871 resultados para screen print


Relevância:

70.00% 70.00%

Publicador:

Resumo:

Nanosized ZnO was prepared by polyol synthesis. Fluorescence spectrum of the ZnO colloid at varying pump intensities was studied. The powder was extracted and characterized by XRD and BET. The extracted powder was screen printed on glass substrates using ethyl cellulose as binder and turpinol as solvent. Coherent back scattering studies were performed on the screen printed sample which showed evidence of weak localization. The screen printed pattern showed strong UV emission.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The publishing industry is at a turning point. Facing the first major disruptive innovation in five centuries, its long-established structure and business model are at stake. Building on literature based on the pitfalls for incumbents, we interviewed key executives from the major publishers in Brazil to understand their perspective. We find that not only are they facing those pitfalls, but we also propose a new one, The Industry View Trap, concerning challenges created by convergence, the difficulty to deal with changes in the ecosystem and the fact that the very definition of the industry you're part of might have changed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Alcohol-dependent subjects tend to report lower level of response to alcohol (LR) in the years before the disorder developed, compared to control subjects. The Self-Rating of the Effects of alcohol (SRE) score is a quick and valid retrospective estimate of LR. This study examined the associations between alcohol abuse or dependence and early experience of alcohol as measured on retrospective SRE score (relating to the first five times alcohol was imbibed), and the presence of alcohol abuse or dependence, in patients attending primary care. Higher Early SRE score (i.e. greater early tolerance of alcohol) was obtained in patients with an alcohol-related diagnosis than in patients without those diagnoses. Using a cut-off of 2 on the Early SRE score, the Early SRE score could discriminate between patients with and without an alcohol diagnosis with moderate to high sensitivity (84%) and modest specificity (57%).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The MRSA-Screen test (Denka Seiken Co., Ltd., Tokyo, Japan), consisting of a slide latex agglutination kit that detects PBP 2a with a monoclonal antibody, was blindly compared to the oxacillin disk diffusion test, the oxacillin-salt agar screen, and PCR of the mecA gene for the detection of methicillin resistance in Staphylococcus aureus. A total of 120 methicillin-susceptible S. aureus (MSSA) and 80 methicillin-resistant S. aureus (MRSA) isolates, defined by the absence or presence of the mecA gene, respectively, were tested. The MRSA-Screen test, the oxacillin disk diffusion test, and the oxacillin-salt agar screening test showed sensitivities of 100, 61.3, and 82.5% and specificities of 99.2, 96.7, and 98.3%, respectively. We conclude that the MRSA-Screen is a very accurate, reliable, and fast test (15 min) for differentiation of MRSA from MSSA colonies on agar plates.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The ongoing aging of the population will lead to an increasing prevalence of chronic diseases and functional limitation. Preventative measures need to be promoted to prevent health care utilization and health costs explosion. Among these measures, those aimed at promoting early recognition of chronic conditions associated with functional decline, will have to be reinforced. This paper proposes simple, feasible, and efficient procedures to screen, in primary care practices, common geriatric conditions, as cognitive impairment, gait impairment, hearing and vision impairment or functional limitation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Print quality and the printability of paper are very important attributes when modern printing applications are considered. In prints containing images, high print quality is a basic requirement. Tone unevenness and non uniform glossiness of printed products are the most disturbing factors influencing overall print quality. These defects are caused by non ideal interactions of paper, ink and printing devices in high speed printing processes. Since print quality is a perceptive characteristic, the measurement of unevenness according to human vision is a significant problem. In this thesis, the mottling phenomenon is studied. Mottling is a printing defect characterized by a spotty, non uniform appearance in solid printed areas. Print mottle is usually the result of uneven ink lay down or non uniform ink absorption across the paper surface, especially visible in mid tone imagery or areas of uniform color, such as solids and continuous tone screen builds. By using existing knowledge on visual perception and known methods to quantify print tone variation, a new method for print unevenness evaluation is introduced. The method is compared to previous results in the field and is supported by psychometric experiments. Pilot studies are made to estimate the effect of optical paper characteristics prior to printing, on the unevenness of the printed area after printing. Instrumental methods for print unevenness evaluation have been compared and the results of the comparison indicate that the proposed method produces better results in terms of visual evaluation correspondence. The method has been successfully implemented as ail industrial application and is proved to be a reliable substitute to visual expertise.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A novel method is reported, whereby screen-printed electrodes (SPELs) are combined with dispersive liquid–liquid microextraction. In-situ ionic liquid (IL) formation was used as an extractant phase in the microextraction technique and proved to be a simple, fast and inexpensive analytical method. This approach uses miniaturized systems both in sample preparation and in the detection stage, helping to develop environmentally friendly analytical methods and portable devices to enable rapid and onsite measurement. The microextraction method is based on a simple metathesis reaction, in which a water-immiscible IL (1-hexyl-3-methylimidazolium bis[(trifluoromethyl)sulfonyl]imide, [Hmim][NTf2]) is formed from a water-miscible IL (1-hexyl-3-methylimidazolium chloride, [Hmim][Cl]) and an ion-exchange reagent (lithium bis[(trifluoromethyl)sulfonyl]imide, LiNTf2) in sample solutions. The explosive 2,4,6-trinitrotoluene (TNT) was used as a model analyte to develop the method. The electrochemical behavior of TNT in [Hmim][NTf2] has been studied in SPELs. The extraction method was first optimized by use of a two-step multivariate optimization strategy, using Plackett–Burman and central composite designs. The method was then evaluated under optimum conditions and a good level of linearity was obtained, with a correlation coefficient of 0.9990. Limits of detection and quantification were 7 μg L−1 and 9 μg L−1, respectively. The repeatability of the proposed method was evaluated at two different spiking levels (20 and 50 μg L−1), and coefficients of variation of 7 % and 5 % (n = 5) were obtained. Tap water and industrial wastewater were selected as real-world water samples to assess the applicability of the method.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A novel approach is presented, whereby gold nanostructured screen-printed carbon electrodes (SPCnAuEs) are combined with in-situ ionic liquid formation dispersive liquid–liquid microextraction (in-situ IL-DLLME) and microvolume back-extraction for the determination of mercury in water samples. In-situ IL-DLLME is based on a simple metathesis reaction between a water-miscible IL and a salt to form a water-immiscible IL into sample solution. Mercury complex with ammonium pyrrolidinedithiocarbamate is extracted from sample solution into the water-immiscible IL formed in-situ. Then, an ultrasound-assisted procedure is employed to back-extract the mercury into 10 µL of a 4 M HCl aqueous solution, which is finally analyzed using SPCnAuEs. Sample preparation methodology was optimized using a multivariate optimization strategy. Under optimized conditions, a linear range between 0.5 and 10 µg L−1 was obtained with a correlation coefficient of 0.997 for six calibration points. The limit of detection obtained was 0.2 µg L−1, which is lower than the threshold value established by the Environmental Protection Agency and European Union (i.e., 2 µg L−1 and 1 µg L−1, respectively). The repeatability of the proposed method was evaluated at two different spiking levels (3 and 10 µg L−1) and a coefficient of variation of 13% was obtained in both cases. The performance of the proposed methodology was evaluated in real-world water samples including tap water, bottled water, river water and industrial wastewater. Relative recoveries between 95% and 108% were obtained.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A novel approach is presented to determine mercury in urine samples, employing vortex-assisted ionic liquid dispersive liquid–liquid microextraction and microvolume back-extraction to prepare samples, and screen-printed electrodes modified with gold nanoparticles for voltammetric analysis. Mercury was extracted directly from non-digested urine samples in a water-immiscible ionic liquid, being back-extracted into an acidic aqueous solution. Subsequently, it was determined using gold nanoparticle-modified screen-printed electrodes. Under optimized microextraction conditions, standard addition calibration was applied to urine samples containing 5, 10 and 15 μg L−1 of mercury. Standard addition calibration curves using standards between 0 and 20 μg L−1 gave a high level of linearity with correlation coefficients ranging from 0.990 to 0.999 (N = 5). The limit of detection was empirical and statistically evaluated, obtaining values that ranged from 0.5 to 1.5 μg L−1, and from 1.1 to 1.3 μg L−1, respectively, which are significantly lower than the threshold level established by the World Health Organization for normal mercury content in urine (i.e., 10–20 μg L−1). A certified reference material (REC-8848/Level II) was analyzed to assess method accuracy finding 87% and 3 μg L−1 as the recovery (trueness) and standard deviation values, respectively. Finally, the method was used to analyze spiked urine samples, obtaining good agreement between spiked and found concentrations (recovery ranged from 97 to 100%).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Social networking apps, sites and technologies offer a wide range of opportunities for businesses and developers to exploit the vast amount of information and user-generated content produced through social networking. In addition, the notion of second screen TV usage appears more influential than ever, with viewers continuously seeking further information and deeper engagement while watching their favourite movies or TV shows. In this work, the authors present SAM, an innovative platform that combines social media, content syndication and targets second screen usage to enhance media content provisioning, renovate the interaction with end-users and enrich their experience. SAM incorporates modern technologies and novel features in the areas of content management, dynamic social media, social mining, semantic annotation and multi-device representation to facilitate an advanced business environment for broadcasters, content and metadata providers, and editors to better exploit their assets and increase their revenues.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A rich collection that looks at how the British monarchy has been seen on film and television. It is the first comprehensive look at royalty on screen. This title was made Open Access by libraries from around the world through Knowledge Unlatched.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This book examines an emerging and fast evolving phenomena: that a growing number of people engage with two screens whilst watching television. It seems a simple concept – until we discover the important implications. In doing this, this book will move way beyond the study of online and multimedia content. It will go past the impact of mobile and multi-platform technology on the media. Instead it will examine how this new concept of second screen interactivity changes the way we watch, produce, commission and monetise television programmes in the UK.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper aims at analysing the presence of gypsy characters in two neo-Victorian popular films, namely Joe Johnston’s The Wolfman (2010) and Guy Ritchie’s Sherlock Holmes: Game of Shadows (2011). The cultural construction of nineteenth-century gypsies, those “Others within Europe” (Boyarin 433) whose presence in Victorian fiction was peripheral, spectral and at times invisible (Nord 3-4), is simultaneously exploited and contested by these two neo-Victorian screen narratives to raise issues of otherness and invisibility on the screen. Setting off from the premise that screen texts, just like print texts, can also be participant in the neo-Victorian project of reimagining the underside of Victorian culture for contemporary audiences (Whelehan 273), this paper traces how the adaptation of Victorian gypsies for the screen, true to the palimpsestuous potential inherent to the process of adaptation (Hutcheon 6) and sharing the double drive between past and present which characterises the neo-Victorian genre (Arias and Pulham xiii; Shiller 539), hybridises our cultural memory of the Victorian Age on the screen while concurrently raises concerns over the persistent liminal status of gypsies in contemporary European culture. In particular, this paper illustrates how the tropes prototypically associated to gypsies (namely their nomadic lifestyle, mysticism, alienated existence or their perceived association to criminality) which can be traced back to Victorian culture are deployed on the neo-Victorian popular screen (with varyingly succesful outcomes) to comment on their (in)visibility in the European popular imagination.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Nowadays in Brazil, some social organizations, governments and mass media are discussing the need to establish an oversight committee to guarantee the quality of television programmes, as well as the need to set a system to determine what kind of pro, gram is appropriate for every television time slot. Across Brazil, a representative body of children and young people have come to the conclusion that the right to receive quality television programmes is not enough. The children of the new generations think they have the right to access new technologies and the production of their own messages, in accordance with their own creativity, interests and lifestyle projects within society.