10 resultados para High Power Laser Beam

em Scielo Saúde Pública - SP


Relevância:

100.00% 100.00%

Publicador:

Resumo:

A capillary electrophoresis system using laser induced fluorescence detection is described. A Raman system equipped with a microscope has been used to focus the laser beam on the capillary giving a lateral resolution of 1.5 mm. The fluorescence signal of the analyte (ZnPcTS - tetrasulfonated zinc-phthalocyanine) was collected by the microscope objectives and analysed by a monochromator with confocal characteristics equipped with a CCD detector. Electropherograms obtained with this system were compared to those obtained on a commercial instrument, showing that the described system presents a lower detection limit and better resolution.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Beowulf cluster is perhaps the cheapest way to construct a high performance computers. The strategy of reaching a high power computing isn't so difficult, but buying and configurating should be done carefully. Technical aspects of hardware components and message-passing libraries are considered, with some results given as examples.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This work describes the optimization of pretreatment steps for the destruction of organic matter in samples of waters and biological fluids, by using an UV irradiation system with a high power UV radiation source (400 W). The efficiency of the system constructed for the photo-decomposition of samples of model waters, natural waters and biological fluids was investigated by performing recovery experiments of the metallic species Zn(II), Cd(II), Pb(II), Cu(II), Al(III) and Fe(III). The use of UV irradiation allowed the liberation of metals bound to the organic matrix and the determination of the total content of elements in the samples.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Significant functions in the Proton Exchange Membrane Fuel Cells (PEMFCs) rely on Gas Diffusion Layers (GDLs), such as control the water balance in the membrane electrode assembly (MEA), allow suitable gas permeability and porosity, etc. Aware of the GDL importance in the cell performance and its great demand in scale-up projects, the fuel cell research group at Instituto de Pesquisas Energéticas e Nucleares (IPEN) has developed a Sieve Printing method (innovative in Brazil) as a strategic solution for producing GDL and electrodes used in high power PEMFC stacks. The method has shown to be adequate to fabricate low cost electrodes, GDLs of different dimensions and to produce any amount of MEAs for power stacks.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper provides an up-to-date critical review of methods for diamond synthesis by lasers. A provisional classification of synthesizing methods is carried out, in order to present a varied and heterogeneous experimental work that is as clear as possible. Laser diamond CVD methods involve chemical processes in a carbon-containing system induced by specific absorption of laser radiation, while diamond PVD methods involve physical processes induced by an intense, highly-directed laser beam. Different methods involving coupled, simultaneous action of lasers and classic CVD agents are suggested and discussed as prospective approaches for diamond synthesis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The authors present a case report of a victim of high power electric shock. The main electric lesion was a penetrating abdominal wound with loss of substance of the abdominal wall and an electric lesion of the hepatic segment and of the gallbladder. The surgical treatment included hepatic segmentectomy, cholecystectomy, repair of the abdominal wall with Marlex prosthesis and skin graft, besides the debridment of the lesions of extremities. The postoperative evolution was satisfactory and the follow-up for 6 months didn't show any sequelae.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate the applicability of the main categories of risk and morphological factors in the prognosis of gastrointestinal stromal tumors. METHODS: we retrospectively studied fifty-four cases of GIST, assessing the main prognostic factors of this neoplasis: risk levels, topography, size, mitotic index, necrosis, histological subtype and immunophenotype. We also verified their association and the reduction of overall survival. RESULTS: Univariate analysis showed that tumors with mitoses number greater than 5 per 50CGA (high-power fields), the presence of necrosis and a high risk for both the systems proposed by Fletcher and Miettinen had a significant association with reduced survival (p = 0.00001, 0.0056, 0.03 and 0.009, respectively). The remaining analyzed factors (size, histological subtype, topography and immunophenotype) had no such association. Multivariate analysis (Jacard index) showed that the Miettinen degree of risk was the one that best correlated with prognosis. CONCLUSION: the risk criteria of Fletcher and Miettinen are important in assessing the prognosis of patients with gastrointestinal stromal tumors, especially the latter, which adds to the mitotic index and the presence of tumor necrosis.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Recent technological developments have created new devices that could improve and simplify the construction of stimulus isolators. HEXFET transistors can switch large currents and hundreds of volts in nanoseconds. The newer opto-isolators can give a pulse rise time of a few nanoseconds, with output compatible with MOSFET devices, in which delays are reduced to nanoseconds. Integrated DC/DC converters are now available. Using these new resources we developed a new electrical stimulus isolator circuit with selectable constant-current and constant-voltage modes, which are precise and easy to construct. The circuit works like a regulated power supply in both modes with output switched to zero or to free mode through an opto-isolator device. The isolator analyses showed good practical performance. The output to ground resistance was 1011 ohms and capacitance 35 picofarads. The rise time and fall time were identical (5 µs) and constant. The selectable voltage or current output mode made it very convenient to use. The current mode, with higher output resistance values in low current ranges, permits intracellular stimulation even with tip resistances close to 100 megaohms. The high compliance of 200 V guarantees the value of the current stimulus. The very low output resistance in the voltage mode made the device highly suitable for extracellular stimulation with low impedance electrodes. Most importantly, these characteristics were achieved with a circuit that was easy to build and modify and assembled with components available in Brazil.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Increased heart rate variability (HRV) and high-frequency content of the terminal region of the ventricular activation of signal-averaged ECG (SAECG) have been reported in athletes. The present study investigates HRV and SAECG parameters as predictors of maximal aerobic power (VO2max) in athletes. HRV, SAECG and VO2max were determined in 18 high-performance long-distance (25 ± 6 years; 17 males) runners 24 h after a training session. Clinical visits, ECG and VO2max determination were scheduled for all athletes during thew training period. A group of 18 untrained healthy volunteers matched for age, gender, and body surface area was included as controls. SAECG was acquired in the resting supine position for 15 min and processed to extract average RR interval (Mean-RR) and root mean squared standard deviation (RMSSD) of the difference of two consecutive normal RR intervals. SAECG variables analyzed in the vector magnitude with 40-250 Hz band-pass bi-directional filtering were: total and 40-µV terminal (LAS40) duration of ventricular activation, RMS voltage of total (RMST) and of the 40-ms terminal region of ventricular activation. Linear and multivariate stepwise logistic regressions oriented by inter-group comparisons were adjusted in significant variables in order to predict VO2max, with a P < 0.05 considered to be significant. VO2max correlated significantly (P < 0.05) with RMST (r = 0.77), Mean-RR (r = 0.62), RMSSD (r = 0.47), and LAS40 (r = -0.39). RMST was the independent predictor of VO2max. In athletes, HRV and high-frequency components of the SAECG correlate with VO2max and the high-frequency content of SAECG is an independent predictor of VO2max.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Semiconductor laser devices are readily available and practical radiation sources providing wavelength tenability and high monochromaticity. Low-intensity red and near-infrared lasers are considered safe for use in clinical applications. However, adverse effects can occur via free radical generation, and the biological effects of these lasers from unusually high fluences or high doses have not yet been evaluated. Here, we evaluated the survival, filamentation induction and morphology of Escherichia coli cells deficient in repair of oxidative DNA lesions when exposed to low-intensity red and infrared lasers at unusually high fluences. Cultures of wild-type (AB1157), endonuclease III-deficient (JW1625-1), and endonuclease IV-deficient (JW2146-1) E. coli, in exponential and stationary growth phases, were exposed to red and infrared lasers (0, 250, 500, and 1000 J/cm2) to evaluate their survival rates, filamentation phenotype induction and cell morphologies. The results showed that low-intensity red and infrared lasers at high fluences are lethal, induce a filamentation phenotype, and alter the morphology of the E. coli cells. Low-intensity red and infrared lasers have potential to induce adverse effects on cells, whether used at unusually high fluences, or at high doses. Hence, there is a need to reinforce the importance of accurate dosimetry in therapeutic protocols.