140 resultados para Custo de captação
Resumo:
Silica gel is widely used as adsorbent for isolating and purifying natural compounds. Intensive use and high cost make this process expensive and generate solid residues contaminated with many different organic compounds. In the present work a simple method for recycling silica was investigated, by using Advanced Oxidative Processes. Silica gel was treated with H2O2/solar light and compared with a sample treated by conventional methods (high temperature and oxidation with KMnO4). High temperature treatment changes the structure of the silica and, consequently, the separation efficiency. Oxidation by using KMnO4 requires multiple steps and produces residues, including manganese and oxalic acid. The method using H2O2/solar light to recuperate silica gel does not modify its separation efficiency and is less expensive than the traditional methods. Additionally, HPLC and GC-MS analysis indicate that H2O2/solar light eliminates all residues of the silica gel.
Resumo:
A digital multimeter (~U$ 240.00 on the national market) connected to a microcomputer by a RS-232 serial interface is proposed for data acquisition in equipment with analog output. Data are measured at the rate of 2 points per second and stored in text files by the software that accompanies the device, running in a Windows environment. The performance of the multimeter was verified by monitoring the transient signals generated in flow injection systems associated with fluorimetric, spectrophotometric and flame photometric detection. In addition, the performance of the proposed device was similar to that attained by employing an interface card with a 12-bit analog-to-digital converter for acquisition of the signals generated by a capillary electrophoresis equipment with oscillometric detection.
Resumo:
Thin layer chromatography is a quick, inexpensive and effective way of screening mixtures of non-volatile organic compounds and it is highly recommended for analytical studies. Inspection of plates under ultraviolet light for the detection of colourless compounds should be performed before any further chemical methods are applied. Construction of a low-cost UV-viewing cabinet with lamp employing parts easily found on the local market is described.
Resumo:
A microcontrolled, portable and inexpensive photometer is described. It uses six light-emitting diodes (LEDs) as radiation sources and a phototransistor as detector, as well as a microcontroller (PIC - Programmable Controller of Interruption). This device provided total autonomy to the proposed photometer, which was successfully applied to determination of Fe2+ in ferrous syrups and of seven clinical biochemical parameters. As the components are cheap (~U$30.00) and easy to find, the proposed photometer is an economical alternative for routine chemical analyses in small laboratories, for research and teaching. Being portable and microcontrolled, it allows doing field chemical analyses.
Resumo:
A new passive sampling system for monitoring NO2 in air has been developed to measure gas concentrations in indoor and outdoor air. The sampler is inexpensive, and easy to construct and operate. Nitrogen dioxide forms a derivative after reaction with a filter coated with triethanolamine and ethyleneglycol. The nitrogen dioxide derivative is extracted from the filter, and the concentration is determined by colorimetry. To test the sampler for measuring ambient level nitrogen dioxide, measurements were carried out inside homes and in a range of workplace environments.
Resumo:
The modern stopped-flow reaction analyzer has shown high efficiency and flexibility, which provides outstanding sample economy with a dead-time of less than 1 ms. However the cost of the equipment imposes a serious restriction to many Brazilian scientists and teachers. In this work we describe the construction of a low-cost stopped-flow system coupled to a UV-Vis spectrophotometer. The performance of the system was checked by monitoring the kinetics of two reactions: the fading of phenolphthalein in aqueous alkaline solution and the chlorophyll a demetallation in acid medium. The apparatus showed reasonable efficiency with a dead-time of 0.3 to 0.5 s. The very good results obtained in these two illustrative processes show that the system is satisfactory for determining rate constants with mean reaction times ranging from seconds to minutes.
Resumo:
Chromatography is a means of separating mixtures into their several components. TLC, mainly a liquid/solid process, is one of the separation techniques most often used. It is indispensable in laboratories dealing with natural products, organic and analytical chemistry. Commercial chromatography plates are offered at relatively high cost. In this work the construction of a hand-operated plate coater of stationary phases of low cost and good reproducibility is described to be used in teaching laboratories and research.
Resumo:
This paper describes a homemade autosampler for flow injection analysis (FIA), constructed with two step motors from old floppy disk drives (5¼-inch). The autosampler was connected to a computer through the parallel port and the sampling process was controlled by software in Quick Basic. The performance of the system was assessed by the determination of ammonium, based on the gaseous diffusion into a bromocresol purple solution, following the spectrophotometric determination of change in absorbance. The easy and simple construction is the main characteristics of this equipment and analytical results with RSD lower than 1% were obtained.
Resumo:
The high cost of sensitivity commercial calorimeters may represent an obstacle for many calorimetric research groups. This work describes the construction and calibration of a batch differential heat conduction calorimeter with sample cells volumes of about 400 μL. The calorimeter was built using two small high sensibility square Peltier thermoelectric sensors and the total cost was estimated to be about US$ 500. The calorimeter was used to study the excess enthalpy of solution of binary mixtures of liquids, as a function of composition, for the following binary systems of solvents: water + 1,4-dioxane or + dimethylsulfoxide at 298,2 ± 0,5 K.
Resumo:
Regulatory pressure is increasingly focusing on the use and disposal of substances hazardous to human health and environment. In the last years efforts have also been made to introduce green chemistry concepts in undergraduate courses. In this paper we present an experiment on the oxidation reaction of borneol to camphor with bleach in acetone. This experiment is important to show undergraduate students that a cheap and non hazardous commercial product can be a useful oxidation agent of alcohols.
Resumo:
Conventional sample holder cells used to the electric characterization of ceramics at high temperature consists of an alumina tube and platinum wires and plates using a complex design. The high cost materials used in the conventional sampler holder cell were replaced by stainless steel and conventional ceramics. The sample holder was validated by characterizing yttria-stabilized-zirconia in a temperature range of 25 to 700 ºC. The results do not present variations, discontinuity or unusual noise in the electric signals. Several samples were characterized without maintenance, which demonstrates that the sample holder is electric and mechanic adequate to be used to electrical characterization of ceramics up to 700 ºC.
Resumo:
The present manuscript shows the synthesis of nickel hydroxide supported in carbon (Ni(OH)2/C) as a alternative material for catalytic alcohol oxidation in alkaline medium. The Ni(OH)2/C was synthesized in different percentage using a sonic bath. No current densities variation during successive cyclic voltammetry experiments was observed. The Ni(OH)2/C electrodes exhibit a potent and persistent electrocatalytic activity towards the oxidation of different alcohols. In addition, alcohols electooxidation occurs in less positive potential compared with noble metal catalyst.
Resumo:
Infrared spectroscopy is a versatile technique used for qualitative and quantitative determination of all types of molecular species. As far as analysis of confined or flowing gases is concerned, different types of cell can be found in the market, but they are often very expensive. This study describes the construction of a very efficient gas cell with good reproducibility for qualitative infrared analysis of confined or flowing gases, using easily available and low-cost materials.
Resumo:
The construction of a low cost mini sensor containing a bismuth-film electrode (BiFE), as work electrode, a silver electrode as pseudo reference electrode, and copper as counter electrode is proposed. The application of this mini sensor using a low cost electrochemical cell for in loco voltammetric determinations of inorganic and organic analytes is also described.
Resumo:
Extraction/concentration is a crucial step for the analysis of organic compounds at trace level concentrations and dispersed in complex matrices. Solid-phase extraction (SPE) is one of the techniques used for this purpose. In this work, a low cost apparatus for SPE was developed that uses nitrogen under positive pressure and ensures the maintenance of the sample flow, while also allows the simultaneous extraction of different samples without cross-contamination and sample contact with plastic materials. For the system set up, easily accessible materials were used such as hypodermic needles, stainless steel tubes, rubber stoppers, and 3-way valves from serum delivery apparatus.