13 resultados para run-time allocation

em Scielo Saúde Pública - SP


Relevância:

80.00% 80.00%

Publicador:

Resumo:

The present work describes a novel stability-indicating reversed-phase ultra performance liquid chromatography method for the separation and quantification of rosuvastatin (RSV) and its related impurities in the pharmaceutical dosage forms under forced degradation conditions. An unknown degradation impurity detected in the acid degradation was identified by using quadrupole time-of-flight mass spectrometry. The chromatographic separation was carried out on C-18 column (100 x 2.1 mm, 1.7 μm) using isocratic elution with methanol and 0.1% trifluoroacetic acid (50:50). The total run time was 12 min within which RSV as well as all related impurities and degradation products were separated. The developed method was validated for RSV and related impurities in pharmaceutical dosage forms.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

An LC-MS/MS method has been developed for the determination of efavirenz (EFZ) in human plasma using hydrochlorothiazide as internal standard (I.S.). An ESI negative mode with multiple reaction-monitoring was used monitoring the transitions m/z 313.88→69.24 (EFZ) and 296.02→204.76 (I.S.). Samples were extracted using liquid-liquid extraction. The total run time was 2.0 min. The separation was achieved with HPLC-RP using a monolithic column. The assay was linear in the concentration range of 100 - 5000 ng mL-1. The mean recovery was 83%. Intra- and inter-day precision were < 9.5% and < 8.9%, respectively and accuracy was in the range ± 8.33%. The method was successfully applied to a bioequivalence study.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A simple and rapid ultra-performance liquid chromatographic method for determination of oseltamivir in capsules was developed and validated. The mobile phase consisted of 5 mmol/L triethylammonium buffer (pH 3.0) and acetonitrile (70:30, v/v). Separation was performed in a Hypersil Gold® column, with octylsilil as stationary phase (100 x 2.1 mm, p.d. 1.9 µm). Chromatography run time was 1.2 min. The method presented adequate specificity, linearity, precision, ruggedness and accuracy and was adequate for determination of oseltamivir in capsules.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A simple and fast method for determination of 40 basic drugs in human plasma employing gas-chromatography with nitrogen-phosphorus detection was developed and validated. Drugs were extracted from 800 µL of plasma with 250 µL of butyl acetate at basic pH. Aliquots of the organic extract were directly injected on a column with methylsilicone stationary phase. Total chromatographic run time was 25 min. All compounds were detected in concentrations ranging from therapeutic to toxic levels, with intermediate precision CV% below 11.2 and accuracy in the range of 92-114%.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Topiramate and the other frequently co-administered antiepileptic drugs carbamazepine, phenytoin and phenobarbital were determined in 100 µL plasma samples by gas chromatography with nitrogen phosphorus detection (GC-NPD), after a one-step liquid-liquid extraction with ethyl acetate, followed by flash methylation with trimethylphenylammonium hydroxide. Total chromatographic run time was 12.5 min. Intra-assay and inter-assay precision was 2.5-7.3% and 1.6-5.2%, respectively. Accuracy was 100.1-104.2%. The limit of quantitation was 1 µg mL-1 for all analytes, proving suitable for routine application in therapeutic drug monitoring of antiepileptic drugs.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Carbamazepine, phenobarbital and phenytoin were determined in dried blood spots (DBS) by high performance liquid chromatography, after extraction of 8 mm DBS using a mixture of acetonitrile and methanol. Analytes were separated by reversed-phase chromatography, with a run time of 17 minutes. Intra-assay and inter-assay precisions were in the 5.3 to 8.4% and 3.3 to 5.2% ranges, respectively. Accuracy was in the 98.8 to 104.3% range. The method had sensitivity to detect all analytes at levels below minimum therapeutic concentrations. The analytes were stable at 4 ºC and room temperature for up to 12 days and at 45 ºC for 9 days. The method was applied to 14 paired clinical samples of blood serum and DBS.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A fast gas chromatography with a flame ionisation detector (GC-FID) method for the simultaneous analysis of methyl palmitate (C16:0), stearate (C18:0), oleate (C18:1), linoleate (C18:2) and linolenate (C18:3) in biodiesel samples was proposed. The analysis was conducted in a customised ionic-liquid stationary-phase capillary, SLB-IL 111, with a length of 14 m, an internal diameter of 0.10 mm, a film thickness of 0.08 µm and operated isothermally at 160 °C using hydrogen as the carrier gas at a rate of 50 cm s-1 in run time about 3 min. Once methyl myristate (C14:0) is present lower than 0.5% m/m in real samples it was used as an internal standard. The method was successful applied to monitoring basic and acidic catalysis transesterification reactions of vegetable oils such as soybean, canola, corn, sunflower and those used in frying process.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The Caco-2 cell line has been used as a model to predict the in vitro permeability of the human intestinal barrier. The predictive potential of the assay relies on an appropriate in-house validation of the method. The objective of the present study was to develop a single HPLC-UV method for the identification and quantitation of marker drugs and to determine the suitability of the Caco-2 cell permeability assay. A simple chromatographic method was developed for the simultaneous determination of both passively (propranolol, carbamazepine, acyclovir, and hydrochlorothiazide) and actively transported drugs (vinblastine and verapamil). Separation was achieved on a C18 column with step-gradient elution (acetonitrile and aqueous solution of ammonium acetate, pH 3.0) at a flow rate of 1.0 mL/min and UV detection at 275 nm during the total run time of 35 min. The method was validated and found to be specific, linear, precise, and accurate. This chromatographic system can be readily used on a routine basis and its utilization can be extended to other permeability models. The results obtained in the Caco-2 bi-directional transport experiments confirmed the validity of the assay, given that high and low permeability profiles were identified, and P-glycoprotein functionality was established.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

When the offset of a visual stimulus (GAP condition) precedes the onset of a target, saccadic reaction times are reduced in relation to the condition with no offset (overlap condition) - the GAP effect. However, the existence of the GAP effect for manual responses is still controversial. In two experiments using both simple (Experiment 1, N = 18) and choice key-press procedures (Experiment 2, N = 12), we looked for the GAP effect in manual responses and investigated possible contextual influences on it. Participants were asked to respond to the imperative stimulus that would occur under different experimental contexts, created by varying the array of warning-stimulus intervals (0, 300 and 1000 ms) and conditions (GAP and overlap): i) intervals and conditions were randomized throughout the experiment; ii) conditions were run in different blocks and intervals were randomized; iii) intervals were run in different blocks and conditions were randomized. Our data showed that no GAP effect was obtained for any manipulation. The predictability of stimulus occurrence produced the strongest influence on response latencies. In Experiment 1, simple manual responses were shorter when the intervals were blocked (247 ms, P < 0.001) in relation to the other two contexts (274 and 279 ms). Despite the use of choice key-press procedures, Experiment 2 produced a similar pattern of results. A discussion addressing the critical conditions to obtain the GAP effect for distinct motor responses is presented. In short, our data stress the relevance of the temporal allocation of attention for behavioral performance.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Liver transplantation is now the standard treatment for end-stage liver disease. Given the shortage of liver donors and the progressively higher number of patients waiting for transplantation, improvements in patient selection and optimization of timing for transplantation are needed. Several solutions have been suggested, including increasing the donor pool; a fair policy for allocation, not permitting variables such as age, gender, and race, or third-party payer status to play any role; and knowledge of the natural history of each liver disease for which transplantation is offered. To observe ethical rules and distributive justice (guarantee to every citizen the same opportunity to get an organ), the "sickest first" policy must be used. Studies have demonstrated that death has no relationship with waiting time, but rather with the severity of liver disease at the time of inclusion. Thus, waiting time is no longer part of the United Network for Organ Sharing distribution criteria. Waiting time only differentiates between equally severely diseased patients. The authors have analyzed the waiting list mortality and 1-year survival for patients of the State of São Paulo, from July 1997 through January 2001. Only the chronological criterion was used. According to "Secretaria de Estado da Saúde de São Paulo" data, among all waiting list deaths, 82.2% occurred within the first year, and 37.6% within the first 3 months following inclusion. The allocation of livers based on waiting time is neither fair nor ethical, impairs distributive justice and human rights, and does not occur in any other part of the world.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper draws upon a detailed longitudinal survey of households living on agricultural plots in the northern three provinces of the Ecuadorian Amazon, the principal region of colonization by migrants in Ecuador since the 1970s. Following the discovery of petroleum in 1967 near what has subsequently come to be the provincial capital and largest Amazonian city of Lago Agrio, oil companies built roads to lay pipelines to extract and pump oil across the Andes for export. As a result, for the past 30 years over half of both Ecuador's export earnings and government revenues have come from petroleum extracted from this region. But the roads also facilitated massive spontaneous in-migration of families from origin areas in the Ecuadorian Sierra, characterized by minifundia and rural poverty. This paper is about those migrants and their effects on the Amazonian landscape. We discuss the data collection methodology and summarize key results on settler characteristics and changes in population, land use, land ownership, technology, labor allocation, and living conditions, as well as the relationships between changes in population and changes in land use over time. The population in the study region has been growing rapidly due to both natural population growth (high fertility) and in-migration. This has led to a dramatic process of subdivision and fragmentation of plots in the 1990's, which contrasts with the consolidation of plots that has occurred in most of the mature frontier areas of the Brazilian Amazon. This fragmentation has led to important changes in land tenure and land use, deforestation, cattle raising, labor allocation, and settler welfare.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The parameters of germination, initial growth, and biomass allocation of three native plant species of Cerrado (Copaifera langsdorffii, Dipteryx alata and Kielmeyera coriacea) were established. The species had germination percentages above 88% and average germination times longer than 139 hours. The average time for the opening of the first leaf pair was more than 538 hours for all three species. The average root length of C. langsdorffii and D. alata seedlings after 80 days of growth was around 40cm, four times larger than the average shoot length (<10cm), although the root and shoot biomasses were similar for both species. The average root length (>20cm) of K. coriacea seedlings was four times larger than the average shoot length (<5cm), and the root biomass was 243% greater than the shoot biomass. Increase in seedling biomass was sustained primarily by the cotyledons in C. langsdorffii and D. alata, which acted as reserve organs and showed progressive weight reductions. Increase in seedling biomass in K. coriacea was sustained primarily by photosynthesis, since the cotyledons showed no significant weight reduction, acting primarily as photosynthetic organs. The length of the root systems was at least four times larger than the length of the shoots parts in all three species. Higher investment in root length rather than in root biomass suggest that the initial growth of these species is primarily to ensure access to water resources, apparently putting off the function of the radicular system as storage organ.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The DNA extraction is a critical step in Genetically Modified Organisms analysis based on real-time PCR. In this study, the CTAB and DNeasy methods provided good quality and quantity of DNA from the texturized soy protein, infant formula, and soy milk samples. Concerning the Certified Reference Material consisting of 5% Roundup Ready® soybean, neither method yielded DNA of good quality. However, the dilution test applied in the CTAB extracts showed no interference of inhibitory substances. The PCR efficiencies of lectin target amplification were not statistically different, and the coefficients of correlation (R²) demonstrated high degree of correlation between the copy numbers and the threshold cycle (Ct) values. ANOVA showed suitable adjustment of the regression and absence of significant linear deviations. The efficiencies of the p35S amplification were not statistically different, and all R² values using DNeasy extracts were above 0.98 with no significant linear deviations. Two out of three R² values using CTAB extracts were lower than 0.98, corresponding to lower degree of correlation, and the lack-of-fit test showed significant linear deviation in one run. The comparative analysis of the Ct values for the p35S and lectin targets demonstrated no statistical significant differences between the analytical curves of each target.