127 resultados para Slope streaks


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The construction of a tubular hydrogen ion-selective potentiometric electrode without inner reference solution, based on the tridodecylamine (TDDA) ionophore, and its evaluation in a flow system are described. TDDA was dissolved in 2-nitrophenyl octyl ether, dispersed in a PVC membrane and applied directly to a conducting support which consisted of an epoxy resin and graphite mixture. The electrode was designed with a tubular geometry to effort facilities to be coupled as part of a flow injection network. The main working characteristics such as response time, linear pH range, selectivity and life time were evaluated and compared with those obtained which a conventionally shaped electrode based on the same sensor. The electrode showed a slope of 51-52 mV dec-1 within a linear pH range from 4.0 up to 12.0.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper proposes an experiment to be performed in both instrumental analysis and experimental physical-chemistry curricular disciplines in order to open options to develop challenging basic research activities. Thus the experimental procedures and the results obtained in the preparation of electrodeposited lead dioxide onto graphite and its evaluation as potentiometric sensor for H3O+ and Pb2+ ions, are presented. The data obtained in acid-base titrations were compared with those of the traditional combination glass electrode at the same conditions. Although a linear sub-Nernstian response to free hydrogen ions was observed for the electrodeposited PbO2 electrode, a good agreement was obtained between them. Working as lead(II) sensing electrode, the PbO2 showed a linear sub-Nernstian behavior at total Pb2+ concentrations ranging from 3,5 x 10-4 to 3,0 x 10-2 mol/L in nitrate media. For the redox couple PbO2/Pb(II) the operational slope converges to the theoretical one, as the acidity of the working solution increases.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A flow injection (FI) spectrophotometric procedure is proposed for the determination of vitamin B6 (pyridoxine hydrochloride) in pharmaceutical preparations. Powdered samples containing from 2.5 to 4.5 mg, were previously dissolved in 0.1 mol L-1 phosphate buffer solution (pH 7.0) and a volume of 500 muL was injected directly into a carrier stream consisting of this same phosphate buffer solution, flowing at 4.4 mL min-1. The stable blue indophenol dye produced in the oxidation of pyridoxine hydrochloride by potassium hexacyanoferrate(III) and N,N-diethyl-p-phenylenediamine solution was directly measured at 684 nm. Vitamin B6 was determined in five pharmaceutical preparations in the 0.5 to 6.0 mg L-1 concentration range (calibration graph: A= -0.00499 + 0.11963 C; r= 0.9991, where A is the absorbance and C is the vitamin B6 concentration in mg L-1), with a detection limit of 0.02 mg L-1 (3 Sblank/slope). The recovery of this vitamin from three samples ranged from 97.5 to 103.3 %. The analytical frequency was 62 h-1 and r.s.d. were less than 2% for solutions containing 1.0 and 3.0 mg L-1 vitamin B6 (n= 10). The results obtained for the determination of vitamin B6 in commercial formulations were in good agreement with those obtained by a spectrophotometric procedure (r=0.9997) and also with the label values (r= 0.9998).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A flow injection spectrophotometric procedure was developed for the determination of metamizol in pharmaceutical formulations. The system is based on the reaction between metamizol and triiodide generated in the system by mixing iodate and iodide-starch solutions. The absorbance of triiodide-starch complex giving a steady-state baseline value which was monitored at 580 nm. The inverse peaks caused by metamizol samples were measured and there was a direct relationship between absorbance decreasing and metamizol concentration from 1.4 x 10-4 to 7.0 x 10-4 mol L-1. The RSD was 0.45 % for a metamizol solution 4.2 x 10-4 mol L-1 (n = 10) with a detection limit (three-fold blank standard deviation/slope) of 6.0 x 10-5 mol L-1 The feasibility of the system was demonstrated for the determination of metamizol in commercial samples with sixty results obtained per hour. The results obtained for metamizol in pharmaceutical formulations using the proposed flow procedure and those obtained using an iodimetric procedure are in agreement at the 95% confidence level and within an acceptable range of error.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The determination of fractal dimension (D) of humic particles was achieved by the turbidimetric technique where diluted suspensions of humic acids, in different experimental conditions, were analyzed by spectrophotometry UV-Vis. The slope of the lines (beta) was taken from the graphics (logtauvs loglambda) to obtain D. The results show that the values of D changed according to pH (3.0, 5.0 and 7.0), temperature (25 and 5 ºC) and shaking (magnetic and horizontal). In general, the value of D decreased with the increment of pH, increase of shaking and decrease of temperature.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The construction and analytical evaluation of a coated graphite Al(III) ion-selective electrode, based on the ionic pair formed between the Al(F)n3-n anion and tricaprylylmethylammonium cation (Aliquat 336S) incorporated on a poly(vinylchloride) (PVC) matrix membrane are described. A thin membrane film of this ionic pair and dibutylphthalate (DBPh) in PVC was deposited directly on a cylindric graphite rod (2 cm length x 0.5 cm diameter) attached to the end of a glass tube using epoxy resin. The membrane solution was prepared by dissolving 40% (m/m) of PVC in 10 mL of tetrahydrofuran following addition of 45% (m/m) of DBPh and 15% (m/m) of the ionic pair. The effect of membrane composition, fluoride concentration, and several concomitants as potential interferences on the electrode response were investigated. The aluminium(III) ion-selective electrode showed a linear response ranging from 1.4 x 10-4 to 1.0 x 10-2 mol L-1, a detection limit of 4.0 x 10-5 mol L-1, aslope of -54.3±0.2mV dec-1 and a lifetime of more than 1 year (over 3000 determinations for each membrane). The slope indicates that the ion-selective electrode responds preferentially to the Al(F)4- species. Application of this electrode for the aluminium(III) determination in stomach anti-acid samples is reported.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A simple flow injection procedure was developed for determining dipyrone (1-phenyl-2,3-dimethyl-4-methylaminomethano-5-pyrazolone sodium, metamizol, analgin) in pharmaceutical formulations. The determination is based on the reduction of Ag+ ions to Ag0 by dipyrone. A colloidal suspension of Ag0 produced was transported by carrier solution (0.01 mol L-1 NaOH) and turbidimetrically detected at 425 nm. The analytical curve for dipyrone was linear in the range from 5.0 x 10-4 to 2.5 x 10-3 mol L-1 with a correlation coefficient of 0.9990. The detection limit was 1.3 x 10-4 mol L-1 (3sigmaB/slope). The relative standard deviation for ten successive measurements was 1.8% and an analytical frequency of 45 h-1 was obtained. The recovery values from three samples ranged from 96.0 to 102%.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Sulfur emission in coal power generation is a matter of great environmental concern and limestone sorbents are widely used for reducing such emissions. Thermogravimetry was applied to determine the effects of the type of limestone (calcite and dolomite), particle size (530 and 650 µm) and atmosphere (air and nitrogen) on the kinetics of SO2 sorption by limestone. Isothermal experiments were performed for different temperatures (650 to 950 ºC), at local atmospheric pressure. The apparent activation energies, as indicated by the slope of the Arrhenius plot, resulted between 3.03 and 4.45 kJ mol-1 for the calcite, and 11.24 kJ mol-1 for the dolomite.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The present work analyzed the effect of the temperature and type of salt on the phase equilibrium of aqueous two-phase systems (ATPS) formed by poly (ethylene glycol) (PEG) 1500 + potassium phosphate, from (278.15 to 318.15) K, and PEG 1500 + sodium citrate, from (278.15 to 298.15) K. The rise of the temperature normally increased the slope of the tie line (STL). With respect to the influence of the type of salt, sodium citrate showed better capability to induce phase separation, when compared to potassium phosphate.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this paper, we analyze the use of electrical impedance spectroscopy applied to determination of cloud point. The slope of admittance measured at 100 kHz is reduced to temperature above the critical value which characterizes the phase transition, in a strong indication that this process is activated during the clouding. Additionally to this study we explored the influence of parameters such as additives and temperature on the performance of phase separation of residues (silver nanoparticles) by cloud point extraction. The interaction with salt maximizes the separation of chemical residues in a progressively reduced temperature.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Surface and electrochemical properties of the dimensionally stable anode Ti/(Ru0.3Ti0.7)O2 were studied as a function of the annealing temperature using different conditions in order to perform the cooling process of the oxide films (conventional thermal shock and the slow cooling processes). It was found that surface and electrochemical properties for the oxygen evolution reaction are both affected through the cooling process, being the electrode prepared at 400 ºC using the slow cooling process the less susceptible to wear. The Tafel slope obtained in the high overpotential domain was analysed in light of the apparent charge transfer coefficient.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A flow injection on-line pre-concentration system coupled to thermospray flame furnace atomic absorption spectrometry (TS-FF-AAS) for cadmium determination at sub μg L-1 levels in seawater samples was developed. The on-line system was evaluated by analysing cadmium containing in a synthetic seawater matrix (2.5% m/v NaCl, 0.5% m/v MgCl2 and 0.8% m/v CaCl2). A sample volume of 2 mL allows determining Cd with a detection limits of 30 ng L-1 (3* σblank/slope), pre-concentration factor of 34 and repeatability of 1,8% (calculated as RSD, N=8 and containing 200 ng L-1 of Cd ).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper describes the development of methods for the determination of Pb and Mn in fishes by GF AAS after solubilization with tetramethylamonium hidroxide. The optimization of the operational conditions and the choice of modifier were made using multivariated optimization. Analytical Figures of Merit were adequately to propose. The Limit of Quantification obtained were 150 and 18.5 µg kg-1 to Mn and Pb, respectively. No significant difference was found between the slope values obtained for the aqueous and standard addition calibration curves. The D.P.R. was always lower than 12% and the analysis of the SRM NRCC TORT2 showed 80-120% of recovery.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Components in complex matrices can cause variations in chromatographic response during analysis of pesticides by gas chromatography. These variations are related to the competition between analytes and matrix components for adsorption sites in the chromatographic system. The capacity of the pesticides chlorpyrifos and deltamethrin to be adsorbed in the injector and chromatographic column was evaluated by constructing three isotherms and changing the column heating rate to 10 and 30 ºC min-1. By using ANCOVA to compare the slope of calibration graphs, results showed that the higher the injector temperature (310 ºC) the lower the pesticide adsorption. Also, deltamethrin influenced the adsorption of chlorpyrifos on the column chromatographic.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Density of dilute aqueous solutions of 1,2 pentanediol, 2,4 pentanediol, 1,4 pentanediol and 1,5 pentanediol at 283.15, 288.15, 293.15, 298.15, 303.15 and 308.15 K in the concentration range 0.0000 to 0.0060 in mole fraction were determined by using Wood-Brusie type capillary neck pycnometers. The solute partial molar volume as a function of solute concentration for each system was correlated with a linear equation for each temperature to estimate the slope limit and the partial molar volume at infinite dilution, and the predominant hydrophilic-hydrophobic effect was found in this region.