29 resultados para tungsten coil

em Scielo Saúde Pública - SP


Relevância:

100.00% 100.00%

Publicador:

Resumo:

A flow system coupled to a tungsten coil atomizer in an atomic absorption spectrometer (TCA-AAS) was developed for As(III) determination in waters, by extraction with sodium diethyldithiocarbamate (NaDDTC) as complexing agent, and by sorption of the As(III)-DDTC complex in a micro-column filled with 5 mg C18 reversed phase (10 µL dry sorbent), followed by elution with ethanol. A complete pre-concentration/elution cycle took 208 s, with 30 s sample load time (1.7 mL) and 4 s elution time (71 µL). The interface and software for the synchronous control of two peristaltic pumps (RUN/ STOP), an autosampler arm, seven solenoid valves, one injection valve, the electrothermal atomizer and the spectrometer Read function were constructed. The system was characterized and validated by analytical recovery studies performed both in synthetic solutions and in natural waters. Using a 30 s pre-concentration period, the working curve was linear between 0.25 and 6.0 µg L-1 (r = 0.9976), the retention efficiency was 94±1% (6.0 µg L-1), and the pre-concentration coefficient was 28.9. The characteristic mass was 58 pg, the mean repeatability (expressed as the variation coefficient) was 3.4% (n=5), the detection limit was 0.058 µg L-1 (4.1 pg in 71 µL of eluate injected into the coil), and the mean analytical recovery in natural waters was 92.6 ± 9.5 % (n=15). The procedure is simple, economic, less prone to sample loss and contamination and the useful lifetime of the micro-column was between 200-300 pre-concentration cycles.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The interface and software for synchronous control of an autosampler and an electrothermal tungsten coil atomizer in atomic absorption spectrophotometry were developed. The control of the power supply, the trigger of the Read function of the spectrophotometer and the automatic operation of the autosampler was performed by software written in "TurboBasic". The system was evaluated by comparison of the repeatability of peak-height absorbances obtained in the atomization of lead by consecutive 10-µl injections of solutions (prepared in 0.2% v/v HNO3) using autosampler and manual sample introduction, and also by long term operation.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A tungsten coil atomizer was used to investigate the effect of heating programs with constant or variable drying temperatures on the atomization of Al, Cd, Cr and Pb. The variation of the surface temperature in the tungsten coil furnace can occur during each heating step due to the design of the power supply, that may apply constant voltages during a programmed time. For volatile elements (Cd), losses in sensitivity were observed when the program with a variable temperature was used. On the other hand, these effects are negligible for less volatile elements (Al and Cr) and any tested program, in different acidic media, could be used without appreciable changes in sensitivities. The results allow the establishment of proper heating programs for elements with different thermochemical behavior in the tungsten coil atomizer.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In this review it is presented some aspects of electrothermal atomic absorption spectrometry with tungsten coil (ETAW-AAS) since its beginning until the present days as well as the perspectives for this technique. Some aspects concerning its development and theoretical concepts are discussed. The analytical figures of merit such as limit of detection (LD), characteristic mass (m0), relative standard deviation (RSD), accuracy and precision are evaluated, compared and discussed considering published works. It is also evaluated its advantages, applications, limitations and instrumental development. The use of diode laser as radiation source and its perspectives to ETAW are also discussed.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

It is here discussed the development of a low cost analytical instrument with capacity for metals determination using atomic emission measurements in an electrothermal atomization system with a tungsten coil atomizer. The main goal was to show a new frontier for using this atomizer and to demonstrate that the simple instrumental arrangement here proposed has potential for portability and for solving analytical tasks related to metals determination. Atomic emission of calcium was selected for the adjustment of instrumental parameters and to evaluate the main characteristics of the lab-built instrument. Cobalt was determined in medicines and one alloy to demonstrate its feasibility.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abstract Objective: Derive filtered tungsten X-ray spectra used in digital mammography systems by means of Monte Carlo simulations. Materials and Methods: Filtered spectra for rhodium filter were obtained for tube potentials between 26 and 32 kV. The half-value layer (HVL) of simulated filtered spectra were compared with those obtained experimentally with a solid state detector Unfors model 8202031-H Xi R/F & MAM Detector Platinum and 8201023-C Xi Base unit Platinum Plus w mAs in a Hologic Selenia Dimensions system using a direct radiography mode. Results: Calculated HVL values showed good agreement as compared with those obtained experimentally. The greatest relative difference between the Monte Carlo calculated HVL values and experimental HVL values was 4%. Conclusion: The results show that the filtered tungsten anode X-ray spectra and the EGSnrc Monte Carlo code can be used for mean glandular dose determination in mammography.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Low-cost tungsten monometallic catalysts containing variable amounts of metal (4.5, 7.1 and 8.5%W) were prepared by impregnating alumina with ammonium metatungstate as an inexpensive precursor. The catalysts were characterized using ICP, XPS, XRD, TPR and hydrogen chemisorption. These techniques revealed mainly WO3-Al2O3 (W6+) species on the surface. The effects of the content of W nanoparticles and reaction temperature on activity and selectivity for the partial hydrogenation of 3-hexyne, a non-terminal alkyne, were assessed under moderate conditions of temperature and pressure. The monometallic catalysts prepared were found to be active and stereoselective for the production of (Z )-3-hexene, had the following order: 7.1WN/A > 8.5 WN/A ≥ 4.5 WN/A. Additionally, the performance of the synthesized xWN/A catalysts exhibited high sensitivity to temperature variation. In all cases, the maximum 3-hexyne total conversion and selectivity was achieved at 323 K. The performance of the catalysts was considered to be a consequence of two phenomena: a) the electronic effects, related to the high charge of W (+6), causing an intensive dipole moment in the hydrogen molecule (van der Waals forces) and leading to heterolytic bond rupture; the H+ and H- species generated approach a 3-hexyne adsorbate molecule and cause heterolytic rupture of the C≡C bond into C- = C+; and b) steric effects related to the high concentration of WO3 on 8.5WN/A that block the Al2O3 support. Catalyst deactivation was detected, starting at about 50 min of reaction time. Electrodeficient W6+ species are responsible for the formation of green oil at the surface level, blocking pores and active sites of the catalyst, particularly at low reaction temperatures (293 and 303 K). The resulting best catalyst, 7.1WN/A, has low fabrication cost and high selectivity for (Z )-3-hexene (94%) at 323 K. This selectivity is comparable to that of the classical and more expensive industrial Lindlar catalyst (5 wt% Pd). The alumina supported tungsten catalysts are low-cost potential replacements for the Lindlar industrial catalyst. These catalysts could also be used for preparing bimetallic W-Pd catalysts for selective hydrogenation of terminal and non-terminal alkynes.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Boiruna maculata Boulenger, 1896 and Clelia rustica (Cope, 1878) were observed in captivity feeding snakes and rodents, respectively. Both species have shown a similar procedure in relation to the prey. Major behavior differences among the two species were: rodents killed before being swallowed, and snakes were mostly swallowed alive; both species are able to find the rodents head faster than the snake one; the coils formed during constriction were also used to hold the prey, specially the last coil, while swallowing rodents. Informations on stomach contents was gathered by dissection of preserved specimens of Clelia clelia (Daudin, 1803) and C. plumbea (Wied, 1820) were also included in the dietary study. The majority of preys consisted on snakes and lizards. Other prey items were mammals and birds. Adult snakes prey relatively smaller animals than the juvenile snakes do.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The author has studied the influence of acetylcholine solutions directly applied on the motor cortex of dogs, cats monkeys and rabbits. For this purpose small squares of filter paper were soaked in the acetylcholine solution and soon afterwards laid on the motor cortex. Solutions varying from 0,2 to 10 per cent have been experimented. It has been shown that local application of the solutions on the motor points, previously localized by induction coil, produced motor reactions. It has been found, in the dogs that 10 per cent acetylcholine solutions cause localized muscular twitchings (clonus) in almost all the animals experimented. Generalised epileptiform convulsions were obtained in44,4% of the dogs. Convulsions were also obtained by employing 1 per cent solution of acetylcholine. Definite response has been obtained with 0,2 per cent solution. Failure of motor action, pointed out by other authors, has been related to the use of anesthetics. Convulsions were easily produced by rapid light mechanical stimulations of the skin covering the muscles in conection with the excited motor point, and the application on the motor point of acetylcholine. The results on monkeys can be summarized as follows. Two species of monkeys were experimented: Cebus capucinus and Macaca mulata. In the monkeys C. capucinus generalised convulsive reactions were induced with actylcholine solutions in a concentration as low as 0,5 per cent. Motor reaction or convulsive seizeres were obtained in seven of the eight monkeys used. Three monkeys M. mulata were stimulated with 10 per cent acetylcholine solution but only localized muscular contraction hae been observed. Similar results has been obtained on the motor cortex of cats and rabbits. One of the three cats employed has shown epileptiform convulsions and the remaining only localized muscular contractions. In the rabbits muscular twitchings have been also induced. The sensitizing power of eserine on the action of acetylcholine has been also searched. The results indicate that a previous application of eserine solution on the motor center, potentiates the action of acetylcholine. The intensity of the muscular twitchings is greater than the obtained before the application of the eserine solution. Generalised epileptiform convulsions sometimes appeared following the use of lower concentrations of acetylcholine than those previously employed. Experiments have been carried out by injecting eserine and prostigmine by parenteral route. A dosis dufficient for induce small muscular tremors did not enhance obviously the motor effects produced by the application of the acetylcholine solutions on the motor cortex. From seven dogs experimented, all previously tested for convulsive seiruzes by application of 1 and 10 per cent acetylcholine solution with negative results, only one has shown epileptiform convulsions after the injection of prostigmine. Morphine has also been tested as facilitating substance for convulsions induced by acetylcholine. Six from the nine dogs submitted to the experiments, developed epileptiform seizures after injection of morphine and stimulation of the motor cortex with acetylcholine. (Table IV). In another series of experiments atropine and nicotine have been studied as for to their action on the motor effects of acetylcholine. Nicotine has a strong convulsant action, even when employed in very high concentration. Since a depressant effect has not appeared even by the applications of high concentrations of nicotine in the motor corteõ of dogs, unlike the classical observations for the autonomus nervous system, it was not possible to verify the action of acetylcholine on a motor center paralised by nicotine. It is important to not that the motor phenomena observed after the first aplication of acetylcholine, can desappear by the renewal of the pieces of filter paper soaked in the acetylcholine solution. Atropine, either applied on the motor point in low concentration, or injected in sufficient amount for inhibiting the “muscarinic effects” of acetylcholine on the autonomous nervous system, did not prevent the motor reactions of acetylcholine on the cerebral cortex.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate a comprehensive MRI protocol that investigates for cancer, vascular disease, and degenerative/inflammatory disease from the head to the pelvis in less than 40 minutes on a new generation 48-channel 3T system. MATERIALS AND METHODS: All MR studies were performed on a 48-channel 3T MR scanner. A 20-channel head/neck coil, two 18-channel body arrays, and a 32-channel spine array were employed. A total of 4 healthy individuals were studied. The designed protocol included a combination of single-shot T2-weighted sequences, T1-weighted 3D gradient-echo pre- and post-gadolinium. All images were retrospectively evaluated by two radiologists independently for overall image quality. RESULTS: The image quality for cancer was rated as excellent in the liver, pancreas, kidneys, lungs, pelvic organs, and brain, and rated as fair in the colon and breast. For vascular diseases ratings were excellent in the aorta, major branch vessel origins, inferior vena cava, portal and hepatic veins, rated as good in pulmonary arteries, and as poor in the coronary arteries. For degenerative/inflammatory diseases ratings were excellent in the brain, liver and pancreas. The inter-observer agreement was excellent. CONCLUSION: A comprehensive and time efficient screening for important categories of disease processes may be achieved with high quality imaging in a new generation 48-channel 3T system.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Scanning tunnelling microscopy (STM) was used to characterise the basal surface of fresh cleaved crystals of 2H-WS2. Although no impurity or stacking faults could be detected by X-ray diffraction, STM images obtained with negative bias voltage showed two kinds of defects. These defects were attributed to an iodine derivative used as transport agent. In a flat surface free of defects, an image with atomic resolution was achieved with sulphur distances and angles as expected for hexagonal symmetry of 2H-WS2.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Tungsten oxide thin films with three different compositions were deposited by reactive sputtering in an oxygen-argon plasma. In a system composed of a home made photochemical reactor coupled with an optic fiber spectrophotometer, the photochromic effect was studied in these oxide films as function of UV irradiation time, in ethanol, methanol and formaldehyde atmospheres. It was observed that the photochromic efficiency depends on the vapor chemical nature where the film is irradiated as well as the film composition. Kinetic analysis suggest that two kinds of optical absorption centers should respond by the photochromic effect in these films, one generated at film surface and other inside it, which one presenting a different time constant.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Passive films formed in bicarbonate solutions on carbon steel, chromium steel and high speed steel have been characterized by XPS. The passive films formed on chromium and high speed steels showed superior protective properties than those formed on carbon steel. It was confirmed by XPS that the steel composition influences the passive film composition. Chromium oxide and hydroxide, as well as molybdenum and tungsten oxides and hydroxides are present in the passive film of chromium steel and high speed steel, respectively, besides iron oxide and hydroxide. The more complex composition of the oxide film on high speed steel explains its electrochemical behaviour and highest corrosion resistance.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The sensitivity and accuracy of sequential injection methods are dependent on efficient overlapping of reagent and sample zones as they are propelled toward the detector cell. The formation of the reduced phosphomolybdic acid is used to demonstrate that the overlapping efficiency in a fixed reaction coil relies on a suitable choice of reagent to sample volume ratio. Additionally, under poor mixing conditions or highly concentrated samples, the reaction extension is strongly dependent on the reagent concentration. The zone-sampling concept is exploited to determine phosphate in cola-based soft drinks after in-line dilution in an auxiliary coil.