11 resultados para Above-Threshold Ionization
em Repositório da Produção Científica e Intelectual da Unicamp
Resumo:
Knowledge of the major effects governing desorption/ionization efficiency is required for the development and application of ambient mass spectrometry. Although all triacylglycerols (TAG) have the same favorable protonation and cationization sites, their desorption/ionization efficiencies can vary dramatically during easy ambient sonic-spray ionization because of structural differences in the carbon chain. To quantify this somewhat surprising and drastic effect, we have performed a systematic investigation of desorption/ionization efficiencies as a function of unsaturation and length for TAG as well as for diacylglycerols, monoacylglycerols and several phospholipids (PL). Affinities for Na(+) as a function of unsaturation level have also been assayed via comprehensive metadynamics calculations to understand the influence of this phenomenon on the ionization efficiency. The results suggest that dipole-dipole interactions within a carbon chain tuned by unsaturation sites govern ionization efficiency of TAG and PL.
Resumo:
Negative-ion mode electrospray ionization, ESI(-), with Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS) was coupled to a Partial Least Squares (PLS) regression and variable selection methods to estimate the total acid number (TAN) of Brazilian crude oil samples. Generally, ESI(-)-FT-ICR mass spectra present a power of resolution of ca. 500,000 and a mass accuracy less than 1 ppm, producing a data matrix containing over 5700 variables per sample. These variables correspond to heteroatom-containing species detected as deprotonated molecules, [M - H](-) ions, which are identified primarily as naphthenic acids, phenols and carbazole analog species. The TAN values for all samples ranged from 0.06 to 3.61 mg of KOH g(-1). To facilitate the spectral interpretation, three methods of variable selection were studied: variable importance in the projection (VIP), interval partial least squares (iPLS) and elimination of uninformative variables (UVE). The UVE method seems to be more appropriate for selecting important variables, reducing the dimension of the variables to 183 and producing a root mean square error of prediction of 0.32 mg of KOH g(-1). By reducing the size of the data, it was possible to relate the selected variables with their corresponding molecular formulas, thus identifying the main chemical species responsible for the TAN values.
Resumo:
Corynebacterium species (spp.) are among the most frequently isolated pathogens associated with subclinical mastitis in dairy cows. However, simple, fast, and reliable methods for the identification of species of the genus Corynebacterium are not currently available. This study aimed to evaluate the usefulness of matrix-assisted laser desorption ionization/mass spectrometry (MALDI-TOF MS) for identifying Corynebacterium spp. isolated from the mammary glands of dairy cows. Corynebacterium spp. were isolated from milk samples via microbiological culture (n=180) and were analyzed by MALDI-TOF MS and 16S rRNA gene sequencing. Using MALDI-TOF MS methodology, 161 Corynebacterium spp. isolates (89.4%) were correctly identified at the species level, whereas 12 isolates (6.7%) were identified at the genus level. Most isolates that were identified at the species level with 16 S rRNA gene sequencing were identified as Corynebacterium bovis (n=156; 86.7%) were also identified as C. bovis with MALDI-TOF MS. Five Corynebacterium spp. isolates (2.8%) were not correctly identified at the species level with MALDI-TOF MS and 2 isolates (1.1%) were considered unidentified because despite having MALDI-TOF MS scores >2, only the genus level was correctly identified. Therefore, MALDI-TOF MS could serve as an alternative method for species-level diagnoses of bovine intramammary infections caused by Corynebacterium spp.
Resumo:
A retrospective case-control study based on craniometrical evaluation was performed to evaluate the incidence of basilar invagination (BI). Patients with symptomatic tonsillar herniation treated surgically had craniometrical parameters evaluated based on CT scan reconstructions before surgery. BI was diagnosed when the tip of the odontoid trespassed the Chamberlain's line in three different thresholds found in the literature: 2, 5 or 6.6 mm. In the surgical group (SU), the mean distance of the tip of the odontoid process above the Chamberlain's line was 12 mm versus 1.2 mm in the control (CO) group (p<0.0001). The number of patients with BI according to the threshold used (2, 5 or 6.6 mm) in the SU group was respectively 19 (95%), 16 (80%) and 15 (75%) and in the CO group it was 15 (37%), 4 (10%) and 2 (5%).
Resumo:
Using a desorption/ionization technique, easy ambient sonic-spray ionization coupled to mass spectrometry (EASI-MS), documents related to the 2nd generation of Brazilian Real currency (R$) were screened in the positive ion mode for authenticity based on chemical profiles obtained directly from the banknote surface. Characteristic profiles were observed for authentic, seized suspect counterfeit and counterfeited homemade banknotes from inkjet and laserjet printers. The chemicals in the authentic banknotes' surface were detected via a few minor sets of ions, namely from the plasticizers bis(2-ethylhexyl)phthalate (DEHP) and dibutyl phthalate (DBP), most likely related to the official offset printing process, and other common quaternary ammonium cations, presenting a similar chemical profile to 1st-generation R$. The seized suspect counterfeit banknotes, however, displayed abundant diagnostic ions in the m/z 400-800 range due to the presence of oligomers. High-accuracy FT-ICR MS analysis enabled molecular formula assignment for each ion. The ions were separated by 44 m/z, which enabled their characterization as Surfynol® 4XX (S4XX, XX=40, 65, and 85), wherein increasing XX values indicate increasing amounts of ethoxylation on a backbone of 2,4,7,9-tetramethyl-5-decyne-4,7-diol (Surfynol® 104). Sodiated triethylene glycol monobutyl ether (TBG) of m/z 229 (C10H22O4Na) was also identified in the seized counterfeit banknotes via EASI(+) FT-ICR MS. Surfynol® and TBG are constituents of inks used for inkjet printing.
Resumo:
Pain is a common complaint in women with endometriosis and can be influenced by many variables, including sleep disorders; however, no data are available on the sleep quality of women with endometriosis or on the correlation between sleep quality and pain. The 510 volunteers included in this study were divided into two groups: 257 women with a laparoscopic and histopathological diagnosis of endometriosis and 253 women with no history of endometriosis and no endometriosis-related symptoms. The volunteers answered two questionnaires: the Post-Sleep Inventory to evaluate sleep quality and the International Physical Activity Questionnaire to assess their level of physical activity. Pain was evaluated using a visual analogue scale (VAS) and women were also submitted to a physical examination, during which their pain threshold was assessed at 20 different body sites. Sleep quality was significantly poorer in women with endometriosis compared to women without the disease. The pain threshold was significantly lower in the greater trochanter and abdomen in women with endometriosis when compared to women without the disease; however, there was no difference in VAS pain score between the groups. The higher the VAS pain score, the lower the Post-Sleep Inventory score. Additionally, there was a significant positive correlation between the pain threshold at some body sites and sleep quality. Sleep quality was poorer and the pain threshold at certain body sites was lower in the group of women with endometriosis.
Resumo:
Matrix-assisted laser desorption/ionization time-of flight mass spectrometry (MALDI-TOF MS) has been widely used for the identification and classification of microorganisms based on their proteomic fingerprints. However, the use of MALDI-TOF MS in plant research has been very limited. In the present study, a first protocol is proposed for metabolic fingerprinting by MALDI-TOF MS using three different MALDI matrices with subsequent multivariate data analysis by in-house algorithms implemented in the R environment for the taxonomic classification of plants from different genera, families and orders. By merging the data acquired with different matrices, different ionization modes and using careful algorithms and parameter selection, we demonstrate that a close taxonomic classification can be achieved based on plant metabolic fingerprints, with 92% similarity to the taxonomic classifications found in literature. The present work therefore highlights the great potential of applying MALDI-TOF MS for the taxonomic classification of plants and, furthermore, provides a preliminary foundation for future research.
Resumo:
PURPOSE: To compare the Full Threshold (FT) and SITA Standard (SS) strategies in glaucomatous patients undergoing automated perimetry for the first time. METHODS: Thirty-one glaucomatous patients who had never undergone perimetry underwent automated perimetry (Humphrey, program 30-2) with both FT and SS on the same day, with an interval of at least 15 minutes. The order of the examination was randomized, and only one eye per patient was analyzed. Three analyses were performed: a) all the examinations, regardless of the order of application; b) only the first examinations; c) only the second examinations. In order to calculate the sensitivity of both strategies, the following criteria were used to define abnormality: glaucoma hemifield test (GHT) outside normal limits, pattern standard deviation (PSD) <5%, or a cluster of 3 adjacent points with p<5% at the pattern deviation probability plot. RESULTS: When the results of all examinations were analyzed regardless of the order in which they were performed, the number of depressed points with p<0.5% in the pattern deviation probability map was significantly greater with SS (p=0.037), and the sensitivities were 87.1% for SS and 77.4% for FT (p=0.506). When only the first examinations were compared, there were no statistically significant differences regarding the number of depressed points, but the sensitivity of SS (100%) was significantly greater than that obtained with FT (70.6%) (p=0.048). When only the second examinations were compared, there were no statistically significant differences regarding the number of depressed points, and the sensitivities of SS (76.5%) and FT (85.7%) (p=0.664). CONCLUSION: SS may have a higher sensitivity than FT in glaucomatous patients undergoing automated perimetry for the first time. However, this difference tends to disappear in subsequent examinations.
Resumo:
Universidade Estadual de Campinas . Faculdade de Educação Física
Resumo:
Universidade Estadual de Campinas. Faculdade de Educação Física
Resumo:
Universidade Estadual de Campinas . Faculdade de Educação Física