34 resultados para Quimiometria
Resumo:
This work examined the possibility of using mussel Mytella falcata as bioindicator sample to detect metal ions in several estuaries potiguares, since species substances that accumulate in their tissues due to its characteristics filter feeders have been used for environmental monitoring. The chemometrics by principal components analysis was used to reduce the size of the original data in order to establish a pattern of distribution of metal ion. Samples were collected at three different points in the estuaries Curimataú, Guaraíra-Papeba, Potengi, Galinhos-Guamaré and Piranhas-Assu having been marked with the location using GPS (Global Positioning System). The determination of humidity content and digestion of the samples were performed using methods described in the Compendium of analytical standards of the Institute Adofo Lutz (2005) and the determination of metal ions of the elements Al, Ba, Cd, Cr, Cu, Mn, Ni, Pb, Sn and Zn were performed by optical emission spectrometry with inductively coupled plasma as described by USEPA method 6010C. The results show that it is possible to use this molluscum Mytella falcata in the estuaries of Rio Grande do Norte for the determination of metal ions. The data were subjected to principal components analysis (PCA) which enabled us to verify the distribution pattern of the metal ions studied in several estuaries potiguares and group them according to the metal ions in common with and relate them to the activities in each region
Resumo:
Enzimas Peroxidases são heme-proteínas encontradas nos diferentes organismos vivos, especialmente vegetais, apresentam importante papel fisiológico/bioquímico como proteção contra microorganismos invasores. A soja, um dos mais importantes produtos para o agronegócio brasileiro apresenta na casca de suas sementes (subproduto) alta atividade de peroxidase, denominada soybean peroxidase,com potencial de utilização em métodos analíticos clínicos. A proposta do trabalho foi aplicar o planejamento fatorial para otimização das condições extração da enzima, definição das condições ótimas de atividade (pH e temperatura), utilizando metodologia de superfície de resposta. Os dados obtidos com clara definição foram: i) extração em pó cetonico, ii) meio reacional: pH 3,3, volume da amostra contendo a enzima 330 µL - 340 µL, peróxido de hidrogênio 4,2 mmol.L-1 150 µL, tempo de reação 20 segundos, temperatura 50º C, substrato guaiacol 30mmol.L-1 300 µL, e 0,1 mol.L-1 de NaCl. O uso da dessa metodologia para definição das condições de extração e estudos cinético-enzimáticos da peroxidase de soja foram eficientes e mais precisos, comparado a metodologia de variações/repetições (tentativa e erro).
Resumo:
Pós-graduação em Química - IQ
Resumo:
O presente texto visa documentar os resumos de oito palestras ministradas no 1º Workshop de Aplicações de Espectroscopia NIR e Quimiometria em Análise de Solos. Os principais temas abordados neste texto são: (1) preparo de amostras de solo para Espectroscopia NIR; (2) técnicas quimiométricas aplicadas à espectroscopia NIR; (3) desenvolvimento e validação de métodos multivariados em espectroscopia NIR; (4) figuras de mérito em análise multivariada; e (5) aplicação da espectroscopia NIR em matrizes de interesse agronômico.
Resumo:
Esse trabalho compreende dois diferentes estudos de caso: o primeiro foi a respeito de um medicamento para o qual foi desenvolvida uma metodologia para determinar norfloxacino (NOR) por espectrofluorimetria molecular e validação por HPLC. Primeiramente foi desenvolvida uma metodologia por espectrofluorimetria onde foram feitos alguns testes preliminares a fim de estabelecer qual valor de pH iria fornecer a maior intensidade de emissão. Após fixar o pH foi feita a determinação de NOR em padrões aquosos e soluções do medicamento usando calibração univariada. A faixa de concentração trabalhada foi de 0500 μg.L-1. O limite de detecção para o medicamento foi de 6,9 μg.L-1 enquanto que o de quantificação foi de 24,6 μg.L-1. Além dessas, outras figuras de mérito também foram estimadas para desenvolvimento da metodologia e obtiveram resultados muito satisfatórios, como por exemplo, os testes de recuperação no qual a recuperação do analito foi de 99.5 a 103.8%. Para identificação e quantificação do NOR da urina foi necessário diluir a amostra de urina (estudada em dois diferentes níveis de diluição: 500 e 1000 x) e também uso do método da adição de padrão (na mesma faixa de concentração usada para medicamento). Após a aquisição do espectro, todos foram usados para construção do tensor que seria usado no PARAFAC. Foi possível estimar as figuras de mérito como limite de detecção de 11.4 μg.L-1 and 8.4 μg.L-1 (diluição de 500 e 1000 x respectivamente) e limite de quantificação de 34 μg.L-1 e 25.6 μg.L-1 (diluição de 500 x e 1000 x respectivamente). O segundo estudo de caso foi na área alimentícia no qual se usou espectroscopia NIR e FT MIR acopladas a quimiometria para discriminar óleo de soja transgênica e não transgênica. Os espectros dos óleos não mostraram diferença significativa em termos visuais, sendo necessário usar ferramentas quimiométricas capazes de fazer essa distinção. Tanto para espectroscopia NIR quanto FT MIR foi feito o PCA a fim de identificar amostras discrepantes e que influenciariam o modelo de forma negativa. Após efetuar o PCA, foram usadas três diferentes técnicas para discriminar os óleos: SIMCA, SVM-DA e PLS-DA, sendo que para cada técnica foram usados também diferentes pré processamento. No NIR, apenas para um pré processamento se obteve resultados satisfatórios nas três técnicas, enquanto que para FT-MIR ao se usar PLS-DA se obteve 100% de acerto na classificação para todos os pré processamentos
Resumo:
O presente trabalho teve como objectivo proceder à avaliação da qualidade nutricional de 20 variedades regionais de Phaseolus vulgaris L. e à análise comparativa dos parâmetros bioquímicos (nutricionais e anti-nutricionais) obtidos recorrendo às técnicas analíticas convencionais por química molhada e de NIRS (Near Infra-Red Spectroscopy). Uma tipificação das variedades regionais de feijão foi realizada recorrendo a sete parâmetros ou caracteres (traits) nutricionais compreendidos em humidade, proteína bruta, lípidos totais, açúcares solúveis, amido, cinzas e minerais. A faseolamina foi incluída na tipificação do feijão como parâmetro anti-nutricional enquanto inibidor de enzimas digestivas. A variedade que apresentou uma melhor qualidade nutricional foi o feijão vermelho (ISOP 00724), enquanto que o feijão Filipe (ISOP 00478) apresentou uma maior actividade inibitória da PPA (amilase do pâncreas suíno), contribuindo de igual forma como uma característica de qualidade deste feijão. A aplicação de técnicas de quimiometria na quantificação dos vários parâmetros de qualidade nutricional, através da técnica de NIRS, permitiu o desenvolvimento dos modelos PLS globais após a colecção dos valores de referência e obtenção dos respectivos espectros de cada ISOP em análise. A análise comparativa dos parâmetros nutricionais, recorrendo às técnicas analíticas convencionais por química molhada e de NIRS, permitiu relacionar os parâmetros cinzas e proteína bruta como os principais critérios nutricionais para distinção das variedades regionais quanto à sua qualidade, ao diferirem significativamente relativamente aos parâmetros restantes. A partir destas duas técnicas, conclui-se que a espectroscopia NIR associada a técnicas de análise multivariada consegue quantificar os parâmetros em estudo, permitindo distinguir amostras das variedades regionais, quanto às suas características nutricionais, exigindo uma preparação reduzida da amostra, com consequente custo de análise muito reduzido. Este trabalho representou o início de uma base de fenotipagem a partir de caracteres nutricionais, estabelecendo-se um perfil das variedades regionais de feijão e avaliação da importância dos caracteres na sua distinção e tipagem.
Resumo:
This thesis aimed to assess the increase in solubility of simvastatin (SINV) with solid dispersions using techniques such as kneading (MA), co-solvent evaporation (ES), melting carrier (FC) and spray dryer (SD). Soluplus (SOL), PEG 6000 (PEG), PVP K-30 (PVP) e sodium lauryl sulphate (LSS) were used as carriers. The solid dispersions containing PEG [PEG-2(SD)], Soluplus [SOL-2(MA)] and sodium lauryl sulphate [LSS-2(ES)] were presented with a greater increase in solubility (5.02, 5.60 and 5.43 times respectively); analyses by ANOVA between the three groups did not present significant difference (p<0.05). In the phase solubility study, the calculation of the Gibbs free energy (ΔG) revealed that the spontaneity of solubilisation of SINV occurred in the order SOL>PEG >PVP 75%>LSS, always 80%. The phase diagrams of PEG and LSS presented solubilization stoichiometry of type 1:1 (type AL). The diagrams with PVP and SOL tend to 1:2 stoichiometry (type AL + AP). The stability coefficients (Ks) of the phase diagrams revealed that the most stable reactions occurred with LSS and PVP. The solid dispersions were characterized by Fourier transform infrared (FTIR), differential scanning calorimetry (DSC), scanning electron microscopy (SEM), particle size distribution (PSD), near-infrared spectroscopy imaging (NIR-CI) and X-ray diffraction of the powder using the Topas software (PDRX-TOPAS). The solid dispersion PEG-2(SD) presented the greatest homogeneity and the lowest degree of crystallinity (18.2%). The accelerated stability study revealed that the solid dispersions are less stable than SINV, with PEG-2(SD) being the least stable, confirmed by FTIR and DSC. The analyses by PDRX-TOPAS revealed the amorphous character of the dispersions and the mechanism of increasing solubility
Resumo:
PAHs (Polycyclic Aromatic Hydrocarbons) are a group of organic substances which receive considerable attention because of the carcinogenic and mutagenic properties of some of them. It is therefore important to determine the PAHs in different environmental matrices. Several studies have shown the use of gas chromatography coupled to mass spectrometry as a technique for quantification of PAHs by presenting excellent detection limits. This study aimed to develop an analytical methodology for the determination of 16 PAHs listed by the USEPA, test two methods for extraction of PAHs in water from a 23 factorial design, quantify them through the analytical technique coupled to gas chromatography mass spectrometry (GC/MS) using the method developed, and finally apply the results in chemometrics. The sample was synthesized and subjected to tests of the 23 factorial design, which has the factors: the type of extraction technique (ultrasound and digester), the ratio solvent / sample (1:1 and 1:3) and the type of solvent (dichloromethane / hexane and acetone / dichloromethane). The responses of eight combinations of the factorial design were obtained from the quantification by external calibration in GC/MS. The quantification method was developed from an optimized adaptation of the USEPA Method 8270. We used the full scan mode as a way of acquiring the mass spectra of 16 PAHs. The time in which the samples were subjected to ultrasound was fixed at 10 min and held an investigation to establish the conditions of power and time in the digester. We had the best response in the investigation of the digester power of 100 watts and the time of six minutes. The factorial design of liquid-liquid extraction showed that the most representative factors were: the use of the digester as extraction technique, the ratio solvent / sample 1:1 and the use of a 1:1 mixture of dichloromethane / hexane as a solvent more suitable. These results showed that the 1:1 mixture of dichloromethane / hexane is an excellent mixture to recover the extraction of PAHs an aqueous sample using the microwave digester. The optimization of the method of separation, identification and quantification of PAHs in the GC/MS was valid for 16 PAHs present in each chromatogram of the samples
Resumo:
The proposal of this work is to evaluate the influence of the organic matter on the results of the analyses of the metals (Zn, Pb, Al, Cu, Cr, Fe, Cd e Ni) for Atomic Absorption Spectrometry (AAS), so much in the extraction stage as in the reading using for that the chemometrics. They were used for this study sample of bottom sediment collected in river Jundiaí in the vicinity of the city of Macaíba-RN, commercial humus and water of the station of treatment of sewer of UFRN. Through the analyses accomplished by EAA it was verified that the interference of the organic matter happens in the extraction stage and not in the reading. With relationship to the technique of X Ray Fluorescence Spectrometry (XRFS), the present work has as intended to evaluate the viability of this technique for quantitative analysis of trace metals (Cr, Ni, Cu, Zn, Rb, Sr and Pb) in having leached obtained starting from the extraction with acqua regia for an aqueous solution. The used samples constitute the fine fraction (<0.063 mm) of sediments of swamp of the river Jundiaí. The preparation of tablets pressed starting from the dry residue of those leached it allowed your analysis in the solid form. This preliminary study shows that, in the case of the digestion chemistry partially of the fine fractions of bottom sediments used for environmental studies, the technique of applied EFRX to the analysis of dry residues starting from having leached with acqua regia, compared her it analyzes of the leached with ICP-OES, it presents relative mistakes for Cu, Pb, Sr and Zn below 10%
Resumo:
This work is combined with the potential of the technique of near infrared spectroscopy - NIR and chemometrics order to determine the content of diclofenac tablets, without destruction of the sample, to which was used as the reference method, ultraviolet spectroscopy, which is one of the official methods. In the construction of multivariate calibration models has been studied several types of pre-processing of NIR spectral data, such as scatter correction, first derivative. The regression method used in the construction of calibration models is the PLS (partial least squares) using NIR spectroscopic data of a set of 90 tablets were divided into two sets (calibration and prediction). 54 were used in the calibration samples and the prediction was used 36, since the calibration method used was crossvalidation method (full cross-validation) that eliminates the need for a validation set. The evaluation of the models was done by observing the values of correlation coefficient R 2 and RMSEC mean square error (calibration error) and RMSEP (forecast error). As the forecast values estimated for the remaining 36 samples, which the results were consistent with the values obtained by UV spectroscopy
Resumo:
This work aims to detect polycyclic aromatic hydrocarbons (PAHs) through optimized analytical techniques, such as gas chromatography with flame-ionisation detector (CGFID), gas chromatography coupled to mass spectrometry (CGMS), Fluorescence Spectroscopy of Molecular and Purpot of oils and greases (POG). Apply to chemometrics, Factorial Planning 23, in the preparation of samples by liquid-liquid extraction. The sample preparation was used for liquid-liquid extraction and factors in this sample was used for the application of factorial planning 23, such as the use of ultrasound, solvents (dichloromethane, hexane and chloroform) and ratio of solvent / synthetic sample. These factors were assigned two types of levels: positive and negative. It was used to form the cube to better analyze the answers. The responses of the eight combinations were obtained in reading the spectrofluorimetric. The optimization of equipment were used, and they served in the HPA's identification of the samples collected in Rio Potengi. The optimization of the equipment was observed every 16's and PAH in the samples was found that the HPA's came from contamination of the Rio Potengi. The contamination comes through organic household waste, hospital waste, and among other contamination that comes from industries that are installed around the River The factorial design of high validity, it was observed a more effective sample preparation. The factorial design of liquid-liquid extraction showed a way to spend less solvent in less time using an ideal solvent, but also a way to extract more analyte from the matrix itself is water. In planning a smaller form factor extraction was the use of ultrasound, the ratio 1:3 corresponding to a solvent and sample 3 and the best solvent was dichloromethane who presented a viable extraction, not discarding the possibility of using also the hexane. The chloroform and may be toxic not had a good extraction
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)