100 resultados para Flow injection analysis with electrochemical detection
Resumo:
Different methods have been applied to solve special problems of metal analysis. First, the solid samples of tool steels were analyzed by X-ray fluorescence. Alternatively, an on-line electrodissolution implemented in a flow injection system and conventional dissolution procedure for determination of W, Mo, V and Cr in tool steels by ICP-AES is described. The resulting analyte solutions were compared with conventional dissolution procedure and determination by ICP-AES. The electrolytic procedure presented a good performance characterized by a sample throughput of 164 determinations per hour. Results were in agreement with those obtained by conventional acid dissolution.
Resumo:
A flow injection spectrophotometric procedure exploiting merging zones is proposed for determining vitamin B2 (riboflavin) in pharmaceutical preparations. The determination is based on the red-colored complex formation between vitamin B2 and silver(I) which was measured at 520 nm. Vitamin B2 was determined in four pharmaceutical preparations in the 1.0 to 50.0 mg L-1 concentration range, with a detection limit of 0.5 mg L-1. The recovery from three samples ranged from 98.0 to 104.0 %. The analytical frequency was 42 h-1 and r.s.d. were lower than 1% for solutions containing 10.0, 30.0 and 50.0 mg L-1 vitamin B2 (n= 10). The results obtained in commercial formulations using the FIA procedure were in good agreement with those obtained by using a conventional fluorimetric procedure (r=0.9998) and also with the label values (r= 0.9997).
Resumo:
This paper describes a sequential injection analysis (SIA) set-up coupled to a flame atomic absorption spectrometer (FAAS) to accomplish the determination of low concentrations of copper in drinking waters. Copper is first retained under neutral media in an on-line 29x1.6 mm column filled with poly(ethylenimine) immobilised on silica gel. The retained analyte is then eluted by flowing through the column 250 mL of a nitric acid solution. The selection of 3.85 ml of sample enabled to obtain a detection limit of 0.27 mug/L and a sampling rate of about 24 samples/h. There was a good agrement between the results of 12 samples furnished by the proposed procedure and by electrothermal atomic absorption spectrometry. Repeatability assessment gave a relative standard deviation of 1.3 % after ten replicate analysis of a sample containing about 70 mug/L in copper..
Resumo:
A flow injection spectrophotometric procedure is proposed for the determination of paracetamol (acetaminophen) in pharmaceutical formulations. Powdered and liquid samples were previously dissolved/diluted in 0.05 mol L-1 hydrochloric acid solution and a volume of 250 µL was injected directly into a carrier stream of this same acid solution, flowing at 2.5 mL min-1. Paracetamol reacts with sodium hypochlorite forming N-acetyl-p-benzoquinoneimine which then reacts with sodium salicylate in sodium hydroxide solution yielding a blue indophenol dye which was measured at 640 nm in the pH range of 9.5-10.0. Paracetamol was determined in pharmaceutical products in the 1.0 to 100.0 mg L-1 (3.3x10-6 a 6.6x10-4 mol L-1) concentration range, with a detection limit of 0.5 mg L-1 (1.6x10-6 mol L-1). The recovery of this analyte in five samples ranged from 98.0 to 103.6 %. The analytical frequency was 80 determinations per hour and the RSDs were less than 1% for paracetamol concentrations of 25.0, 50.0 and 75.0 mg L-1 (n=10). A paired t-test showed that all results obtained for paracetamol in commercial formulations using the proposed flow injection procedure and a spectrophotometric batch procedure agree at the 95% confidence level.
Resumo:
A flow injection spectrophotometric procedure was developed for the determination of metamizol in pharmaceutical formulations. The system is based on the reaction between metamizol and triiodide generated in the system by mixing iodate and iodide-starch solutions. The absorbance of triiodide-starch complex giving a steady-state baseline value which was monitored at 580 nm. The inverse peaks caused by metamizol samples were measured and there was a direct relationship between absorbance decreasing and metamizol concentration from 1.4 x 10-4 to 7.0 x 10-4 mol L-1. The RSD was 0.45 % for a metamizol solution 4.2 x 10-4 mol L-1 (n = 10) with a detection limit (three-fold blank standard deviation/slope) of 6.0 x 10-5 mol L-1 The feasibility of the system was demonstrated for the determination of metamizol in commercial samples with sixty results obtained per hour. The results obtained for metamizol in pharmaceutical formulations using the proposed flow procedure and those obtained using an iodimetric procedure are in agreement at the 95% confidence level and within an acceptable range of error.
Resumo:
An automatic flow injection procedure for spectrophotometric aluminium determination in purified water and solutions containing high salts concentrations used for hemodyalisis treatment was developed. The method was base on reaction of Al3+ with cianine eriochrome R (ECR) after preconcentration using the AG50W-X8 cationic-exchange resin. Elution was carried out using a 1 % (m/v) calcium chloride solution. The manifold comprised an automatic proporcional injector controlled by a computer equipped with an eletronic interface and software written in QuicBASIC 4.5 with facilities to control the injector and perform data acquisition. Samples with concentration ranging from 4.96 to 19.90 µg L-1 Al were analyzed and recoveries between 88 and 113% were obtained by using the standard addition method. Other profitable analytical characteristics such as a relative standard deviation 1.3 % (n = 10) for a typical sample 14.5 µg L-1 Al, a linear response ranging up to 60.0 µg L-1Al, and a sampling throughput of 10 determinations per hour were achieved. A detection limit of 4.2 µg L-1 Al was estimated as suggested by IUPAC.
Resumo:
European Directive (98/83/CE), compulsory after 2008, states that bromate in drinking water must be controlled at levels below 10 mg L-1. Supporting implementation of the Directive, the European Comission has established project SMT4-CT96 2134, in collaboration with various european institutions, aiming at the identification of the interferents to the current analytical method (Ionic Chromatography with Conductimetric Detection - IC/CD), their removal and the automation of pre-treatment and injection steps, as well as the development of alternative methods. EPAL, responsible for the water supply to a great deal of Portuguese regions, has taken steps to meet these requirements. Although not part of such project, this work (the result of a project conducted under a protocol of collaboration between EPAL SA and FCUL - Faculty of Sciences, University of Lisbon), reports on studies of usefulness to laboratories planning to monitor bromate in ozone treated waters, in conditions different from those described in EPA 300.1. Simultaneous determination of bromide is justified by its role as bromate precursor.
Resumo:
A new configuration for coupling a gas diffusion cell to a sequential injection system is presented. The matrix exchange is made without the need for additional rotary injection valves or peristaltic pumps, keeping the original mechanical components of the sequential injection apparatus: one syringe pump (or peristaltic pump) and one selection valve. The system was tested constructing analytical curves for sulfide exploring the formation of the methylene blue dye. The proposed method has a detection limit of 60 µg L-1 S2-, with a linear dynamic range between 0.10 and 4.0 mg L-1 S2- concentrations, with a sampling frequency of 20 h-1.
Resumo:
Immunoassay techniques provide simple, powerful and inexpensive methods for analysis of environmental contaminants. However, the acceptance of immunoassays is dependent on the clear demonstration of quality and validity compared to more traditional techniques. In this review, primarily, the understanding and the fundamentals of immunoassay methods are given in order to make good use of immunoassays, especially of EIA tests. Special attention is given to the concepts related to the enzyme-linked immunosorbent assay (ELISA) formats, such as inhibition concentration at 50% (IC50), detection limit (LOD), cross-reactivity (CR %). It is also explained why some immunoassays are quantitative methods whereas others can only be used as screening methods. A list of main commercial kits for detection of priority pollutants is given in order to help analysts. Others formats, such as flow-injection immunoassay analysis (FIIA), immunoassay chromatography and immunosensors are also cited.
Resumo:
A simple flow injection procedure was developed for determining dipyrone (1-phenyl-2,3-dimethyl-4-methylaminomethano-5-pyrazolone sodium, metamizol, analgin) in pharmaceutical formulations. The determination is based on the reduction of Ag+ ions to Ag0 by dipyrone. A colloidal suspension of Ag0 produced was transported by carrier solution (0.01 mol L-1 NaOH) and turbidimetrically detected at 425 nm. The analytical curve for dipyrone was linear in the range from 5.0 x 10-4 to 2.5 x 10-3 mol L-1 with a correlation coefficient of 0.9990. The detection limit was 1.3 x 10-4 mol L-1 (3sigmaB/slope). The relative standard deviation for ten successive measurements was 1.8% and an analytical frequency of 45 h-1 was obtained. The recovery values from three samples ranged from 96.0 to 102%.
Resumo:
An indirect flow injection spectrophotometric procedure is proposed for the determination of N-acetyl-L-cysteine in pharmaceutical formulations. In this system, ferroin ([Fe(II)-(fen)2]2+) in excess, with a strong absorption at 500 nm, is oxidized by cerium(IV) yielding cerium(III) and [Fe(III)-(fen)2]3+ (colorless), thus producing a baseline. When N-acetyl-L-cysteine solution is introduced into the flow injection system, it reacts with cerium(IV) increasing the analytical signal in proportion to the drug concentration. Under optimal experimental conditions, the linearity of the analytical curve for N-acetyl-L-cysteine ranged from 6.5x10-6 to 1.3x10-4 mol L-1. The detection limit was 5.0x10-6 mol L-1and recoveries between 98.0 and 106% were obtained. The sampling frequency was 60 determinations per hour and the RSD was smaller than 1.4% for 2.2x10-5 mol L-1 N-acetyl-L-cysteine.
Resumo:
A flow injection turbidimetric procedure exploiting merging zones is proposed for determining homatropine methylbromide (HMB) in pharmaceutical preparations. The determination is based on the precipitation reaction of homatropine methylbromide with AgNO3 solution to form a precipitate, which was measured at 410 nm. The analytical curve was linear in the HMB concentration range from 8.0x10-4 to 1.7x10-3 mol L-1, with a detection limit of 9.5x10-5 mol L-1. The recoveries ranged from 94.9 to 104 %, the sampling frequency was 75 h-1 and relative standard deviations were smaller than 2.0 % for solutions containing 1.2x10-3 and 1.5x10-3 mol L-1 HMB (n=10). The results obtained for commercial formulations using the FIA procedure were in good agreement with those obtained by using a comparative method (r= 0.9983).
Resumo:
The electrochemical applications of a CPE modified with chitosan for the determination of Cu(II) in wastewater samples using anodic stripping voltammetry are described. The best voltammetric response was observed for a paste containing 25% m/m of chitosan. A 0.10 mol L-1 NaNO3 solution (pH 6.5) as supporting electrolyte, a pre-concentration potential of -0.20 V, pre-concentration time of 270 s and a scan rate of 25 mV s-1 were selected. The calibration graph was linear in the Cu(II) concentration range from 2.0 x 10-7 to 7.4 x 10-6 mol L-1, with a detection limit of 8.3 x 10-8 mol L-1.
Resumo:
The present work purposes the development of an analytical method for amitriptyline determination in pharmaceutical formulations using FIA system. It was based on interaction of amitriplyline with sodium lauryl sulphate in acid medium (pH 2.5) resulting in the ion-pair formation turbidimetrically detected at 410 nm. The fitting regression equation for range curve from 2.0 x 10-3 up to 3.2 x 10-3 mol L-1 was found to be analytical signal = -2.7417 + 0.1538 [amitriptyline] (r = 0.99991) with a detection limit of 1.8 x 10-3 mol L-1. The precision assessed as relative standard deviation (n = 10) was found to be 2.40 and 1.94%, for the respective concentration of amitriplyline 2.0 x 10-3 and 3.2 x 10-3 mol L-1 and the sample throughout was 60 h-1. The accuracy of method was successfully assessed in pharmaceutical formulation after comparison with a reference analytical method.
Resumo:
A multicommuted method for determination of chlorine in water samples using a 100-cm cell was developed. In this method, orto-Tolidine reacts with chlorine and the product was monitored at 438 nm. The analytical curve for chlorine was linear in concentration range from 1.34x10-6 to 2.01x10-5 mol L-1 with a detection limit of 9.40x10-8 mol L-1. A sampling rate of 45 h-1and a RSD of 1.0 % (n = 15) were obtained. The method was applied with success for chlorine determination in six water samples.