New Self-Expanding Transcatheter Valve for Off-Pump Transatrial Mitral Valve-In-Ring Implantation.
Data(s) |
2015
31/12/1969
|
---|---|
Resumo |
OBJECTIVES To validate a self-expanding transcatheter valve for off-pump transatrial mitral valve-in-ring (VIR) implantation via a left thoracotomy. METHODS Mitral valve annuloplasty was performed via sternotomy during cardiopulmonary bypass on 9 pigs. After successful weaning from extracorporal circulation, the custom-made, self-expanding transcatheter VIR device was deployed under fluoroscopic guidance within the annuloplasty ring via a left thoracotomy. Hemodynamic data before and after the implantation were recorded. Mitral annulus diameter and valve area were measured by echocardiography. Transvalvular and left-ventricular outflow-tract pressure gradient were measured invasively. RESULTS Eight successful implantations were performed. Implantation failed in 1 pig because of difficulty with technical delivery of the sheath. Mean transatrial procedure time was 12.6 ± 1.7 min. Hemodynamic status during transatrial implantation was stable, and differences were not statistically significant. Mean mitral annulus diameter and mean mitral orifice area were 2.32 ± 0.2 and 3.84 ± 0.55 cm2, respectively. Mild regurgitation was detected in 7 animals and moderate regurgitation in 1. Mean gradients were 6.1 ± 5.0 mm Hg across the device. Postmortem examination confirmed adequate positioning of devices within the annuloplasty ring. CONCLUSIONS This custom-made transcatheter device allows for safe and reproducible off-pump transatrial mitral VIR implantations. Transatrial access is a promising route to facilitate VIR implantations. Our custom-made stent-valve may be suitable for VIR procedures. |
Formato |
application/pdf |
Identificador |
http://boris.unibe.ch/74951/1/433595.pdf Ma, Liang; Yu, Zipu; Huber, Christoph; Li, Chengchen; Qian, Linfeng; Jiang, Jianjie; Zou, Yu (2015). New Self-Expanding Transcatheter Valve for Off-Pump Transatrial Mitral Valve-In-Ring Implantation. Cardiology, 132(4), pp. 221-227. Karger 10.1159/000433595 <http://dx.doi.org/10.1159/000433595> doi:10.7892/boris.74951 info:doi:10.1159/000433595 info:pmid:26304619 urn:issn:0008-6312 |
Idioma(s) |
eng |
Publicador |
Karger |
Relação |
http://boris.unibe.ch/74951/ |
Direitos |
info:eu-repo/semantics/openAccess |
Fonte |
Ma, Liang; Yu, Zipu; Huber, Christoph; Li, Chengchen; Qian, Linfeng; Jiang, Jianjie; Zou, Yu (2015). New Self-Expanding Transcatheter Valve for Off-Pump Transatrial Mitral Valve-In-Ring Implantation. Cardiology, 132(4), pp. 221-227. Karger 10.1159/000433595 <http://dx.doi.org/10.1159/000433595> |
Palavras-Chave | #610 Medicine & health |
Tipo |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion PeerReviewed |