663 resultados para Cobas TaqMan HBV
Resumo:
This study aimed to standardise an in-house real-time polymerase chain reaction (rtPCR) to allow quantification of hepatitis B virus (HBV) DNA in serum or plasma samples, and to compare this method with two commercial assays, the Cobas Amplicor HBV monitor and the Cobas AmpliPrep/Cobas TaqMan HBV test. Samples from 397 patients from the state of São Paulo were analysed by all three methods. Fifty-two samples were from patients who were human immunodeficiency virus and hepatitis C virus positive, but HBV negative. Genotypes were characterised, and the viral load was measure in each sample. The in-house rtPCR showed an excellent success rate compared with commercial tests; inter-assay and intra-assay coefficients correlated with commercial tests (r = 0.96 and r = 0.913, p < 0.001) and the in-house test showed no genotype-dependent differences in detection and quantification rates. The in-house assay tested in this study could be used for screening and quantifying HBV DNA in order to monitor patients during therapy.
Resumo:
This study aimed to standardise an in-house real-time polymerase chain reaction (rtPCR) to allow quantification of hepatitis B virus (HBV) DNA in serum or plasma samples, and to compare this method with two commercial assays, the Cobas Amplicor HBV monitor and the Cobas AmpliPrep/Cobas TaqMan HBV test. Samples from 397 patients from the state of São Paulo were analysed by all three methods. Fifty-two samples were from patients who were human immunodeficiency virus and hepatitis C virus positive, but HBV negative. Genotypes were characterised, and the viral load was measure in each sample. The in-house rtPCR showed an excellent success rate compared with commercial tests; inter-assay and intra-assay coefficients correlated with commercial tests (r = 0.96 and r = 0.913, p < 0.001) and the in-house test showed no genotype-dependent differences in detection and quantification rates. The in-house assay tested in this study could be used for screening and quantifying HBV DNA in order to monitor patients during therapy.
Resumo:
BACKGROUND: HIV-1 RNA viral load is a key parameter for reliable treatment monitoring of HIV-1 infection. Accurate HIV-1 RNA quantitation can be impaired by primer and probe sequence polymorphisms as a result of tremendous genetic diversity and ongoing evolution of HIV-1. A novel dual HIV-1 target amplification approach was realized in the quantitative COBAS AmpliPrep/COBAS TaqMan HIV-1 Test, v2.0 (HIV-1 TaqMan test v2.0) to cope with the high genetic diversity of the virus. OBJECTIVES AND STUDY DESIGN: The performance of the new assay was evaluated for sensitivity, dynamic range, precision, subtype inclusivity, diagnostic and analytical specificity, interfering substances, and correlation with the COBAS AmpliPrep/COBAS TaqMan HIV-1 (HIV-1 TaqMan test v1.0) predecessor test in patients specimens. RESULTS: The new assay demonstrated a sensitivity of 20 copies/mL, a linear measuring range of 20-10,000,000 copies/mL, with a lower limit of quantitation of 20 copies/mL. HIV-1 Group M subtypes and HIV-1 Group O were quantified within +/-0.3 log(10) of the assigned titers. Specificity was 100% in 660 tested specimens, no cross reactivity was found for 15 pathogens nor any interference for endogenous substances or 29 drugs. Good comparability with the predecessor assay was demonstrated in 82 positive patient samples. In selected clinical samples 35/66 specimens were found underquantitated in the predecessor assay; all were quantitated correctly in the new assay. CONCLUSIONS: The dual-target approach for the HIV-1 TaqMan test v2.0 enables superior HIV-1 Group M subtype coverage including HIV-1 Group O detection. Correct quantitation of specimens underquantitated in the HIV-1 TaqMan test v1.0 test was demonstrated.
Resumo:
Background: Access to hepatitis B viral load (VL) testing is poor in sub-Saharan Africa (SSA) due toeconomic and logistical reasons.Objectives: To demonstrate the feasibility of testing dried blood spots (DBS) for hepatitis B virus (HBV)VL in a laboratory in Lusaka, Zambia, and to compare HBV VLs between DBS and plasma samples.Study design: Paired plasma and DBS samples from HIV-HBV co-infected Zambian adults were analyzedfor HBV VL using the COBAS AmpliPrep/COBAS TaqMan HBV test (Version 2.0) and for HBV genotypeby direct sequencing. We used Bland-Altman analysis to compare VLs between sample types and bygenotype. Logistic regression analysis was conducted to assess the probability of an undetectable DBSresult by plasma VL.Results: Among 68 participants, median age was 34 years, 61.8% were men, and median plasma HBV VLwas 3.98 log IU/ml (interquartile range, 2.04–5.95). Among sequenced viruses, 28 were genotype A1 and27 were genotype E. Bland–Altman plots suggested strong agreement between DBS and plasma VLs. DBSVLs were on average 1.59 log IU/ml lower than plasma with 95% limits of agreement of −2.40 to −0.83 logIU/ml. At a plasma VL ≥2,000 IU/ml, the probability of an undetectable DBS result was 1.8% (95% CI:0.5–6.6). At plasma VL ≥20,000 IU/ml this probability reduced to 0.2% (95% CI: 0.03–1.7).
Resumo:
In this study, we evaluated the hepatitis B virus (HBV) genotype distribution and HBV genomic mutations among a group of human immunodeficiency virus-HBV co-infected patients from an AIDS outpatient clinic in São Paulo. HBV serological markers were detected by commercially available enzyme immunoassay kits. HBV DNA was detected using in-house nested polymerase chain reaction and quantified by Cobas Amplicor. HBV genotypes and mutations in the basal core promoter (BCP)/pre-core/core regions and surface/polymerase genes were determined by sequencing. Among the 59 patients included in this study, 55 reported prior use of lamivudine (LAM) or tenofovir. HBV DNA was detected in 16/22 patients, with a genotype distribution of A (n = 12,75%), G (n = 2,13%), D (n = 1,6%) and F (n = 1,6%). The sequence data of the two patients infected with genotype G strongly suggested co-infection with genotype A. In 10 patients with viremia, LAM-resistance mutations in the polymerase gene (rtL180M + rtM204V and rtV173L + rtL180M + rtM204V) were found, accompanied by changes in the envelope gene (sI195M, sW196L and sI195M/sE164D). Mutations in the BCP and pre-core regions were identified in four patients. In conclusion, genotype G, which is rarely seen in Brazil, was observed in the group of patients included in our study. A high prevalence of mutations associated with LAM-resistance and mutations associated with anti-HBs resistance were also found among these patients.
Resumo:
Introduction: HIV-1 viral escape in the cerebrospinal fluid (CSF) despite viral suppression in plasma is rare [1,2]. We describe the case of a 50-year-old HIV-1 infected patient who was diagnosed with HIV-1 in 1995. Antiretroviral therapy (ART) was started in 1998 with a CD4 T cell count of 71 cells/ìL and HIV-viremia of 46,000 copies/mL. ART with zidovudine (AZT), lamivudine (3TC) and efavirenz achieved full viral suppression. After the patient had interrupted ART for two years, treatment was re-introduced with tenofovir (TDF), emtricitabin (FTC) and ritonavir boosted atazanavir (ATVr). This regimen suppressed HIV-1 in plasma for nine years and CD4 cells stabilized around 600 cells/ìL. Since July 2013, the patient complained about severe gait ataxia and decreased concentration. Materials and Methods: Additionally to a neurological examination, two lumbar punctures, a cerebral MRI and a neuropsycological test were performed. HIV-1 viral load in plasma and in CSF was quantified using Cobas TaqMan HIV-1 version 2.0 (Cobas Ampliprep, Roche diagnostic, Basel, Switzerland) with a detection limit of 20 copies/mL. Drug resistance mutations in HIV-1 reverse transcriptase and protease were evaluated using bulk sequencing. Results: The CSF in January 2014 showed a pleocytosis with 75 cells/ìL (100% mononuclear) and 1,184 HIV-1 RNA copies/mL, while HIV-1 in plasma was below 20 copies/mL. The resistance testing of the CSF-HIV-1 RNA showed two NRTI resistance-associated mutations (M184V and K65R) and one NNRTI resistance-associated mutation (K103N). The cerebral MRI showed increased signal on T2-weighted images in the subcortical and periventricular white matter, in the basal ganglia and thalamus. Four months after ART intensification with AZT, 3TC, boosted darunavir and raltegravir, the pleocytosis in CSF cell count normalized to 1 cell/ìL and HIV viral load was suppressed. The neurological symptoms improved; however, equilibrium disturbances and impaired memory persisted. The neuro-psychological evaluation confirmed neurocognitive impairments in executive functions, attention, working and nonverbal memory, speed of information processing, visuospatial abilities and motor skills. Conclusions: HIV-1 infected patients with neurological complaints prompt further investigations of the CSF including measurement of HIV viral load and genotypic resistance testing since isolated replication of HIV with drug resistant variants can rarely occur despite viral suppression in plasma. Optimizing ART by using drugs with improved CNS penetration may achieve viral suppression in CSF with improvement of neurological symptoms.
Resumo:
218 p.
A real-time quantitative assay for hepatitis B DNA virus (HBV) developed to detect all HBV genotypes
Resumo:
Hepatitis B virus (HBV) is a major cause of chronic liver disease worldwide. Besides genotype, quantitative analysis of HBV infection is extensively used for monitoring disease progression and treatment. Affordable viral load monitoring is desirable in resource-limited settings and it has been already shown to be useful in developing countries for other viruses such as Hepatitis C virus (HCV) and HIV. In this paper, we describe the validation of a real-time PCR assay for HBV DNA quantification with TaqMan chemistry and MGB probes. Primers and probes were designed using an alignment of sequences from all HBV genotypes in order to equally amplify all of them. The assay is internally controlled and was standardized with an international HBV panel. Its efficacy was evaluated comparing the results with two other methods: Versant HBV DNA Assay 3.0 (bDNA, Siemens, NY, USA) and another real-time PCR from a reference laboratory. Intra-assay and inter-assay reproducibilities were determined and the mean of CV values obtained were 0.12 and 0.09, respectively. The assay was validated with a broad dynamic range and is efficient for amplifying all HBV genotypes, providing a good option to quantify HBV DNA as a routine procedure, with a cheap and reliable protocol.
Resumo:
Aim: To rapidly quantify hepatitis B virus (HBV) DNA by real-time PCR using efficient TaqMan probe and extraction methods of virus DNA. Methods: Three standards were prepared by cloning PCR products which targeted S, C and X region of HBV genome into pGEM-T vector respectively. A pair of primers and matched TaqMan probe were selected by comparing the copy number and the Ct values of HBV serum samples derived from the three different standard curves using certain serum DNA. Then the efficiency of six HBV DNA extraction methods including guanidinium isothiocyanate, proteinase K, NaI, NaOH lysis, alkaline lysis and simple boiling was analyzed in sample A, B and C by real-time PCR. Meanwhile, 8 clinical HBV serum samples were quantified. Results: The copy number of the same HBV serum sample originated from the standard curve of S, C and X regions was 5.7 × 104/ mL, 6.3 × 102/mL and 1.6 × 103/mL respectively. The relative Ct value was 26.6, 31.8 and 29.5 respectively. Therefore, primers and matched probe from S region were chosen for further optimization of six extraction methods. The copy number of HBV serum samples A, B and C was 3.49 × 109/mL, 2.08 × 106/mL and 4.40 × 107/mL respectively, the relative Ct value was 19.9, 30 and 26.2 in the method of NaOH lysis, which was the efficientest among six methods. Simple boiling showed a slightly lower efficiency than NaOH lysis. Guanidinium isothiocyanate, proteinase K and NaI displayed that the copy number of HBV serum sample A, B and C was around 105/ mL, meanwhile the Ct value was about 30. Alkaline failed to quantify the copy number of three HBV serum samples, Standard deviation (SD) and coefficient variation (CV) were very low in all 8 clinical HBV serum samples, showing that quantification of HBV DNA in triplicate was reliable and accurate. Conclusion: Real-time PCR based on optimized primers and TaqMan probe from S region in combination with NaOH lysis is a simple, rapid and accurate method for quantification of HBV serum DNA. © 2006 The WJG Press. All rights reserved.
Resumo:
Background: Hepatitis B virus (HBV) can be classified into nine genotypes (A-I) defined by sequence divergence of more than 8% based on the complete genome. This study aims to identify the genotypic distribution of HBV in 40 HBsAg-positive patients from Rondonia, Brazil. A fragment of 1306 bp partially comprising surface and polymerase overlapping genes was amplified by PCR. Amplified DNA was purified and sequenced. Amplified DNA was purified and sequenced on an ABI PRISM (R) 377 Automatic Sequencer (Applied Biosystems, Foster City, CA, USA). The obtained sequences were aligned with reference sequences obtained from the GenBank using Clustal X software and then edited with Se-Al software. Phylogenetic analyses were conducted by the Markov Chain Monte Carlo (MCMC) approach using BEAST v.1.5.3. Results: The subgenotypes distribution was A1 (37.1%), D3 (22.8%), F2a (20.0%), D4 (17.1%) and D2 (2.8%). Conclusions: These results for the first HBV genotypic characterization in Rondonia state are consistent with other studies in Brazil, showing the presence of several HBV genotypes that reflects the mixed origin of the population, involving descendants from Native Americans, Europeans, and Africans.
Resumo:
Background: GB virus C (GBV-C) is an enveloped positive-sense ssRNA virus belonging to the Flaviviridae family. Studies on the genetic variability of the GBV-C reveals the existence of six genotypes: genotype 1 predominates in West Africa, genotype 2 in Europe and America, genotype 3 in Asia, genotype 4 in Southwest Asia, genotype 5 in South Africa and genotype 6 in Indonesia. The aim of this study was to determine the frequency and genotypic distribution of GBV-C in the Colombian population. Methods: Two groups were analyzed: i) 408 Colombian blood donors infected with HCV (n = 250) and HBV (n = 158) from Bogota and ii) 99 indigenous people with HBV infection from Leticia, Amazonas. A fragment of 344 bp from the 5' untranslated region (5' UTR) was amplified by nested RT PCR. Viral sequences were genotyped by phylogenetic analysis using reference sequences from each genotype obtained from GenBank (n = 160). Bayesian phylogenetic analyses were conducted using Markov chain Monte Carlo (MCMC) approach to obtain the MCC tree using BEAST v. 1.5.3. Results: Among blood donors, from 158 HBsAg positive samples, eight 5.06% (n = 8) were positive for GBV-C and from 250 anti-HCV positive samples, 3.2%(n = 8) were positive for GBV-C. Also, 7.7% (n = 7) GBV-C positive samples were found among indigenous people from Leticia. A phylogenetic analysis revealed the presence of the following GBV-C genotypes among blood donors: 2a (41.6%), 1 (33.3%), 3 (16.6%) and 2b (8.3%). All genotype 1 sequences were found in co-infection with HBV and 4/5 sequences genotype 2a were found in co-infection with HCV. All sequences from indigenous people from Leticia were classified as genotype 3. The presence of GBV-C infection was not correlated with the sex (p = 0.43), age (p = 0.38) or origin (p = 0.17). Conclusions: It was found a high frequency of GBV-C genotype 1 and 2 in blood donors. The presence of genotype 3 in indigenous population was previously reported from Santa Marta region in Colombia and in native people from Venezuela and Bolivia. This fact may be correlated to the ancient movements of Asian people to South America a long time ago.
Resumo:
Background: Viral hepatitis B, C and delta still remain a serious problem worldwide. In Colombia, data from 1980s described that HBV and HDV infection are important causes of hepatitis, but little is known about HCV infection. The aim of this study was to determine the currently frequency of HBV, HCV and HDV in four different Colombian regions. Methodology/Principal Findings: This study was conducted in 697 habitants from 4 Colombian departments: Amazonas, Choco, Magdalena and San Andres Islands. Epidemiological data were obtained from an interview applied to each individual aiming to evaluate risk factors related to HBV, HCV or HDV infections. All samples were tested for HBsAg, anti-HBc, anti-HBs and anti-HCV markers. Samples that were positive to HBsAg and/or anti-HBc were tested to anti-HDV. Concerning the geographical origin of the samples, the three HBV markers showed a statistically significant difference: HBsAg (p = 0.033) and anti-HBc (p < 0.001) were more frequent in Amazonas and Magdalena departments. Isolated anti-HBs (a marker of previous vaccination) frequencies were: Choco (53.26%), Amazonas (32.88%), Magdalena (17.0%) and San Andres (15.33%) p < 0.001. Prevalence of anti-HBc increased with age; HBsAg varied from 1.97 to 8.39% (p = 0.033). Amazonas department showed the highest frequency for anti-HCV marker (5.68%), while the lowest frequency was found in San Andres Island (0.66%). Anti-HDV was found in 9 (5.20%) out of 173 anti-HBc and/or HBsAg positive samples, 8 of them from the Amazonas region and 1 from them Magdalena department. Conclusions/Significance: In conclusion, HBV, HCV and HDV infections are detected throughout Colombia in frequency levels that would place some areas as hyperendemic for HBV, especially those found in Amazonas and Magdalena departments. Novel strategies to increase HBV immunization in the rural population and to strengthen HCV surveillance are reinforced by these results.
Resumo:
Background: Prolonged use of lamivudine in patients coinfected with HIV and hepatitis B virus (HBV) leads to an increasing risk of lamivudine resistance in both diseases. We investigated the addition of entecavir, a potent inhibitor of HBV polymerase, to lamivudine-containing highly active antiretroviral therapy (HAART) in patients who experienced rebound in HBV viremia while maintaining Suppression of plasma HIV RNA less than 400 copies/ml. Methods: Sixty-eight patients were randomized to entecavir 1 mg (n = 51) or placebo (n = 17) once daily for 24 weeks; 65 patients continued the study with entecavir for an additional 24 weeks. Lamivudine-containing HAART was continued throughout. Results: At week 24, the mean HBV DNA in entecavir-treated patients was 5.52 log(10) - copies/ml versus 9.27 log(10) copies/ml for placebo, and at week 48, it was 4.79log(10) copies/ml versus 5.63log(10) copies/ml, respectively. The mean HBV DNA change from baseline for entecavir was -3.65 log(10) copies/ml (versus + 0.11 for placebo, P < 0.0001) and alanine aminotransferase normalization in 34%. of patients (versus 8% for placebo, P=0.08)At 48 weeks, mean change in HBV DNA reached -4.20log(10) copies/ml inpatients who received entecavir for the entire 48 weeks. The frequency of adverse events with entecavir and placebo was comparable. Through 48 weeks, no clinically relevant changes in HIV viremia or CD4 cell Counts were identified. Conclusion: In this study, entecavir was associated with rapid, clinically significant reductions in HBV DNA, with maintenance of HIV viremia suppression, in HIV/HBV coinfected patients with HBV viremia while on lamivudine treatment. (C) 2008 Wolters Kluwer Health vertical bar Lippincott Williams & Wilkins.
Resumo:
Hepatitis C is one of the most common chronic infectious diseases worldwide, with well-documented extra-hepatic manifestations, such as a broad number of cognitive deficits. These impairments may be explained by psychiatric comorbidities, which have not been investigated properly in the literature. In order to elucidate a specific hepatitis C virus (HCV) induced cognitive impairment not related to mental disorders, neuropsychological performance of patients infected with HCV was compared with that of patients infected with hepatitis B virus cognitive impairment, especially psychiatric comorbidities. A total of 33 patients infected with HCV and 22 patients infected with HBV were included in the study. There were no significant differences between the two groups with regard to age or years of education. The group of patients infected with HCV performed significantly worse on visuo-spatial memory tasks after adjusting for years of education and age. There were no significant differences between patients infected with HCV and patients infected with HBV with regards to other neuropsychological functions. The data indicate that patients infected with HCV patients have poorer visuo-spacial memory performance than patients infected with HBV, suggesting that the cognitive deficit may be specific to HCV infection and not to secondary comorbid psychiatric disorders. J. Med. Virol. 81: 1184-1188, 2009. (C) 2009 Wiley-Liss, Inc.
Resumo:
Schedule for vaccination against HBV infection has usually been based on three separate injections of 20 meg of the vaccine by intramuscular route. One of the main shortcomings to its use in large scale programs has been its high cost. Ninety out of 300 health workers were submitted to three injections of 2 meg of plasma-derived vaccine (PDV) by intradermal (ID) route on days 0, 30, and 180. Anti-HBs was detected in 74 (82.2%) after the second dose and in 80 (88.9%) after the third dose, a non-significant difference. However, levels above 10 times the cut-off were observed in 29 (32.2%) and 77 (85.5%), respectively (p < 0.001). The results showed that a low-dose schedule is effective when used in health workers and should be tried with other risk groups.