11 resultados para HIGH-POWER
em Scielo Saúde Pública - SP
Resumo:
Beowulf cluster is perhaps the cheapest way to construct a high performance computers. The strategy of reaching a high power computing isn't so difficult, but buying and configurating should be done carefully. Technical aspects of hardware components and message-passing libraries are considered, with some results given as examples.
Resumo:
This work describes the optimization of pretreatment steps for the destruction of organic matter in samples of waters and biological fluids, by using an UV irradiation system with a high power UV radiation source (400 W). The efficiency of the system constructed for the photo-decomposition of samples of model waters, natural waters and biological fluids was investigated by performing recovery experiments of the metallic species Zn(II), Cd(II), Pb(II), Cu(II), Al(III) and Fe(III). The use of UV irradiation allowed the liberation of metals bound to the organic matrix and the determination of the total content of elements in the samples.
Resumo:
Significant functions in the Proton Exchange Membrane Fuel Cells (PEMFCs) rely on Gas Diffusion Layers (GDLs), such as control the water balance in the membrane electrode assembly (MEA), allow suitable gas permeability and porosity, etc. Aware of the GDL importance in the cell performance and its great demand in scale-up projects, the fuel cell research group at Instituto de Pesquisas Energéticas e Nucleares (IPEN) has developed a Sieve Printing method (innovative in Brazil) as a strategic solution for producing GDL and electrodes used in high power PEMFC stacks. The method has shown to be adequate to fabricate low cost electrodes, GDLs of different dimensions and to produce any amount of MEAs for power stacks.
Resumo:
The authors present a case report of a victim of high power electric shock. The main electric lesion was a penetrating abdominal wound with loss of substance of the abdominal wall and an electric lesion of the hepatic segment and of the gallbladder. The surgical treatment included hepatic segmentectomy, cholecystectomy, repair of the abdominal wall with Marlex prosthesis and skin graft, besides the debridment of the lesions of extremities. The postoperative evolution was satisfactory and the follow-up for 6 months didn't show any sequelae.
Resumo:
OBJECTIVE: To evaluate the applicability of the main categories of risk and morphological factors in the prognosis of gastrointestinal stromal tumors. METHODS: we retrospectively studied fifty-four cases of GIST, assessing the main prognostic factors of this neoplasis: risk levels, topography, size, mitotic index, necrosis, histological subtype and immunophenotype. We also verified their association and the reduction of overall survival. RESULTS: Univariate analysis showed that tumors with mitoses number greater than 5 per 50CGA (high-power fields), the presence of necrosis and a high risk for both the systems proposed by Fletcher and Miettinen had a significant association with reduced survival (p = 0.00001, 0.0056, 0.03 and 0.009, respectively). The remaining analyzed factors (size, histological subtype, topography and immunophenotype) had no such association. Multivariate analysis (Jacard index) showed that the Miettinen degree of risk was the one that best correlated with prognosis. CONCLUSION: the risk criteria of Fletcher and Miettinen are important in assessing the prognosis of patients with gastrointestinal stromal tumors, especially the latter, which adds to the mitotic index and the presence of tumor necrosis.
Resumo:
Recent technological developments have created new devices that could improve and simplify the construction of stimulus isolators. HEXFET transistors can switch large currents and hundreds of volts in nanoseconds. The newer opto-isolators can give a pulse rise time of a few nanoseconds, with output compatible with MOSFET devices, in which delays are reduced to nanoseconds. Integrated DC/DC converters are now available. Using these new resources we developed a new electrical stimulus isolator circuit with selectable constant-current and constant-voltage modes, which are precise and easy to construct. The circuit works like a regulated power supply in both modes with output switched to zero or to free mode through an opto-isolator device. The isolator analyses showed good practical performance. The output to ground resistance was 1011 ohms and capacitance 35 picofarads. The rise time and fall time were identical (5 µs) and constant. The selectable voltage or current output mode made it very convenient to use. The current mode, with higher output resistance values in low current ranges, permits intracellular stimulation even with tip resistances close to 100 megaohms. The high compliance of 200 V guarantees the value of the current stimulus. The very low output resistance in the voltage mode made the device highly suitable for extracellular stimulation with low impedance electrodes. Most importantly, these characteristics were achieved with a circuit that was easy to build and modify and assembled with components available in Brazil.
Resumo:
Increased heart rate variability (HRV) and high-frequency content of the terminal region of the ventricular activation of signal-averaged ECG (SAECG) have been reported in athletes. The present study investigates HRV and SAECG parameters as predictors of maximal aerobic power (VO2max) in athletes. HRV, SAECG and VO2max were determined in 18 high-performance long-distance (25 ± 6 years; 17 males) runners 24 h after a training session. Clinical visits, ECG and VO2max determination were scheduled for all athletes during thew training period. A group of 18 untrained healthy volunteers matched for age, gender, and body surface area was included as controls. SAECG was acquired in the resting supine position for 15 min and processed to extract average RR interval (Mean-RR) and root mean squared standard deviation (RMSSD) of the difference of two consecutive normal RR intervals. SAECG variables analyzed in the vector magnitude with 40-250 Hz band-pass bi-directional filtering were: total and 40-µV terminal (LAS40) duration of ventricular activation, RMS voltage of total (RMST) and of the 40-ms terminal region of ventricular activation. Linear and multivariate stepwise logistic regressions oriented by inter-group comparisons were adjusted in significant variables in order to predict VO2max, with a P < 0.05 considered to be significant. VO2max correlated significantly (P < 0.05) with RMST (r = 0.77), Mean-RR (r = 0.62), RMSSD (r = 0.47), and LAS40 (r = -0.39). RMST was the independent predictor of VO2max. In athletes, HRV and high-frequency components of the SAECG correlate with VO2max and the high-frequency content of SAECG is an independent predictor of VO2max.
Resumo:
The hemolytic power of rattlesnake venom (Crotalus durissus terrificus) was Studied. A high percentage of sample with negative hemolytic power was detected when sheep red blood cells were used. A large number of venoms with hemolytic power, though with a low hemolysis percentage, were detected when liquid, recently extracted venom was used. When crystallized venom was used under the same experimental conditions, a higher percentage ofpositivityfor hemolysis was obtained. When the results obtained on agar plates were compared to those obtained in test tubes, a large number of animals with a higher percentage of hemolysis were detected, though this value was not proportional to the number of animals showing positive plate hemolysis. When the hemolytic power of these venoms was tested on human red blood cells, a large percentage of animals with venoms having a low hemolytic power was also detected. Hemolytic power was much greater when human red blood cells were tested with crystallized venom. The preparation of red blood cells also had an important effect and the use of red blood cells from defibrinated blood is recommended. We conclude that rattlesnake venom has hemolytic power that increases when the venom is crystallized. Red blood cells should be properly preparedfor the lysis reactions. We suggest that the lytic power of the venom is related to venom concentration and to the purity of its fractions.
Resumo:
The rural electrification is characterized by geographical dispersion of the population, low consumption, high investment by consumers and high cost. Moreover, solar radiation constitutes an inexhaustible source of energy and in its conversion into electricity photovoltaic panels are used. In this study, equations were adjusted to field conditions presented by the manufacturer for current and power of small photovoltaic systems. The mathematical analysis was performed on the photovoltaic rural system I-100 from ISOFOTON, with power 300 Wp, located at the Experimental Farm Lageado of FCA/UNESP. For the development of such equations, the circuitry of photovoltaic cells has been studied to apply iterative numerical methods for the determination of electrical parameters and possible errors in the appropriate equations in the literature to reality. Therefore, a simulation of a photovoltaic panel was proposed through mathematical equations that were adjusted according to the data of local radiation. The results have presented equations that provide real answers to the user and may assist in the design of these systems, once calculated that the maximum power limit ensures a supply of energy generated. This real sizing helps establishing the possible applications of solar energy to the rural producer and informing the real possibilities of generating electricity from the sun.
Resumo:
Nineteen-channel EEGs were recorded from the scalp surface of 30 healthy subjects (16 males and 14 females, mean age: 34 years, SD: 11.7 years) at rest and under trains of intermittent photic stimulation (IPS) at rates of 5, 10 and 20 Hz. Digitalized data were submitted to spectral analysis with fast fourier transformation providing the basis for the computation of global field power (GFP). For quantification, GFP values in the frequency ranges of 5, 10 and 20 Hz at rest were divided by the corresponding data obtained under IPS. All subjects showed a photic driving effect at each rate of stimulation. GFP data were normally distributed, whereas ratios from photic driving effect data showed no uniform behavior due to high interindividual variability. Suppression of alpha-power after IPS with 10 Hz was observed in about 70% of the volunteers. In contrast, ratios of alpha-power were unequivocal in all subjects: IPS at 20 Hz always led to a suppression of alpha-power. Dividing alpha-GFP with 20-Hz IPS by alpha-GFP at rest (R = alpha-GFP IPS/alpha-GFPrest) thus resulted in ratios lower than 1. We conclude that ratios from GFP data with 20-Hz IPS may provide a suitable paradigm for further investigations.
Resumo:
This study assessed the antioxidant, total phenolic, and physicochemical properties of in vitro Terminalia Catappa Linn (locally called castanhola) using the DPPH assay. The castanhola fruits had an average weight of 19.60 ± 0.00 g, combining shell, pulp, and seed weight, and a soluble solids content of 8 °Brix. The chemical composition was determined with predominance of carbohydrates (76,88 ± 0,58%).The titration method was used to determine Vitamin C content using 2,6-dichlorophenolindophenol (DCFI), known as reactive Tillmans resulting in no significant levels. Aqueous extracts of castanhola pulp showed a higher concentration of phenolics, 244.33 ± 18.86 GAE.g-1 of fruit, and alcoholic extracts, 142.84 ± 2.09 GAE.g-1 of fruit. EC50 values of the aqueous extract showed a greater ability to scavenge free radicals than the alcoholic extracts. The fruit had a significant content of phenolic compounds and high antioxidant capacity.