Trauma abdominal penetrante consecutivo à corrente elétrica industrial


Autoria(s): Velho,Átila Varela; Strappazzon,José Luiz; Gabiatti,Gémerson
Data(s)

01/08/2000

Resumo

The authors present a case report of a victim of high power electric shock. The main electric lesion was a penetrating abdominal wound with loss of substance of the abdominal wall and an electric lesion of the hepatic segment and of the gallbladder. The surgical treatment included hepatic segmentectomy, cholecystectomy, repair of the abdominal wall with Marlex prosthesis and skin graft, besides the debridment of the lesions of extremities. The postoperative evolution was satisfactory and the follow-up for 6 months didn't show any sequelae.

Formato

text/html

Identificador

http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0100-69912000000400012

Idioma(s)

pt

Publicador

Colégio Brasileiro de Cirurgiões

Fonte

Revista do Colégio Brasileiro de Cirurgiões v.27 n.4 2000

Palavras-Chave #Penetrating abdominal trauma #Electric current #Electric burns
Tipo

journal article