906 resultados para liquid chromatography–mass spectrometry (LC-MS)


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Residents of certain areas of Tanzania are exposed to mycotoxins through the consumption of contaminated maize based foods. In this study, 101 maize based porridge samples were collected from villages of Nyabula, Kikelelwa and Kigwa located in different agro-ecological zones of Tanzania. The samples were collected at three time points (time point 1, during maize harvest; time point 2, 6 months after harvest; time point 3, 12 months after harvest) over a 1-year period. Ultra-performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) was used to detect and quantify 9 mycotoxins: aflatoxin B1 (AFB1), aflatoxin B2 (AFB2), aflatoxin G1 (AFG1), aflatoxin G2 (AFG2), fumonisin B1 (FB1), fumonisin B2 (FB2), deoxynivalenol (DON), ochratoxin A (OTA) and zearaleneone (ZEN) in the samples following a QuEChERS extraction method. Eighty two percent of samples were co-contaminated with more than one group of mycotoxins. Fumonisins (FB1 + FB2) had the highest percentage occurrence in all 101 samples (100%) whereas OTA had the lowest (5%). For all three villages the mean concentration of FB1 was lowest in samples taken from time point 2. Conversely, In Kigwa village there was a distinct trend that AFB1 mean concentration was highest in samples taken from time point 2. DON concentration did not differ greatly between time points but the percentage occurrence varied between villages, most notably in Kigwa where 0% of samples tested positive. ZEN occurrence and mean concentration was highest in Kikelelwa. The results suggest that mycotoxin contamination in maize can vary based on season and agro-ecological zones. The high occurrence of multiple mycotoxins found in maize porridge, a common weaning food in Tanzania, presents a potential increase in the risk of exposure and significant health implications in children.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Blooms of the brevetoxin-producing dinoflagellate Karenia brevis have been linked to high mortality of bottlenose dolphins Tursiops truncatus on Florida’s Gulf of Mexico coast. A clear understanding of trophic transfer of brevetoxin from its algal source up the food web to top predators is needed to assess exposure of affected dolphin populations. Prey fish constitute a means of accumulating and transferring brevetoxins and are potential vectors of brevetoxin to dolphins frequently exposed to K. brevis blooms. Here we report results of brevetoxin analyses of the primary fish species consumed by long-term resident bottlenose dolphins inhabiting Sarasota Bay, Florida. Fish collected during K. brevis blooms in 2003 to 2006 were analyzed by competitive enzyme-linked immunosorbent assay (ELISA) and had brevetoxin concentrations ranging from 4 to 10844 ng PbTx-3 eq g–1 tissue. Receptor binding assay (RBA) and liquid chromatography–mass spectrometry (LC-MS) analysis confirmed toxicity and the presence of parent brevetoxins and known metabolites. Fish collected in the absence of K. brevis blooms tested positive for brevetoxin by ELISA and RBA, with concentrations up to 1500 ng PbTx-3 eq g–1 tissue. These findings implicate prey fish exposed to K. brevis blooms as brevetoxin vectors for their dolphin predators and provide a critical analysis of persistent brevetoxin loads in the food web of dolphins repeatedly exposed to Florida red tides.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Mycotoxins are secondary metabolites of filamentous fungi. They pose a health risk to humans and animals due to their harmful biological properties and common occurrence in food and feed. Liquid chromatography/mass spectrometry (LC/MS) has gained popularity in the trace analysis of food contaminants. In this study, the applicability of the technique was evaluated in multi-residue methods of mycotoxins aiming at simultaneous detection of chemically diverse compounds. Methods were developed for rapid determination of toxins produced by fungal genera of Aspergillus, Fusarium, Penicillium and Claviceps from cheese, cereal based agar matrices and grains. Analytes were extracted from these matrices with organic solvents. Minimal sample clean-up was carried out before the analysis of the mycotoxins with reversed phase LC coupled to tandem MS (MS/MS). The methods were validated and applied for investigating mycotoxins in cheese and ergot alkaloid occurrence in Finnish grains. Additionally, the toxin production of two Fusarium species predominant in northern Europe was studied. Nine mycotoxins could be determined from cheese with the method developed. The limits of quantification (LOQ) allowed the quantification at concentrations varying from 0.6 to 5.0 µg/kg. The recoveries ranged between 96 and 143 %, and the within-day repeatability (as relative standard deviation, RSDr) between 2.3 and 12.1 %. Roquefortine C and mycophenolic acid could be detected at levels of 300 up to 12000 µg/kg in the mould cheese samples analysed. A total of 29 or 31 toxins could be analysed with the method developed for agar matrices and grains, with the LOQs ranging overall from 0.1 to 1250 µg/kg. The recoveries ranged generally between 44 and 139 %, and the RSDr between 2.0 and 38 %. Type-A trichothecenes and beauvericin were determined from the cereal based agar and grain cultures of F. sporotrichioides and F. langsethiae. T-2 toxin was the main metabolite, the average levels reaching 22000 µg/kg in the grain cultures after 28 days of incubation. The method developed for ten ergot alkaloids from grains allowed their quantification at levels varying from 0.01 to 10 µg/kg. The recoveries ranged from 51 to 139 %, and the RSDr from 0.6 to 13.9 %. Ergot alkaloids were measured in barley and rye at average levels of 59 and 720 µg/kg, respectively. The two most prevalent alkaloids were ergocornine and ergocristine. The LC/MS methods developed enabled rapid detection of mycotoxins in such applications where several toxins co-occurred. Generally, the performance of the methods was good, allowing reliable analysis of the mycotoxins of interest with sufficiently low quantification limits. However, the variation in validation results highlighted the challenges related to optimising this type of multi-residue methods. New data was obtained about the occurrence of mycotoxins in mould cheeses and of ergot alkaloids in Finnish grains. In addition, the study revealed the high mycotoxin-producing potential of two common fungi in Finnish crops. The information can be useful when risks related to fungal and mycotoxin contamination will be assessed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A sensitive and specific liquid chromatography-tandem mass spectrometry (LC-MS/MS) assay for the detection of several synthetic glucocorticoids in kidney, muscle and hair samples of cattle after a single intramuscular injection is described. After a dichloromethane wash of the hair samples, analytes were released from the hair matrix by enzymatic digestion. Muscle samples were also digested enzymatically using proteinase, while kidney samples were deconjugated by Helix pomatia juice. These preliminary steps were followed by a methanol extraction and a solid phase extraction (SPE) clean up step for all matrices. Chromatographic separation was achieved on a Hypersil Hypercarb column and MS/MS data were obtained in the multiple reaction monitoring mode using negative electrospray ionization. The developed protocols were evaluated by assessing residue concentrations in muscle, kidney and hair samples of thirteen calves, treated with a particular intramuscular injection of glucocorticoid. The lowest residue levels were found in muscle samples (approximately 5% of the residue levels in kidney), while high residue levels were obtained in hair samples. Hair is an interesting matrix since the sampling is non-invasive and the drugs may stay incorporated for a longer period of time. (C) 2004 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The increasing occurrence of puffer fish containing tetrodotoxin (TTX) in the Mediterranean could represent a major food safety risk for European consumers and threaten the fishing industry. The work presented herein describes the development of a new enzyme linked immunosorbent assay (mELISA) based on the immobilization of TTX through dithiol monolayers self-assembled on maleimide plates, which provides an ordered and oriented antigen immobilization and favors the antigen-antibody affinity interaction. The mELISA was found to have a limit of detection (LOD) of TTX of 0.23 mg/kg of puffer fish matrix. The mELISA and a surface plasmon resonance (SPR) immunosensor previously developed were employed to establish the cross-reactivity factors (CRFs) of 5,6,11-trideoxy-TTX, 5,11-deoxy-TTX, 11-nor-TTX-6-ol, and 5,6,11-trideoxy-4-anhydro-TTX, as well as to determine TTX equivalent contents in puffer fish samples. Results obtained by both immunochemical tools were correlated (R(2) = 0.977). The puffer fish samples were also analyzed using liquid chromatography-tandem mass spectrometry (LC-MS/MS), and the corresponding CRFs were applied to the individual TTX contents. Results provided by the immunochemical tools, when compared with those obtained by LC-MS/MS, showed a good degree of correlation (R(2) = 0.991 and 0.979 for mELISA and SPR, respectively). The mouse bioassay (MBA) slightly overestimated the CRF adjusted TTX content of samples when compared with the data obtained from the other techniques. The mELISA has been demonstrated to be fit for the purpose for screening samples in monitoring programs and in research activities.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Ce projet de maitrise implique le développement et l’optimisation de deux méthodes utilisant la chromatographie liquide à haute performance couplée à la spectrométrie de masse en tandem (HPLC-MS/MS). L'objectif du premier projet était de séparer le plus rapidement possible, simultanément, 71 médicaments traitant la dysfonction érectile (ED) et 11 ingrédients naturels parfois retrouvés avec ces médicaments dans les échantillons suspectés d’être adultérés ou contrefaits. L'objectif du deuxième projet était de développer une méthode de dépistage permettant l'analyse rapide simultanée de 24 cannabinoïdes synthétiques et naturels pour une grande variété d'échantillons tels que les mélanges à base de plantes, des bâtons d'encens, de sérums et de cannabis. Dans les deux projets, la séparation a été réalisée en moins de 10 min et cela en utilisant une colonne C18 à noyau solide 100 x 2,1 mm avec des particules de 2,6 µm de diamètre couplée à un système MS avec trappe ionique orbitale fonctionnant en électronébulisation positive. En raison du nombre élevé de composés dans les deux méthodes et de l’émergence de nouveaux analogues sur le marché qui pourraient être présents dans les échantillons futurs, une méthode de dépistage LC-MS/MS ciblée/non-ciblée a été développée. Pour les deux projets, les limites de détection étaient sous les ng/mL et la variation de la précision et de l’exactitude étaient inférieures de 10,5%. Le taux de recouvrement à partir des échantillons réels variait entre 92 à 111%. L’innovation des méthodes LC-MS/MS développées au cours des projets est que le spectre de masse obtenu en mode balayage lors de l'acquisition, fournit une masse exacte pour tous les composés détectés et permet l'identification des composés initialement non-ciblés, comme des nouveaux analogues. Cette innovation amène une dimension supplémentaire aux méthodes traditionnellement utilisées, en permettant une analyse à haute résolution sur la masse de composés non-ciblés.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Liquid chromatography-mass spectrometry (LC-MS) datasets can be compared or combined following chromatographic alignment. Here we describe a simple solution to the specific problem of aligning one LC-MS dataset and one LC-MS/MS dataset, acquired on separate instruments from an enzymatic digest of a protein mixture, using feature extraction and a genetic algorithm. First, the LC-MS dataset is searched within a few ppm of the calculated theoretical masses of peptides confidently identified by LC-MS/MS. A piecewise linear function is then fitted to these matched peptides using a genetic algorithm with a fitness function that is insensitive to incorrect matches but sufficiently flexible to adapt to the discrete shifts common when comparing LC datasets. We demonstrate the utility of this method by aligning ion trap LC-MS/MS data with accurate LC-MS data from an FTICR mass spectrometer and show how hybrid datasets can improve peptide and protein identification by combining the speed of the ion trap with the mass accuracy of the FTICR, similar to using a hybrid ion trap-FTICR instrument. We also show that the high resolving power of FTICR can improve precision and linear dynamic range in quantitative proteomics. The alignment software, msalign, is freely available as open source.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Universidad de Las Palmas de Gran Canaria, Facultad de Ciencias del Mar, Doctorado en Gestión Costera.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Chemotherapies of solid tumors commonly include 5-fluorouracil (5-FU). With standard doses of 5-FU, substantial inter-patient variability has been observed in exposure levels and treatment response. Recently, improved outcomes in colorectal cancer patients due to pharmacokinetically guided 5-FU dosing were reported. We aimed at establishing a rapid and sensitive method for monitoring 5-FU plasma levels in cancer patients in our routine clinical practice. METHODS: Performance of the Saladax My5-FU™ immunoassay was evaluated on the Roche Cobas® Integra 800 analyzer. Subsequently, 5-FU concentrations of 247 clinical plasma samples obtained with this assay were compared to the results obtained by liquid chromatography-tandem mass spectrometry (LC-MS/MS) and other commonly used clinical analyzers (Olympus AU400, Roche Cobas c6000, and Thermo Fisher CDx90). RESULTS: The My-FU assay was successfully validated on the Cobas Integra 800 analyzer in terms of linearity, precision, accuracy, recovery, interference, sample carryover, and dilution integrity. Method comparison between the Cobas Integra 800 and LC-MS/MS revealed a proportional bias of 7% towards higher values measured with the My5-FU assay. However, when the Cobas Integra 800 was compared to three other clinical analyzers in addition to LC-MS/MS including 50 samples representing the typical clinical range of 5-FU plasma concentrations, only a small proportional bias (≤1.6%) and a constant bias below the limit of detection was observed. CONCLUSIONS: The My5-FU assay demonstrated robust and highly comparable performance on different analyzers. Therefore, the assay is suitable for monitoring 5-FU plasma levels in routine clinical practice and may contribute to improved efficacy and safety of commonly used 5-FU-based chemotherapies.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The concentration of 11-nor-9-carboxy-Δ(9)-tetrahydrocannabinol (THCCOOH) in whole blood is used as a parameter for assessing the consumption behavior of cannabis consumers. The blood level of THCCOOH-glucuronide might provide additional information about the frequency of cannabis use. To verify this assumption, a column-switching liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the rapid and direct quantification of free and glucuronidated THCCOOH in human whole blood was newly developed. The method comprised protein precipitation, followed by injection of the processed sample onto a trapping column and subsequent gradient elution to an analytical column for separation and detection. The total LC run time was 4.5 min. Detection of the analytes was accomplished by electrospray ionization in positive ion mode and selected reaction monitoring using a triple-stage quadrupole mass spectrometer. The method was fully validated by evaluating the following parameters: linearity, lower limit of quantification, accuracy and imprecision, selectivity, extraction efficiency, matrix effect, carry-over, dilution integrity, analyte stability, and re-injection reproducibility. All acceptance criteria were analyzed and the predefined criteria met. Linearity ranged from 5.0 to 500 μg/L for both analytes. The method was successfully applied to whole blood samples from a large collective of cannabis consumers, demonstrating its applicability in the forensic field.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Dans les dernières années, les perturbateurs endocriniens ont été observés dans les rivières qui reçoivent des entrées importantes d’eaux usées. Parmi les perturbateurs endocriniens, les hormones stéroïdiennes naturelles et synthétiques sont des composés dont le potentiel d'imiter ou d'interférer avec les fonctions hormonales normales (développement, croissance et reproduction), est reconnu même au niveau ultra-traces (ng L-1). Bien que les hormones conjuguées soient moins actives que les hormones libres, elles peuvent être clivées et redevenir libres une fois exposées aux processus microbiens avant ou pendant le traitement des eaux usées. En raison de la nécessité d'identifier et de quantifier ces composés dans l'eau, une nouvelle méthode, entièrement automatisée, a été développée pour la détermination simultanée des deux formes de plusieurs hormones stéroïdiennes (conjuguées et libres) dans les matrices d'eau et dans l’urine des femmes. La méthode est basée sur l'extraction en phase solide couplée en ligne à la chromatographie liquide et la spectrométrie de masse en tandem (SPE-LC-MS/MS). Plusieurs paramètres ont été évalués dans le but d'optimiser l'efficacité de la méthode, tels que le type et le débit de la phase mobile, des différentes colonnes de SPE et de chromatographie, ainsi que différentes sources et modes d'ionisation des échantillons pour la MS. La méthode démontre une bonne linéarité (R2 > 0.993), ainsi qu'une précision avec un coefficient de variance inférieure à 10%. Les limites de quantification varient d’un minimum de 3 à 15 ng L-1 pour un volume d'injection entre 1 mL et 5 mL et le recouvrement des composés varie de 72 % à 117 %.