Determinação de baixas concentrações de cobre em águas naturais por espectrofotometria de absorção atômica em chama usando um sistema SIA com uma coluna de poli(etilenimina)
| Data(s) |
01/10/2001
|
|---|---|
| Resumo |
This paper describes a sequential injection analysis (SIA) set-up coupled to a flame atomic absorption spectrometer (FAAS) to accomplish the determination of low concentrations of copper in drinking waters. Copper is first retained under neutral media in an on-line 29x1.6 mm column filled with poly(ethylenimine) immobilised on silica gel. The retained analyte is then eluted by flowing through the column 250 <FONT FACE=Symbol>m</font>L of a nitric acid solution. The selection of 3.85 ml of sample enabled to obtain a detection limit of 0.27 mug/L and a sampling rate of about 24 samples/h. There was a good agrement between the results of 12 samples furnished by the proposed procedure and by electrothermal atomic absorption spectrometry. Repeatability assessment gave a relative standard deviation of 1.3 % after ten replicate analysis of a sample containing about 70 mug/L in copper.. |
| Formato |
text/html |
| Identificador |
http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0100-40422001000500003 |
| Idioma(s) |
pt |
| Publicador |
Sociedade Brasileira de Química |
| Fonte |
Química Nova v.24 n.5 2001 |
| Palavras-Chave | #SIA/FAAS #copper #poly(ethylenimine) |
| Tipo |
journal article |