723 resultados para Mitral Annulus
Resumo:
Caseous calcification of the mitral annulus is a rare form of mitral annular calcification, whose etiology is not completely understood and which can lead to an erroneous diagnosis of intracardiac tumor. The authors describe the cases of six patients, five of them female, mean age 74.8 +/- 6.4 years (65-81). Four patients presented with heart failure, two with atrial fibrillation and five with hypertension. Round, echogenic images, 18-26 mm in their largest diameter with a central echolucent area, were identified by transthoracic echocardiography on the lateral and posterior segments of the mitral annulus. Severe mitral regurgitation was also found in four patients. Only three patients with severe mitral regurgitation and heart failure were operated on, and one patient refused surgical treatment. A caseous mass, similar to toothpaste, was obtained from the mitral annulus zone during surgery.
Resumo:
OBJECTIVE: To describe a surgical procedure utilizing a malleable bovine pericardium ring in mitral valve repair and clinical and echodopplercadiographic results. METHODS: Thirty-two (25 female and 7 male) patients, aged between 9 and 66 (M=36.4±17.2) years, were studied over a 16-month period, with 100% follow-up. In 23 (72%) of the patients, the mitral approach was the only one applied; 9 patients underwent associated operations. The technique applied consisted of measuring the perimeter of the anterior leaflet and implanting, according to this measurement, a flexible bovine pericardium prosthesis for reinforcement and conformation of the posterior mitral annulus, reducing it to the perimeter of the anterior leaflet with adjustment of the valve apparatus. RESULTS: The patient survival ratio was 93.8%, with 2 (6.2%) fatal outcomes, one from unknown causes, the other due to left ventricular failure. Only one reoperation was performed. On echodopplercardiography, 88% of the patients had functional recovery of the mitral valve (50% without and 38% with mild insufficiency and no hemodynamic repercussions). Of four (12%) of the remaining patients, 6% had moderate and 6% had seigre insufficiency. Twenty-eight percent of class II patients and 72% of class III patients passed into classes I (65%), II (32%), and III (3%), according to NYHA classification criteria. CONCLUSION: Being flexible, the bovine pericardium ring fit perfectly into the valve annulus, taking into account its geometry and contractility. Valve repair was shown to be reproducible, demonstrating significant advantages during patient evolution, which did not require anticoagulation measures.
Resumo:
OBJECTIVE: This study evaluated the effects of a new method of mitral valve replacement on left ventricular (LV) remodeling and heart failure functional class. METHODS: Eight patients (6 men) with severe mitral regurgitation from end-stage dilated cardiomyopathy underwent surgery. Five patients were in functional class (FC) IV, 2 were in FC III and 1 was in FC III/IV. Age ranged from 33 to 63 years. Both the anterior and posterior leaflets of the mitral valve were divided into hemileaflets. The resultant 4 pedicles were displaced under traction toward the left atrium and anchored between the mitral annulus and an implanted valvular prosthesis. The beating heart facilitated ideal chordae tendineae positioning. RESULTS: All patients survived and were discharged from the hospital. After a mean follow-up period of 6.5 months (1-12 m), 5 patients were in FC I; 2 in FC I/II; and 1 in FC II. The preoperative ejection fraction ranged from 19% to 30% (mean: 25.7±3.4 %), and the postoperative ejection fraction ranged from 21% to 40% (mean: 31.1± 5.8%). Doppler echocardiography showed evidence of LV remodeling in 4 patients, including lateral wall changes and a tendency of the LV cavity to return to its elliptical shape. CONCLUSION: This technique of mitral valve replacement, involving new positioning of the chordae tendineae, allowed LV remodeling and improvement in FC during this brief follow-up period.
Resumo:
The case of a 16-year-old patient with atrioventricular tachycardia caused by a single left anterolateral accessory pathway is reported. When the patient underwent radiofrequency ablation, a lesion on the mitral annulus lateral wall produced changes in the retrograde atrial activation pattern determined by that pathway; changes ranged from a delay in depolarization of the annulus posterior portions to full left atrium counterclockwise activation. Such phenomena were probably caused by a block in the isthmus between the annulus and the lower left pulmonary vein ostium. This case illustrates the importance of the mitral-pulmonary isthmus in the process of left atrium activation, an alert to changes induced by its unintentional block during accessory pathway ablation.
Resumo:
OBJECTIVES: Residual mitral regurgitation after valve repair worsens patients' clinical outcome. Postimplant adjustable mitral rings potentially address this issue, allowing the reshaping of the annulus on the beating heart under echocardiography control. We developed an original mitral ring allowing valve geometry remodelling after the implantation and designed an animal study to assess device effectiveness in correcting residual mitral regurgitation. METHODS: The device consists of two concentric rings: one internal and flexible, sutured to the mitral annulus and a second external and rigid. A third conic element slides between the two rings, modifying the shape of the flexible ring. This sliding element is remotely activated with a rotating tool. Animal model: in adult swine, under cardio pulmonary bypass and cardiac arrest, we shortened the primary chordae of P2 segment to reproduce Type III regurgitation and implanted the active ring. We used intracardiac ultrasound to assess mitral regurgitation and the efficacy of the active ring to correct it. RESULTS: Severe mitral regurgitation (3+ and 4+) was induced in eight animals, 54 ± 6 kg in weight. Vena contracta width decreased from 0.8 ± 0.2 to 0.1 cm; proximal isovelocity surface area radius decreased from 0.8 ± 0.2 to 0.1 cm and effective regurgitant orifice area decreased from 0.50 ± 0.1 to 0.1 ± 0.1 cm(2). Six animals had a reversal of systolic pulmonary flow that normalized following the activation of the device. All corrections were reversible. CONCLUSIONS: Postimplant adjustable mitral ring corrects severe mitral regurgitation through the reversible modification of the annulus geometry on the beating heart. It addresses the frequent and morbid issue of recurrent mitral valve regurgitation.
Resumo:
OBJECTIVES: The study aimed to evaluate the feasibility of off-pump transapical mitral valve-in-ring implantation and to test the performance of a custom-made self-expandable stent valve, in comparison with the standard SAPIEN valve. METHODS: Acute experiments were performed in five pigs. Animals (mean weight 58.4 ± 7.3 kg) underwent mitral valve annuloplasties under cardiopulmonary bypass using 26-mm rings (SJM?). Then, a 30-mm custom-made self-expandable stent valve or a 23-mm balloon-expandable transcatheter heart valve (Edwards SAPIEN XT?) was deployed within the annuloplasty rings through a transatrial access and under direct vision. Subsequently, the stent valves were inserted transapically under fluoroscopic guidance and off pump. RESULTS: The procedural success of transatrial and transapical mitral valve-in-ring procedures was 100% (10 of 10). Mean transatrial and transapical procedure time was 2.0 ± 1.1 and 22.0 ± 5.7 min, respectively. Haemodynamic status during transapical implantation remained stable, and differences in data collected before and after the stent-valve deployment were not statistically significant. Mean mitral annulus diameter and mean mitral orifice area in the group of self-expandable stent valves were 2.60 ± 0.02 cm and 4.16 ± 0.48 cm(2), respectively, whereas in the SAPIEN group they were 1.95 ± 0.18 cm and 2.26 ± 0.20 cm(2), respectively. Trace or mild regurgitation was detected only in the self-expandable stent-valve group. Mean gradients were 4.1 ± 4.5 mmHg across the self-expandable stent valves and 1.0 ± 0 mmHg across the SAPIEN valves. Postmortem examination confirmed adequate positioning of the self-expandable valves and the SAPIEN valves within the annuloplasty ring. CONCLUSIONS: Off-pump transapical mitral valve-in-ring implantation is safe and feasible. Transapical access may represent the ideal option for valve-in-ring procedures in cases of recurrent mitral regurgitation after mitral valve repair, in high-risk patients. Owing to the supra-annular profile of the valve components, our custom-made nitinol stent valve provides nearer to normal functional area than the SAPIEN valve.
Resumo:
INTRODUCTION: Mitral isthmus (MI) ablation is an effective option in patients undergoing ablation for persistent atrial fibrillation (AF). Achieving bidirectional conduction block across the MI is challenging, and predictors of MI ablation success remain incompletely understood. We sought to determine the impact of anatomical location of the ablation line on the efficacy of MI ablation. METHODS AND RESULTS: A total of 40 consecutive patients (87% male; 54 ± 10 years) undergoing stepwise AF ablation were included. MI ablation was performed in sinus rhythm. MI ablation was performed from the left inferior PV to either the posterior (group 1) or the anterolateral (group 2) mitral annulus depending on randomization. The length of the MI line (measured with the 3D mapping system) and the amplitude of the EGMs at 3 positions on the MI were measured in each patient. MI block was achieved in 14/19 (74%) patients in group 1 and 15/21 (71%) patients in group 2 (P = NS). Total MI radiofrequency time (18 ± 7 min vs. 17 ± 8 min; P = NS) was similar between groups. Patients with incomplete MI block had a longer MI length (34 ± 6 mm vs. 24 ± 5 mm; P < 0.001), a higher bipolar voltage along the MI (1.75 ± 0.74 mV vs. 1.05 ± 0.69 mV; P < 0.01), and a longer history of continuous AF (19 ± 17 months vs. 10 ± 10 months; P < 0.05). In multivariate analysis, decreased length of the MI was an independent predictor of successful MI block (OR 1.5; 95% CI 1.1-2.1; P < 0.05). CONCLUSIONS: Increased length but not anatomical location of the MI predicts failure to achieve bidirectional MI block during ablation of persistent AF.
Resumo:
Case: A 11 yo girl with Marfan syndrome was referred to cardiac MR (CMR) to measure the size of her thoracic aorta. She had a typical phenotype with arachnodactyly, abnormally long arms, and was tall and slim (156 cm, 28 kg, body mass index 11,5 kg/m2). She complained of no symptoms. Cardiac auscultation revealed a prominent mid-systolic click and an end-systolic murmur at the apex. A recent echocardiogram showed a moderately dilated left ventricle with normal function and a mitral valve prolapse with moderate mitral valve regurgitation. CMR showed a dilatation of the aortic root (38 mm, Z-score 8.9) and a severe prolapse of the mitral valve with regurgitation. The ventricular cavity was moderately dilated (116 ml/m2) and its contraction was hyperdynamic (stroke volume (SV): 97 ml; LVEF 72%, with the LV volumes measured by modified Simpson method from the apex to the mitral annulus). In this patient however, the mitral prolapse was characterized by a severe backward movement of the valve toward the left atrium (LA) in systole and the dyskinetic movement of the atrioventricular plane caused a ventricularisation of a part of the LA in systole (Figure). This resulted in a significant reduction of LVEF: more than ¼ of the apparent SV was displaced backwards into the ventricularized LA volume, reducing the effective LVEF to 51% (effective SV 69ml). Moreover, by flow measurement, the SV across the ascending aorta was 30 ml (cardiac index 2.0 l/min/m2) allowing the calculation of a regurgitant fraction across the mitral valve of 56%, which was diagnostic for a severe mitral valve insufficiency. Conclusion: This case illustrates the phenomenon of a ventricularisation of the LA where the severe prolapse gives the illusion of a higher attachement of the mitral leaflets within the atrial wall. Besides the severe mitral regurgitation, this paradoxical backwards movement of the valve causes an intraventricular unloading during systole reducing the apparent LVEF of 72% to an effective LVEF of only 51%. In addition, forward flow fraction is only 22% after accounting for the regurgitant volume, as well. This combined involvement of the mitral valve could explain the discrepancy between a low output state and an apparently hyperdynamic LV contraction. Due to its ability to precisely measure flows and volumes, CMR is particularly suited to detect this phenomenon and to quantify its impact on the LV pump function.
Resumo:
OBJETIVOS: Describir y comparar los cambios dinámicos de la geometría del anillo mitral durante todo el ciclo cardiaco en pacientes con insuficiencia mitral isquémica y pacientes con válvula mitral normal. MATERIALES Y MÉTODOS: Los estudios ecocardiográficos analizados fueron 37, 23 con insuficiencia mitral isquémica y 14 con válvula mitral normal. La reconstrucción del anillo se realizó en la estación de trabajo Xcelera (Philips Medial Systems) mediante la herramienta de análisis mitral (MVQ), en 5 momentos del ciclo cardiaco: Comienzo de Sístole, Mitad de Sístole, Final de Sístole, Mitad de Diástole y Final de Diástole. RESULTADOS: El anillo del grupo control, fue más dinámico, con sus menores dimensiones al final de la diástole, presentando incremento progresivo durante la sístole. Los cambios en el perímetro y el área, fueron significativos entre el comienzo y mitad de la sístole (p:0.087 y p: 0.055). En el grupo con insuficiencia mitral isquémica, el anillo fue más estático. Todas las dimensiones en este grupo, fueron mayores en los cinco momentos del ciclo cardiaco. (p < 0.1). El anillo también fue más plano, con un índice morfológico anular menor al del grupo control (p:0.087). DISCUSIÓN Y CONCLUSIONES: En pacientes sin insuficiencia mitral, el anillo es una estructura dinámica. Durante la sístole, las menores dimensiones se produjeron al comienzo de este periodo y la conformación en silla de montar se mantuvo, protegiendo contra la insuficiencia mitral. El anillo del grupo con insuficiencia mitral fue más estático y plano, perdiendo los mecanismos protectores.
Resumo:
OBJECTIVES To validate a self-expanding transcatheter valve for off-pump transatrial mitral valve-in-ring (VIR) implantation via a left thoracotomy. METHODS Mitral valve annuloplasty was performed via sternotomy during cardiopulmonary bypass on 9 pigs. After successful weaning from extracorporal circulation, the custom-made, self-expanding transcatheter VIR device was deployed under fluoroscopic guidance within the annuloplasty ring via a left thoracotomy. Hemodynamic data before and after the implantation were recorded. Mitral annulus diameter and valve area were measured by echocardiography. Transvalvular and left-ventricular outflow-tract pressure gradient were measured invasively. RESULTS Eight successful implantations were performed. Implantation failed in 1 pig because of difficulty with technical delivery of the sheath. Mean transatrial procedure time was 12.6 ± 1.7 min. Hemodynamic status during transatrial implantation was stable, and differences were not statistically significant. Mean mitral annulus diameter and mean mitral orifice area were 2.32 ± 0.2 and 3.84 ± 0.55 cm2, respectively. Mild regurgitation was detected in 7 animals and moderate regurgitation in 1. Mean gradients were 6.1 ± 5.0 mm Hg across the device. Postmortem examination confirmed adequate positioning of devices within the annuloplasty ring. CONCLUSIONS This custom-made transcatheter device allows for safe and reproducible off-pump transatrial mitral VIR implantations. Transatrial access is a promising route to facilitate VIR implantations. Our custom-made stent-valve may be suitable for VIR procedures.
Resumo:
INTRODUCTION Mitral isthmus (MI) ablation is an effective option in patients undergoing ablation for persistent atrial fibrillation (AF). Achieving bidirectional conduction block across the MI is challenging, and predictors of MI ablation success remain incompletely understood. We sought to determine the impact of anatomical location of the ablation line on the efficacy of MI ablation. METHODS AND RESULTS A total of 40 consecutive patients (87% male; 54 ± 10 years) undergoing stepwise AF ablation were included. MI ablation was performed in sinus rhythm. MI ablation was performed from the left inferior PV to either the posterior (group 1) or the anterolateral (group 2) mitral annulus depending on randomization. The length of the MI line (measured with the 3D mapping system) and the amplitude of the EGMs at 3 positions on the MI were measured in each patient. MI block was achieved in 14/19 (74%) patients in group 1 and 15/21 (71%) patients in group 2 (P = NS). Total MI radiofrequency time (18 ± 7 min vs. 17 ± 8 min; P = NS) was similar between groups. Patients with incomplete MI block had a longer MI length (34 ± 6 mm vs. 24 ± 5 mm; P < 0.001), a higher bipolar voltage along the MI (1.75 ± 0.74 mV vs. 1.05 ± 0.69 mV; P < 0.01), and a longer history of continuous AF (19 ± 17 months vs. 10 ± 10 months; P < 0.05). In multivariate analysis, decreased length of the MI was an independent predictor of successful MI block (OR 1.5; 95% CI 1.1-2.1; P < 0.05). CONCLUSIONS Increased length but not anatomical location of the MI predicts failure to achieve bidirectional MI block during ablation of persistent AF.
Resumo:
Radiofirequency ablation of the pulmonary veins has been used to treat patients with paroxysmal atrial fibrillation (AF), and atrial damage after ablation is an issue of concern. To evaluate left atrial function shortly and midterm after ablation, 33 consecutive patients with paroxysmal AF were studied at baseline, 24 hours, and >= 6 months after ablation. Patients in sinus rhythm with normal ventricular function were included in the study. Echocardiographic measurements of left atrial volumes (Simpson`s rule) and transmitral and tissue Doppler myocardial (A`) velocities at the septal and lateral mitral annulus were undertaken at each time. Left atrial emptying fraction (EF; maximal - minimal left atrial volume/maximal left atrial volume) was used to express left atrial function. After 8 +/- 2 months, 30 of 33 patients returned (23 men, age 53 +/- 13 years), and all except 2 were in sinus rhythm. Shortly after ablation, left atrial minimal volumes increased (from 30 +/- 15 to 35 +/- 15 ml; p = 0.02), with maximal volumes unchanged, resulting in decreased left atrial EF (from 47 +/- 8 to 40 +/- 7 ml; p <0.05). Tissue Doppler septal A` velocities also decreased (from 8.2 +/- 1.8 to 6.9 +/- 2.0 cm/s; p <0.05). However, after midterm follow-up, both left atrial EF and septal A` velocities had slightly increased compared with shortly after ablation, although left atrial volumes remained similar to baseline. Septal A` velocity changes paralleled left atrial EF both shortly (r = 0.46, p = 0.02) and at midterm after ablation (r = 0.47, p = 0.01). In conclusion, after radiofrequency ablation, patients with paroxysmal AF experienced an initial impairment in atrial function, with improvement at longer term follow-up. (C) 2009 Elsevier Inc. All rights reserved. (Am J Cardiol 2009;103: 395-398)
Resumo:
To determine reference values for tissue Doppler imaging (TDI) and pulsed Doppler echocardiography for left ventricular diastolic function analysis in a healthy Brazilian adult population. Observations were based on a randomly selected healthy population from the city of Vitoria, Espirito Santo, Brazil. Healthy volunteers (n = 275, 61.7% women) without prior histories of cardiovascular disease underwent transthoracic echocardiography. We analyzed 175 individuals by TDI and evaluated mitral annulus E`- and A`-waves from the septum (S) and lateral wall (L) to calculate E`/A` ratios. Using pulsed Doppler echocardiography, we further analyzed the mitral E- and A-waves, E/A ratios, isovolumetric relaxation times (IRTs), and deceleration times (DTs) of 275 individuals. Pulsed Doppler mitral inflow mean values for men were as follows: E-wave: 71 +/- 16 cm/sec, A-wave: 68 +/- 15 cm/sec, IRT: 74.8 +/- 9.2 ms, DT: 206 +/- 32.3 ms, E/A ratio: 1.1 +/- 0.3. Pulsed Doppler mitral inflow mean values for women were as follows: E-wave: 76 +/- 17, A-wave: 69 +/- 14 cm/sec, IRT: 71.2 +/- 10.5 ms, DT: 197 +/- 33.3 ms, E/A ratio: 1.1 +/- 0.3. IRT and DT values were higher in men than in women (P = 0.04 and P = 0.007, respectively). TDI values in men were as follows: E`S: 11 +/- 3 cm/sec, A`S: 13 +/- 2 cm/sec, E`S/A`S: 0.89 +/- 0.2, E`L: 14 +/- 3 cm/sec, A`L: 14 +/- 2 cm/sec, E`L/A`L: 1.1 +/- 0.4. E-wave/ E`S ratio: 6.9 +/- 2.2; E-wave / E`L ratio: 4.9 +/- 1.7. In this study, we determined pulsed Doppler and TDI derived parameters for left ventricular diastolic function in a large sample of healthy Brazilian adults. (Echocardiography 2010;27:777-782).
Resumo:
Endomyocardial fibrosis (EMF) is a restrictive cardiomyopathy manifested mainly by diastolic heart failure. It is recognized that diastole is an important determinant of exercise capacity. The purpose of this study was to determine whether resting echocardiographic parameters might predict oxygen consumption (VO(2p)) by ergoespirometry and the prognostic role of functional capacity in EMF patients. A total of 32 patients with biventricular EMF (29 women, 55.3 +/- 11.4 years) were studied by echocardiography and ergoespirometry. The relationship between the echocardiographic indexes and the percentage of predicted VO(2p) (%VO(2p)) was investigated by the `stepwise` linear regression analysis. The median VO(2p) was 11 +/- 3 mL/kg/min and the %VO(2p) was 53 +/- 9%. There was a correlation of %VO(2p) with an average of A` at four sites of the mitral annulus (A` peak, r = 0.471, P = 0.023), E`/A` of the inferior mitral annulus (r = -0.433, P = 0.044), and myocardial performance index (r = -0.352, P = 0.048). On multiple regression analysis, only A` peak was an independent predictor of %VO(2p) (%VO(2p)= 26.34 + 332.44 x A` peak). EMF patients with %VO(2p)< 53% had an increased mortality rate with a relative risk of 8.47. In EMF patients, diastolic function plays an important role in determining the limitations to exercise and %VO(2p) has a prognostic value.
Resumo:
Abnormal left ventricular (IV) filling may occur with increasing age despite apparently normal IV size and function, and is usually attributed to IV hypertrophy and coronary artery disease. The purpose of this study was to determine whether myocardial abnormalities could be identified in 67 such patients (36 men, mean age 57 +/- 9 years) whose IV hypertrophy and coronary artery disease were excluded by dobutamine echocardiography. All patients underwent gray scale and color tissue Doppler imaging from 3 apical views, which were stored and analyzed off line. Disturbances in structure and function were assessed by averaging the cyclic variation of integrated backscatter, strain rate, and peak systolic strain from each myocardial segment. Calibrated integrated backscatter (corrected for pericardial backscatter intensity) was measured in the septum and posterior wall from the parasternal long-axis view. Abnormal IV filling was present in 36 subjects (54%). Subjects with and without abnormal IV filling had similar IV mass, but differed in age (p <0.01), cyclic variation (p = 0.001), strain rate (p <0.01), and peak systolic strain (p <0.001). Multivariate logistic regression analysis demonstrated that age (p = 0.016) and cyclic variation (p = 0.042) were the most important determinants of abnormal IV filling in these apparently normal subjects. (C) 2003 by Excerpta Medica, Inc.