951 resultados para Erros de calibração


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pós-graduação em Agronomia (Energia na Agricultura) - FCA

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This work presents a set of intelligent algorithms with the purpose of correcting calibration errors in sensors and reducting the periodicity of their calibrations. Such algorithms were designed using Artificial Neural Networks due to its great capacity of learning, adaptation and function approximation. Two approaches willbe shown, the firstone uses Multilayer Perceptron Networks to approximate the many shapes of the calibration curve of a sensor which discalibrates in different time points. This approach requires the knowledge of the sensor s functioning time, but this information is not always available. To overcome this need, another approach using Recurrent Neural Networks was proposed. The Recurrent Neural Networks have a great capacity of learning the dynamics of a system to which it was trained, so they can learn the dynamics of a sensor s discalibration. Knowingthe sensor s functioning time or its discalibration dynamics, it is possible to determine how much a sensor is discalibrated and correct its measured value, providing then, a more exact measurement. The algorithms proposed in this work can be implemented in a Foundation Fieldbus industrial network environment, which has a good capacity of device programming through its function blocks, making it possible to have them applied to the measurement process

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The aim of this study was to evaluate the evolution of calibration and maintenance practices for crop sprayers on soybean production areas in Brazil, in the 2006 and 2007 seasons, based on the Project IPP data. Therefore, the evaluation covered issues related to calibration, maintenance condition and the main components of 103 sprayers distributed in the following states: Rio Grande do Sul (35), Paraná (60), and, Mato Grosso do Sul (8). The evaluations were done at the rate of one sprayer per farm. The most frequent problems were related to the pressure gauge, spray leaks and calibration errors greater than 50% of the desired volume rate. The analysis of the application rate showed a tendency for the farmers to apply volume rates below the desired value. In 2006 the errors of the application rate were significant, with 70.4% for Rio Grande do Sul State, 74.5% for Paraná State and 37.5% for Mato Grosso do Sul State. In 2007 there was a reduction of errors, with averages of 50.0% for Rio Grande do Sul and 66.7% for Paraná. In general terms, the results showed improvements on the use, maintenance and calibration processes for crop sprayers on the areas covered by the Project IPP, with reductions on average indexes for calibration errors, leaks and bad tips, among other issues.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

O objetivo deste trabalho foi estabelecer um modelo empregando-se ferramentas de regressão multivariada para a previsão do teor em ésteres metílicos e, simultaneamente, de propriedades físico-químicas de misturas de óleo de soja e biodiesel de soja. O modelo foi proposto a partir da correlação das propriedades de interesse com os espectros de reflectância total atenuada no infravermelho médio das misturas. Para a determinação dos teores de ésteres metílicos foi utilizada a cromatografia líquida de alta eficiência (HPLC), podendo esta ser uma técnica alternativa aos método de referência que utilizam a cromatografia em fase gasosa (EN 14103 e EN 14105). As propriedades físico-químicas selecionadas foram índice de refração, massa específica e viscosidade. Para o estudo, foram preparadas 11 misturas com diferentes proporções de biodiesel de soja e de óleo de soja (0-100 % em massa de biodiesel de soja), em quintuplicata, totalizando 55 amostras. A região do infravermelho estudada foi a faixa de 3801 a 650 cm-1. Os espectros foram submetidos aos pré-tratamentos de correção de sinal multiplicativo (MSC) e, em seguida, à centralização na média (MC). As propriedades de interesse foram submetidas ao autoescalamento. Em seguida foi aplicada análise de componentes principais (PCA) com a finalidade de reduzir a dimensionalidade dos dados e detectar a presença de valores anômalos. Quando estes foram detectados, a amostra era descartada. Os dados originais foram submetidos ao algoritmo de Kennard-Stone dividindo-os em um conjunto de calibração, para a construção do modelo, e um conjunto de validação, para verificar a sua confiabilidade. Os resultados mostraram que o modelo proposto por PLS2 (Mínimos Quadrados Parciais) foi capaz de se ajustar bem os dados de índice de refração e de massa específica, podendo ser observado um comportamento aleatório dos erros, indicando a presença de homocedasticidade nos valores residuais, em outras palavras, o modelo construído apresentou uma capacidade de previsão para as propriedades de massa específica e índice de refração com 95% de confiança. A exatidão do modelo foi também avaliada através da estimativa dos parâmetros de regressão que são a inclinação e o intercepto pela Região Conjunta da Elipse de Confiança (EJCR). Os resultados confirmaram que o modelo MIR-PLS desenvolvido foi capaz de prever, simultaneamente, as propriedades índice de refração e massa específica. Para os teores de éteres metílicos determinados por HPLC, foi também desenvolvido um modelo MIR-PLS para correlacionar estes valores com os espectros de MIR, porém a qualidade do ajuste não foi tão boa. Apesar disso, foi possível mostrar que os dados podem ser modelados e correlacionados com os espectros de infravermelho utilizando calibração multivariada

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Este estudo visou à obtenção das curvas de calibração de um equipamento de TDR (Time Domain Reflectometry) em cinco solos da região de Piracicaba, SP, e testou a adequação da calibração interna do equipamento e das curvas genéricas de calibração. As curvas ajustadas, em cada solo separadamente, apresentaram coeficientes de determinação (R²) da ordem de 0,99, e a curva ajustada para o conjunto de dados dos cinco solos apresentou R² = 0,976. A análise de erros-padrão de estimativa mostrou que as curvas genéricas não se prestam às aplicações mais sensíveis, tais como na determinação absoluta do conteúdo de água do solo. Os testes de comparação entre as curvas ajustadas, a curva genérica e a curva embutida no equipamento mostraram que a primeira é superior às demais. O estudo mostrou, também, que a curva de calibração embutida no equipamento é inadequada para as determinações de umidade nos cinco solos estudados.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This work is combined with the potential of the technique of near infrared spectroscopy - NIR and chemometrics order to determine the content of diclofenac tablets, without destruction of the sample, to which was used as the reference method, ultraviolet spectroscopy, which is one of the official methods. In the construction of multivariate calibration models has been studied several types of pre-processing of NIR spectral data, such as scatter correction, first derivative. The regression method used in the construction of calibration models is the PLS (partial least squares) using NIR spectroscopic data of a set of 90 tablets were divided into two sets (calibration and prediction). 54 were used in the calibration samples and the prediction was used 36, since the calibration method used was crossvalidation method (full cross-validation) that eliminates the need for a validation set. The evaluation of the models was done by observing the values of correlation coefficient R 2 and RMSEC mean square error (calibration error) and RMSEP (forecast error). As the forecast values estimated for the remaining 36 samples, which the results were consistent with the values obtained by UV spectroscopy

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper presents a proposal for the automation of the camera calibration process, locating and measuring image points in coded targets with sub-pixel precision. This automatic technique helps minimize localization errors, regardless of camera orientation and image scale. To develop this technique, several types of coded targets were analyzed and the ARUCO type was chosen due to its simplicity, ability to represent up to 1024 different targets and availability of source code implemented with the OpenCV library. ARUCO targets were generated and two calibration sheets were assembled to be used for the acquisition of images for camera calibration. The developed software can locate targets in the acquired images and it automatically extracts the coordinates of the four corners with sub-pixel accuracy. Experiments were conducted with real data showing that the targets are correctly identified unless excessive noise or fragmentation occurs mainly in the outer target square. The results with the calibration of a low cost camera showed that the process works and that the measurement accuracy of the corners achieves sub-pixel precision.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Desenvolve-se um método para estimar os parâmetros de uma rede hidráulica a partir de dados observados de cargas hidráulicas transientes. Os parâmetros físicos da rede como fatores de atrito, rugosidades absolutas, diâmetros e a identificação e quantificação de vazamentos são as grandezas desconhecidas. O problema transiente inverso é resolvido utilizando uma abordagem indireta que compara os dados disponíveis de carga hidráulica transiente observados com os calculados através de um método matemático. O Método Transiente Inverso (MTI) com um Algoritmo Genético (AG) emprega o Método das Características (MOC) na solução das equações do movimento para escoamento transiente em redes de tubos. As condições de regime permanente são desconhecidas. Para avaliar a confiabilidade do MTI-AG desenvolvido aqui, uma rede-exemplo é usada para os vários problemas de calibração propostos. O comportamento transiente é imposto por duas manobras distintas de uma válvula de controle localizada em um dos nós da rede. Analisam-se, ainda, o desempenho do método proposto mediante a variabilidade do tamanho do registro transiente e de possíveis erros de leitura nas cargas hidráulicas. Ensaios numéricos realizados mostram que o método é viável e aplicável à solução de problema inverso em redes hidráulicas, sobretudo recorrendo-se a poucos dados observados e ao desconhecimento das condições iniciais de estado permanente. Nos diversos problemas de identificação, as informações transientes obtidas da manobra mais brusca produziu estimações mais eficientes.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this work, it was developed and validated methodologies that were based on the use of Infrared Spectroscopy Mid (MIR) combined with multivariate calibration Square Partial Least (PLS) to quantify adulterants such as soybean oil and residual soybean oil in methyl and ethyl palm biodiesels in the concentration range from 0.25 to 30.00 (%), as well as to determine methyl and ethyl palm biodiesel content in their binary mixtures with diesel in the concentration range from 0.25 to 30.00 (%). The prediction results showed that PLS models constructed are satisfactory. Errors Mean Square Forecast (RMSEP) of adulteration and content determination showed values of 0.2260 (%), with mean error (EM) with values below 1.93 (%). The models also showed a strong correlation between actual and predicted values, staying above 0.99974. No systematic errors were observed, in accordance to ASTM E1655- 05. Thus the built PLS models, may be a promising alternative in the quality control of this fuel for possible adulterations or to content determination.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The routine analysis for quantization of organic acids and sugars are generally slow methods that involve the use and preparation of several reagents, require trained professional, the availability of special equipment and is expensive. In this context, it has been increasing investment in research whose purpose is the development of substitutive methods to reference, which are faster, cheap and simple, and infrared spectroscopy have been highlighted in this regard. The present study developed multivariate calibration models for the simultaneous and quantitative determination of ascorbic acid, citric, malic and tartaric and sugars sucrose, glucose and fructose, and soluble solids in juices and fruit nectars and classification models for ACP. We used methods of spectroscopy in the near infrared (Near Infrared, NIR) in association with the method regression of partial least squares (PLS). Were used 42 samples between juices and fruit nectars commercially available in local shops. For the construction of the models were performed with reference analysis using high-performance liquid chromatography (HPLC) and refractometry for the analysis of soluble solids. Subsequently, the acquisition of the spectra was done in triplicate, in the spectral range 12500 to 4000 cm-1. The best models were applied to the quantification of analytes in study on natural juices and juice samples produced in the Paraná Southwest Region. The juices used in the application of the models also underwent physical and chemical analysis. Validation of chromatographic methodology has shown satisfactory results, since the external calibration curve obtained R-square value (R2) above 0.98 and coefficient of variation (%CV) for intermediate precision and repeatability below 8.83%. Through the Principal Component Analysis (PCA) was possible to separate samples of juices into two major groups, grape and apple and tangerine and orange, while for nectars groups separated guava and grape, and pineapple and apple. Different validation methods, and pre-processes that were used separately and in combination, were obtained with multivariate calibration models with average forecast square error (RMSEP) and cross validation (RMSECV) errors below 1.33 and 1.53 g.100 mL-1, respectively and R2 above 0.771, except for malic acid. The physicochemical analysis enabled the characterization of drinks, including the pH working range (variation of 2.83 to 5.79) and acidity within the parameters Regulation for each flavor. Regression models have demonstrated the possibility of determining both ascorbic acids, citric, malic and tartaric with successfully, besides sucrose, glucose and fructose by means of only a spectrum, suggesting that the models are economically viable for quality control and product standardization in the fruit juice and nectars processing industry.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Consultoria de Orçamento e Fiscalização Financeira. Núcleo Poderes, Justiça, Relações Exteriores, Defesa e Despesa Pessoal

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Levofloxacino é uma fluorquinolona sintética de 3 geração. É eficaz contra uma variedade de infecções, incluindo o trato respiratório superior e inferior, trato urinário, obstétrico, ginecológico, e infecções dermatológicas. Com o objetivo de quantificar o levofloxacino em medicamentos e amostras de pacientes saudáveis e ter a resolução de seu espectro, foram realizados estudos preliminares em medicamento utilizando espectrofluorescência molecular com concentrações na faixa de 28,8 108 ng/mL e cromatografia líquida de alta eficiência (HPLC) na faixa de concentração de 2,9 10,8 g/mL; e também quantificação em urina de paciente em tratamento com o medicamento, usando os dois métodos citados. Após isso, foram feitos estudos conclusivos utilizando espectrofluorescência molecular e os métodos univariado e PLS para determinação de levofloxacino na faixa de concentração de 0 250 ng/mL e PARAFAC combinado com o método da adição de padrão, para quantificação de levofloxacino em urina de paciente saudável, na faixa de concentração de 0 150 ng/mL, com diluição da amostra em três níveis (100 x, 500 x e 1000x). O método de ordem zero se mostrou mais eficiente na determinação de levofloxacino em medicamento que o de primeira ordem, seus desvios padrão foram 2,0% e 7,9%, respectivamente. Já o PARAFAC com o método de adição de padrão apresentou melhores resultados com a urina, pois possibilitou a quantificação do antibiótico em uma amostra complexa, de forma mais precisa e exata com o aumento da diluição da urina, sem necessidade de tratamento prévio.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Este trabalho apresenta um estudo teórico e numérico sobre os erros que ocorrem nos cálculos de gradientes em malhas não estruturadas constituídas pelo diagrama de Voronoi, malhas estas, formadas também pela triangulação de Delaunay. As malhas adotadas, no trabalho, foram as malhas cartesianas e as malhas triangulares, esta última é gerada pela divisão de um quadrado em dois ou quatro triângulos iguais. Para tal análise, adotamos a escolha de três metodologias distintas para o cálculo dos gradientes: método de Green Gauss, método do Mínimo Resíduo Quadrático e método da Média do Gradiente Projetado Corrigido. O texto se baseia em dois enfoques principais: mostrar que as equações de erros dadas pelos gradientes podem ser semelhantes, porém com sinais opostos, para pontos de cálculos em volumes vizinhos e que a ordem do erro das equações analíticas pode ser melhorada em malhas uniformes quando comparada as não uniformes, nos casos unidimensionais, e quando analisada na face de tais volumes vizinhos nos casos bidimensionais.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Um método numérico nodal livre de erros de truncamento espacial é desenvolvido para problemas adjuntos de transporte de partículas neutras monoenergéticas em geometria unidimensional com fonte fixa na formulação de ordenadas discretas (SN). As incógnitas no método são os fluxos angulares adjuntos médios nos nodos e os fluxos angulares adjuntos nas fronteiras dos nodos, e os valores numéricos gerados para essas quantidades são os obtidos a partir da solução analítica das equações SN adjuntas. O método é fundamentado no uso da convencional equação adjunta SN discretizada de balanço espacial, que é válida para cada nodo de discretização espacial e para cada direção discreta da quadratura angular, e de uma equação auxiliar adjunta não convencional, que contém uma função de Green para os fluxos angulares adjuntos médios nos nodos em termos dos fluxos angulares adjuntos emergentes das fronteiras dos nodos e da fonte adjunta interior. Resultados numéricos são fornecidos para ilustrarem a precisão do método proposto.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Este trabalho de pesquisa descreve dois estudos de caso de métodos quimiométricos empregados para a quantificação de hidrocarbonetos policíclicos aromáticos HPAs (naftaleno, fluoreno, fenantreno e fluoranteno) em água potável usando espectroscopia de fluorescência molecular e a classificação e caracterização de sucos de uva e seus parâmetros de qualidade através de espectroscopia de infravermelho próximo. O objetivo do primeiro estudo é a aplicação combinada de métodos quimiométricos de segunda ordem (N-PLS, U-PLS, U-PLS/RBL e PARAFAC) e espectrofluorimetria para determinação direta de HPAs em água potável, visando contribuir para o conhecimento do potencial destas metodologias como alternativa viável para a determinação tradicional por cromatografia univariada. O segundo estudo de caso destinado à classificação e determinação de parâmetros de qualidade de sucos de uva, densidade relativa e teor de sólidos solúveis totais, foi medida por espectroscopia de infravermelho próximo e métodos quimiométricos. Diversos métodos quimiométricos, tais como HCA, PLS-DA, SVM-DA e SIMCA foram investigados para a classificação amostras de sucos de uva ao mesmo tempo que métodos de calibração multivariada de primeira ordem, tais como PLS, iPLS e SVM-LS foram usadas para a predição dos parâmetros de qualidade. O princípio orientador para o desenvolvimento dos estudos aqui descritos foi a necessidade de metodologias analíticas com custo, tempo de execução e facilidade de operação melhores e menor produção de resíduos do que os métodos atualmente utilizados para a quantificação de HPAs, em água de torneira, e classificação e caracterização das amostras de suco de uva e seus parâmetros de qualidade