing process is briefly described in order to understand where the various emissions are generated. The main body of the thesis examines a number of environmental parameters which have emission limit values in the licenses examined, although not all of these parameters have emission limit values in all of the licenses. All of these parameters are used as indicators of the potential impact which the mill can have on the environment. They have been set at specific levels by the Environmental Agencies in the individual countries to control the impact of the mill. Following on from this, the two main types of air pollution control equipment (WESPs and RTOs) are described in regard to their function and capabilities. The mill licenses are then presented in the form of results tables which compare air results and water results separately. This is due to the fact that the most significant emission from this type of industry is to air. A matrix system is used to compare the licenses so that the comparison can be as objective as possible. The discussion examines all of the elements previously described and from this it was concluded that the IPC licensing system is the best from an environmental and economic point of view. It is a much more expensive system to operate than the other systems examined, but it is much more comprehensive and looks at the mill as a whole rather than fragmenting it. It was also seen that the type of environmental licensing system which is in place in a country can play a role in the locating of an industry as certain systems were seen to have more stringent standards attached to them. The type of standard in place in a country is in turn influenced by the type of government which is in place in that country.
Resumo:
Environmentally harmful consequences of fossil fuel utilisation andthe landfilling of wastes have increased the interest among the energy producers to consider the use of alternative fuels like wood fuels and Refuse-Derived Fuels, RDFs. The fluidised bed technology that allows the flexible use of a variety of different fuels is commonly used at small- and medium-sized power plants ofmunicipalities and industry in Finland. Since there is only one mass-burn plantcurrently in operation in the country and no intention to build new ones, the co-firing of pre-processed wastes in fluidised bed boilers has become the most generally applied waste-to-energy concept in Finland. The recently validated EU Directive on Incineration of Wastes aims to mitigate environmentally harmful pollutants of waste incineration and co-incineration of wastes with conventional fuels. Apart from gaseous flue gas pollutants and dust, the emissions of toxic tracemetals are limited. The implementation of the Directive's restrictions in the Finnish legislation is assumed to limit the co-firing of waste fuels, due to the insufficient reduction of the regulated air pollutants in the existing flue gas cleaning devices. Trace metals emission formation and reduction in the ESP, the condensing wet scrubber, the fabric filter, and the humidification reactor were studied, experimentally, in full- and pilot-scale combustors utilising the bubbling fluidised bed technology, and, theoretically, by means of reactor model calculations. The core of the model is a thermodynamic equilibrium analysis. The experiments were carried out with wood chips, sawdust, and peat, and their refuse-derived fuel, RDF, blends. In all, ten different fuels or fuel blends were tested. Relatively high concentrations of trace metals in RDFs compared to the concentrations of these metals in wood fuels increased the trace metal concentrations in the flue gas after the boiler ten- to hundred-folds, when RDF was co-fired with sawdust in a full-scale BFB boiler. In the case of peat, lesser increase in trace metal concentrations was observed, due to the higher initial trace metal concentrations of peat compared to sawdust. Despite the high removal rate of most of the trace metals in the ESP, the Directive emission limits for trace metals were exceeded in each of the RDF co-firing tests. The dominat trace metals in fluegas after the ESP were Cu, Pb and Mn. In the condensing wet scrubber, the flue gas trace metal emissions were reduced below the Directive emission limits, whenRDF pellet was used as a co-firing fuel together with sawdust and peat. High chlorine content of the RDFs enhanced the mercuric chloride formation and hence the mercury removal in the ESP and scrubber. Mercury emissions were lower than theDirective emission limit for total Hg, 0.05 mg/Nm3, in all full-scale co-firingtests already in the flue gas after the ESP. The pilot-scale experiments with aBFB combustor equipped with a fabric filter revealed that the fabric filter alone is able to reduce the trace metal concentrations, including mercury, in the flue gas during the RDF co-firing approximately to the same level as they are during the wood chip firing. Lower trace metal emissions than the Directive limits were easily reached even with a 40% thermal share of RDF co-firing with sawdust.Enrichment of trace metals in the submicron fly ash particle fraction because of RDF co-firing was not observed in the test runs where sawdust was used as the main fuel. The combustion of RDF pellets with peat caused an enrichment of As, Cd, Co, Pb, Sb, and V in the submicron particle mode. Accumulation and release oftrace metals in the bed material was examined by means of a bed material analysis, mass balance calculations and a reactor model. Lead, zinc and copper were found to have a tendency to be accumulated in the bed material but also to have a tendency to be released from the bed material into the combustion gases, if the combustion conditions were changed. The concentration of the trace metal in the combustion gases of the bubbling fluidised bed boiler was found to be a summary of trace metal fluxes from three main sources. They were (1) the trace metal flux from the burning fuel particle (2) the trace metal flux from the ash in the bed, and (3) the trace metal flux from the active alkali metal layer on the sand (and ash) particles in the bed. The amount of chlorine in the system, the combustion temperature, the fuel ash composition and the saturation state of the bed material in regard to trace metals were discovered to be key factors affecting therelease process. During the co-firing of waste fuels with variable amounts of e.g. ash and chlorine, it is extremely important to consider the possible ongoingaccumulation and/or release of the trace metals in the bed, when determining the flue gas trace metal emissions. If the state of the combustion process in regard to trace metals accumulation and/or release in the bed material is not known,it may happen that emissions from the bed material rather than the combustion of the fuel in question are measured and reported.
Resumo:
Suomen ympäristönsuojelulaki (86/200) velvoittaa toiminnanharjoittajia olemaan selvillä päästöistään ja hakemaan ympäristöluvan ympäristön pilaantumisen vaaraa aiheuttavalle toiminnalle. Sellutehtaat tuottavat tietoa merkittävimmistä ilmaan johdettavista päästöistään mittaamalla niitä jatkuvatoimisesti. Tuloksia käytetään tiedottamisessa ja päätöksenteossa. Yksi tärkeimmistä käyttökohteista on ympäristöluvan ehtojen täyttymisen seuranta. Mittaustulosten on oltava luotettavia. Luotettavuutta voidaan arvioida vertailumittauksien ja mittausepävarmuustarkastelujen avulla. Tässä työssä määritettiin mittausepävarmuudet Imatran tehtaiden kuorikattilan (LCP-kattila) NOX-mittaukselle sekä sellutehtaan meesauunien ja soodakattiloiden mittauksille. Tämän jälkeen tarkasteltiin, kuinka mittausepävarmuus huomioidaan ympäristö¬luparajaseurannassa. Lopuksi arviointiin, kuinka jatkuvatoimisten mittalaitteiden laadunvarmistusstandardia SFS-EN 141481 voidaan soveltaa Imatran tehtailla. Tarkastellut jatkuvatoimiset mittaukset todettiin varsin luotettaviksi. Etenkin NOx¬mittaukset ovat luotettavia. Kuorikattila 2:lla luotettavuutta heikentää mittauspaikan epä¬edustavuus. Rikin yhdisteiden (SO2 ja TRS) mittausten luotettavuus on alhaisempi, koska mitattavat pitoisuudet ovat pieniä. Mittausten luotettavuus on kuin vertailumittausten. Kuorikattila 2:lla Mittausepävarmuus huomioidaan NOX-pitoisuuden lupaseurannassa LCP-asetuksen mukaisesti. Sellutehtaan TRS-päästöillä mittausepävarmuus voidaan huomioida joko LCP-asetuksen mukaisesti tai tilastomatemaattisesti. Kummallakin tavalla saadaan negatiivisia luparajaan verrattavia keskiarvoja. Standardia SFS-EN 141481 voidaan soveltaa kuorikattilalla mutta sellutehtaalla se voi olla epäkäytännöllistä, eikä välittömästi paranna mittausten luotettavuutta
Resumo:
The main aim of this study was to develop the project management framework model which would serve as the new model to follow for upcoming projects at the Lappeenranta cement plant. The other goal was to execute the SNCR (selective non catalytic reduction) project successfully so that the nitrogen oxides emissions are below the stated emission limit when the new emission limit comes into effect beginning in July, 2008. Nitrogen oxides, project management aspects, SNCR and the invested system are explained in the theory part. In the practical part of the study, the SNCR project in the Lappeenranta cement plant was executed and the findings were documented. In order to reach the aim of this study, a framework of project management was made. The framework is based on the executed SNCR project, previous projects in the cement plant and on the available literature relating to the subject matter. The developed project turned out to be successful.
Resumo:
The past decade has seen the energy consumption in servers and Internet Data Centers (IDCs) skyrocket. A recent survey estimated that the worldwide spending on servers and cooling have risen to above $30 billion and is likely to exceed spending on the new server hardware . The rapid rise in energy consumption has posted a serious threat to both energy resources and the environment, which makes green computing not only worthwhile but also necessary. This dissertation intends to tackle the challenges of both reducing the energy consumption of server systems and by reducing the cost for Online Service Providers (OSPs). Two distinct subsystems account for most of IDC’s power: the server system, which accounts for 56% of the total power consumption of an IDC, and the cooling and humidifcation systems, which accounts for about 30% of the total power consumption. The server system dominates the energy consumption of an IDC, and its power draw can vary drastically with data center utilization. In this dissertation, we propose three models to achieve energy effciency in web server clusters: an energy proportional model, an optimal server allocation and frequency adjustment strategy, and a constrained Markov model. The proposed models have combined Dynamic Voltage/Frequency Scaling (DV/FS) and Vary-On, Vary-off (VOVF) mechanisms that work together for more energy savings. Meanwhile, corresponding strategies are proposed to deal with the transition overheads. We further extend server energy management to the IDC’s costs management, helping the OSPs to conserve, manage their own electricity cost, and lower the carbon emissions. We have developed an optimal energy-aware load dispatching strategy that periodically maps more requests to the locations with lower electricity prices. A carbon emission limit is placed, and the volatility of the carbon offset market is also considered. Two energy effcient strategies are applied to the server system and the cooling system respectively. With the rapid development of cloud services, we also carry out research to reduce the server energy in cloud computing environments. In this work, we propose a new live virtual machine (VM) placement scheme that can effectively map VMs to Physical Machines (PMs) with substantial energy savings in a heterogeneous server cluster. A VM/PM mapping probability matrix is constructed, in which each VM request is assigned with a probability running on PMs. The VM/PM mapping probability matrix takes into account resource limitations, VM operation overheads, server reliability as well as energy effciency. The evolution of Internet Data Centers and the increasing demands of web services raise great challenges to improve the energy effciency of IDCs. We also express several potential areas for future research in each chapter.
Resumo:
As it is defined in ATM 2000+ Strategy (Eurocontrol 2001), the mission of the Air Traffic Management (ATM) System is: “For all the phases of a flight, the ATM system should facilitate a safe, efficient, and expedite traffic flow, through the provision of adaptable ATM services that can be dimensioned in relation to the requirements of all the users and areas of the European air space. The ATM services should comply with the demand, be compatible, operate under uniform principles, respect the environment and satisfy the national security requirements.” The objective of this paper is to present a methodology designed to evaluate the status of the ATM system in terms of the relationship between the offered capacity and traffic demand, identifying weakness areas and proposing solutions. The first part of the methodology relates to the characterization and evaluation of the current system, while a second part proposes an approach to analyze the possible development limit. As part of the work, general criteria are established to define the framework in which the analysis and diagnostic methodology presented is placed. They are: the use of Air Traffic Control (ATC) sectors as analysis unit, the presence of network effects, the tactical focus, the relative character of the analysis, objectivity and a high level assessment that allows assumptions on the human and Communications, Navigation and Surveillance (CNS) elements, considered as the typical high density air traffic resources. The steps followed by the methodology start with the definition of indicators and metrics, like the nominal criticality or the nominal efficiency of a sector; scenario characterization where the necessary data is collected; network effects analysis to study the relations among the constitutive elements of the ATC system; diagnostic by means of the “System Status Diagram”; analytical study of the ATC system development limit; and finally, formulation of conclusions and proposal for improvement. This methodology was employed by Aena (Spanish Airports Manager and Air Navigation Service Provider) and INECO (Spanish Transport Engineering Company) in the analysis of the Spanish ATM System in the frame of the Spanish airspace capacity sustainability program, although it could be applied elsewhere.
Resumo:
Tese (doutorado)—Universidade de Brasília, Instituto de Química, Programa de Pós-Graduação em Química, 2015.
Resumo:
A presente tese teve por base a identificação e resolução de um problema existente no tratamento de efluentes provenientes dos processos de tratamento de superfícies por galvanoplastia, na OGMA – Indústria Aeronáutica de Portugal S.A.. Observou-se a ocorrência, esporádica, de crómio hexavalente, (Cr (VI)), em valor superior ao valor limite de emissão (VLE). Os resultados foram monitorizados e os dados recolhidos no decorrer da actividade de tratamento de efluentes, durante o período de, aproximadamente, 5 anos (2006 a 2011). A recolha de resultados decorreu no âmbito da actividade profissional da mestranda, que, para além da responsabilidade técnica dos processos de galvanoplastia na empresa, é também responsável pelo suporte técnico ao processo de tratamento de efluentes resultantes da actividade de tratamento de superficies por processos de galvanoplastia. A empresa OGMA – Indústria Aeronáutica de Portugal S.A., é uma empresa de actividade aeronáutica dedicada à Fabricação e Manutenção de aeronaves, nomeadamente a prestação de serviços de Manutenção, Revisão e Modernização de, Aeronaves, Motores e Componentes, bem como Fabricação e Montagem de Aeroestruturas. Integrada na OGMA, S.A. encontra-se a área de tratamentos electroquímicos, onde são realizados processos de tratamento de materiais metálicos por electrodeposição, deposição química e conversão química. Desta actividade resulta uma quantidade considerável de efluentes líquidos que necessitam de tratamento adequado previamente à sua descarga em cursos de água. Devido ao tipo de contaminantes que estes efluentes possuem, o tratamento dos mesmos é realizado em várias etapas, passando pela oxidação de cianetos, a redução de cromatos e a neutralização. Posteriormente segue-se uma sedimentação e a remoção de lamas. De modo a garantir um controlo dos parâmetros de descarga dos efluentes tratados, de acordo com a legislação ambiental em vigor, o efluente obtido é analisado periodicamente em laboratório acreditado. Na perspectiva de solucionar o problema em questão, procedeu-se à realização de ensaios experimentais utilizando os efluentes provenientes dos tanques de reacção da redução de cromatos e da oxidação de cianetos da linha com cádmio, com especial incidência na variação dos intervalos de pH recomendados para cada uma das fases do tratamento de efluentes, e observação do comportamento das misturas em termos de presença de Cr (VI), quando sujeitos a variações de pH. Após análise dos dados disponíveis e realização de todos os ensaios, conclui-se que, o processo de oxidação de cianeto da linha com cádmio e o processo de redução de cromatos na mesma linha estão a funcionar adequadamente. Concluiu-se que o reaparecimento de Cr (VI) ocorre devido à existência de hipoclorito de sódio, em excesso, no tanque de oxidação de cianeto que, quando passa para o tanque de neutralização e entra em contacto com o efluente proveniente do tanque de redução de cromatos, oxida parte do crómio trivalente, (Cr (III)), existente, a Cr (VI). Para impedir a ocorrência deste fenómeno separou-se todo o efluente contendo crómio que passou a ser tratado na linha de tratamento de efluentes isenta de cádmio, não entrando assim em contacto com o efluente que contém hipoclorito não reagido, evitando a oxidação do Cr (III) a Cr (VI).
Resumo:
Esta dissertação teve como objetivo clarificar a qualidade das águas residuais de uma indústria de fabricação de adesivos. Para esta clarificação optou-se por um tratamento de coagulação/floculação a ser efetuado com a adição de apenas um produto no estado sólido. Para este estudo, selecionou-se substâncias comercialmente disponíveis destacando-se para esta formulação um coagulante, sulfato de alumínio (Al2 (SO4).3H2O, dois adjuvantes, hidróxido de cálcio, Ca(OH)2 (adjuvante H) e Montmorillonite, Al2O3.4SiO2.H2O (adjuvante M) e um floculante, uma poliacrilamida aniónica (C3H5NO)n. O efluente bruto da indústria de adesivos foi caraterizado e verificou-se que dos parâmetros analisados, apenas o pH obedece aos valores limite de emissão para descarga no coletor municipal. Determinaram-se as quantidades ótimas das substâncias selecionadas, a quantidade mínima de produto formulado e foi feita a otimização da composição do produto formulado, para três níveis de pH e duas condições de agitação Numa primeira fase, a realização de ensaios preliminares sobre a quantidade de cada uma das substâncias conduziu aos valores 5 e 30 g de coagulante, 2 e 10 g de adjuvante M; 3 g de adjuvante H e 0,01 g de floculante por 500 mL de efluente. Na otimização da quantidade mínima de produto formulado obteve-se o valor de 5g de produto por 500 mL de efluente. Relativamente à formulação do produto foi definido estudar o efeito da variação das razões, %(m/m), dos adjuvantes (M e H) em função do coagulante, para diferentes valores de pH inicial (6,2; 8,1 e 10) e para duas condições de agitação (A e B), sobre os parâmetros analisados (CQO, SST, turvação, pH final e IVL). Na condição A manteve-se uma agitação de 150 rpm durante 2 minutos, reduzindo-se para 60 rpm durante 15 minutos e, por fim, para 30 rpm durante 5 minutos. Na condição B foi usada uma agitação constante de 90 rpm durante 22 minutos. O estudo do efeito das variações das razões % (m/m) dos adjuvantes M e H foi dividido em três grupos com três subgrupos: 1º grupo - 0,6 a razão mássica adjuvante M/coagulante e 0,4, 1,2 e 2 a razão mássica adjuvante H/ coagulante; 2º grupo - 0,2 a razão mássica adjuvante M/coagulante e 0,1, 0,4 e 0,6 a razão mássica adjuvante H/ coagulante; 3º grupo - 0,1 a razão mássica adjuvante M/coagulante e 0,1, 0,2 e 0,3 a razão mássica adjuvante H/ coagulante. Após este estudo obteve-se para cada condição de agitação (A e B), as razões %(m/m) e o pH inicial mais adequados, com base nos melhores resultados obtidos no efeito sobre a CQO. Para a condição de agitação A o melhor resultado obteve-se para pH inicial igual a 8,1 com a razão mássica de adjuvante M/ coagulante igual a 0,1 e a razão mássica de adjuvante H/coagulante igual a 0,1 (percentagens de remoção de 98,01%, 99,60% e 99,43% para a CQO, SST e turvação, respetivamente). Para a condição de agitação B o melhor resultado obteve-se para pH inicial igual a 8,1 com a razão mássica de adjuvante M/ coagulante igual a 0,1 e a razão mássica de adjuvante H/coagulante igual a 0,1 (percentagens de remoção de 98,67%, 99,77% e 98,40% para a CQO, SST e turvação, respetivamente). Nestas condições é necessário efetuar a correção do pH após o tratamento. Apesar das elevadas percentagens de remoção obtidas, o índice volumétrico de lamas indica fraca qualidade de sedimentação.
Resumo:
Tese de Doutoramento em Engenharia Civil.
Resumo:
This report describes the development of a SYBR Green I based real time polymerase chain reaction (PCR) protocol for detection on the ABI Prism 7000 instrument. Primers targeting the gene encoding the SSU rRNA were designed to amplify with high specificity DNA from Schistosoma mansoni, in a real time quantitative PCR system. The limit of detection of parasite DNA for the system was 10 fg of purified genomic DNA, that means less than the equivalent to one parasite cell (genome ~580 fg DNA). The efficiency was 0.99 and the correlation coefficient (R²) was 0.97. When different copy numbers of the target amplicon were used as standards, the assay could detect at least 10 copies of the specific target. The primers used were designed to amplify a 106 bp DNA fragment (Tm 83ºC). The assay was highly specific for S. mansoni, and did not recognize DNA from closely related non-schistosome trematodes. The real time PCR allowed for accurate quantification of S. mansoni DNA and no time-consuming post-PCR detection of amplification products by gel electrophoresis was required. The assay is potentially able to quantify S. mansoni DNA (and indirectly parasite burden) in a number of samples, such as snail tissue, serum and feces from patients, and cercaria infested water. Thus, these PCR protocols have potential to be used as tools for monitoring of schistosome transmission and quantitative diagnosis of human infection.
Resumo:
Venäjällä uudistetaan sähkömarkkinoita. Uudistamisella pyritään vapauttamaan sähkömarkkinat ja lisäämään kilpailua energiasektorilla. Sähkömarkkinoiden vapauttamisen tarkoitus on energiasektorin hyötysuhteen nostaminen ja investointien houkutteleminen sektorille. Venäjä on ratifioinut Kioton protokollan, mikä energiasektorin kannalta on tärkeää, koska protokollan yhteistoteutusmekanismin kautta saadaan houkuteltua investointeja sektorille. Venäjän sähkömarkkinoiden vapauttamisen pitkäaikainen tähtäin on Venäjän ja Euroopan sähkömarkkinoiden integroituminen, joka tarkoittaa myös ympäristölainsäädännönyhtenäistämistä. Tämä tutkimus on osa Fortum Oyj:n tarjoamaa teknistä katselmusta Venäjällä toimivalle sähköyhtiölle, TGC-9:lle. Tässä työssä keskitytään TGC-9:n omistamien energiatuotantolaitoksien happamoitumista aiheuttaviin ilmapäästöihin ja pölypäästöihin. Tutkimuksessa pyritään myös löytämään Kioton protokollan yhteistoteutusmekanismi hyödyntämiskohteita. NOx -päästöt tulevat olemaan suurin haaste TGC-9:lle, jos ympäristöstandardit yhdenmukaistetaan. Yhteistoteutusmekanismin hyödyntämiskohteita löydettiin neljä: koksaamokaasun hyödyntäminen, maakaasun korvaaminen kuoren poltolla ja kaksi tapausta liittyen laitoksien hyötysuhteen nostamiseen.
Resumo:
EU:n suurtenpolttolaitosten direktiivi (2001/80/EY) sekä jätteenpolttodirektiivi (2000/76/EY) aiheuttavat lähivuosina oleellisia muutoksia polttolaitosten päästöjen tarkkailuun. Nämä direktiivit on pantu täytäntöön Suomen lainsäädännössä vastaavina asetuksina. Tässä diplomityössä selvitettiin, mitä muutoksia uudistunut lainsäädäntö tuo polttolaitosten päästölaskentaan ja viranomaisraportointiin. Suurimpia muutoksia ovat päästöjen tarkkailujaksojen lyhentyminen, raja-arvojen tulkinnan muuttuminen, häiriö- sekä ylös- ja alasajojaksojen jättäminen pois pitoisuusraja-arvojen tarkkailusta sekä siirtyminen ominaispäästöjen (mg/MJ) laskennasta pitoisuusarvojen (mg/m3n) laskentaan. Päästötietojen raportoinnissa on huomioitava, että ympäristöhallinnon tavoitteena on siirtyä sähköisesti tapahtuvaan tiedonsiirtoon ja kuukausittain tapahtuvaan raportointiin kaikkien tarkkailtavien päästöjenosalta. Uudistunut ympäristölainsäädäntö koskee jo eräitä polttolaitoksia ja lopuillekin uudistuneet vaatimukset astuvat voimaan lähivuosien aikana. LCP-asetuskoskee uusia laitoksia heti, olemassa oleville laitoksille uudet mittausvelvoitteet astuvat voimaan 27.11.2004 ja asetuksen mukaiset raja-arvot 1.1.2008 alkaen. Samoin jätteenpolttoasetus koskee uusia laitoksia heti, käytössä oleville laitoksille se astuu voimaan 29.12.2005. Ensimmäisen ympäristöluvan myöntämisajankohta määrää, luetaanko laitos uusiin vai olemassa tai käytössä oleviin laitoksiin.LCP-asetuksessa uusien ja olemassa olevien laitosten päästöjen tarkkailu poikkeaa hieman toisistaan. Jätteenpoltto- ja rinnakkaispolttolaitoksilla päästöjen tarkkailun toteutustapa puolestaan riippuu poltettavan jätteen laadusta ja sen määrän suhteesta muuhun polttoaineeseen. Lisäksi tämän diplomityöprojektin aikana laadittiin yksityiskohtaiset toteutusohjeet polttolaitoksia koskevan uudistuneen ympäristölainsäädännön mukaiselle päästöjen tarkkailulle ja raportoinnille. Ohjeet laadittiin erikseen LCP- ja jätteenpolttoasetusten soveltamiseksi sekä CO2-päästöjen määrittämistä varten. Ohjeita ei ole sisällytetty tähän työhön, vaan niitä kannattaa tiedustella Kontram Oy:ltä, mikäli niihin halutaan tutustua tarkemmin.