92 resultados para Fast method
em Scielo Saúde Pública - SP
Resumo:
Abstract An accurate, reliable and fast multianalyte/multiclass ultra-performance liquid chromatography–tandem mass spectrometry (UPLC–MS/MS) method was developed and validated for the simultaneous analysis of 23 pharmaceuticals, belonging to different classes amphenicols, sulfonamides, tetracyclines, in honey samples. The method developed consists of ultrasonic extraction followed by UPLC–ESI–MS/MS with electrospray ionization in both positive mode and negative mode. The influence of the extraction solvents and mobile phase composition on the sensitivity of the method, and the optimum conditions for sample weight and extraction temperature in terms of analyte recovery were extensively studied. The identification of antibiotics is fulfilled by simultaneous use of chromatographic separation using an Acquity BEH C18 (100 mm x 2.1 mm, 1.7 µm) analytical column with a gradient elution of mobile phases and tandem mass spectrometry with an electrospray ionization. Finally, the method developed was applied to the determination of target analytes in honey samples obtained from the local markets and several beekeepers in Muğla, Turkey. Ultrasonic-extraction of pharmaceuticals from honey samples is a well-established technique by UPLC–ESI–MS/MS, the uniqueness of this study lies in the simultaneous determination of a remarkable number of compounds belonging to 23 drug at the sub-nanogram per kilogram level.
Resumo:
ELISA in situ can be used to titrate hepatitis A virus (HAV) particles and real-time polymerase chain reaction (RT-PCR) has been shown to be a fast method to quantify the HAV genome. Precise quantification of viral concentration is necessary to distinguish between infectious and non-infectious particles. The purpose of this study was to compare cell culture and RT-PCR quantification results and determine whether HAV genome quantification can be correlated with infectivity. For this purpose, three stocks of undiluted, five-fold diluted and 10-fold diluted HAV were prepared to inoculate cells in a 96-well plate. Monolayers were then incubated for seven, 10 and 14 days and the correlation between the ELISA in situ and RT-PCR results was evaluated. At 10 days post-incubation, the highest viral load was observed in all stocks of HAV via RT-PCR (10(5) copies/mL) (p = 0.0002), while ELISA revealed the highest quantity of particles after 14 days (optical density = 0.24, p < 0.001). At seven days post-infection, there was a significant statistical correlation between the results of the two methods, indicating equivalents titres of particles and HAV genome during this period of infection. The results reported here indicate that the duration of growth of HAV in cell culture must be taken into account to correlate genome quantification with infectivity.
Resumo:
In this work a fast method for the determination of the total sugar levels in samples of raw coffee was developed using the near infrared spectroscopy technique and multivariate regression. The sugar levels were initially obtained using gravimety as the reference method. Later on, the regression models were built from the near infrared spectra of the coffee samples. The original spectra were pre-treated according to the Kubelka-Munk transformation and multiplicative signal correction. The proposed analytical method made possible the direct determination of the total sugar levels in the samples with an error lower by 8% with respect to the conventional methodology.
Resumo:
A simple and fast method for determination of 40 basic drugs in human plasma employing gas-chromatography with nitrogen-phosphorus detection was developed and validated. Drugs were extracted from 800 µL of plasma with 250 µL of butyl acetate at basic pH. Aliquots of the organic extract were directly injected on a column with methylsilicone stationary phase. Total chromatographic run time was 25 min. All compounds were detected in concentrations ranging from therapeutic to toxic levels, with intermediate precision CV% below 11.2 and accuracy in the range of 92-114%.
Resumo:
A simple and fast method for the determination of nimesulide (NI) using flow injection analysis with multiple-pulse amperometric (FIA-MPA) detection at a boron-doped diamond (BDD) electrode was developed. The method was based mainly on the application of a four-potential waveform, E1(det) = -0.8 V / 30 ms, E2(det) = 0.6 V / 30 ms, E3(det) = -0.4 V / 30 ms and E4(cleaning) = -0.45 V / 300 ms versus Ag/AgCl (3.0 mol L-1 KCl). NI was detected at three different electrode potentials, at which the nitro group undergoes different redox reactions. The proposed method was selective and sensitive (detection limit of 81.0 nmol L-1), and successfully applied for the determination of NI in pharmaceutical formulations, yielding similar results to those obtained by the reference method.
Resumo:
In the present study, using noise-free simulated signals, we performed a comparative examination of several preprocessing techniques that are used to transform the cardiac event series in a regularly sampled time series, appropriate for spectral analysis of heart rhythm variability (HRV). First, a group of noise-free simulated point event series, which represents a time series of heartbeats, was generated by an integral pulse frequency modulation model. In order to evaluate the performance of the preprocessing methods, the differences between the spectra of the preprocessed simulated signals and the true spectrum (spectrum of the model input modulating signals) were surveyed by visual analysis and by contrasting merit indices. It is desired that estimated spectra match the true spectrum as close as possible, showing a minimum of harmonic components and other artifacts. The merit indices proposed to quantify these mismatches were the leakage rate, defined as a measure of leakage components (located outside some narrow windows centered at frequencies of model input modulating signals) with respect to the whole spectral components, and the numbers of leakage components with amplitudes greater than 1%, 5% and 10% of the total spectral components. Our data, obtained from a noise-free simulation, indicate that the utilization of heart rate values instead of heart period values in the derivation of signals representative of heart rhythm results in more accurate spectra. Furthermore, our data support the efficiency of the widely used preprocessing technique based on the convolution of inverse interval function values with a rectangular window, and suggest the preprocessing technique based on a cubic polynomial interpolation of inverse interval function values and succeeding spectral analysis as another efficient and fast method for the analysis of HRV signals
Resumo:
The assessment of fluid volume in neonates by a noninvasive, inexpensive, and fast method can contribute significantly to increase the quality of neonatal care. The objective of the present study was to calibrate an acquisition system and software to estimate the bioelectrical impedance parameters obtained by a method of bioelectrical impedance spectroscopy based on step response and to develop specific equations for the neonatal population to determine body fluid compartments. Bioelectric impedance measurements were performed by a laboratory homemade instrument. The volumes were estimated in a clinical study on 30 full-term neonates at four different times during the first month of life. During the first 24 hours of life the total body water, extracellular water and intracellular water were 2.09 ± 0.25, 1.20 ± 0.19, and 0.90 ± 0.25 liters, respectively. By the 48th hour they were 1.87 ± 0.27, 1.08 ± 0.17, and 0.79 ± 0.21 liters, respectively. On the 10th day they were 2.02 ± 0.25, 1.29 ± 0.21, and 0.72 ± 0.14 liters, respectively, and after 1 month they were 2.34 ± 0.27, 1.62 ± 0.20, and 0.72 ± 0.13 liters, respectively. The behavior of the estimated volume was correlated with neonatal body weight changes, leading to a better interpretation of such changes. In conclusion, this study indicates the feasibility of bioelectrical impedance spectroscopy as a method to help fluid administration in intensive care neonatal units, and also contribute to the development of new equations to estimate neonatal body fluid contents.
Resumo:
Chromium(III) at the ng L-1 level was extracted using partially silylated MCM-41 modified by a tetraazamacrocyclic compound (TAMC) and determined by inductively coupled plasma optical emision spectrometry (ICP OES). The extraction time and efficiency, pH and flow rate, type and minimum amount of stripping acid, and break- through volume were investigated. The method's enrichment factor and detection limit are 300 and 45.5 pg mL-1, respectively. The maximum capacity of the 10 mg of modified silylated MCM-41 was found to be 400.5±4.7 µg for Cr(III). The method was applied to the determination of Cr(III) and Cr(VI) in the wastewater of the chromium electroplating industry and in environmental and biological samples (black tea, hot and black pepper).
Resumo:
A fast gas chromatography with a flame ionisation detector (GC-FID) method for the simultaneous analysis of methyl palmitate (C16:0), stearate (C18:0), oleate (C18:1), linoleate (C18:2) and linolenate (C18:3) in biodiesel samples was proposed. The analysis was conducted in a customised ionic-liquid stationary-phase capillary, SLB-IL 111, with a length of 14 m, an internal diameter of 0.10 mm, a film thickness of 0.08 µm and operated isothermally at 160 °C using hydrogen as the carrier gas at a rate of 50 cm s-1 in run time about 3 min. Once methyl myristate (C14:0) is present lower than 0.5% m/m in real samples it was used as an internal standard. The method was successful applied to monitoring basic and acidic catalysis transesterification reactions of vegetable oils such as soybean, canola, corn, sunflower and those used in frying process.
Resumo:
The goal of this work was to develop a simple and rapid preparation method for patulin analysis in apple juice without previous clean-up. This method combined sonication and liquid extraction techniques and was used for determination of patulin in 37 commercial apple juices available on the market in the South of Brazil. The method performance characteristics were determined using a sample obtained in a local market fortified at five concentration levels of patulin and done in triplicates. The coefficient of variation for repeatability at the fortification level of 20.70µg.L-1 was 3.53 % and the recovery 94.63 %, respectively. The correlation coefficient was 0.9996 and agrees with the requirements for a linear analytical method value. The detection limit was 0.21µg.L-1 and the quantification limit 0.70 µg.L-1. Only three of the analyzed samples were upper the allowed level of 50.00 µg.L-1 recommended for the World Health Organization.
Resumo:
Tea has been considered a medicine and a healthy beverage since ancient times, but recently it has received a great deal of attention because of its antioxidant properties. Green tea polyphenols have demonstrated to be an effective chemopreventive agent. Recently, investigators have found that EGCG, one of the green tea catechins, could have anti-HIV effects when bound to CD4 receptor. Many factors can constitute important influences on the composition of tea, such as species, season, age of the leaf, climate, and horticultural practices (soil, water, minerals, fertilizers). This paper presents an HPLC analytical methodology development, using column RP-18 and mobile phase composed by water, acetonitrile, methanol, ethyl acetate, glacial acetic acid (89:6:1:3:1 v/v/v/v/v) for simultaneous determination and quantification of caffeine (CAF), catechin (C), epicatechin (EC) and epigallocatechin gallate (EGCG) in samples of Camellia sinensis (green tea) grown in Brazil and harvested in spring, in summer and in autumn, in comparison to Brazilian black tea, to samples of Japanese and Chinese green tea and to two standardized dry extracts of green tea. The method has been statistically evaluated and has proved to be adequate to qualitative and quantitative determination of the samples.
Resumo:
Energy drinks are becoming popular in Brazil and in the world due to their stimulant properties. Caffeine is present in energy drinks with the aim of stimulating the central nervous system and intensifying brain activity. On the other hand, the ingestion of high doses of caffeine can cause undesirable symptoms such as anxiety and tachycardia. Therefore, it is necessary to monitor the caffeine content added to energy drinks to guarantee that the levels in the final product are in accordance with the labeling and within the legislation limits. The goal of this work was to validate a fast, efficient, and low-cost method for the determination of caffeine in energy drinks by micellar electrokinetic chromatography (MEKC). A total of seven brands were analyzed, each in three lots. The electrolyte was prepared with 50 mmol.L-1 of sodium dodecyl sulfate (SDS) and 10 mmol.L-1 of sodium carbonate (pH 11.0). The mean concentration of caffeine ranged from 122.8 to 318.6 mg.L-1. None of the brands had caffeine levels above the maximum limit. Considering the interval of confidence (95%), 72% of the samples had less caffeine than the amount informed on the product label.
Resumo:
We elaborated an alternative culture method, which we denominated PKO (initials in tribute of respect to Petroff, Kudoh and Ogawa), for isolating Mycobacterium tuberculosis from sputum for diagnosis of pulmonary tuberculosis (TB), and to compare its performance with the Swab and Petroff methods. For the technique validation, sputum samples from patients suspected of pulmonary TB cases were examined by acid-fast microscopy (direct and concentrated smear), PKO, Swab and Petroff methods. We found that Petroff and PKO methods have parity in the effectiveness of M. tuberculosis isolation. However, by the PKO method, 65% of isolated strains were detected in a period of £15 days, while by the Petroff method the best detection was in an interval of 16-29 days (71%). In positive smear samples, the average time of PKO isolation is only superior to the one related for Bactec 460TB. In conclusion, the exclusion of the neutralization stage of pH in the PKO reduces the manipulation of the samples, diminishes the execution time of the culture according to the Petroff method and facilitates the qualification of professionals involved in the laboratorial diagnosis of Tuberculosis.
Resumo:
Mycolic acids analysis by thin-layer chromatography (TLC) has been employed by several laboratories worldwide as a method for fast identification of mycobacteria. This method was introduced in Brazil by our laboratory in 1992 as a routine identification technique. Up to the present, 861 strains isolated were identified by mycolic acids TLC and by standard biochemical tests; 61% out of these strains came as clinical samples, 4% isolated from frogs and 35% as environmental samples. Mycobacterium tuberculosis strains identified by classical methods were confirmed by their mycolic acids contents (I, III and IV). The method allowed earlier differentiation of M. avium complex - MAC (mycolic acids I, IV and VI) from M. simiae (acids I, II and IV), both with similar biochemical properties. The method also permitted to distinguish M. fortuitum (acids I and V) from M. chelonae (acids I and II) , and to detect mixed mycobacterial infections cases as M. tuberculosis with MAC and M. fortuitum with MAC. Concluding, four years experience shows that mycolic acids TLC is an easy, reliable, fast and inexpensive method, an important tool to put together conventional mycobacteria identification methods.
Resumo:
The presence of acid fast bacilli in multiple specimens was investigated comparatively with Ziehl-Neelsen (ZN) and fluorescence microscopy (FM) staining in order to determine sensitivity in detecting tuberculosis (TB). A total of 465 specimens obtained from 295 patients were analysed at Harran University Medical School Hospital between March 1998 and March 2000. The culture was employed as the reference method. Sixty-eight patients (23.1%) were diagnosed as having TB by culture. The ZN and FM staining sensitivities were 67.6% (46/68) and 85.2% (58/68) respectively. Two hundred and one patients (68.1%) submitted one specimen to the laboratory. TB positivity was detected in 42 (20.9%) of these patients by culture. The sensitivities of ZN and FM stains were found to be 61% and 83% in these patients. However, in 18 patients (6.1%) who submitted two specimens to the laboratory, the TB was positive in six of them (33.3%) and ZN and FM sensitivities were 66% and 83% respectively. When three specimens or more were collected from the patients (76 patients, 25.8%), TB positivity was determined in 20 of them (26.3%) and the sensitivities were 80% and 92% in the ZN- and FM-stained smears, respectively. Our data indicate that in the diagnosis of TB, FM has greater sensitivity than ZN. In particular, in the case of a single specimen, the diagnostic value of FM is quite significant. It is, therefore, possible to conclude that both ZN and FM staining can be used for the diagnosis of TB when there are more than two specimens. However, if only one or two specimens are available, FM staining is preferable.